Public Works Department Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date12 Nov 2024
Closing Date26 Nov 2024
Tender Amount₹ 1,17,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling with excavated earth other than Sand with an initial head load and lift Charges and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification

56

-

-

... More
Supplying and filling in foundation, basement, with Conveyed earth with a lead of 0-5Km in Layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

83

-

-

... More
Pre-Construction anti-termite treatment plinth area – surface treatment stage-1 :- Completion of earth work for column footings before laying plain cement concrete 25mm dia Hole spaced at 30cm center to center on both direction will be made at the bottom of earth workand the chemical will be poured in the holes and will be sprayed in the four sides of earth work at the rate of 3 litres of chemical solution (Chlorophyrifos emulsion diluted in ration 1:19 (One emulsion and 19 water ) per square metre payment shall be made after completion of 3 stages.

235

-

-

... More
stage-II :- After filling the basement before laying flooring concrete with filling Crushed Stone(M-Sand) 25mm dia holes to adepth of 450mm will be made inside the basement and the chemical will be poured in the holes at the rate of 3 litres of chemical solution (Chlorophyrifos emulsion diluted in ration 1:19 (One emulsion and 19 water ) per square metre payment shall be made after completion of 3 stages. Peripheral treatment stage-III.On completion of building and leveling the outer area adjacent to the walls column ground ponds of size (900X300 mm will be filled in the ponds at the rate of 3 litre of chemical solution per Rm payment shall be made after completion of 3 stages. Stage-IV.Spraying termite solution around the building (Out side of the building) by making crowbar holes around the building before laying the plinth protection. This holes has to be closed after the treatment

-

-

-

... More
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)

160

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)

-

-

-

... More
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.

700

-

-

... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.

380

-

-

... More
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with

-

-

-

... More
about (4.79 cu'm') 7670 kg. of M-Sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
Foundation & Basement

69

-

-

... More
In Ground Floor

58

-

-

... More
In First Floor

55

-

-

... More
In Second Floor

5

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)

222

-

-

... More
Brick work in Cement Mortar1:6 ( one Cement and six Crushed Stone(M-Sand))using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specification.

-

-

-

... More
In Foundation & Basement

34

-

-

... More
In Ground Floor

53

-

-

... More
In First Floor

68

-

-

... More
In Second Floor

13

-

-

... More
Brick work in Cement Mortar1:5 ( one Cement and five Crushed Stone(M-Sand))using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specification.

-

-

-

... More
In Foundation & Basement

22

-

-

... More
Brick partition walls of 10.80cm thick using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three Crushed Stone(M-Sand)) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)

-

-

-

... More
In Ground Floor

7

-

-

... More
In First Floor

7

-

-

... More
Cement Concrete 1:5:10 (One Cement, Five Crushed Stone(M-Sand) and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for Flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification

22

-

-

... More
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three Crushed Stone(M-Sand)) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc Complete as Per Standard Specification., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification.

498

-

-

... More
Paving the floor with cement based Hydraulically pressed Anti skid tiles(pattern design)of 20mm thick of approved quality and colour laid in cement Mortar 1:3 (one cement and three crushed stone Crushed Stone(M-Sand)(M-Crushed Stone(M-Sand)) ) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 kg/sq.m. curing,etc. completed complying with standard specification and as direction by the departmental officers.

20

-

-

... More
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

17

-

-

... More
Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct by the departmental officers.

-

-

-

... More
38/40mm thick

14

-

-

... More
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no Crushed Stone (M-Sand) Sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.

18

-

-

... More
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed Stone (M-Sand) Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers

225

-

-

... More
Supplying and fixing in position best approved BIS quality of PVC rain water down fall pipes having a working pressure of 4 Kg./sq.cm of following dia. including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc. and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc. complete. The rate shall be inclusive of cost of removablecast iron grating. The PVC pipe shall be fixed in wall with special type of clamps. Special type of "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0 metre pipe length etc., complete complying with standard specification.

-

-

-

... More
110mm dia

44

-

-

... More
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick mixed with bonding agent cebex 112, zydex-zycrete 2X or other equivalent compound confirming to BIS at 200ml of 1 cement bag 50kg for increased workability and air entraintment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers

860

-

-

... More
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick mixed with bonding agent cebex 112, zydex-zycrete 2X or other equivalent compound confirming to BIS at 200ml of 1 cement bag 50kg for increased workability and air entraintment used finishing in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.

1630

-

-

... More
Supplying and fixing in position steel balustrade using 20mm size square bars at 15cm centre to centre and two balusters in single step centrally located and top shall be welded to 40mmx6mm mild steel flat to fix the handrail and bottom fixed in the step concrete M.S. Flats of size 50mmx6mm to be provided at the centre of the balustrade connecting all the square bars to the entire length of the balustrade and the square bars well anchord in the floor / step concrete through fish tail splay at bottom including painting the steel member of the balustrade with one coat of red oxide primer etc., complete complying with standard specifications.

15

-

-

... More
Supplying and fabricating and fixing of 40mm G.I. Pipe of‘B’ class for Hand Rails including cutting the pipe to the required length and shape grinding the edge smooth welding wherever necessary as directed by the departmental officers including cost of one coat of red oxide primer as directed by the departmental officers etc. complete complying with standard specifications. The rate includes cost of G.I.Pipe, taxes and labour charges for fixing in position.

18

-

-

... More
Providing and fixing Hand Rail made out of SS 304 grade 50mm dia Stainless steel tube of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel tube of 1.00mm thick as vertical at 900mm centre to centre with 2 Nos. of 25mm dia horizontal stainless steel tubes of 1.60mm thick in between as per the details shown in the drawing and as directed the rate shall include for grouting with concrete into necessary supporting arrangements of handrail verticals and in floor welding the base cup of the post into slab reinforcement, polishing butting and protecting the hand rail surface etc., complete as directed by the departmental officers.

15

-

-

... More
Manufacturing, supplying and fixing of steel doors with following specification. MS Angle of size 40x40x6mm at 3.5 Kg/m used for outer frame and MS Angle f size 35 x 35 x 5mm at 2.6 Kg/m for the shutter frame. Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided at required intervals in the Shutter frame and welded intact on both ends to the shutter frame. 18GCR Sheets of best quality is laid as panel in the shutter frames.18x5mm at 0.70 Kg/m MS Flat is welded over the 32x6mm @ 1.50 Kg/m MS Flat on the rear side of the door, sand witching the CR sheet for rigidity. Additional stiffeners with 18x5mm at 0.7 Kg/m MS Flats are provided diagonally on the rear side of the shutter. 3 Nos. of hinges in case of single leaf and 6 Nos. of hinges in case of double leaf shutters is provided. 6 Nos. of hold fasts 200mm length spliced at the ends are welded to the outer frame of the door. Tower bolt 2 Nos., one at the top and the other at bottom are provided. One aldrop is provided in case of double leaf door at lock rail section in the door. In single leaf doors, one more aldrop is provided in the inner side of the lock rail section

-

-

-

... More
of the door, one rotating locking arrangementslocking arrangements for inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place in case of a double leaf door. MS Flat 32x3mm at 1.10 Kg/m is provided on the edge of the one shutter to conceal the gap between the two shutters. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete.

-

-

-

... More
Single Leaf(1.00 x 2.10m)

2.1

-

-

... More
DoubleLeaves (1.20 x 2.10 m)

16

-

-

... More
Fabricating, supplying and fixing of steel Emergency exit door cum, emergency window with the following specification. M.S. angle in size 40x40x6mm are used for the outer frames and M.S. angle of sie 35x35x5mm for the shutter frame, stiffners with 32x6mm M.S. flats provided at required intervals in the shutter frames 18 guage CR sheet is laid as panel and welded intect for 1/3 bottom portion of the shutter, M.S. flat 18x5mm is welded over the 32x6mm M.S flat sandwitching the CR sheet in between additional stiffner with 18x5mm M.S. flat is provided diagonally at the rear-side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 15kg/m2 and the top portion of operation emergency window is to be made of 25x25x3mm M.S. angle welded intact with CR sheet and 25x3mm M.S. flat at diagonally at the rear side of the window at required intervals 6 Nos. of hinges to be provided,6 Nos of holdfast 100mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 2 Nos. one at top and the

16

-

-

... More
other at the bottom are to be provided one aldrop is provided at an appropriate place in the door 2 Nos. of 'D' type handle for emergency window and 2 Nos of handle for door is to be provided at appropriate places. A tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation of fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of materials, labour transportation to side of works, loading, unloading and all other incidental charges etc., complete.A) Doube Leaf door(1.20 x2.10m)

-

-

-

... More
Manufacturing, supplying and fixing in position of Steel Sheeted windows with the following specifications. Outer frames of windows made of ‘Z’ section F7D of size 33 x 25 x 3mm at 1.419 Kg/m and mullion ‘J’ Section (F4B) of size 46 x 25 x 3mm at 2.28 Kg/m and shutter section of made of F7D of 33 x 25 x 3 mm at 1.419 Kg/m as specified in IS 7452 / 1990.Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18 x 5mm MS Flat at 0.70 Kg/m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS Flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in positional firmly.

