Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Jan 2025
Closing Date29 Jan 2025
Tender Amount₹ 8,75,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.

213

-

-

... More
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification

90

-

-

... More
Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

117

-

-

... More
Supplying and filling GRAVEL in 'foundation and basement with filling crushed stone sand in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification.

214.5

-

-

... More
Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification

160

-

-

... More
Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers

69

-

-

... More
Brickwork using Fly Ash bricks of size 230mmx110mmx70mm virtually the bricks shall be sound compact and uniform in shape free from visible cracks warpage flaws and organic matter. The bricks shall be solid with frog on one of its bearing side. Class designation not less than 35 kg/sq. cm an average compressive strength in Cement Mortar 1:3 - One Cement and three crushed stone sand - including neat finishing, curing etc., complete complying with standard specifications.-For foundation and basement

36

-

-

... More
Brickwork using Fly Ash bricks of size 230mmx110mmx70mm virtually the bricks shall be sound compact and uniform in shape free from visible cracks warpage flaws and organic matter. The bricks shall be solid with frog on one of its bearing side. Class designation not less than 35 kg/sq. cm an average compressive strength in Cement Mortar 1:5 - One Cement and five crushed stone sand - including neat finishing, curing etc., complete complying with standard specifications.

-

-

-

... More
For foundation & basement

88

-

-

... More
Super structure in Ground Floor

6

-

-

... More
Brickwork using Fly Ash bricks of size 230mmx110mmx70mm virtually the bricks shall be sound compact and uniform in shape free from visible cracks warpage flaws and organic matter. The bricks shall be solid with frog on one of its bearing side. Class designation not less than 35 kg/sq. cm an average compressive strength in Cement Mortar 1:6 - One Cement and six crushed stone sand - including neat finishing, curing etc., complete complying with standard specifications.-For foundation and basement

-

-

-

... More
Super structure in Ground Floor

35.5

-

-

... More
Super structure in First Floor

108

-

-

... More
Super structure in Second Floor

110

-

-

... More
Super structure in Third Floor

110

-

-

... More
Super structure in Fourth Floor

120

-

-

... More
Super structure in Fifth Floor

27

-

-

... More
Super structure in Sixth Floor

15

-

-

... More
Brick partition walls of 11.50cm thickness using best quality Fly ash bricks of size 23x11x7cm in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)

-

-

-

... More
In Ground floor

12

-

-

... More
In First floor

61

-

-

... More
In Second floor

55

-

-

... More
In Third floor

51

-

-

... More
In Fourth floor

54.5

-

-

... More
Damp proof course with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used, finishing and curing etc. complete complying with standard specification.

86

-

-

... More
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)

475

-

-

... More
Supplying and Erecting, Steel Centering for sides and soffits including supports and strutting upto 3.29m height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90cmX60cm and BG 10 gauge stiffened with welded mild steel angles of size 25mmX25mmX3mm for boarding laid over silver oak joists of size 10cmX6.50cm spaced at about 90cm centre to centre and supported by Casurina props of 10cm to 13cm dia spaced at not less than 75cm centre to centre at sutiable intervals etc., complete in all floors as directed by the departmental officers complying with standard specifications. The payment for centering shall be made only after the concrete laid. The retrieved materials should be taken back by the contractor.-

-

-

-

... More
Plane surfaces such as RCC floor slab, roof slab, rectangular, square, Tee or Ell beam, lintels, bed blocks staircase waist slab, landing slab, landing beams, portico beams, portico slab etc.,

4375

-

-

... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.

1681

-

-

... More
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.

374

-

-

... More
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.

2100

-

-

... More
Providing and laying in position, standardised concrete Mix M.20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/ms and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
Foundation and Basement

365

-

-

... More
Super structure in Ground Floor

141

-

-

... More
Super structure in First Floor

125

-

-

... More
Super structure in Second Floor

127

-

-

... More
Super structure in Third Floor

125

-

-

... More
Super structure in Fourth Floor

127

-

-

... More
Super structure in Fifth Floor

75

-

-

... More
Super structure in Sixth Floor

9

-

-

... More
Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three crushed stone sandand Six hard broken stone jelly). Dummy columns should be at least 1 metre height)-in Third Floor

6

-

-

... More
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed.

-

-

-

... More
50mm thick slab (using 20mm HBGS Jelly)

6

-

-

... More
75mm thick slab (using 20mm HBGS Jelly)

11

-

-

... More
Supplying, fabricating and placing in position Mild steel or Ribbed tor steel in all size for all RCC works as per the design given including cost of steel and binding wire in all floors etc., complete complying with standard specifications. (The contratctor will have to make his own arrangements for the supply of MS plain rod / RTS rod and binding wire)

1625

-

-

... More
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. For Foundation and Basement

0.5

-

-

... More
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.

-

-

-

... More
In First Floor

10

-

-

... More
In Second Floor

10

-

-

... More
In Third Floor

10

-

-

... More
In Fourth Floor

52

-

-

... More
In Fifth Floor

7

-

-

... More
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 16 to 18mm approved quality set in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers

522

-

-

... More
Paving the floor with best quality Double charged Vertified Tiles of size 800x800x10mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

1390

-

-

... More
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.

291

-

-

... More
Providing full nosing to the steps or platforms to the Granite slab of 20mm thick including neat finishing, polishing, cost of powder, tools etc as directed by the departmental officers

255

-

-

... More
Paving the floor with best approved quality fine polished Kota stone slabs of size below 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.

73

-

-

... More
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and printing with white cement mixed with colouring pigments at the rate of 0.3kg/m2,etc.,complete.complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

143.5

-

-

... More
Dadooing walls with 300x600x10mm best approved quality, printed design / colour glazed tiles set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. /sq.mneatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.

441

-

-

... More
Dadooing with granite tiles of Jet black of suitable sizes with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.

302

-

-

... More
Paving the floor with Cement Based Hydraulically Pressed concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

540

-

-

... More
Providing Polymer Coating (Water Proof Coating) for sunken Portion of toilet with following specification and the surface shall be cleaned to remove all dust, foreign, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred throughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.

193

-

-

... More
Supplying and fixing in position best approved of BIS quality 160mm dia PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.

-

-

-

... More
Five Floors

243

-

-

... More
Six Floors

15

-

-

... More
Supplying wrought fixing Ornamental Teakwood entrance door as per the drawing and designs approved by the departmental officers. The size of the opening is 2.10X 2.40. The outer frame of the door is 150mmx125mm teakwood. The main door shutter opening size is 1.80 X 2.03m. The main door should be double leaves and each door shutter fully panelled. The door panells shall be of 50mm thick teakwood planks with ornamental designs approved by the Executive Engineer. The Lock rail and bottom shall be of 200 x 50mm tk teakwood, top rail 230x50mm tk teakwood. The door frames and shutters shall be given of cost of best approved quality melamine finish. The rate inclusive of cost of approved quality teakwood, 10mm thick designed toughedned glass Special type Heavy Brass Aldrop 300mm X 20mm. Special type heavy Brass tower bolt 300mm Length. Special type heavy Brass tower bolt 250mm Length. The cost includes cost of material, labour charges, conveyance charges, fixing charges, designing charges and glass design charges, electricity charges and all other incidental charges., etc. All materials should be got approved by the Executive Engineer before use on works.

7.5

-

-

... More
Supplying ,fabricating and fixing in position of steel frame without bottom frame, of size 100X60mm rectangular section with necessary rebate 30mmX15mm, to host the shutter,using 1.25mm thick (18 guage) CRCA cold rolled frame steel plate confirming to ISI specified ensured of right butt joint riveted hold assembly with nylon insert,not be welded with special purpose hard ware.Proclaimed including phopating as per ISI with rust preventive primer ready to assemble condition for easy installation at site including dismantling,making necessary chipping and holes in RCC columns, walls with power drills to the extent required ,including providing concrete 1:2:4 inside the box curing etc complete.The cost includes the cost of hold fast ,plastic bush, insert receiver,rubber bottom,shock absorber etc complete as directed by the departmental officers in all floors.

180

-

-

... More
Supplying and fixing solid core particle board flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround commercial ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm tower bolt 2nos. 150x12mm tower bolts 1no. 250x16mm aldrops, 3 nos. 200mm ‘D’ type door handle and door stopper with bush etc., complete as directed by the departmental officers.

-

-

-

... More
Single leaf

55

-

-

... More
Double Leaf

14.7

-

-

... More
Supply & fixing of WPC (Wood Polymer Composite) Frame extruded with size 75mm x 50mm. The single core door made of rigid WPCcompound with minirmum Bulk Density of 900 KG/ Cub M1, & shore hardness of 55. Supply & fixing ofWPs door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+t Imm) & minimum Bulk Density of 550 KGI Cub Mt & shore hardness of 55. For the aesthetic appearance, the door shall be a pinted digitally on one side of the shutter and the design is as decided by the Engineer in-Charge of the department. The WPC door shall be fixed in to the WPC frame with 3 Nos of 5 SS Hinges and the door shall have 2 towerbolt on one side and 1 towerbolt or aldrop on other side for locking system and 2 numbers of |handle on the either side of the door shutter, all made of aluminium.

