Public Works Department Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date29 Nov 2024
Closing Date27 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work OPEN EXCAVATION in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.

188

-

-

... More
Supplying and filling in foundation and basement with Filling Crushed Stone Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc., complete complying with standard specification and as directed by the departmental officers.

1

-

-

... More
Supplying and filling in foundation and basement with Excavated Earth in layers of not more than 15 cm thick well watered, rammed and consolidated etc., complete complying with standard specification and as directed by the departmental officers.

282

-

-

... More
Supplying and filling in foundation, basement with Conveyed Earth not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

216

-

-

... More
Supplying and filling in foundation, basement with CONVEYED GRAVEL not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

102

-

-

... More
Supplying and filling in foundation, basement with stone dust not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

135

-

-

... More
CEMENT CONCRETE 1:5:10 [One Cement, Five Crushed Stone Sand and Ten hard broken stone jelly] using 40 mm gauge hard broken granite stone jelly for FOUNDATION including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification.

151.5

-

-

... More
CEMENT CONCRETE 1:5:10 [One cement, Five CS sand and Ten hard broken stone] using 40 mm gauge hard broken jelly for FLOORING including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. [The rate is inclusive of necessary planking for panelling wherever necessary and complete complying with standard specification and as directed by the departmental officers.

96.5

-

-

... More
Rough Stone Dry Packing

18

-

-

... More
R.R Masonary in cement mortar1:5 (one cement,and five crushed stone sand) for foundation and basement including simultaneously pointing above ground level with the same mortar etc.,complete

11

-

-

... More
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as COLUMN FOOTINGS, COLUMN PEDESTALS, PLINTH BEAMS, GRADE BEAMS, STAIRCASE STEPS, etc., which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. [Payment for centering shall be given after the concrete is laid].

979

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height For plane surfaces as detailed below , in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid).

-

-

-

... More
RCC FLOOR SLAB, ROOF SLAB, RECTANGULAR BEAMS, ELL BEAMS, LINTELS, LANDING WAIST SLAB, CONAPY SLABS BED BLOCKS etc.,

7144

-

-

... More
FOR RECTANGULAR OR SQUARE RCC COLUMNS TOP AND BOTTOM SLABS OF RCC BOXING TO WINDOWS RCC SUNSHADES etc.,

3879

-

-

... More
FOR PLANE SURFACES SUCH AS VERTICAL SLAB, SIDE SLABS OF BOXING, VERTICAL DROPS, FACIA, VERTICAL WALL, ETC.

120

-

-

... More
FOR CIRCULAR COLUMNS ETC.,

125

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
For Foundation & Basement

910

-

-

... More
For Superstructure in Ground Floor

216

-

-

... More
For Superstructure in First Floor

232

-

-

... More
For Superstructure in Second Floor

213

-

-

... More
For Superstructure in Third Floor

215

-

-

... More
For Superstructure in Fourth Floor

212

-

-

... More
For Superstructure in Fifth Floor

215

-

-

... More
For Superstructure in Sixth Floor

31

-

-

... More
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/ms and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retad setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu'm') 7670 kg. of cs sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
For Foundation & Basement

42

-

-

... More
For Superstructure in Ground Floor

52.5

-

-

... More
Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three crushed stone sandand Six hard broken stone jelly). Dummy columns should be at least 1 metre height). (Sixth Floor)

5.5

-

-

... More
Supplying, fabricating and placing in position MILD STEEL / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. [Contractor has to make his own arrangements for the supply of steel and binding wire]

3829

-

-

... More
DAMP PROOF COURSE with Cement Mortar 1:4 [One Cement and CS Sand] 12mm thick with Bonding agent Cebexl 12, Zydex -Zycrete 2X or other equalent compound conforming to BIS at 200ml of one cement bag (50kg) for increased workability and air entrainment used finishing mixed with best approved quality water proofing compound conforming to Indian standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc., complete complying with standard specification.

155

-

-

... More
Providing ANTI-TERMITE treatment to soil adjacent under building foundation, plinth periphery of the building by applcation of chemicals of ISI 6313-1981 part I to IV in stages to suit the progress of work as per the detailed specification (Measurements taken for the plinthe area for the purpose of payment) including breaking of termite mounds, making holes with clow bar, closing the holes after the treatment and incliding cost of chemicals, labour charges, transport and storing etc., complete complying with the standard specification and as directed by the departmental officers.

982

-

-

... More
Stage.I. spraying anti- termite treatement chemicals solution for foundation concrete surface laying the foundation concrete bottom and sides of the foundation. Stage.II. Spraying anti-termite chemical solution to the grade beam level, spraying for the grade beams, brick, masonry in superstructure in contact with the back fill earth. Stage.III. Spraying anti-termite treatment, chemicals solution on sand for the flooring before laying the flooring zone, Treatment has tobe carried out by making crow bar holes at an interval of 12" to a depth of 8" on the sand filling in basement and after levelling operation is over. Stage.IV. Spraying anti-termite treatment chemicals solution around the building (out side) by making crow bar holes at an interval of 12" to a depth of 8" in the periphery of building and chemical poured inside the holes and closed after the treatement.

-

-

-

... More
BRICK WORK in Cement Mortar 1:5 [One Cement and Five crushed stone Sand] using best quality chamber burnt Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].

-

-

-

... More
For Foundation & Basement

58.5

-

-

... More
BRICK WORK in Cement Mortar 1:6 [One Cement and Six crushed stone Sand] using best quality Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].

-

-

-

... More
For Foundation & Basement

135

-

-

... More
For Superstructure in Ground Floor

201.5

-

-

... More
For Superstructure in First Floor

149

-

-

... More
For Superstructure in Second Floor

154

-

-

... More
For Superstructure in Third Floor

150

-

-

... More
For Superstructure in Fourth Floor

155

-

-

... More
For Superstructure in Fifth Floor

145

-

-

... More
For Superstructure in Sixth Floor

51

-

-

... More
BRICK PARTITION walls of 11.00 cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7cm in Cement Mortar 1:3 [One Cement and CS Sand] using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers.

-

-

-

... More
For Superstructure in Ground Floor

102

-

-

... More
For Superstructure in First Floor

130

-

-

... More
For Superstructure in Second Floor

102

-

-

... More
For Superstructure in Third Floor

85

-

-

... More
For Superstructure in Fourth Floor

190

-

-

... More
For Superstructure in Fifth Floor

96

-

-

... More
Brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime 1:2:5 (one cement two sand and five brick jelly) by volume and laid over the toilet depression portions in a single layer of required slope etc., complete as per standard specification and as directed by the deparmental officers.

30

-

-

... More
Paving the floor with best quality Vertified Tiles of size 800 x 800 x 10mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

1979

-

-

... More
Flooring with Self Designed Colour ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

190

-

-

... More
Dadooing walls with printed design colour glazed tiles of size 300mm x 600mm x 10 mm best approved quality, white / colour glazed tiles set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.

4500

-

-

... More
DADOOING walls with Granite tiles of synthetic grey, paradise, and similar varieties of suitable sizes set in Cement Mortar 1:2 [One Cement and Two Crushed Stone Sand] 10 mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg/m2 neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.

125

-

-

... More
Supply and fixing of PVC Wall Corner beading etc., complete complying with standard specification and as directed by the departmental officers.

1110

-

-

... More
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 10mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).

660

-

-

... More
Supplying and fixing fine polished cuddapah slab of 20/30mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed.

115

-

-

... More
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.

830

-

-

... More
Supplying and fixing Granite slabs (Super fine polished with machine cut edges) of sizes 1200 x 600 of 18 / 20mm thick .

35

-

-

... More
Providing Single nosing for Granite slab etc., complete as per standard specification and as directed by the departmental officers.

645

-

-

... More
PLAIN CEMENT CONCRETE 1:2:4 [one cement, two crushed stone Sand and four hard broken stone jelly] using 20 mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.(For Foundation and Basement)

18.5

-

-

... More
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.

