Public Works Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Public Works Department - PWD Tender
Civil And Construction
Eprocure
Opening Date27 Sep 2024
Closing Date17 Oct 2024
Tender Amount₹ 68,27,284 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 45,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Dlf Distribution Center Uhagamandalam
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_488357_1Bid Award Id
ViewTender No
07BCMCBE24092024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and filling in foundation and basement with Crushed Stone Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
38
-
-
Providing ANTI-TERMITE treatment to soil adjacent under building foundation, plinth periphery of the building by application of chemicals of ISI 6313-1981 part I to IV in stages to suit the progress of work as per the detailed specification (Measurements taken for the plinthe area for the purpose of payment) including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and incliding cost of chemicals, labour charges, transport and storing etc., complete complying with the standard specification and as directed by the departmental officers.
145
-
-
Stage.I. spraying anti- termite treatement chemicals solution for foundation concrete surface laying the foundation concrete bottom and sides of the foundation.
Stage.II. Spraying anti-termite chemical solution to the grade beam level, spraying for the grade beams, brick, masonry in superstructure in contact with the back fill earth.
Stage.III. Spraying anti-termite treatment, chemicals solution on sand for the flooring before laying the flooring zone, Treatment has tobe carried out by making crow bar holes at an interval of 12" to a depth of 8" on the sand filling in basement and after levelling operation is over.
Stage.IV. Spraying anti-termite treatment chemicals solution around the building (out side) by making crow bar holes at an interval of 12" to a depth of 8" in the periphery of building and chemical poured inside the holes and closed after the treatement.
-
-
-
CEMENT CONCRETE 1:5:10 [One Cement, Five CS Sand and Ten hard broken stone jelly] using 40 mm gauge hard broken granite stone jelly for FOUNDATION including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification.
20
-
-
CEMENT CONCRETE 1:5:10 [One cement, Five CS sand and Ten hard broken stone Jelly] using 40 mm gauge hard broken jelly for FLOORING including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. [The rate is inclusive of necessary planking for panelling wherever necessary and complete complying with standard specification and as directed by the departmental officers.
15
-
-
Supplying and erecting Steel Shuttering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as COLUMN FOOTINGS, COLUMN PEDESTALS, PLINTH BEAMS, GRADE BEAMS, STAIRCASE STEPS, etc., which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specification. [Payment for centering shall be given after the concrete is laid].
145
-
-
Supplying and erecting Centering for sides and soffits including necessary supports and strutting upto 3.29 M height For plane surfaces as detailed below , in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid).
-
-
-
FOR PLANE SURFACES SUCH AS RCC FLOOR SLAB, ROOF SLAB, RECTANGULAR BEAMS, ELL BEAMS, LINTELS, LANDING WAIST SLAB, CANOPY SLABS BED BLOCKS etc.,
249
-
-
FOR PLANE SURFACES SUCH AS RECTANGULAR OR SQUARE RCC COLUMNS TOP AND BOTTOM SLABS OF RCC BOXING SILL SLAB AND SUNSHADES ETC.
127
-
-
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/Cu.m and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu'm') 7670 kg. of cs sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
-
-
-
For Foundation & Basement
72
-
-
For Superstructure in Ground Floor
38
-
-
Supplying, fabricating and placing in position MILD STEEL / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. [Contractor has to make his own arrangements for the supply of steel and binding wire]
113
-
-
BRICK WORK in Cement Mortar 1:5 [One Cement and Five crushed stone Sand] using best quality Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].
-
-
-
For Foundation & Basement
21
-
-
BRICK WORK in Cement Mortar 1:6 [One Cement and Six crushed stone Sand] using best quality Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].
-
-
-
For Superstructure in Ground Floor
39
-
-
BRICK PARTITION walls of 11.00 cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7cm in Cement Mortar 1:3 [One Cement and CS Sand] using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers.
-
-
-
For Superstructure in Ground Floor
17
-
-
DAMP PROOF COURSE with Cement Mortar 1:4 [One Cement and CS Sand] 12mm thick with Bonding agent Cebexl 12, Zydex -Zycrete 2X or other equalent compound conforming to BIS at 200ml of one cement bag (50kg) for increased workability and air entrainment used finishing mixed with best approved quality water proofing compound conforming to Indian standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc., complete complying with standard specification.
40
-
-
PLAIN CEMENT CONCRETE 1:2:4 [one cement, two crushed stone Sand and four hard broken stone jelly] using 20 mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
11
-
-
Finishing the top of roof with one course of Machine Pressed Tiles of size 23cm x 23cm x (1.6-1.8)cm of approved quality set in Cement Mortar 1:3 (One Cement and Three CS Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
160
-
-
Paving the floor with best quality Double Charged Vertified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).