49

-

-

... More
Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KGI Cub. Mt & shore hardness of 55. The door shall be a plain matt board as decided by the Engineer in-harge of the department.The WPC door shall be fixed onto the luminium "G type channel with Wheel and the door shall have 2 Hooks in Ss, 2 andles 4' in SS.(Sliding door)

12.6

-

-

... More
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work

204.5

-

-

... More
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work

55.5

-

-

... More
Manufacturing supplying and fixing of steel door (Single leaf) with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete.

6.3

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete

124

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Handrails for staircase near wet riser using 50mm dia 304L GradeStainless Steel pipe of 1.60mm thick will be provided withtubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60m thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete

115

-

-

... More
Supplying, and fixing M.S. GRILLS for open courtyard grill, grill work to doors, windows and ventilators etc, using necessary flats for inner and outer members which should be fixed or welded to masonry or column including necessary dismantling or making holes and redoing the same to original condition as directed by the departmenta officers inclusive of cost of providing one coat of best quality red oxide primer completre complying with standard specifications.

7690

-

-

... More
Providing suspended Hilux Board False Ceiling of the following types with G.I. perimeter channel of size 0.55mm tk (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling , screw fixed to brick wall/ partition with the help of nylon sleeves and screws at 610mm centres. Then suspending G.I. Intermediate channel of size 45mm (0.90mm thick with two flanges of 15mm each) from the soffit at 1200mm centres with ceiling angle of 25mmx 10mmx0.50mm thick fixed to soffit with G.I Cleat and steel expansion fastners ceiling section of 0.50mm thickness having knurled web of 51.50mm and two flanges of 26mm each with lips of10.50mm are then fixed to the intermediate channel at 457mm centres. 12.50mm tapered edge Gyp board (confirming to is 2095-1982) is then screw fixed to ceiling section with25mm dry wall screws at 230mm centres. Screw fixing should bedone mechanically either with screw driver or with drilling machine with suitable attachment got approved by the Executive Engineer before use on works in etc., complete complying with standard specification.-Using Hilux board plain sheets (10mm thick)

205

-

-

... More
Providing Cornice Work for Gyp Board False Ceiling etc., complete in all floors complying with standard specification and as directed by the departmental officers.

148

-

-

... More
Supplying and fixing fine polished cuddapah slab of 38/40mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.25mm thick

91

-

-

... More
Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.

106

-

-

... More
Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both directions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevicol and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete.

114

-

-

... More
Plastering with Cement Mortar 1:5 (One cement and Five P.sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.

5060

-

-

... More
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P.Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers

3045

-

-

... More
Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three P.sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.

565

-

-

... More
Plastering with Cement Mortar 1:4 (One Cement and Four Sand) 20mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard s conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.

119

-

-

... More
Providing Wall Putty including labour charges etc., complete in all floors complying with standard specification and as directed by the departmental officers.

6515

-

-

... More
Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then bel sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc., complete]. The putty should be got approved by the Executive Engineer before use on work.

2625

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

3542

-

-

... More
Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., complete complying with standard specification.

2594

-

-

... More
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

235.5

-

-

... More
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

167.1

-

-

... More
Supplying, laying and jointing 25mm dia CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works.(Internal Water Supply)

285

-

-

... More
Supplying CPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements standard specification

-

-

-

... More
25 mm dia CPVC Elbow

90

-

-

... More
25 mm dia CPVC TEE

110

-

-

... More
25 mm dia CPVC Union

80

-

-

... More
25 mm dia UPVC Nipple

60

-

-

... More
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.-Internal Water Supply Arrangements - Above Ground Level

-

-

-

... More
25mm dia UPVC pipe

300

-

-

... More
32mm dia UPVC pipe

150

-

-

... More
40mm dia UPVC pipe

200

-

-

... More
50mm dia UPVC pipe

60

-

-

... More
Supplying, laying and jointing 40mm dia -UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. -External Water Supply Arrangements - Below Ground Level

70

-

-

... More
Supplying UPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements

-

-

-

... More
25 mm dia UPVC union

110

-

-

... More
32 mm dia UPVC union

55

-

-

... More
40 mm dia UPVC union

60

-

-

... More
50 mm dia UPVC union

70

-

-

... More
25 mm dia UPVC Elbow

110

-

-

... More
32 mm dia UPVC Elbow

40

-

-

... More
40 mm dia UPVC Elbow

40

-

-

... More
50 mm dia UPVC Elbow

30

-

-

... More
25 mm dia UPVC Tee

110

-

-

... More
32 mm dia UPVC Tee

50

-

-

... More
40 mm dia UPVC Tee

45

-

-

... More
50 mm dia UPVC Tee

20

-

-

... More
32 x 25 mm dia UPVC Reducer

60

-

-

... More
25 x 20 mm dia UPVC Reducer

60

-

-

... More
20 x 15 mm dia UPVC Reducer

75

-

-

... More
Supplying and fixing in position first quality and approved variety of following dia Gun metal Gate Valve with BIS make including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.

-

-

-

... More
25 mm dia G.M. Gate Valve

10

-

-

... More
32 mm dia G.M. Gate Valve

10

-

-

... More
40 mm dia G.M. Gate Valve

10

-

-

... More
50 mm dia G.M. Gate Valve

10

-

-

... More
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm colour glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).

5

-

-

... More
Supplying and fixing in position Colour glazed European Water Closet 10 litre capacity PVC flushing tank fixed on to wall of best quality and approved make with 100 mm "P" or "S" trap connecting with PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.

17

-

-

... More
Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)

8

-

-

... More
Supplying and fixing in position best quality and approved make Indian made colour glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers.

26

-

-

... More
Supplying and fixing in position best quality Granite sink of following sizes including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Executive Engineer before use on works]

4

-

-

... More
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 500 x 400 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification

26

-

-

... More
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.

26

-

-

... More
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications.

26

-

-

... More
Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers

8

-

-

... More
Supplying and fixing in position 15mm dia brass CP screw down tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary

28

-

-

... More
Supplying, laying and jointing glazed stoneware pipes of 100mm dia of approved best quality with spigot and socket ends (in reverse direction) in dry condition and laid in loose joints (i.e.) without cement and spun yarn, so that the waste water can be drained to the trenches already available, excluding cost of earth work excavation, cost of re-filling with sand / earth, but including laying the pipe in true alignment and gradient and conducting required water supply test for draining with necessary tools and plants, etc., complete complying with standard specifications.

30

-

-

... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level

-

-

-

... More
75mm dia PVC soil

210

-

-

... More
110mm dia PVC soil

160

-

-

... More
160mm dia PVC soil

40

-

-

... More
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).

-

-

-

... More
75mm dia PVC Elbow

37

-

-

... More
75mm dia PVC Tee

37

-

-

... More
75mm dia PVC Tee with single door

37

-

-

... More
75mm dia PVC Bend

37

-

-

... More
110mm dia PVC Elbow

24

-

-

... More
110mm dia PVC Tee

24

-

-

... More
110mm dia PVC Tee with single door

24

-

-

... More
110mm dia PVC Bend

24

-

-

... More
Supplying and fixing position PVC Nahani Trap / Floor Trap of the 100 x 75mm with stainless steel gratings sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the PVC pipes, etc., complete complying with standard specification.

210

-

-

... More
Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers

2

-

-

... More
Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications

6

-

-

... More
Supplying and filling 20mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers etc.

15

-

-

... More
Supplying and filling 40mm guauge HBGS stone jelly for dispersion trench including loading conveying and unloading and as directed by the departmental officers etc.

15

-

-

... More
Drilling of Borewell in sedimentary strata of hard rock stone shale pebbles bolders etc., By first taking a pilot bore of 150mm dia and then enlarging to the required dia by direct or reverse rotary mud circulation method using rotary rigs, fuel labour and drilling bentonite and water required for dirlling at site.

-

-

-

... More
upto 150m below GL

150

-

-

... More
From 151 to 180m

30

-

-

... More
From 181 to 210m

20

-

-

... More
Supplying of best approved quality of PVC casing pipe of 6" dia (Special Blue Pipes for Bore Well) for borewell with socket end to suit borewell of required depth -6kg/cm2 best approved quality with ISI mark with necessary PVC coupling etc.,

12

-

-

... More
Supplying and fixing of suitable PVC endcap (6kg/cm2) for 6" dia borewell of best quality with ISI mark

1

-

-

... More
Supply and delivery Of 3Core copper conductor Flat Cable (4Sq.mm) confirming to IS 694/1990 with ISI marking sutiable for Submersible Pumpset etc., Complete

220

-

-

... More
UPVC Pipe (Un-Plasticized Polyvinyl Chloride) used for commercial applications operate and designed to handle higher water pressure 40mm dia UPVC pipe (Column pipes) for Bore well

220

-

-

... More
Supplying of best and approved quality of Nylon rope of the following size including laying in the bore well and tying with copper wire it etc commplete complying with standard specification.

220

-

-

... More
Supplying and fixing erecting 5 HP ISI make bore well SUBMERSIBLE PUMPSET with required accassories for the 5HP ISI make3 phase electricmotar 2900rpm , 400/S.S. shaft cable of discharging 100 to 200 LPM against a total Head of 135m to 100m with ISI mark and an outlet of 50mm and suitable for 150mm dia bore well including supplying and fixing M.S. fabricated wall mounting Pannel board with internal wiring as per I.E. rules and necessary locking arrangements with suitable cutler and hammer type bush button automatic 10 HP texvel DOL starter - 1 no, suitable 15 Amp, TPIC switch, 0 to 500 v Voltmeter, 0 to 20 Amps Ammeeter, single phase preventer. pilot lamps with 3 bulps to indicate power supply and 50mm dia GI couplying - 2 nos, M. S. clamps - 2 nos, 2.5 Sq mm wire 3 core copper flat submergible cable, including Conveyance and Erection charges including required G. I. pecials, MR Tape Electrical connection charges., delivery pipe connection charges and other plumbing works including hire charges for Chain pully, tripod and other tools and trial run for three days etc., including labour charges complete complying as directed by the departmental officers.

1

-

-

... More
Supplying and fixing 3 Phase wall mounting of Panel board with following accessories a.Suitable DOL type push botton automatic starter etc., complete.

1

-

-

... More
Supplying and erecting 2.0 H.P monoblock with ISI mark with necessary accessories (motor should be got approved by Executive Engineer before use onworks) complete complying with standard specification.

1

-

-

... More
Supplying and fixing 1000 Litres PVC ready made WATER TANK best and approved quality with ISI specification and having inlet,outlet, overflow and clearing pipe arrangements and labour charges for fixing in position with all necessary accessories and transporting at site of work etc., complete complying as directed by the departmental officers

2

-

-

... More
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers.

494

-

-

... More
Supplying and erecting in position of 250 liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No. Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact

2

-

-

... More
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental fficers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT

8

-

-

... More
Supply and fixing of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers.

8

-

-

... More
Supply and fixing Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS:15683., complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., ncluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST ? EQUIVALENT.

8

-

-

... More
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, ncluding conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / QUIVALENT.

8

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) (SD-281)

322

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End (SD-283)

49

-

-

... More
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End (SD-298)

5

-

-

... More
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections. Higher End (SD-375)

18

-

-

... More
Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (SD-389)

78

-

-

... More
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (SD-401)

50

-

-

... More
Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug inflush with wall with earth connection (For AC Plug) (SD-144)

26

-

-

... More
Supply and fixing of 9W LED for BH point. (DATA-1)

17

-

-

... More
Supply and fixing of 4 feet 20W LED SBT fitting with 20 W LED tube (Higher end) complete with TW round blocks on wall or ceiling with PVC unsheathed Copper leads from the terminals to the fitting. (DATA-2)

119

-

-

... More
Supply and fixing of 4 feet 20W LED SBT fitting with 20 W LED tube (Higher End) complete with conduit pipe suspension from the ceiling with PVC unsheathed Copper leads from the terminals to the fitting. (DATA-3)

12

-

-

... More
Supply and fixing of 4'20W Twin box type LED fitting complete with conduit pipe suspension from the ceiling with 2 Nos 20 W LED TubeLight (Double Side) with PVC unsheathed FRLS copper leads from terminals to the fitting. (DATA-4)

30

-

-

... More
Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. (SD 489)

91

-

-

... More
Supply and fixing of WT bulk head fitting with guard suitable for 15 W LED Bulb. (SD-83)

14

-

-

... More
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting. (SD-448)

6

-

-

... More
Supply and fixing of AC/DC 76mm buzzer /call bell suitable for 230volts 50c/s single phase AC supply on suitable TW board with push switch. (SD-105)

22

-

-

... More
Supply and fixing of 1200mm (48") Sweep BLDC ceiling fan complete (HIGHER END) with 2 Module 100 W Fan Step Regulator (HIGHER END) with stepped with 300mm down rod on the existing fan clamp (DATA-5)

85

-

-

... More
Supply and fixing of 16" (400 mm) Wall mounting fan on wall with necessary connection complete. (DATA-6)

2

-

-

... More
Supply and fixing of 300mm (12") sweep (lightduty) AC exhaust fan complete with necessary wall opening and making good of the wall. (SD-114)