-

-

-

... More
For Superstructure in Ground Floor

21

-

-

... More
For Superstructure in Fourth Floor

52

-

-

... More
For Superstructure in Fifth Floor

7

-

-

... More
Finishing the top of roof with one course of Machine Pressed Tiles of size 23cm x 23cm x (1.6-1.8)cm of approved quality set in Cement Mortar 1:3 (One Cement and Three Cs Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.

991

-

-

... More
Supplying and fixing in position best approved of BIS quality for following sizes PVC RAIN WATER DOWN FALL PIPES having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.

-

-

-

... More
160 mm dia (Five Floor)

289

-

-

... More
110 mm dia (Six Floor)

29.7

-

-

... More
Supplying and fixing of Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm using mild sheet of 1.25mm thick (18gauge) special profile extruded section.The pressed steel frame should be as per IS4351/1976.The rate in inclusive of bottom thehold fasts and provision to aldrip tower bolt hinges and lock plate etc,with one coat of zinc chnomate yellow primer and filling the inside hallow portion with cement concrete 1:2:4 using 20mm HBG stone jelly etc,complete complying with standard specification.

220

-

-

... More
Supplying and fixing solid core particle board flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround commercial ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 150x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops,3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers. [SINGLE LEAF]

90

-

-

... More
Supplying, fabricating and fixing in position factory made Stainless Steel Flush Door Shutter 35mm thick using SS 304 Grade 1.6 mm thick, Stainless Sheets on both sides (Equivalent to IS 6911-04 Cr. 19, Ni 9) minimum 8-8.5% nickel and 18% chromium Sourced from original stainless steel manufacturer with view panel size 30mm x 45mm made up of 6mm thick clear toughened glass fitted with double side adhesive tape and finished with dowconing silicon sealant, floor spring for each shutter, consealed tower bolt, suitable stainless steel locking arrangement and other necessary furniture fittings of approved quality. The vertical styles and other frame members and cross stiffeners shall be of same quality stainless steel box section of suitable size and thickness with proper core material as prescribed by the Departmental Officers

13

-

-

... More
Providing and fixing of 1.2mm thick Lead Lining Door for X-Ray Rooms, Scanning Rooms with Mild Steel Door Frames 105mm x 57mm X 18 G and 12 G x 50mm Shutter made of GI with PWG finish and honey wool insulations with SS 101mm x 75mm x 3mm SS 304 Ball Bearings Butt Hinges, Mortice Sash Lock ML 100A, 50mm BS, 85mm centre, CL 207 : Key & Knob 70mm, 5 Pin Cylinder with Handle SS Finish (Dorma Make), Heavy Duty Door Closer, Frames fixed wih walls using Mortice Sash Lock ML 100A, 50mm BS, 85mm centre CL207: Key & Knob 70mm, 5 Pin Cylinder with Handle SS Finish (Dorma Make) all neccesary accessories and fittings as per the required and as per the approval for the Department Officer

6.3

-

-

... More
Supply & fixing of WPC (Wood Polymer Composite) Frame extruded with size 75mm x 50mm. The single core door made of rigid WPC compound with minimum Bulk Density of 900 KG/ Cub.Mt. & shore hardness of 55. Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/ Cub.Mt. & shore hardness of 55. For the aesthetic appearance, the door shall be a printed digitally on one side of the shutter and the design is as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the WPC frame with 3 Nos of 5” SS Hinges and the door shall have 2 towerbolt on one side and 1 towerbolt or aldrop on other side for locking system and 2 numbers of handle on the either side of the door shutter, all made of aluminium.

90

-

-

... More
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work.

37

-

-

... More
Manufacturing supplying and fixing of STEEL DOOR [SINGLE LEAF] with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x6mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts

10.5

-

-

... More
2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter to conceal the gap between the two shutters at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specifications and as directed by the departmental officers.

-

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for Staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100x100x6mm MS base plate encased in the base concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges etc., complete.

106

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing.The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete

43

-

-

... More
Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/ Cub.Mt. & shore hardness of 55. The door shall be a plain matt board as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the Aluminium “G” type channel with Wheel and the door shall have 2 Hooks in SS, 2 Handles 4” in SS.(Sliding door)

2.6

-

-

... More
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam.

63

-

-

... More
UPVC Window: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.

313.5

-

-

... More
Supplying and fixing M.S. Grill for openings corridor side ladder, Entrance Gate and Name Board angles etc., using M.S. flats for inner and outer members which should be fixed as directed by the departmental officers including cost of providing one coat of red oxide primer. The design of MS Grill should be got approved from the departmental officers before use on work.

9250

-

-

... More
Supplying and fixing of SS Wall Cladding etc., complete complying with standard specification and as directed by the departmental officers.

210

-

-

... More
Supplying and fixing of SS False Ceiling etc., complete complying with standard specification and as directed by the departmental officers.

113

-

-

... More
Supplying, fabricating, erecting and fixing Hilux (or) equivalent board false ceiling upto a ceiling height of 4.5m from floor level.using With good quality hilux board plain sheets 10mm thick including hanging arrangements with alumium section etc., complete complying with standard specification and as directed by the departmental officers.

185

-

-

... More
Supplying and fixing of Gypboard cornice etc., complete complying with standard specification and as directed by the departmental officers.

77

-

-

... More
SPECIAL CEILING PLASTERING and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P-Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers

8450

-

-

... More
PLASTERING with Cement Mortar 1:5 (One cement and Five p.sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.

6623

-

-

... More
PLASTERING the surface of walls with Cement Mortar 1:3 (One cement and Three P- sand), 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement and with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.

426

-

-

... More
FLOORING -SEAMLESS VINYL FLOORING WITH ANTI STATIC AND ANTI MICROBIAL PROPERTY :It shall be self levelling 3.00 mm anti static seamless vinyl flooring. Floor shall be smooth,non-slip,impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock.It shall be Electro Static Discharge (ESD) combat PVC seamless flooring of very high quality thickness is not less than 2.00mm. Continuous roll shall be used and with minimum joints. The Joints to be welded by special PY thermal units using PVC welding bars of same colors

190

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed Plastic Emulsion Paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

8555

-

-

... More
Painting two coats of newly plastered wall surface with Weatherproof Exterior Emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

5922

-

-

... More
Painting NEW IRON works such as steel doors, windows, ventilators, window bars, balustrades etc., with TWO COATS of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. [The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.]

424.5

-

-

... More
PAINTING NEW WOOD WORKS with TWO coats of synthetic enamel paint of approved quality and colour over a priming coat with approved quality of white primer in all floors. The rate is inclusive of cost of all materials and labour, brushes and scaffolding charges etc., complete complying with standard specification. (The paint to be used should be got approved by the Executive engineer before use on work.

218

-

-

... More
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete complying with standard specification and as directed by the departmental officers.

807

-

-

... More
Providing Additional Strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part there of but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.

4273

-

-

... More
Supplying and fixing in position White Glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 110mm dia / PVC pipe of 100mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings.such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works).

36

-

-

... More
Supplying and fixing in positon INDIAN WATER CLOSET (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two cs sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).

2

-

-

... More
Supplying and fixing position PVC NAHANI TRAP / Floor Trap of 100 x 75 mm sizes with best PVC gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three cs sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)

48

-

-

... More
Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)

2

-

-

... More
Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).

13

-

-

... More
Supplying and fixing approved best quality aluminium anodised TOWEL RAIL 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).

48

-

-

... More
Supplying and fixing in position INDIAN MAKE BEVELLED EDGE MIRROR of approved quality and brand PVC/ Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)

15

-

-

... More
Supplying and fixing best approved best quality brass CP SOAP TRAY of size 150 x 100mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).

15

-

-

... More
Supplying , fixing in position and testing SS health faucet with wall hook one metre long flexible tube, angle cock with wall flange all complete including cutting and making good the walls wherever required.

36

-

-

... More
Supplying and fixing in position 15 mm dia brass CHROMIUM PLATED SCREW DOWN TAP/ PILLAR TAP [heavy duty] of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. [Taps should be got approved by the Executive Engineer before use on the works]

7

-

-

... More
Supplying and fixing in position 15 mm dia brass LONG BODY TAP [heavy duty] of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. [Taps should be got approved by the Executive Engineer before use on the works]

48

-

-

... More
Supplying and fixing in position 15 mm dia brass Angle Cock [heavy duty] of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. [Taps should be got approved by the Executive Engineer before use on the works]

32

-

-

... More
Supplying and fixing in position 15 mm dia SS ELBOW ACTION TAP [heavy duty] of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. [Taps should be got approved by the Executive Engineer before use on the works]

18

-

-

... More
Supplying and fixing in position best quality PVC SOIL / WASTE PIPES of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry. RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. [The PVC pipes should be got approved by the Executive Engineer before use on works]. The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level.

-

-

-

... More
160mm dia

250

-

-

... More
110mm dia

95

-

-

... More
75 mm dia

170

-

-

... More
Supplying and fixing in position PVC SPECIALS of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. [The PVC specials should be got approved by the Executive Engineer before use on works].

-

-

-

... More
160mm dia ELBOW with DOOR

7

-

-

... More
160mm dia TEE

15

-

-

... More
160mm dia DOUBLE Y WITH DOOR

6

-

-

... More
160mm dia PVC SINGLE Y WITH DOOR

14

-

-

... More
110mm dia PVC ELBOW WITH DOOR

20

-

-

... More
110mm dia TEE

10

-

-

... More
75mm dia ELBOW with DOOR

20

-

-

... More
75mm dia TEE

25

-

-

... More
110mm dia DOUBLE Y

10

-

-

... More
110mm dia SINGLE Y

14

-

-

... More
Supplying, laying and jointing CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. Internal Water Supply-Above Ground Level

-

-

-

... More
20mm dia

132

-

-

... More
25mm dia

18

-

-

... More
Supplying, laying and jointing CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. External Water Supply-Below Ground Level

-

-

-

... More
50mm dia

10

-

-

... More
40mm dia

383

-

-

... More
32mm dia

325

-

-

... More
Supplying, laying and jointing CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. External Water Supply-Above Ground Level

-

-

-

... More
50mm dia

150

-

-

... More
32mm dia

90

-

-

... More
25mm dia

206

-

-

... More
Supplying and fixing in position CPVC SPECIALS of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the CPVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. [The CPVC specials should be got approved by the Executive Engineer before use on works].

-

-

-

... More
20mm dia ELBOW

30

-

-

... More
20mm dia TEE

30

-

-

... More
25mm dia ELBOW

26

-

-

... More
25mm dai TEE

20

-

-

... More
25mm dia Coupler

25

-

-

... More
25mm dia BEND

6

-

-

... More
32mm dia COUPLER

23

-

-

... More
32mm dia ELBOW

18

-

-

... More
32mm dia TEE

17

-

-

... More
40mm dia ELBOW

16

-

-

... More
40mm dia TEE

15

-

-

... More
50mm dia ELBOW

15

-

-

... More
50mm dia TEE

15

-

-

... More
40mm dia UNION

10

-

-

... More
Supplying and fixing in position first quality and approved variety of Gun metal GATE VALVE with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications [for both internal and external water supply arrangements]. The valves to be used on work shall be got approved by the Executive Engineer before use on work.

-

-

-

... More
40mm dia

8

-

-

... More
32mm dia

4

-

-

... More
25mm dia

40

-

-

... More
DRILLING 150mm dia [6"] Vertical bore using power drill in hard rock to any required depth as directed by the departmental officers including labour charges for inserting casing pipes to the require depth assembly in drilled hole including welding the joint if necessary, grouting the casing pipe etc., and including transportation charges for the rig and support vehicle.

-

-

-

... More
Borewell upto 150m below GL

150

-

-

... More
From 151m upto 180m

30

-

-

... More
From 181m upto 210m

30

-

-

... More
From 211m upto 241m

30

-

-

... More
From 241m upto 250m

10

-

-

... More
Supplying and delivery of PVC CASING PIPE (6kg/sqcm) 150mm dia suitable for 6" Borewell conforming to IS 12818/1992 with ISI Marking of following diameter in 3m length with screwed and socket end and centering guides for every 15m length of pipe to suit deep bore wells for delivery including loading, unloading, freight, insurance etc., complete (Rate inclusive of Excise duty)

20

-

-

... More
Supplying and fixing 5HP stage delivery submersible motor including panel board ISI make for 6" dia bore well with pump, necessary accessories such as bolt gun metal jet assembly with 1 number pressure gauge metal complete comprising with the following additional accessories and submersible cable. - The motor shall be of ISI approved variety and shall be got approved by Executive Engineer before erection- Accessories:-. a. 3 Phase star delta starter of 32 AMP of approved quality and make with ISI marks - 1 No. b. 3 Phase 32 AMP main switch of approved quality and make with ISI marks - 1 No. c. Single phase preventer of approved quality and make with ISI marks - 1 No. d. Switch Board to accommodate the starter and main switch power capacitor of suitable capacity as per standard norms of TNEB.

3

-

-

... More
Supplying and fixing M.S. fabricated wall mounting PANEL BOARD with internal wiring as per I.E. rules and necessary locking arrangements with suitable DOL type push button, STAR delta starter, suitable in amps DPC switch,0 to 500 V voltmeter, 0-20Amps Ammeter, single phase preventor, Pilot lamp with 3 bulbs to indicate power supply,3no. and including all specials. a) Suitable DOL push button automatic starter-1 no. b) Suitable15amps DPC switch - 1No. c) 0 to 500V Voltmeter - 1No. d) 0-20 Ammeter - 1No. e) Single phase preventor - 1No. f) Pilot lamp with three bulbs to indicate power supply - 1No. etc., complete.

2

-

-

... More
Supply and run off WATER PROOF 3 CORE 4.0 sq.mm flat PVC insulated copper cable for submersible pumpset in the borewell including fixing and tying with copper wire and clamping water pipe etc., complete as directed by the departmental officers.

220

-

-

... More
Supplying and fixing of 25mm dia Nylon Rope for submersible motor of approved quality in etc,complete complying with standard specifications.

270

-

-

... More
Supply, erection, testing and commissioning of Gun Metal Non - Return Valve of size 50mm dia including necessary MS flange of table 'E' gaskets, bolts & nuts etc., installed at pump house delivery line for the purpose of priming to suction line so that to control one way including conveyance, fixing and incidental charges etc., complete as per standard specification and as directed by the Departmental Officers and should be got approved by the Executive Engineer before use on works.

1

-

-

... More
Supplying and fixing of best quality 40mm MS Clampset (heavy) including bolt nut, etc., complete complying with standard specification and as directed by the detpartmental officers.

1

-

-

... More
Supply suitable PVC End Cap (6kg/sqcm) of best for casing pipe of 6" dia borewell quality with ISI mark, The PVC should got approved by the departmental officers.

1

-

-

... More
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth as directed by the detpartmental officers.

1

-

-

... More
Supplying and fixing SFRC Manhole cover with size 600 x 600 mm including necessary fitting as per manufacturer requirement etc.

2

-

-

... More
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of 50mm thickness in RCC 1:2:4 (one cement, two sand and four aggregates), using 20mm HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed

89

-

-

... More
Supplying and filling 40mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers

6

-

-

... More
Supplying and filling 20mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers

6

-

-

... More
Supplying and fixing in position best quality approved make White Porcelin Sink of size 600mm x 450mm x 200mm including cost of 32mm dia 'B' Class G.I. waste water pipe and 32mm dia C.P. waste coupling., 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Executive Engineer before use on works]

15

-

-

... More
Supplying and fixing of SS Sink of size 1200x550x180mm etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.

3

-

-

... More
Supplying and erecting in position of of following capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No. Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.

-

-

-

... More
50 Litres Capacity

6

-

-

... More
500 Litres Capacity

4

-

-

... More
Supplying and fixing of PVC ready made WATER TANK of 1000 Litre capacity of best and approved quality with ISI specification and having inlet,outlet, overflow and clearing pipe arrangements and labour charges for fixing in position with all necessary accessories and transporting at site of work etc., complete complying as directed by the departmental officers.

12

-

-

... More
Manufacturing, supplying and fixing in positon of RCC Jally of 5cm thick in cement concrete 1:2:4 using 20mm machine crushed stone jelly (excluding cost of reinforcement steel) including cost of mould, finishing, curing, lifting, fixing in position etc., complete complying with standard specification and as directed by the departmental officers.

365

-

-

... More
Providing GRANOLITHIC FLOOR finish of 25mm thickness with Plain Cement Concrete 1:2:4 [One Cement, Two Crushed Stone Sand and Four Aggregate] using 10 to 12 mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc., complete complying with standard specification and as directed by the departmental officers. [The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers].

209.5

-

-

... More
Supply and fixing of best approved best quality Incinerator for Ladies Bathroom etc., complete complying with standard specifications.

3

-

-

... More
Supplying and Erecting of Electrically Operated Type (exceeding 12 sqm. Area) Pull and Push Type Rolling Shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc as directed by the Departmental Officers.ROLLING SHUTTERS (WITH ISI MONOGRAM)

15.5

-

-

... More
ELECTRICAL ITEMS:

-

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End )

577

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End.

125

-

-

... More
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End.

12

-

-

... More
Supply and fixing of 1no.6A two module 5pin socket, 1no. 6A one module switch with module cover plate (plastic) on suitable module surface mounting Box (GI) on wall with connections.Higher End.

14

-

-

... More
Supply and fixing of 7W/9W LED Lamp for BH point.

46

-

-

... More
Supply and fixing of 4'20W LED Tube light fitting with Batten (Make : Higher End) with TW round blocks on wall or ceiling with LED tube with PVC unsheathed Copper leads from terminals to the fitting.

105

-

-

... More
Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.

233

-

-

... More
Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.

84

-

-

... More
Supply and fixing of 1200mm (48") sweep BLDC ceiling fan complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp.

190

-

-

... More
Supply and fixing of 300mm (12")sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall.

48

-

-

... More
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan.

48

-

-

... More
Supply & Fixing of AC / DC 76mm Buzzer /call bell suitable for 230 Volts 50 c/s single phase AC supply on suitable TW Board with push switch.

3

-

-

... More
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .

8

-

-

... More
Supply and fixing of 65 mm dia. (2 -1/2") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour.

4

-

-

... More
Supply and laying of 4 x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.

120

-

-

... More
Supply and clarnping of 4 x 10 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.

30

-

-

... More
Supply and fixing of brass cable gland for 4 x 10 sq.mm. PVC armoured LTUG cable with earth connection.

8

-

-

... More
Supply and fixing of WT bulk head fitting with guard and 15W LED bulb.

16

-

-

... More
Supply and fixing of 3Nos. 6A two module 5pin socket, 3nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End.

46

-

-

... More
Supply and fixing of 1No. 6/16A two module socket, 1no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End.

40

-

-

... More
Supply and fixing of 3nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (In Various Ward).

109

-

-

... More
Supply and fixing of 2nos.6/16A two module socket , 2 nos. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End

9

-

-

... More
Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection.[For AC Plug].

21

-

-

... More
Supply and fixing of 1000W automatic electric water heater of 25 litres capacity suitable for 230V 50 c/s AC supply on suitable MS clamps with 3 core flex wire,but without plumbing work.

4

-

-

... More
Supply and fixing of 8way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCB switch as incoming and 6nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End.

26

-

-

... More
Supply and fixing of 12way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCB Switch as incoming and 10nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.

12

-

-

... More
Supply and fixing of vertical type 4 way triple pole neutral MCCB DB in sheet steel enclosure double door metal cover with IP 43 protection with 1No. 125A FP MCCB with Spreader Terminal as incoming and 4Nos. 63A TP MCB as outgoing with suitable cable end box in flush with wall and making good of the concealed portion with earth connection. The MCB DB, MCCB and MCBs should be with ISI mark and Higher end.

7

-

-

... More
Supply and fixing of 7Segment 4way TPN MCB Sheet Steel Distribution Board with metal/acrylic door cover flush type / surface type fitted with busbars and neutral links with single or three phase MCB outgoings and seperate 4way provision for accomodating 1No 4Pole incoming MCB/Isolator and another seperate 4Way provision for accodating 1No. 4Pole ELCB/RCD (Totally 8ways in one segment)(3x4 ways in each segment )and seperate provison for MCB/Isolators (Totally 12 Nos) for sub incomers in 3 segments with label holder an provison for taking of cable for size not less than 35 sq.mm with the following in flush with wall earth connection only. 1) 63A 4P MCB - 1No 2) 63A 4P 30MA RCCB/ELCB-1No 3) 63A DP MCB Isolator - 3Nos 4) 6A to 32A SP MCB - 12Nos (SD-627) (For Lighting & Power in Each Floor)

21

-

-

... More
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion [For 3x6A Computer Plug, UPS Line].

1000

-

-

... More
Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion. [For 20A MC Plug,Socket 16A Power Plug and Set Plugs]

3000

-

-

... More
Supply and Run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion. [For 8W SPNMCB DB and 12W SPNMCB DB]

950

-

-

... More
Supply and Run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 6 sq.mm copper wire and making good of the concealed position.(4W 7S TPN MCB DB for lighting & Power)

40

-

-

... More
Supply and Run of 4 of 16 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 sq.mm copper wire and making good of the concealed position.(4W 7S TPN MCB DB for lighting & Power)

600

-

-

... More
Supply and Run of 4 of 25 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire with painting of suitable colour.(4W TPNMCB DB for Lighting and Power)

200

-

-

... More
Supply and fixing of 63A TPNMC switch with suitable angle iron frame work with MS cable entry box with earth connection only. (For 2Nos Lift Control Switch, and 1No Pump set)

3

-

-

... More
Supply and fixing of 1 No. 63A Four pole MCB with 1No. 63A 30mA 4P ELCB in modular 8 way waterproof enclosure in flush with wall with earth connection [Higher end] (For OT1 and OT2)

2

-

-

... More
Supply and fixing of 32A FP MCB in Metal box FP enclosure in flush with wall and making good of the concealed portion with earth connection. (Higher End make) (Autoclave and AC Indoor)

4

-

-

... More
Supply and Fixing of 16A Two-way switch in suitable Modular type GI box on wall with suitable front cover plate with earth connection (Higher End) (For Lift well lighting Control)

4

-

-

... More
Supply and run of 3 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour. (For Lift Well Light Control).

100

-

-

... More
Supply and fixing of 125A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only.

1

-

-

... More
Supply and fixing of 100A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only.(In X Ray ).

1

-

-

... More
VCB Panel : Design, manufacture, testing at works, transportation to site, unloading, storing, erecting, testing & commissioning of 22KV,800A,50KA SINGLE VCB PANEL (OUTDOOR TYPE) of Floor mounting type, undrilled gland plates at bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for HT panels & comprising of the following. Incomer Cum Out going : 1Set - 22kV, 800A 50KA Draw out type TP VCB with Spring Charging Motor & Close/ Trip Coil Each set comprising of following CT's for metering - 100-50A/5A - 5A, Cl 0.2s, 15VA CT's for protection - 100-50A/5A - 5A, Cl 5P15, 15VA Line PT - 3phase 3 Limb 33kV/v3/110V/v3, Cl 0.5, 100VA (Drawout type) Bus PT with HT fuse for protection in separate chamber Breaker T/N/C switch Protection relay for 51,50, 51N, 50N, 95, 27,59, 86 (All relays shall be numerical type with all built in standard features for protection, recording, event logging, etc.) 22KV, 50KA surge arrester

1

-

-

... More
Metering with Two RS-485 ports interface with Load Manager (EM 3460), Digital type Ammeter, Voltmeter & KWHr 110V AC / 110VDC Power pack with continuous & stored energy R,Y,B,ON,OFF, Trip,CB spring charge, trip circuit Healthy indication Lamps (LED)- 110V AC Push button for trip circuit healthy, Emergency trip Space Heater with switch & thermostat, Power outlet with switch 20A Plug & Socket with control by 20A SPN MCB, lamp with door switch. 12Window Annunciator with RS 485 CBCT with Relay BusBars 630A TP Copper bus bar of current density does not exceed 1.2A/sq.mm, color coded with paint/heatshrinkable sleeves. Joints to be tinned. Note : Incoming & Outgoing busbar shall be extended

-

-

-

... More
TRANSFORMER: Supply, erection, testing and commisioning of 500kVA, 22kV, 433V, HV-Delta, LV-Star of load tap changing, copper wound, outdoor type, distribution transformer as per IS 1180 (Level-II) ON AN cooled, conforming to relevant IS 1180/IEC 60076, Level-II class A Insulation and mounted on 300x90x6mm base channel bolted to a suitable RCC plinth of height 3' and RCC foundation to a depth of 2' with reinforcement by suitable MS rods 150kg/m3 capable of bearing 2ton weight and connected works fitted with the following: 1) HT cable end box suitable for connection of 22kV 3C x 240 sq.mm HT cable & LT cable and box suitable for connection with 3 runs of 3 ½ x 400 sq.mm LTUG cable. 2) Bucholtz relay with shut off valve, alarm and trip contacts. 3) Dehydrating Silica gel breather. 4)Conservator with oil filling pipe, cap and drain plug valve. 5) Tank drain cum bottom fitter valve with plug. 6) 4nos. plain rollers uni and bi-dirctional under base channels with skid. 7)Dial type thermometer with pocket to measure oil temparature stem type. 8) Tank top filter valve with plug. 9). Explosion vent wih diaphragm. 10) Oil level gauge with marking. 11). Two body earthing terminal and additional neutral bushing for solid earthing. 12). Rating and Terminal marking diagram plate. 13). Lifting hooks/Lifting eyes/Jacking pad to facilitate easy movement of Transformer to ground level, cover lifting lugs. 14). Off load hand operated tap changing switch at standby height from ground level.

1

-

-

... More
15). Tapping on primary winding for voltage variation ±5% in steps of 2.5%. 16). Welded and detachable radiators. 17). Air Release device. 18). The Transformer should be supplied with first filling of oil as per IS 335 with high dielectric strength, BDV and flash point. 19).Monogram plate. 20) shut off valve for surge relay. 21). Oil surge relay. 22). All removale covers shall be provided with weather proof hot oil resistant, resistance gaskets to prevant leakage of water into core, and oil from the tank with low no-load loss 1100W and full load loss 6400W, impendence 5% with temparature rise oil / winding 50°C - 55°C [Make: Kirloskar electric company / CREL / Rowsons or equivalent].

-

-

-

... More
Supply and erection of Double pole 22 KV H.T Structure of 33 feet 200 x 100x5.7mm R.S Joist with 10 feet centre to centre on either side with necessary MS angles ,cross branching and mass concreting of poles to received the 11 KV supply with following HT accessories complete as per Central Electricity Authority (measures relating to safty and electric supply ) regulation a) 2 Nos, 33 feet length, 200x100x5.7mm R.S Joist poles and base plate of 300x300x6mm with concreting and coping. b) One set of 1Nos 22KV lighting arrester mounted on suitable channel iron size 4”x2”x1/2” complete. c) One sets of 1 Nos. 22 KV pin insulator fixed on suitable channel iron from work complete for supporting copper jumper. d) One set of 3 Nos. 22 KV DO fuses complete with insulator on channel iron support. e) Two nos. of stay arrangements with guyshakle insulators with necessary masonry work . f) Supply and fixing of required cross bracing made of size 2 ½ x 2 ½ x ¼ “ MS angle to keep the structure balance. g) Supply and fixing of required cross bracing made of size 2 ½ x 2 ½ x ¼ “ MS angle to keep the structure balance.

1

-

-

... More
h) Providing H.T connections and jumper connections from supply point to the 2 pole structure with ACSR conductor / Zero HDBC conductor for giving necessary connections and jumpering from 22 KV strain Disc insulators to AB switch operating rod, AB switch to lighting arrestor, and DO fuse through insulators, and G Fuse to post top insulators and pin insulators complete with colour coding. i) Supply and fixing of 2 Nos. 22 KV metal danger boards. j) Painting the structure complete with primary coat of red oxide and two coats of alu. paints. k) Fencing: supply and Fixing of fencing with 10 SWG GI chain link fencing of size 10mm x 10mm, 10 SWG lacing with MS post of size of 50mmX50mm with suitable channel/ stiffeners at the top of the chain linked fencing provided around the TANGEDCO's DP structure yard and the SS yard at point of supply and the lacings fastened to the top channel with painting of complete strcuture with a primary coat of red oxide and two coat of good make aluminium paint and etc as directed by the departmental site officers.

-

-

-

... More
Supply and laying of 22KV 3c x 185 sq.mm HT Three Core Power Cables - Aluminium Conductor Compact Circular Aluminium Conductor, XLPE Insulated cable in a trench to be excavated at a depth of 1 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.

20

-

-

... More
Supply and providing cable end termination suitable 22KV 3 core 185 sqmm XLPE HT UG cable with necessary outdoor type heat shrinkable Termination kit and accessories with termination complete.

4

-

-

... More
MV Panel: Design, Supply, Erection, Testing & Commissioning of sheet steel enclosed, Dust & Vermin proof, 800A Single tier MV ACB Floor mounting cubicle panel made up of 1.6mm CRCA sheet steel with powder coating, segration of incoming & outgoing feeders should be with necessary clearence to terminate the outgoing cables with suitable capacity, necessary SMC. Bus bar insulator supports, base frame of 75mm x 50mm x 3mm with black colour paints, all Busbars insulated with RYB coloured heat shrinkable sleeves busbars joints are duly tinned, necessary GI bolts nuts washers and spiring washers etc., following switch gears & feeders. E.B Incoming: 800A FP EDO ACB, shunt & UV Release - 1no, E.B. Incoming metering; 96 sq.mm Digital type Multifunction meter - 1no (VIF&KW, P.F, Demand controller. Earth fault relay - 1no, RYB indication lamps-1no. E.B Bus coupler: 800A FP Isolator - 1nos. EB and Generator Busbar: 1"x½"x 2Runs copper flat per phase, 1"x½"x 1Run copper flat neutral D.G.Incoming 800A FP EDO type ACB with shunt Release & UV Release - 1no. DG Incoming Metering, 96 sq.mm Digital type Multi function meter -1no (VIF&KW, P.F, Demand controller. Earth fault relay - 1no, RYB indication lamps-1no.

1

-

-

... More
OUTGOING: 400A FP SDF Double Break switch with DIN Type fuse units - 2nos. 400A TP SDF Double Break switch with HRC Fuse units - 2nos. 200A TP SDF Double Break switch with HRC Fuse units - 1no. 125A TP SDF Double Break switch with HRC Fuse units - 1no. 63A TPN switch (SDF) double break with HRC Fuse units - 6 nos. All Bus bar supports by using MS supported SMC insulating materials. Joints: All Bus bars joints tinned and galvanized bolt nuts with plate & spring washers. INTERLOCKING ARRANGEMENT: Both the EB & DG incomers, Bus couplers mechanically interlocked with three lock two key systems. The interconnection with the bus bars to the 800A ACB and 800A ACB should be done by using 1"x½"x2 runs of Copper flat. The interconnection with the bus bars to the 800A FP SDF DB switches should be with 1"x½"x2 runs of Copper flat and that for 400A SDF DB Switches with 1"x½" Copper flat and that for 250A SDF DB Switches with 30mmx6mm Copper flat and that 125A SDF DB Switches with 30mmx3mm Copper flat and 63A SDF switches with Nos.8 SWG Copper conductor. And Double earth connection to all the switches should be done using No.8 SWG Copper conductor. The buses should be mounted on the SMC bus insulator at proper & sufficient spacing between the buses as per IE rules.

-

-

-

... More
The bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of 6mm thick as partition. 1"x1/8"copper flat should be provided all around the panel for earth connection. Phase & Neutral copper buses should be provided with heat shrinkable sleeves using RYB & Black colours. Indicator lamps should be provided with toggle switches & Bakelite fuse unit.The capacity of fuse switches, size and route location of the UG cable shall be superscribed on all the incoming and outgoing switches. The Panel should be mounted on angle iron frame work of size 1½"x1½"x¼" MS channel provided all around the sides of the panel. The whole arrangements should be erected on a suitable masonary pedastal. (All Switches and ACBs should be with ISI mark and of Higher End make only)

-

-

-

... More
APFC PANEL Design, Supply, Erection and testing of 75kVAR, 415Volts, 50Hz, 3phase, 12 stage switching sequence power factor correction Floor mounting dust and vermin proof cubicle panel board made of 16SWG CRCA sheet steel with 1 1/2 " x 1 1/2" 1/2" AI Frame work with RCC concreting foundation and bolted to masonry pedastal with supply and fixing of the following interior mounting capacitor chamber, Solid state relays with TM2 technology, with metering chamber and compartmentalised outgoing feeders with suitable capacity MCCB of 400A rating with rotary handle for incoming, with provision for louvers and cooling fan for proper ventilation to manage heat load. Outgoing capacitor bank consits of 12 stages with MPP Capacitors ranging from 2kVAR to 30kVAR as detailed below: 1.stage - 2KVAR 2.stage- 3KVAR 3.stage- 5KVAR 4.stage- 10 KVAR 5.stage- 10 KVAR 6.stage- 15KVAR 8.stage- 30KVAR Bus bar: 2run of 50mm x 6mm tinned copper Metering: 1) 0-500A Ammeter with CT coil 2) 0-500V Voltmeter 3) R, Y, B indicators

1

-

-

... More
4) Advanced micro controller based intelligent power factor controller with self diagnostics sensing and digital network analysis with software for momentary and saving parameter using a suitable multi-function meter and display to show the following parametes. a.Vr-R Phase Voltage b.Vy-Y Phase Voltage c.Vb-B Phase Voltage d. Ir-R Phase Current e. Iy-Y Phase Current f. Ib-B Phase Current g. kW - Present Kilo watts h. RkVA - Present Reactive kVA Demand i. kVA - Present kVA j. pf - Present Power Factor k. Number of capacitor bank ON/OFF l. Provision of indicate the imbalanced load m. Provision to indicate the change in phase sequence n. The APFC Panel should also have built in protection for current imbalance. o. High voltage / low voltage cut off, single phase preventer, provision for inductor coil to cater in-rush currents, line surges, current limiters, current sensor, etc, with connection complete and as per the relavant IE rules.

-

-

-

... More
Supply and Laying of 3 ½ x 240 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. [From new MV Panel to Existing 400APanel and existing CT Scan]

214

-

-

... More
Supply and clamping of 3½ x 240 sq.mm PVC LTUG armoured LTUG cable armoured Pipe on post or on wall with MS Clamps.

20

-

-

... More
Supply and fixing of brass cable gland for 3½ x 240 sq.mm PVC armoured LTUG cable, with earth connection.

4

-

-

... More
Supply and providing cable end termination of 3 ½ x 240 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.

4

-

-

... More
Supply and laying of 3Rx 3 ½X 400 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15mtr Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good [from Transformer secondary side (From LV to MV panel)

20

-

-

... More
Supply and clamping of 3R x 3 ½ x 400 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (from transformer secondary (From LV to MV panel).

15

-

-

... More
Supply and fixing of brass cable gland for 3 1/2 x 400 sq.mm PVC armoured LTUG cable, with earth connection.

6

-

-

... More
Supply and providing cable end termination of 3.5 x 400 sq mm PVC LTUG Aluminum armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.

6

-

-

... More
Supply and laying of 2Rx 3 ½X 185 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15mtr Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good [from Transformer secondary side (From MV panel to Rising main and for 250KVA Genset).

300

-

-

... More
Supply and clamping of 2R x 3 ½ x 185 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (from transformer secondary (From MV panel to Rising main and For 250KVA Genset).

70

-

-

... More
Supply and clamping of 3 ½ x 185 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (from transformer secondary (From Rising main to 250A Panel)

130

-

-

... More
Supply and fixing of brass cable gland for 3 1/2 x 185 sq.mm PVC armoured LTUG cable, with earth connection. (From MV panel to Rising main-4Nos,From MV panel to 250KVA Genset-4Nos,From Rising main to 250A Panel-12Nos)

20

-

-

... More
Supply and providing cable end termination of 3.5 x 185 sq mm PVC LTUG Aluminum armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.

20

-

-

... More
Supply and laying of 3½ x 70 sq. mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75metre putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (For new CT Scan)

120

-

-

... More
Supply and clamping of 3 ½ x 70 sq.mm PVC LTUG armoured cable on post or on wall with MS Clamps.

20

-

-

... More
Supply and fixing of brass cable gland for 3½ x 70. sqmm PVC armoured LTUG cable with earth connection.

2

-

-

... More
Supply and providing cable end termination of 3½ x 70 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.

2

-

-

... More
Supply and laying of 3½ x 50 sq. mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75metre putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (For Xray)

40

-

-

... More
Supply and clamping of 3 ½ x 50 sq.mm PVC LTUG armoured cable on post or on wall with MS Clamps.

20

-

-

... More
Supply and fixing of brass cable gland for 3½ x 50. sqmm PVC armoured LTUG cable with earth connection.

2

-

-

... More
Supply and providing cable end termination of 3½ x 50 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.

2

-

-

... More
Dump Lift Design, Engineering Supply, fabrication, erection, testing, Commissioning and handing over of 1No. Dump Waiter lift as per following Technical Specification. 1. Type of Lift : Dump Waiter lift. 2. Capacity of Lift : 500Kgs. 3. Speed : 1 Metre / Sec. 4. Type of Drive : Single speed Drive 5. No. of Floors : Stilt +5 Floors. 6. Total Travel : 24 Metres. 7. Over Load warning Indicator and fireman’s Switch to be provided. 8. Design of Car : M.S. Painted with M.S. chequered plate flooring. 9. Position of Machine : Directly above the lift shaft. 10. No. of Landing Entrance : One in front Total 2 Nos. 11. No. of Car Entrance : Two. 12. Car Entrance Door : Two Doors. 13. Landing Entrance Door : Collapsilble gate M.S. painted with landing door frames. 14. Servicing and maintenance : Free comprehensive Servicing and maintenance during the guarantee period of one year. 15. Lift License : Preparation of drawing, payment of charges to CEIG / Lift inspectorate and insurance polices if any anf obtaining CEIG safety certificate as per lift act.

1

-

-

... More
16. Special Feature: (a). “UP and DOWn arrows in landings only. (b). Steel Cubical for Controller. (c). M.S. Door frames for Landing Entrance. 17.Supply of Operation and Maintenance manual with necessary tools for operation. The list of Tools should be furnished by the contractor in a separate sheet duly signed. 18.Other Standard Features: Phase failure and phase reversal relay, T-guide brackets for car and counter weight, rubber padding under winding unit, Motor of adequate capacity single reduction warm gear, electro mechanic brake with compression springs with car safety gear, buffer machanical door locks, emergency key, side supporting angles motor over load protection devices. Final limt switch, main suspension ropes, counter weights, lifting joist for mounting the machineries.

-

-

-

... More
LIFT Design, Engineering, Fabrication, Supply, Erection, Testing, Commissioning and handing over of 20Persons capacity Passenger cum bed lift (Gearless Lift with Machine Room) complete with the following specifications Complete set for patient utilizations. I. General Number of Lift : 1 No (a) Capacity and type 20Persons (1360kg) Capacity Passenger cum Bed lift. (b) Speed : 1 Mtr / Sec. (c) Drive : Micro Processor based VVVF (d) Size of Lift well : 2300 x 3000 (mm Wide x mm Depth ) as per IS 14665 (part I) 2000 to be constructed by PWD civil wing. (e) No. of floors : 6( Six )(Ground + 1 st floor + 2 nd floor + 3 rd floor + 4th floor + 5th floor) (f) Total height of Travel : 19 metres / Pit 1600 mm / Head Room 5100mm. (g) No.of stops : 6( Ground + 5Upper Floor) (h) No.of opening :6 ( Ground +5Upper Floor) (i) Construction of lift well : R.C.C. with brick masonry.

