Public Works Department Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date27 Nov 2024
Closing Date12 Dec 2024
Tender Amount₹ 3,96,80,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
In Foundation and basement

58

-

-

... More
Brick work in Cement Mortar1:6 ( one Cement and Six crushed stone Sand (M Sand) )using best quality of Country bricks 8-3/4" x 4-1/4" x 2-3/4" foundation and basement including curing, etc., complete complying with standard specification.

-

-

-

... More
Foundation and basement

121

-

-

... More
In Ground floor

160

-

-

... More
In First floor

199

-

-

... More
In Second floor

33

-

-

... More
Supplying and filling in foundation, basement, with Conveyed earth of 5KMMR in Layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

548

-

-

... More
Supplying and filling in foundation, basement, etc with Stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

127

-

-

... More
Supplying and filling with Crushed Stone(M-Sand) in layers of not more than 15 cm thick without consolidation etc. complete complying with standard specification and as directed by the departmental officers.

2

-

-

... More
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)

597

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)

-

-

-

... More
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.

2376

-

-

... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.

1277

-

-

... More
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance using 20mm with IS:456-2000, and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu'm') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
In Foundation and basement

266

-

-

... More
In Ground floor

182

-

-

... More
In First Floor

178

-

-

... More
In Second floor

14

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)

810

-

-

... More
Cement concrete 1:5:10 (one cement, five crushed stone sand (M Sand) and ten hard broken granite stone jelly) using 40 mm gauge hard broken granite stone jelly for flooring including consolidating rendering the top surface rough to recive the floor finish and curing etc., complete complying with standard specification.

91

-

-

... More
Brick partition walls using best quality of Country bricks 8 3/4" x4 1/4" x2 3/4" in Cement Mortar 1:3 (One Cement and Three crushed stone Sand (M Sand)) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)

-

-

-

... More
In Ground floor

24

-

-

... More
In First Floor

24

-

-

... More
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18/20mm above with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand (M Sand) ) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with matching colouring pigments etc Complete as Per Standard Specification., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.

1572

-

-

... More
Paving the floor with cement based hydraulically pressed anti skid tiles (pattern design) of 20 mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M. sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

92

-

-

... More
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M.sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

36

-

-

... More
Weathering course concrete using best quality broken brick jelly of size 20 mm uniform gauge in pure slaked lime in the proportion of brick jelly to lime being 32 to 12 1/2 by volume and laid over the RCC roof slab in a single layer and consolidated to the finished thickness by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling jaggery and lime water etc. complete complying with standard specification.

56

-

-

... More
Finishing the top of roof with one course of approved first quality machine pressed tiles of size 230 mm x 230 mm x 20 mm thick of approved quality laid in cement mortar 1:3 (one cement and three crushed stone sand)(M Sand) 12mm thick mixed with water proofing compound confirming to Indian standard specification as approved by the departmental officers at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same mortar mixed with the water proofing compound and red oxide etc. complete complying with standard specification.

679

-

-

... More
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick mixed with bonding agent cebex 112, zydex-zycrete 2X or other equivalent compound confirming to BIS at 200ml of 1 cement bag 50kg for increased workability and air entraintment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers

2834

-

-

... More
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick mixed with bonding agent cebex 112, zydex-zycrete 2X or other equivalent compound confirming to BIS at 200ml of 1 cement bag 50kg for increased workability and air entraintment used finishing in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.

4163

-

-

... More
Supplying and fixing in position both sides polished new cuddapah slab of 20/30mm thickness for cup-board shelf, urinal partition etc. including cost of slab, transportation charges in work site labour charges for forming grooves in masonry if necessary fixing the slab in position with CM 1:3 ( One cement and three crushed stone sand (M Sand) ) curing as directed by the departmental officers etc., complete.,

44

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing,conveyance, electrical charges, etc. complete

90

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance,welding charges, electrical charges, etc. complete

36

-

-

... More
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. ( 110 mm dia)

150

-

-

... More
Manufacturing supplying and fixing of steel door with the following specification MS angles of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door

-

-

-

... More
One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete. (Single Leaf Door of size 1.00 X 2.10 m)

-

-

-

... More
Single Leaf

6.3

-

-

... More
Manufacturing, supplying and fixing of steel doors with following specification. MS Angle of size 40x40x6mm at 3.5 Kg/m used for outer frame and MS Angle of size 35 x 35 x 5mm at 2.6 Kg/m for the shutter frame. Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided at required intervals in the Shutter frame and welded intact on both ends to the shutter frame. 18GCR Sheets of best quality is laid as panel in the shutter frames.18x5mm at 0.70 Kg/m MS Flat is welded over the 32x6mm @ 1.50 Kg/m MS Flat on the rear side of the door, sand witching the CR sheet for rigidity.

-

-

-

... More
Additional stiffeners with 18x5mm at 0.7 Kg/m MS Flats are provided diagonally on the rear side of the shutter. 3 Nos. of hinges in case of single leaf and 6 Nos. of hinges in case of double leaf shutters is provided. 6 Nos. of hold fasts 200mm length spliced at the ends are welded to the outer frame of the door. Tower bolt 2 Nos., one at the top and the other at bottom are provided. One aldrop is provided in case of double leaf door at lock rail section in the door. In single leaf doors, one more aldrop is provided in the inner side of the lock rail section

-

-

-

... More
of the door, one rotating locking arrangements locking arrangements for inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place in case of a double leaf door. MS Flat 32x3mm at 1.10 Kg/m is provided on the edge of the one shutter to conceal the gap between the two shutters. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete.

-

-

-

... More
DoubleLeaves

50.5

-

-

... More
Manufacturing, supplying and fixing in position of Steel Sheeted windows with the following specifications. Outer frames of windows made of ‘Z’ section F7D of size 33 x 25 x 3mm at 1.419 Kg/m and mullion ‘J’ Section (F4B) of size 46 x 25 x 3mm at 2.28 Kg/m and shutter section of made of F7D of 33 x 25 x 3 mm at 1.419 Kg/m as specified in IS 7452 / 1990.Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18 x 5mm MS Flat at 0.70 Kg/m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS Flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in positional firmly.2 numbers of sturdy hinges and one number of handle-cum-latch of special type made with 18 x 5mm MS Flats are revetted to the shutters at an appropriate height in window. Suitable opening is left for its easy operation. A stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle.

-

-

-

... More
Each window shutter having an adjustable stay made out of 18 x 5mm at 0.70 Kg/m MS Flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the outer frame of the window by using MS Flat of 18 x 5 mm at 0.70 Kg/m, welded to the shutter at two place equivalent from each other from top and bottom of the shutter.An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge to edge between them.

-

-

-

... More
All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS 7452 / 1990. The cost includes cost of all materials, labour charges and other incidental charges, etc., complete.

-

-

-

... More
Three Leaves

107.8

-

-

... More
Fabricating, supplying and fixing of steel Emergency exitdoor cum, emergency window with the following specification. M.S. angle in size 40x40x6mm are used for the outer frames and M.S. angle of sie 35x35x5mm for the shutter frame, stiffners with 32x6mm M.S. flats provided at required intervals in the shutter frames 18 guage CR sheet is laid as panel and welded instant for 1/3 bottom portion of the shutter, M.S. flat 18x5mm is welded over the 32x6mm M.S flat sandwitching the CR sheet in between additional stiffner with 18x5mm M.S. flat is provided diagonally at the rear-side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 15kg/m2 and the top portion of operation emergency window is to be made of 25x25x3mm M.S. angle welded intact with CR sheet and 25x3mm M.S. flat at diagonally at the near side of the window at required interwals 6 Nos. of hinges to be provided,6 Nos of holdfast 100mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 2 Nos. one at top and the other at the bottom are to be provided one aldrop is provided at an appropriate place in the door 2 Nos. of 'D' type handle for

50.5

-

-

... More
emergency window and 2 Nos of handle for door is to be provided at appropriate places. A tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation of fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of materials, labour transportation to side of works, loading, unloading and all other incidental charges etc., complete. Double Leaves

-

-

-

... More
Supplying and fixing mild steel iron grill for openings etc., including one coat of red oxide primer using M.S angle of size 40 x 40 x 6 mm and grill using 20 x 6mm M.S flat and necessary hold fast with M.S angle of size 40 x 40 x 6 mm - 230 mm long spliced at end is to be provided at appropriate places for fixing the grill etc., complete complying with standard specification. The type design for the grills should be got approved by the departmental officers before execution.

4200

-

-

... More
Manufacturing, supplying and fixing of steel entrance doors with fixed Portion at sides of Size 4.20 mx 2.9 m (1.80 X 2.10 m - Door & 2.40X2.10 m - Fixed at side, 0.80 x 4.20 m M.S grill at top) With the following specification M.S angles of a size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32x6mm M.S. flat is provided at required intervals in the shutter frames 18 gauge C.R. sheet is laid as panel and welded intact for 1/3 bottom portion of the shutter and side fixed Portion. M.S. flat 18x5mm is welded over the 32x6mm M.S. flat sand witching the CR sheet in between additional stiffener with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. The balance 2/3 portion at top 0.8m is provided with grill at an average weight of 20kg/m2 for Shutter