11

-

-

... More
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan. (SD-120)

11

-

-

... More
Supply and fixing of 375mm (15") sweep (lightduty) AC exhaust fan complete with necessary wall opening and making good of the wall. (SD 116)

5

-

-

... More
Supply and fixing of louvers shutters arrangements for 375mm (15") sweep light duty AC Exhaust fan (SD 121)

5

-

-

... More
Supply and fixing of 32A DP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection only. (DATA-7)

3

-

-

... More
Supply and fixing of 32 A FP MCB in 4 pole sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection only.. (Higher end). (DATA-8)

3

-

-

... More
Supply and fixing of 63 A FP MCB with 63 A FP ELCB 30mA with 4 pole sheet steel enclosure on wall and earth connection (Higher End) (DATA-9)

2

-

-

... More
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End (SD-514)

10

-

-

... More
Supply and fixing of 4 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board (with MCCB Incomer) with double door (metal door) with 1 no. 125 A 4 P MCCB switch as incoming and 4 nos. 63A 3P MCB as outgoing with suitable cable end box on wall with earth connection only. Higher End (DATA-10) (for entire lighting & power distribution)

3

-

-

... More
Supply and fixing of 8 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board (with MCCB Incomer) with double door (metal door) with 1 no. 125 A 4 P MCCB switch as incoming and 7 nos. 63A 3P MCB , 3 nos. 32A 3P MCB as outgoing with suitable cable end box on wall with earth connection only. Higher End (DATA-11) (for entire lighting & power distribution)

2

-

-

... More
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End (SD-526)

9

-

-

... More
Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following on wall with earth connection only. (SD-621) (for power & lighting distribution) i) 63A 4P MCB - 1 no. ii) 63A 4P 30MA RCCB/ELCB - 1 no. iii) 63A DP MCB IsOLATOR -3 nos. iv) 6A to 32A SP MCB - 12 nos ( SD 627)

12

-

-

... More
Supply and erection of 400 Amps Capacity dust and vermin proof floor mounting cubical panel board fabricated out of 16 SWG CRCA sheet for outer body,stiffness and doors and with supply and fixing of following interior switches with centre bus bar chamber and horizontal no of switches side to side on both sides of bus bar chamber with cable chamber of the extreme right end and top of Panel with two coats of quality paint over one coat of zinc oxide primer superscription of incoming and outgoing feeding cable details, capacity of switches etc., with white paint and 2nos metallic danger board affixed complete on 3"x1½"x¼" base channel supports on 6Nos of 0.45m channel legs to satisfy the latest CEIG rules with the following switches conforming to IS specifications.

1

-

-

... More
1) 400A FP Switch Disconnector Fuse Units interior only with HRC Fuses Double Break - 1 No as Incoming.

-

-

-

... More
2) 125A TPN Switch Disconnector Fuse Units interior only with HRC Fuses Double Break - 6 Nos as Out going.

-

-

-

... More
3) 63A TPN Switch Disconnector Fuse Units interior only with HRC Fuses Double Break - 5 as Out going.

-

-

-

... More
A separate chamber on the top of one side should be fixed with multi function meter, C.T, Selector switches with 1No. LED pilot lamp set.

-

-

-

... More
The bus bar chamber should have 3Nos of 2" x 1/4" tinned copper flat for 3phases and 1No of 1" x 1/4" tinned copper flat for Neutral and body earth bus must be run all round the panel using 2runs of 1" x 1/8" tinned copper flat to provide earth connection to the cubicle switches cable glands etc., the bus bars should be supported on synthetic enamel compound at equal interval as per IS specification. The incoming and outgoing switches should be connected to the bus with the following copper flats.

-

-

-

... More
1) 400A FP switch with 2" x 1/4" tinned copper flat.

-

-

-

... More
2) 125A TPN s switch with 1.2" x 1/4" tinned copper flat.

-

-

-

... More
3) 63A TPN Switch with No.8 SWG Copper Conductor.

-

-

-

... More
The switches should be separated from the bus bars by 6mm thick hylum sheet and all switches should be properly earthed by solid copper flat as per IE rules and CEIG specification. Providing Rubber Beading for All Doors.

-

-

-

... More
The Panel should be mounted on angle iron frame work of size 1½"x1½"x¼" MS channel provided all around the sides of the panel. The whole arrangements should be erected on 3"x1½"x¼" MS Base channel on a suitable masonary pedastal. (All Switches should be with ISI mark and of Higher End make only) (DATA-12)

-

-

-

... More
Supply, erection, testing and commissioning of 1.5TR (4500K cal / hr) ABS plastic split type Air conditioner confirming to IS 1391 [part 2] 1992 with Rotary compressor operating on refrigerant R-22/Non CFL suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply with Three Star rating as per BEE Specific and capable of performing the following functions.