1

-

-

... More
(j) Power supply : AC 415/ 440 Volts, 3 phase, 50 Hz. (k) Auxiliary supply :230V, AC supply ( Single phase ) (l) Position of machinery : Directly above the lift well. (m) Lift pit depth : 1600mm (n) Leveling accuracy : High level accuracy with smooth & jerk free travel and stopping. II. CAR a. Size of Lift Car inside : 2400mm x 1300mm x 2200mm (MM Wide * MM Depth * MM Height) b. Design of lift car: 1.5mm Stainless Steel HAIR-LINE Finish c. Car ceiling : SS False-ceiling. d. Car floor : Granite / Marble flooring. e. Car fittings : 220V AC electric cabin fan 300mm swing (2Nos) and LED fittings. f. No. of Opening : One ,in front only g. Car Entrance : One in front only. Power operated V3F Drive, Side opening sliding stainless steel (1.5mm) Hair-line Finish Door. h. Clear opening : 1200 x 2000 (mm Wide x mm Height ) b. Landing Entrance Doors: Side opening sliding stainless steel (1.5mm) Hair-line Finish Door with provision for Emergency Exit key at all Landings.

-

-

-

... More
IV. OPERATION Microprocessor based Simplex Selective Collective control with / without attendant. V. Car and Landings : Digital floor position indicator in car and all landing. Dry cell operated alarm bell and emergency light with Automatic charging device, Up / Down Digital direction indications at all landings and in car. VI. LADDER FOR LIFT MACHINERY To be provided by the Lift contractor. VII. SPECIAL FEATURE : Digital position indicator in Car and landings. Battery operated Emergency light and Alarm bell, call register signal and V3F Door operator, false ceiling in Car. Infra red door screen, Vandal proof SS Button with SS cover, Automatic Rescue Device Fire mans switch, over load indicator and Intercom provisions with Instruments and floor Annuciator. SS hand rails and ON/OFF key and free service for 1year.

-

-

-

... More
VIII. Automatic Rescue Device ( ARD ) : To facilitate landing of lift to the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger, inverter, under voltage protection system etc. complete with all accessories. IX. MINOR BUILDER WORK : To be done by the lift contractor. X. SCAFFOLDING WORKS : To be done by the lift contractor. XI. FREE SERVICE AND MAINTENANCE a. Guarantee : Guarantee for materials and workmanship of equipment not less than one year. b. Free maintenance : Free comprehensive servicing and maintenance during the guarantee period to be provided by the Lift contractor for 1year. And important necessary training of employees for minor maintenance works and proper handing over of lift to be done by the lift contractor. c. Preparation of Drawings and obtaining CEIG's Safety Certificate for lift approval as per lift act with payement of necessary fees to CEIG and insurance policies, If any applicable to lift.

-

-

-

... More
d. Site tests in accordance with IS 14665 shall be carried out at time of handing over. XII. OTHER INCLUSIONS : Over speed Governor, phase failure and phase reversal relay, alarm bell, T. Guide brackets for car and counter weights, rubber padding under winding unit, Motor of adequate capacity, electro magnetic brake with compression springs, car safety gear, buffer, electro mechanical door locks, tubular S.S hand rail in car. Steel ladder for machine room, Emergency key, motor over load protection devices, final limit switch, position and direction indicators for car and landing entrances, main suspension ropes, counter weights, lifting joists for mounting the machines S.S. fascia plate for car operating panel & landing fixtures, fireman's switch and other necessary controls, Overload Warning indicator with audio annuouncer, etc.. complete. Site Testing in accordance with IS14665 should be carried out at the time of Handing over to the user department. Supply, operation and maintenance manual and necessary tools for operation and a set of spare parts required for 1 year to be provided. (Make : Johnsons / KONE / OTIS / Equivalent)

-

-

-

... More
Supply and clamping of 3 ½ x 25 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.(for Lift)

60

-

-

... More
Supply and fixing of brass cable gland for 3½ x 25. sqmm PVC armoured LTUG cable with earth connection. (for Lift)

4

-

-

... More
Supply and providing cable end termination of 3½ x 25 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.(for Lift)

4

-

-

... More
Supply and demonstration of safety accessories AC Chargeable Emergency Lamp 2 x 11W PL Lamp with all connected accessories.

1

-

-

... More
Supply and demonstration of safety accessories 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS.

5

-

-

... More
Supply and demonstration of First Aid Box complete with all First Aid Medicines.

1

-

-

... More
Supply and demonstration of Shock Treatment Chart fixed in glass frame in Tamil and English.

1

-

-

... More
Supply and demonstration of safety accessories 4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle.

1

-

-

... More
Supply and demonstration of Hand Gloves 11KV Grade.

1

-

-

... More
Supply and fixing of Danger Board as required by the Electrical Authorities.

1

-

-

... More
Supply and demonstration of safety accessories Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms.

1

-

-

... More
Supply and demonstration of Earth Discharge Rod.

1

-

-

... More
Preparation of site plan, physical layout, electrical line schematic diagram in 10 sets getting drawing approval from CEIG preparation of completion report, rectification report and arranging CEIG inspection and obtaining safety certificate preparation of 1 set of approved drawing and acopy of safety certificate in a neat frame work to be fixed in generator room and payment of CEIG inspection fees.

1

-

-

... More
Supply erection testing commissioning of 2.00TR (6000 KCal/Hr) ABS Plastic split type Air Conditioner conforming to IS1391[Part 2] 1992 with Rotary compressor operating on refrigerant Non CFL suitable for wall mounting for operating on 230V 50HZ single phase AC supply with Three star rating Model as per BEE Specification and capable of performing the following functions.A) Cooling, B) dehumidifying C) Air circulating D) Filtering the installation work for the above split type AC units includes the following. 1. Mounting /fitting indoor and outdoor units at their respective locations. 2. Laying refrigerant pipe line of 6mtrs distance and connecting both units after drilling hole in the wall if required thickness of the copper tubing shall not be less than 0.80mm 3. Insulating the suction pipe with expanded polythene foam 5mm thick tubing. 4. Laying 15mm dia flexible PVC drain pipe of 6mtrs length to throw out the condensate water being formed in the indoor unit. 5. Leak testing the entire gas unit. 6. Charging refrigerant gas in the unit. 7. suitable electric wiring to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 4mtrs length and up to switch within 3mtrs of location of indoor unit.(Higher End)

19

-

-

... More
Supply and fixing of 5KVA Automatic voltage stabilizer of wall mounting type with Automatic time delay switching arrangements suitable to operate on 230V Single phase supply.

19

-

-

... More
Supply and laying of 5/8'' and 3/8'' copper pipe (Extra beyond 3Mtrs supplied with AC Unit).

150

-

-

... More
Supply and fixing of MS Stand for fixing outdoor unit.

19

-

-

... More
Supply and run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.

150

-

-

... More
RISING MAIN Aluminium: Supply erection, testing and commissioning of 400A 3L+N+PE, Plug in TYPE, 415V 3 Phase and Neutral sandwich Aluminium bus bar rising main indoor type totally dust and vermin proof with Insl F with suitable GI enclosure of 1.6mm thickness with epoxy painting of RAL7032. Rising main shall be provided with double aluminium earth bus bar of capacity as per specification for the entire length and cost of earth bus bar shall be included. short circuited rating of 40KA for 1sec with necessary rigid hanger, spring hanger and wall support hanger. The detailed drawing shall be approved by the department before manufacturing.

45

-

-

... More
Supply, Erection, Testing and commissioning of 400A END Feed unit with 400A 4P electronic release MCCB 50kA for 400A Rising mains.