120
-
-
Paving the floor with Pre-Polished Concrete Anti-Skid Step Tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
10
-
-
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three CS sand) 10mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).
17
-
-
Flooring with Self Designed Colour CERAMIC TILES of 305 x 305 x 6mm size laid over 20 mm thick cement mortar 1:3 (One Cement and Three Crushed Stone Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
5
-
-
DADOOING walls with printed design colour glazed tiles of size 300 mm x 450 mm x 8 mm sizes set in Cement Mortar 1:2 [One Cement and Two Crushed Stone Sand] 10 mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg/m2 neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
14
-
-
Supplying and fixing of Hollow Pressed Steel Door Frames for single leaf and double leaved door using pressed steel frame of size 105x60mm using mild sheet of 1.25mm thick (18gauge) special profile extruded section.The pressed steel frame should be as per IS4351/1976.The rate is inclusive of bottom thehold fasts and provision to aldrop tower bolt hinges and lock plate etc,with one coat of zinc chromate yellow primer and filling the inside hollow portion with cement concrete 1:2:4 using 20mm HBG stone jelly etc,complete complying with standard specification and as directed by the departmental officers.
23
-
-
Supplying and fixing Solid Core Particle Board Flush Shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround Teak ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 1nos. 300x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops,2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers. [SINGLE LEAF]
6
-
-
Supplying and fixing Solid Core Particle Board Flush Shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround Teak ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 300x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops,3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers. [DOUBLE LEAVES]
4
-
-
Supply & fixing of WPC (Wood Polymer Composite) Frame extruded with size 75mm x 50mm. The single core door made of rigid WPC compound with minimum Bulk Density of 900 Kg/ Cu.m. & shore hardness of 55. Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 Kg/ Cu.m & shore hardness of 55. For the aesthetic appearance, the door shall be a printed digitally on one side of the shutter and the design is as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the WPC frame with 3 Nos of 5” SS Hinges and the door shall have 2 towerbolt on one side and 1 towerbolt or aldrop on other side for locking system and 2 numbers of handle on the either side of the door shutter, all made of aluminium.
3.2
-
-
Supply & fixing of PVC Wall Corner Beading etc., complete complying with standard specification and as directed by the departmental officers.
5
-
-
UPVC Window: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
19.5
-
-
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work.
1.1
-
-
Supplying and fixing MS Grills for windows, ventilators, etc., including priming coat etc., complying with standard specification and as directed by the departmental officers.
520
-
-
STUCCO PLASTERING 12mm thick using blue granite chips of size 10mm and below over the existing base plastering with cement mortar 1:5, 12mm thick mixed with Bonding agent cebexl 112,Zydex -Zycrete 2x or ther equivalent in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
92
-
-
PLASTERING with Cement Mortar 1:5 (One cement and Five p.sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equivalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
360
-
-
SPECIAL CEILING PLASTERING and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P.Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers.
301
-
-
Painting two coats of newly plastered wall surface with Ready Mixed Plastic Emulsion Paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
454
-
-
Painting two coats with approved Weather Proof Exterior Emulsion Paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specifications and as directed by the departmental officers.
303
-
-
Painting NEW IRON works such as steel doors, windows, ventilators, window bars, balustrades etc., with TWO COATS of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. [The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.]
31
-
-
PAINTING NEW WOOD WORKS with TWO coats of synthetic enamel paint of approved quality and colour over a priming coat with approved quality of white primer in all floors. The rate is inclusive of cost of all materials and labour, brushes and scaffolding charges etc., complete complying with standard specification. (The paint to be used should be got approved by the Executive engineer before use on work.
23
-
-
Supplying and fixing in position Steel balustrades using 20mm square rods spaced at 150mm centre to centre so that the two balustrades in each step shall be placed centrally and the top of balustrades connected with the hand rails (cost of hand rail shall be measured and paid separately) by means of MS flats of size 40mm x 6mm in the groove 40mm x 6mm provided at the bottom of hand rail; the bottom of balustrades shall be fixed on to the top of step concrete. An additional MS flat of size 50mm x 6mm shall be provided at the centre of balustrades connecting all square rods to the entire length including cost of square rods, flat and applying one coat of red oxide primer to the iron surfaces, etc., complete complying with standard specification and as directed by the departmental officers.
8
-
-
Supplying and fixing 40mm dia GI pipe for staircase hand rail including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers.
10
-
-
GST @ 18%
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements