Public Works Department Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date25 Nov 2024
Closing Date13 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work OPEN EXCAVATION in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.

10

-

-

... More
CEMENT CONCRETE 1:5:10 [One Cement, Five CS Sand and Ten hard broken stone jelly] using 40 mm gauge hard broken granite stone jelly for FOUNDATION including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification.

30

-

-

... More
Refilling Basement with Excavated Earth (other than CS sand) in layers of not more than 15cm thick watered, rammed well and consolidated etc., complete complying with standard specification and as directed by the departmental officers.

74

-

-

... More
Supplying and filling in foundation, basement with CONVEYED GRAVEL not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

183

-

-

... More
Supplying and filling in foundation and basement with Crushed Stone Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc., complete complying with standard specification and as directed by the departmental officers.

55

-

-

... More
BRICK WORK in Cement Mortar 1:6 [One Cement and Six CS Sand] using best quality Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].

-

-

-

... More
For Superstructure in Ground Floor

70

-

-

... More
For Superstructure in First Floor

70

-

-

... More
For Superstructure in Second Floor

32

-

-

... More
BRICK WORK in Cement Mortar 1:5 [One Cement and Five CS Sand] using best quality Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].

-

-

-

... More
For Foundation & Basement

47

-

-

... More
Damp proof course with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used, finishing and curing etc. complete complying with standard specification.

40

-

-

... More
Supplying and erecting Steel Shuttering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as COLUMN FOOTINGS, COLUMN PEDESTALS, PLINTH BEAMS, GRADE BEAMS, STAIRCASE STEPS, etc., which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specification. [Payment for centering shall be given after the concrete is laid].

216

-

-

... More
Supplying and erecting Centering for sides and soffits including necessary supports and strutting upto 3.29 M height For plane surfaces as detailed below , in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid).

-

-

-

... More
FOR PLANE SURFACES SUCH AS RCC FLOOR SLAB, ROOF SLAB, RECTANGULAR BEAMS, ELL BEAMS, LINTELS, LANDING WAIST SLAB, CANOPY SLABS BED BLOCKS ETC.,

855

-

-

... More
FOR PLANE SURFACES SUCH AS RECTANGULAR OR SQUARE RCC COLUMNS TOP AND BOTTOM SLABS OF RCC BOXING SILL SLAB AND SUNSHADES ETC.,

515

-

-

... More
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/Cu.m and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu'm') 7670 kg. of cs sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
For Foundation & Basement

98

-

-

... More
For Superstructure in Ground Floor

73

-

-

... More
For Superstructure in First Floor

72

-

-

... More
For Superstructure in Second Floor

3

-

-

... More
Supplying, fabricating and placing in position MILD STEEL / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. [Contractor has to make his own arrangements for the supply of steel and binding wire]

300

-

-

... More
Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three crushed stone sandand Six hard broken stone jelly). Dummy columns should be at least 1 metre height).

2

-

-

... More
CEMENT CONCRETE 1:5:10 [One cement, Five CS sand and Ten hard broken stone] using 40 mm gauge hard broken jelly for FLOORING including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. [The rate is inclusive of necessary planking for panelling wherever necessary and complete complying with standard specification and as directed by the departmental officers.

37

-

-

... More
BRICK PARTITION walls of 11.00 cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7cm in Cement Mortar 1:3 [One Cement and CS Sand] using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers.

-

-

-

... More
For Superstructure in Ground Floor

8

-

-

... More
For Superstructure in First Floor

8

-

-

... More
Paving the floor with best approved quality fine polished Kota stone slabs of 20mm thick with machine cut edges of size below 2'0"x2'0" laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.

580

-

-

... More
Dadooing walls with following best approved quality, with granite tiles of synthetic grey, paradise, and similar varieties of suitable sizes,set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.

36

-

-

... More
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).

38

-

-

... More
Supplying and fixing fine polished cuddapah slab of 38/40mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed.

18

-

-

... More
Providing single nosing to the fine polished kota stone slab of approved quality and best variety complete complying as per standard specification

96

-

-

... More
Providing Double nosing to the cuddapah slab of approved quality and best variety complete complying as per standard specification

40

-

-

... More
WEATHERING COURSE concrete in brick jelly lime concrete using broken brick jelly of size 20 mm uniform gauge in pure slaked lime [no sand to be used] to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.

-

-

-

... More
For Superstructure in Ground Floor

2

-

-

... More
For Superstructure in First Floor

23

-

-

... More
Finishing the top of roof with one course of Machine Pressed Tiles of size 23cm x 23cm x (1.6-1.8)cm of approved quality set in Cement Mortar 1:3 (One Cement and Three CS Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.

270

-

-

... More
Supplying and fixing in position best approved of BIS quality of 110mm dia PVC RAIN WATER DOWN FALL PIPES having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.

-

-

-

... More
ONE FLOOR

4

-

-

... More
TWO FLOOR

40

-

-

... More
Supplying and fixing in position Steel balustrades using 20mm square rods spaced at 150mm centre to centre so that the two balustrades in each step shall be placed centrally and the top of balustrades connected with the hand rails (cost of hand rail shall be measured and paid separately) by means of MS flats of size 40mm x 6mm in the groove 40mm x 6mm provided at the bottom of hand rail; the bottom of balustrades shall be fixed on to the top of step concrete. An additional MS flat of size 50mm x 6mm shall be provided at the centre of balustrades connecting all square rods to the entire length including cost of square rods, flat and applying one coat of red oxide primer to the iron surfaces, etc., complete complying with standard specification and as directed by the departmental officers.

28

-

-

... More
Supplying and fixing 40mm dia GI pipe for staircase hand rail including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers.

34

-

-

... More
Manufacturing supplying and fixing of STEEL DOOR with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x6mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter to conceal the gap between the two shutters at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specifications and as directed by the departmental officers.

-

-

-

... More
SINGLE LEAF

2.1

-

-

... More
. DOUBLE LEAVES

21

-

-

... More
Manufacturing, supplying and fixing of Entrance steel doors with the following specification M.S angles of a size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32x6mm M.S. flat is provided at required intervals in the shutter frames 18 gauge C.R. sheet is laid as panel in the shutter and welded intact for 1/3 bottom portion of the shutter. M.S. flat 18x5mm is welded over the 32x6mm M.S. flat sand witching the CR sheet in between. Additional stiffener with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 20 kg/sq.m with 300mm hieght of fixed glazing at top with 3mm thick Pin Headed glass including6 Nos hinges for double leaves shutter to be provided 6nos of holdfasts 120mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 2nos. one at top and the other at the bottom are provided one aldrop is provided at on appropriate place in the door. A Tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation or fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all meterials, labour charges, taxes, transportation to site of work, loading, unloading and all other incidental charges etc., complete. DOUBLE LEAVES (1/3 Panelled & 2/3 Grilled with top Ventilator)

8.5

-

-

... More
Fabricating, Supplying and fixng in position of Steel Sheeted Windows (Three Leaves) with the following specifications. Outer frames of windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion 'J' section (F4B) of size 46x25x3mm at 2.28kg/m and shutter section of made of F7D of 33x25x3mm at 1.419 kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS Flat at 0.70kg/m at 3 Nos. for each shutter and additional diagonal stiffners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly.2 numbers of sturdy hinges and one number of handle-cum-latch of special type made with 18x5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation. a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. each window shutter having an adustable stay made out of 18 x 5mm at 0.70 kg/ m MS flat of lenght 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18x5mm at 0.70kg/m, welded to the shutter at two place equivalent from each from top and bottom of the shutter.

43

-

-

... More
Fabricating, supplying and fixing of Steel Emergency exitdoor cum, emergency window with the following specification. M.S. angle in size 40x40x6mm are used for the outer frames and M.S. angle of sie 35x35x5mm for the shutter frame, stiffners with 32x6mm M.S. flats provided at required intervals in the shutter frames 18 guage CR sheet is laid as panel and welded instant for 1/3 bottom portion of the shutter, M.S. flat 18x5mm is welded over the 32x6mm M.S flat sandwitching the CR sheet in between additional stiffner with 18x5mm M.S. flat is provided diagonally at the rear-side of the shutter. (Double Leaves)

21

-

-

... More
Supplying and fixing M.S. Grill for openings corridor side ladder, Entrance Gate, Name Board angles and ornamental grill works etc., using M.S. flats for inner and outer members which should be fixed as directed by the departmental officers including cost of providing one coat of red oxide primer. The design of MS Grill should be got approved from the departmental officers before use on work.