2

-

-

... More
Supply and fixing of Flange end for 400A rising main

2

-

-

... More
Supply, Testing and commissioning of tap off boxes of the following rising main including interconnecting rising main of 125A 4P MCCB suitable for terminating with 3.5C x 70 sq.mm cable (Higher End).

12

-

-

... More
Supply ,installation , testing and commissioning of 8.5TR factory assembled double skin AHU with 100mm -45kg/cum PUF Insulated detachable panels ,extruded thermal break aluminium profiles filled with PUF,panel external skin with 0.6 mm preplasticized sheet, panel internal skin with 0.6mm galvanized sheet, AMCA tested DIDW backward/ forward curved centrifugal fan with EFF1 rating motor, drive arrangement with taper lock pulleys for fan and motor, vibration isolators out of heavy duty rubberized mounts, prefilters with 3ply HDPE 50mm thick filters having an efficiency of 90% 10 Micron and 5 Micron, 6row /12FPI deep DX copper cooling coil with copper header and aluminium fins, GI mist arrestor, condensate coil trough with SS-304-20G insulated with 9mm closed cell elastomeric foam, guard for inspection door, out let damper of aerofoil blades & PVC gears, and flexible fire retardant canvas complete with galvanized hardware. Each of the cooling coils will have independent distributers, electronic expansion valve kit, catch all drier, independent DX coil circuit to connectivity to each ODU circuit. Appropriare devices to be installed to monitor the Temperature, Humidity and Diff. Pressure inside the Operation Theatre.(Higher End)

1

-

-

... More
Supply ,installation , testing and commissioning of 11.0TR factory assembled double skin AHU with 100mm -45kg/cum PUF Insulated detachable panels ,extruded thermal break aluminium profiles filled with PUF,panel external skin with 0.6 mm preplasticized sheet, panel internal skin with 0.6mm galvanized sheet, AMCA tested DIDW backward/ forward curved centrifugal fan with EFF1 rating motor, drive arrangement with taper lock pulleys for fan and motor, vibration isolators out of heavy duty rubberized mounts, prefilters with 3ply HDPE 50mm thick filters having an efficiency of 90% 10 Micron and 5 Micron, 6row /12FPI deep DX copper cooling coil with copper header and aluminium fins, GI mist arrestor, condensate coil trough with SS-304-20G insulated with 9mm closed cell elastomeric foam, guard for inspection door, out let damper of aerofoil blades & PVC gears, and flexible fire retardant canvas complete with galvanized hardware. Each of the cooling coils will have independent distributers, electronic expansion valve kit, catch all drier, independent DX coil circuit to connectivity to each ODU circuit. Appropriare devices to be installed to monitor the Temperature, Humidity and Diff. Pressure inside the Operation Theatre. (Higher End)

1

-

-

... More
Supply and fixing of Laminar Air flow Plenum for SS304 - 1.0 mm Thich casing, Mini Pleat Hepa Filters for 100mm Thick- Flange type, OT Pendant Light provision for 600X600, With SS304-1.2mm Thick perforated sheet. PLENUM SIZE: 1800L X 2400W X 350HHigh Efficiency particulate Air (HEPA) filter specification: Filter Size : 8 feet x 6 feet x 1 feet Classification : H-13 Construction :Panel Type Efficiency :99.97% Optical efficiency at .3 micron Cleanliness level: Class 100 As per NABH Standard Spacers: Aluminium Initial pressure drop:25 mm W.C Final pressure drop : 75 mm W.C Duct holding capacity:4750gm/Sq.mtr Framing :Aluminium (Box type) Washable : No Test reports to be furnished from approved Government External Quality Assurance Lab/ Agency to meet the testing parameters after commissioning of the AC system with HEPA filter as per NABH standards.

2

-

-

... More
Supply and filling of non-CFC Refrigerant Gas.

27

-

-

... More
Supply & fixing of hard drawn copper Refrigerant piping of suction line of Size 7/8” inches with necessary fitting and clamp etc.

20

-

-

... More
Supply & fixing of hard drawn copper Refrigerant piping of liquid line of size 5/8” inches with necessary fitting and clamp etc.

20

-

-

... More
Supply and fixing of flexible canvas connection between indoor unit and ducting and rubber pads, with ceiling Support angle rods etc..

2

-

-

... More
Supply and fixing of 50mm thick anti vibrating rubber pads.

8

-

-

... More
Supply, Fabrication and Installation of 22 G Aluinium Sheet Ducting for both suction and Return arrangement insulate with for Operation Theatres with inter linking arrangements with necessary angle supports, anchor fasteners and threaded rods etc... as required.

80

-

-

... More
Supply and Providing Thermal Insulation of 9mm thick Class ‘O’ Fire Retardant –XLPE with aluminium foil.

50

-

-

... More
Supply & fixing of Acoustic insulation for Supply air duct using 10 mm thick class 1 rating Open cell nitrile rubber /XLPE insulation.

30

-

-

... More
Supply and fixing of powder coated Extruded aluminium supply air grilles/diffuser with MS volume control damper for supply.

4

-

-

... More
Supply, fabrication and fixing of Volume control dampers individually across the duct.

2

-

-

... More
Supply and fixing of 1 inch PVC water drain pipe line on wall with suitable Clamp as required.

30

-

-

... More
Supply, fabrication and fixing of suitable MS angle support frame for mounting the out door Units.

2

-

-

... More
Supply, fabrication and fixing of suitable MS angle support frame for mounting the in door Units.

2

-

-

... More
Supply and providing civil concrete block for mounting the air coditioning unit.

2

-

-

... More
Supply and providing of pipeline nitrile rubber insulation for suction line Refrigerant pipe as required.

60

-

-

... More
Supply and fixing of 32'' LED crystal UHD (Ultra HD) Smart TV With necessary set top box connections.(For Pay Wards)

6

-

-

... More
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.

122

-

-

... More
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.

50

-

-

... More
Earthing as per the ISI specification with an earth electrode of 2.1 mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.

30

-

-

... More
Supply and fixing of 5000VA UPS with 4Nos 12V 150AH tubular battery [Exide IT 500] with 1hour backup and 48months warranty for mentioned capacity on full load operation and the following features. [V- Guard/ APC/ equivalent] a) Inverter shall be free from workmanship defects, sharp edges, nicks, scratches, burs etc, all fasteners shall be fixed properly. The equipments shall be complete with all parts and all parts shall be functional. b) Enclosure shall conform to protection requirement of IRL to IS 13947 (part 1) 1993. c) Switching device shall be MOSFET (or) IGBT. d) Switching frequency shall be about 50HZ. II. Input ; 120V to 260V 50 HZ single phase AC III. Output : The variation in output voltage from NO- load to full load expressed as a percentage of no load voltage shall not exceed +1.5% over + 10 % and 20 % variation of the rated DC input voltage. The frequency of the output voltage shall be 50 HZ ± 1.3%. IV). Inverter efficiency minimum 85% as per CI.T.93 of ISS. v) Over load: inverter shall withstand 10% overload for at least 10 minutes. V).Protections.

3

-

-

... More
VI). a) When the Input voltage goes outside the range 120 volts and 260 volts the system shall switch over to inverter mode. b). Against over voltage, short circuit and over load at inverter output terminals. C). Battery reverses polarity. d). Protection against over discharge, The load shall be cut off as soon as the voltage of the battery terminal falls below. i) 10.5V for 12V and ii) 21V for 24V battery system. e). The inverter shall incorporate an arrangement for automatic change-over of load from main supply to the inverter AC output in case of failure of mains supply with correct pending indication as per CL; 5.6 of IS 13314/ 1992 f). inverter should have surge protection also VII indicators. a) Following indicators shall be provided. i) Mains presence ii) Mains mode. iii) Battery charging. iv) INVERTER MODE v) Battery low. 4 battery bank; 12 Volts lead battery to IS 7372(1995 ) with amdts.No1,2&3 shall be reputed makes with ISI. 9) Battery stand with wheel angle iron frame arranged. [For OT and ICU]

-

-

-

... More
GST @ 18%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.