10

-

-

... More
The installation work for the above split type AC units includes the following. (A) Cooling (B) Dehumidifying (C) Air Circulating. (D) Filtering. 1. Mounting / fixing indoor and outdoor units at their respective locations. 2. Laying refrigerent pipe line of 6mtrs. Distance and connecting the both units after drilling hole / holes in the wall if required. Thickness of the copper tubing shall not be less than 0.80mm. 3. Installing the suction pipe with expanded polythene foam 5mm thick tubing. 4. Laying 15mm dia flexible PVC drain pipe of 6mts. Length to throw out the condensate water being formed in the indoor unit. 5. Leakage testing the entire gas unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units up to 4mtr. length and up to switch within the 3 mtrs. of location of indoor unit. (SOR-M-1984)

-

-

-

... More
Supply and Erection of 4 KVA Voltage stabilzer for 1.5 TR split type AC unit high / low voltage cut off time delay relay with input voltage cut off time range of 170V - 270V and out put range of 200 - 240V with 3 minutes time delay relay (SOR-M-1988)

10

-

-

... More
Supply, Erection, testing and Commissioning of 2.0TR (6000K cal / hr) ABS plastic split type Air conditioner confirming to IS 1391 [part 2] 1992 with Rotary compressor operating on refrigerant R-32/Non CFL suitable for wall mounting for operation on 230V, 50 HZ single phase AC Renewal by supply with Three Star rating as per BEE Specification and capable of performing the following functions. (A) Cooling (B) Dehumidifying (C) Air Circulating. (D)Filtering. The installation work for the above split type AC units includes the following. 1. Mounting / fixing indoor and outdoor units at their respective locations. 2. Laying refrigerant pipe line of 6mtrs. distance, both units after drilling hole / holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm. 3. Installing the suction pipe with expanded polythene foam 5mm thick tubing. 4. Laying 15mm dia flexible PVC drain pipe of 6mts. Length to throw out the condensate water being formed in the indoor unit. 5. Leakage testing the entire gas unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units up to 4mtr. length and up to switch within the 3 mtrs. of location of indoor unit. (SOR-M-1985)

1

-

-

... More
Supply and Erection of 5 KVA Voltage stabilzer for 2 TR split type AC unit high / low voltage cut off time delay relay with input voltage cut off time range of 170V - 270V and out put range of 200 - 240V with 3 minutes time delay relay (SOR-M-1989)

1

-

-

... More
Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit) (SR)

90

-

-

... More
Supply and fixing of MS stand for fixing outdoor unit.(SR)

11

-

-

... More
Supply, Installation, Testing and Commissioning of 4.0 TR (9000K.ca;/Hr) capacity 4-way Cassette Type (Invertor) Air Conditioner Unit with Cooling Coil Section and Blower Motor with required valves and Mocroprocessor Control Panel.Outdoor Unit shall consist of Hermetically Sealed Scroll/Rotary compressor with Inbuilt Protection, Auto Reset Type HP/LP Cut outs with Highly Efficient condenser Assembly Suitable for Operation Three Phase, 50Hz. As per BEE Specification. The Units Shall be capable of performing the following functions. Cooling Dehumidifying Air Circulating Filtering The Installation work for the Indoor Unit shall include fitting the unit on the false celling with anchor fasteners and threaded rods, etc., and the outdoor unit on suitable mounting stand and with Anti Vibration mounts. Unit shall be charged with Non-CFC Refrigerant gas and Leak Tested and Commissioned as per the design requirements. (SOR-M-2657)

3

-

-

... More
Supply and fixing of water drain pipe line (1” PVC Pipe) (SR)

45

-

-

... More
Supply and fixing of 3000VA UPS with 6Nos. 12V 150AH tubular battery with 2 hours back up and 48months warranty for mentioned capacity on full load operation and the following features. a) Inverter shall be free from workman ship defects sharp edges nicks, scratches, burs etc, all fasteners shall be fixed properly. The equipments shall be complete with all parts and all parts shall be functional. b) Enclosure shall conform to protection requirement of IRL to IS 13947 (part 1) 1993.