-

-

-

... More
2 numbers of sturdy hinges and one number of handle-cum-latch of special type made with 18 x 5mm MS Flats are revetted to the shutters at an appropriate height in window. Suitable opening is left for its easy operation. A stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. Each window shutter having an adjustable stay made out of 18 x 5mm at 0.70 Kg/m MS Flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the outer frame of the window by using MS Flat of 18 x 5 mm at 0.70 Kg/m, welded to the shutter at two place equivalent from each other from top and bottom of the shutter.An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge to edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS 7452 / 1990. The cost includes cost of all materials, labour charges and other incidental charges, etc., complete.

-

-

-

... More
Three Leaves Shutters

33

-

-

... More
Providing cupboard Shutters using termited water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutters and 1mm thick fixed in the outside of the shutters using fevicolalong with necessary furniture fittings, such as hydraulic hinges, tower bolts, handles, multi purpose locks etc., as directed by the departmental officers.The design pattern, water proof plywood, laminate sheet and other materials should be got approved from Executive Engineer before use on works.

16

-

-

... More
Supplying and fixing mild steel iron grill for windows ventilators and grill gate etc., including one coat of red oxide primer using M.S angle of size 40 x 40 x 6 mm and grill using 20 x 6mm M.S flat and necessary hold fast with M.S angle of size 40 x 40 x 6 mm - 230 mm long spliced at end is to be provided at appropriate places for fixing the grill etc., complete complying with standard specification. The type design for the grills should be got approved by the departmental officers before execution.

2100

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed Plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

1245

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

902

-

-

... More
Painting new iron work with two coats of best first quality synthetic enamel paint of approved colour over the existing red-oxide primer coat in all floors excluding cost of priming coat etc. complete complying with standard specification. (The brand, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

291

-

-

... More
Providing Black Board in Two layers with first layer in cement mortar 1:5, 20mm thick and second layer in combination mortar 1:1:6, 20mm thick and providing boarder alround the block board in cement mortar 1:5 20mm thick and 50mm width including cost of one coat of block oxide paint of approved quality etc., complete complying with standard specification as directed by the departmental officer.

24

-

-

... More
Supplying and Installation of Ceramic Steel Chalk writing board with the following specification .GI sheet of 2mm thickness is fixed with the wall side.Over the GI sheet necessary special adhesive is spreaded and 9mm MDF Board is fixed on this GI sheet. 0.40mm thick ceramic chalk board is provided over the MDF board and the whole arrangements are fixed to the frame using heavy anodised aluminium sectoin and chromium plated provided in the corners . The whole arrangments are fixed to the wall using wooden plugs,screws,etc.,complete.,complying with standard specification.

20

-

-

... More
Manufacturing, supplying and fixing in positon of RCC Jally of 5cm thick in cement concrete 1:2:4 using 20mm machine crushed stone jelly (excluding cost of reinforcement steel) including cost of mould, finishing, curing, lifting, fixing in position etc., complete complying with standard specification and as directed by the departmental officers

6

-

-

... More
Supplying and fabricating and fixing of 50mm dia G.I. Pipe for purlins including labour charges for cutting, welding and fixing with sheet roofing etc.

23

-

-

... More
Supplying and fixing colour coated Galvalum sheet roofing with 0.47mm tk. sheet of approved quality by drilling holes(and not by punching) with necessary 'J'/'U' bolts and nuts of 8mm dia of suitable length and providing one set of bitumen washers of 25mm dia and 1.60mm thick for each bolt including protruding portion of bolts in roof shall be covered with bitumen compound etc. complete complying with standard specification and as directed.

35

-

-

... More
Manufacturing, supplying and fixing in position plain cement concrete precast pavement slab of size 450mm x 450mm of 50mm thick in Cement Concrete 1:2:4 (One cement, Two Crushed Stone(M-Sand) and Four jelly) using 20mm HBG stone jelly including cost of moulding charges, casting of slab, finishing, curing, fixing and pointing the slab with CM 1:3 (One Cement and Three Crushed Stone(M-Sand)) to full depth of slab etc., complete complying with standard specification and as directed

61

-

-

... More
GST 18 %

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.