2800

-

-

... More
STUCCO PLASTERING 12mm thick using blue granite chips of size 10mm and below over the existing base plastering with cement mortar 1:5, 12mm thick mixed with Bonding agent cebexl 112,Zydex -Zycrete 2x or ther equivalent in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.

97

-

-

... More
PLASTERING with Cement Mortar 1:5 (One cement and Five p.sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equivalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.

1529

-

-

... More
SPECIAL CEILING PLASTERING and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P.Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers.

738

-

-

... More
supplying and applying of Two coats of Putty of 3 MM thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing.The surface shall then be allowed to dry for at least 48 hours it shall then be sandpapered (Waterproof abrasive sheet)To give a smooth and even surface.Any unevenness shall be made good by applying First Court of Puti mixed with water on the entire surface including filling up the undulations and applying 2nd coat of booty after 6 hours of first coat of putty and then sandpapering(Waterproof abrasive sheet). The same after it is dry and finishing the surface smooth three etc complete compiling with standard specifications and as directed by the departmental officers.[The rates are inclusive of higher charges for grinding machine with wheel cost of sandpaper (Waterproof abrasive sheet)Cost of Putty Blade labor charges for grinding the joints and sandpapering two quotes of Puti scrapping the putty area to level the surface smooth etc complete.'].The putty should be got approved by the executive engineer before use on work .

363

-

-

... More
Painting two coats of newly plastered wall surface with Ready Mixed Plastic Emulsion Paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

1583

-

-

... More
Painting two coats with approved Weather Proof Exterior Emulsion Paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specifications and as directed by the departmental officers.

1154

-

-

... More
Painting NEW IRON works such as steel doors, windows, ventilators, window bars, balustrades etc., with TWO COATS of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. [The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.]

337

-

-

... More
Providing BLACK BOARD in two layers with first layer in Cement Mortar 1:5 (One Cement and Five crushed stone Sand) 20 mm thick and the second layer in combination mortar 1:1:6 (One Cement One Lime and Six cs Sand) 20 mm thick and providing band all round the Black board in C.M 1:5 (One Cement and Five cs Sand) for 20 mm thick and 50 mm width including cost of one coat of black oxide paint of approved quality complying with standard specifications and as directed by the departmental officers.

39

-

-

... More
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of 50mm thick in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers.

19

-

-

... More
Supplying and filling 40mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers

4

-

-

... More
Supplying and filling 20mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers

4

-

-

... More
Providing GRANOLITHIC FLOOR finish of 25mm thickness with Plain Cement Concrete 1:2:4 [One Cement, Two Crushed Stone Sand and Four Aggregate] using 10 to 12 mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc., complete complying with standard specification and as directed by the departmental officers. [The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers].

90

-

-

... More
Supplying and fixing Colour Galvalume Sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.

35

-

-

... More
Supplying and laying of Rubber Moulded Hydraulic Pressed Paver Block Stone 83mm thick over a base layer of sand filling including cost of materials laying and Labour charges etc., complete complying with standard specifications.

211

-

-

... More
DRILLING 150mm dia Vertical bore using power drill in hard rock to any required depth as directed by the departmental officers including labour charges for inserting casing pipes to the require depth assembly in drilled hole including welding the joint if necessary, grouting the casing pipe etc., and including transportation charges for the rig and support vehicle.

-

-

-

... More
upto 150m Below Ground Level

150

-

-

... More
151 to 180m

30

-

-

... More
Supplying and fixing of PVC CASING PIPE 160mm dia suitable for 6" Borewell conforming to I.S. 12818 - 1992 with screwed and socked and centering guides for every 15m interval etc., as directed by the departmental officers. [with / without slot]

24

-

-

... More
Supply suitable PVC End Cap (6kg/sqcm) of best for casing pipe of 6" dia borewell quality with ISI mark, The PVC should got approved by the departmental officers.

1

-

-

... More
Supplying and fixing and jointing 32mm dia UPVC pipe for submersible motor as per ISI mark etc., complete as per standard specification and as directed by the Departmental officers.