36.6

-

-

... More
fixed Portion 3nos. of hinges in case of single leaf and 6 Nos in case of double leaves shutter to be provided 6nos of holdfasts 120mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 2nos. one at top and the other at the bottom are provided one aldrop is provided at on appropriate place in the door.One aldrop is provided in the inner lock rail section in the door. and one more aldrop is provided in the inner rail section of the door one rotating locking arrangements locking arrangements for inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place in case of a double leaf door. M.S Flat 32x3mm at1.1 Kg/m is provided on one Shutter to conceal gap between the two Shutters. A Tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation of fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of materials, labour transportation to side of works, loading, unloading and all other incidental charges etc., complete - Double leaves

-

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

3741

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

2708

-

-

... More
Painting new iron works such as grills etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

678

-

-

... More
Providing Blackboard in two layers with first layer in cement mortar 1:5 (one cement and five crushed stone sand (M Sand) )20mm thick and the second layer in Combination mortar 1:1:6(one cement one lime and six crushed stone sand) 20mm thick and 50mm width including cost of one coat of black oxide paint of approved quality etc., complete complying with standard specification and as directed by departmental officers.

86

-

-

... More
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers.

6

-

-

... More
Providing Anti-termite treatment to soil adjacent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers.

766

-

-

... More
Stage 1: Spraying Anti termite treatment chemical solution for the foundation before laying the foundation concrete at bottom and sides of the foundation.

-

-

-

... More
Stage 2: Spraying Anti termite treatment chemical solution to the grade beam level, spraying has to be done for the grade beam, brick masonry in the super structure in contact with back fill earth.

-

-

-

... More
Stage 3: Spraying Anti termite treatment chemical solution on sand for the flooring before laying the flooring concrete; the treatment has to be carried out on the sand filling in basement and after leveling operation is over.

-

-

-

... More
Stage 4: Spraying Anti termite treatment chemical solution around the building on outside by making crow bar holes at an interval of 15 cms to a depth of 30 cms before laying the plinth projection. These holes have to be closed after the treatment.

-

-

-

... More
Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) 25mm thick

209

-

-

... More
Supplying and Fixing of Aluminium Dye Cast Letters of approved size and colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes

-

-

-

... More
Aluminium Dye Cast letters 9" size

58

-

-

... More
Aluminium Dye Cast letters 6" size

69

-

-

... More
Supplying and Installation of Ceramic steel chalk writing board with the following specification. GI sheet of 2mm thickness is fixed with the wall side over the GI sheet necessary special adhesive is spreaded and 9mm MDF Board is fixed on this GI sheet 0.40mm thick ceramic chalk board is provided over the MDF board and the whole arrangements are fixed to the frame using heavy anodised aluminium section and chrominium plated provided in the corners. The whole arrrangements are fixed to the wall using wooden Plugs, screws, etc. complete complying with standard specification

80

-

-

... More
Providing Cup-board Shutter with frame using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer before use on work.

52

-

-

... More
Supplying and fixing 50mm dia GI pipe for Purlins including labour charges for cutting, welding and fixing with Galvalume colour sheet roofing etc., as directed by the departmental officers

72

-

-

... More
Supplying and fixing Galvalume colour sheet roofing with 0.47mm thick of approved quality by drilling holes (and not by punching) with necessary ‘J’ / ‘U’ bolts and nuts etc., complete complying with standard specification and as directed by the departmetal officers

105

-

-

... More
Cement Concrete 1:3:6 (One Cement, Three sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three Sand and Six hard broken stone jelly). Dummy columns should be at least 1 metre height) In First Floor

6.7

-

-

... More
Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedestal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications

8.8

-

-

... More
Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed by the departmental officers

18.6

-

-

... More
Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed

18.6

-

-

... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation,sand filling and refilling charges etc. will be measured and paid separately in the cases where the pipe lines are proposed to laid Below Ground Level a) 110mm dia PVC pipe

6

-

-

... More
Supplying and filling 20 mm ISS metal in dispersion trench including stacking for pre measurements around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc.,complete.

3

-

-

... More
Supplying and filling 40mm ISS metal in dispersion trench including stacking for pre measurements around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc.,complete.

2

-

-

... More
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).

-

-

-

... More
110mm dia pvc elbow

4

-

-

... More
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crused stone sand (M Sand) and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. a)50mm thick using 20mm HGB Jelly

5

-

-

... More
Supplying and fixing of RCC well ring of size 1.20x0.075x0.30m in RCC 1:2:4 (one cement, two crushed stone sand (M Sand) and four hard broken granite stone jelly) using 20mm HBGS jelly including cost of reinforecement steel in position but. including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification.

24

-

-

... More
GST 18 %

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.