177

-

-

... More
Supplying and fixing erecting 5 HP ISI make bore well SUBMERSIBLE PUMPSET with requried accessories for the 5 HP ISI make 3 PHASE electric motor 2900 RPM, 400 / 440V 50Cys. Submersible Pumpset having brozen impellers, S.S.Shaft cable of discharging 100 to 200 LPM aginst a total Head of 135M to 100M with ISI Mark and with an outlet of 50mm and suitable for 150mm dia borewell including suppling and fixing M.S. fabricated wall mounting, excluding PANEL BOARD with internal wiring as per I.E. rules and necessary locking arrangements with

1

-

-

... More
Supplying and fixing M.S. fabricated wall mounting PANEL BOARD with internal wiring as per I.E. rules and necessary locking arrangements with suitable DOL type push button, STAR delta starter, suitable in amps DPC switch,0 to 500 V voltmeter, 0-20Amps Ammeter, single phase preventor, Pilot lamp with 3 bulbs to indicate power supply,3no. and including all specials. a) Suitable DOL push button automatic starter-1 no. b) Suitable15amps DPC switch - 1No. c) 0 to 500V Voltmeter - 1No. d) 0-20 Ammeter - 1No. e) Single phase preventor - 1No. f) Pilot lamp with three bulbs to indicate power supply - 1No. etc., complete.

1

-

-

... More
Supplying and fixing of 20mm dia Nylon rope for submersible motor of approved quality in etc,complete complying with standard specifications.

180

-

-

... More
Supply and run off WATER PROOF 3 CORE 4 sq.mm flat PVC insulated copper cable for submersible pumpset in the borewell including fixing and tying with copper wire and clamping water pipe etc., complete as directed by the departmental officers.

190

-

-

... More
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. Below Ground Level

-

-

-

... More
32mm dia

30

-

-

... More
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. Above Ground Level

-

-

-

... More
25mm dia

15

-

-

... More
Supplying and fixing in position UPVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the UPVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The UPVC specials should be got approved by the Executive Engineer before use on works).

-

-

-

... More
32mm dia UNION

5

-

-

... More
25mm dia UNION

3

-

-

... More
32mm dia ELBOW

5

-

-

... More
25mm dia ELBOW

4

-

-

... More
32mm dia TEE

5

-

-

... More
25mm dia TEE

4

-

-

... More
32mmx25mm dia REDUCER

5

-

-

... More
25mmx20mm dia REDUCER.

4

-

-

... More
20mmx15mm dia REDUCER

4

-

-

... More
25mm dia HEX NIPPLES

2

-

-

... More
Supplying and Fixing of Aluminium Dye Cast letters of following size to suit the Architectural elevation drawings given for the including Cost ,conveyance and all other materials and Labours involved etc., complete and as directed by the Department Officers.

-

-

-

... More
Aluminium Dye Cast Letters 9" size

23

-

-

... More
Aluminium Dye Cast Letters 6" size

31

-

-

... More
Manufacturing supplying and fixing in Position of the Tamil Nadu Government Emblem of dia 15" made upto 12mm thickness sheet including, Computer designing, drawing, pattern making, moulding, grinding, painting, the emblem etc., complete as directed by the department officers.

1

-

-

... More
Providing ANTI-TERMITE treatment to soil adjacent under building foundation, plinth periphery of the building by application of chemicals of ISI 6313-1981 part I to IV in stages to suit the progress of work as per the detailed specification (Measurements taken for the plinthe area for the purpose of payment) including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and incliding cost of chemicals, labour charges, transport and storing etc., complete complying with the standard specification and as directed by the departmental officers.

284

-

-

... More
Stage.I. spraying anti- termite treatement chemicals solution for foundation concrete surface laying the foundation concrete bottom and sides of the foundation. Stage.II. Spraying anti-termite chemical solution to the grade beam level, spraying for the grade beams, brick, masonry in superstructure in contact with the back fill earth. Stage.III. Spraying anti-termite treatment, chemicals solution on sand for the flooring before laying the flooring zone, Treatment has tobe carried out by making crow bar holes at an interval of 12" to a depth of 8" on the sand filling in basement and after levelling operation is over. Stage.IV. Spraying anti-termite treatment chemicals solution around the building (out side) by making crow bar holes at an interval of 12" to a depth of 8" in the periphery of building and chemical poured inside the holes and closed after the treatement.

-

-

-

... More
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS 15683 with pressure gauge, discharge hose & control nozzie, wall mounting bracket, safety clip etc., ncluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT/ SAFETY FIRST / EQUIVALENT.

2

-

-

... More
GST @ 18%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.