8

-

-

... More
c) Switching device shall be most ET (or) IGBT. d) Switching frequency shall be above 50HZ. II. Input ; 120 v to 260 v 50 HZ single phase AC III. Output : The variation in output voltage from NO- load to full load expressed as a percentages of no load voltage shall ont exceed +1 5% over + 10 % and 20 % variation of the rated DC input voltage. The frequency of the output voltage shall be 50 HZ + 1.3%. IV). Inverter efficiency minimum 85% as per CI.T.93 of ISS. v) Over load: inverter shall with stand 10% overload for at least 10 minutes. V). Protections.

-

-

-

... More
VI). a) Input voltage goes outside the range 120 to 260 volts the system shall switch over to inverter mode. b). over voltage short circuit and over load at inverter output terminals. C).Battery reverses polarity.

-

-

-

... More
d). Protection against over discharge.

-

-

-

... More
The load shall be cut off as soon as the voltage of the battery terminal falls blow. i) 10.5 v for 12 v and ii) 21v for 24v battery system

-

-

-

... More
e).The inverter shall incorporate an arrangements for automatic charge over of load from main supply to the inverter AC output incase of failure of mains supply with

-

-

-

... More
correct pending indication as per cL; 5.6 of IS 13314/ 1992

-

-

-

... More
f). inverter should hane surge protection also VII indicators. a) Following indicators shall be provided.

-

-

-

... More
i) Mains presence ii) Mains mode. iii) Battery charging

-

-

-

... More
iv) INVERTER MODE v) Battery low. 80 battery bank; 12 Volts lead battery to IS 7372 (1995) with amdts.No1,2&3 shall be reputed makes from the following i.e Exide/ Amci/ yuosa pretolite/ kirloskar/ amarraja. ISI marked. 9) Battery stand with wheel angle iron frame arranged. / Steel fabricated stand. (SOR-M-2106)

-

-

-

... More
Design, Engineering, Supply, Fabrication, Erection, Testing, Commissioning, handing over, obtaining erection permission from the CEIG, obtaining lift insurance, obtaining lift licence and obtaining safety certificate and handing over of 1 No. 10 Persons capacity Passenger / Disable friendly lift complete Gearless with machine room with the following specifications.

1

-

-

... More
I. General Number of Lift : 1 No. (a) Capacity and type 10 Persons (680Kgs) Capacity Passenger lift with machine room ( b) Speed : 1.5 Mtr / Sec. (c) Drive : Micro Processor based VVVF energy saver (d) Size of Lift well : 2000x1800 (mm Wide x mm Depth ) (e) No. of floors : 5 (Ground + 4 Upper floors) ( f) Total height of Travel : 19.00 Mts (g) No.of stops : Five ( Ground + 4 floors) (h) No. of opening : Five (Ground + 4floors) (i) Construction of lift well : R.C.C. with brick masonry/ Brick well (j) Power supply : AC 400 / 440 Volts, 3 phase, 50 Cycles. (k) Auxiliary supply : 230V, AC supply ( Single phase ) (l) Position of machinery : Directly above the lift well. (m) Lift pit depth : 1600mm (n) Leveling accuracy : High level accuracy with smooth & jerk free stopping.

-

-

-

... More
II. CAR a. Size of Lift Car inside : 1350 x 1300 ( mm Wide x mm Depth ) b. Design of lift car : SS finish car panel c. Car ceiling : SS false ceiling d. Car floor : granite / marble flooring e. Car fittings : LED ( JLPL77) & 300 mm REGULAR cabin (CIRCULAR) - 1 FAN. And emergency light f. No. of opening : One ( In front only ) g. Car Entrance : Power operated V3F drive side opening S.S, sliding door - with provision for emergency key opening at all landings. h. Clear opening : 900 x 2000 ( mm Wide x mm Height ) III. ENTRANCE a. Car :Power operated V3F drive side opening, SS sliding door - b. Landing Entrance Door : S.S door IV. OPERATION Microprocessor based Simplex, Collective, Selective control with / without attendant. V. Car and Landings :Digital floor position indicator in car and all landing. Dry cell operated alarm bell and emergency light with Automatic charging device, Up /Down Digital direction indications at all landings and in car.

-

-

-

... More
VI. STEEL LADDER FOR LIFT MACHINERY included in the estimate VII. SPECIAL FEATURE : Digital position indicator in Car and landings. Battery operated Emergency light and Alarm bell, call register signal and VF Door operator, false ceiling in Car. Infra red door screen, Vandal proof SS Button with SS cover / Automatic Rescue Device. Fire mans switch. Intercom provisions with Instruments and floor Annunciator. VIII. Automatic Rescue Device ( ARD ) : To facilitate landing of lift to the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger, inverter, under voltage protection system etc. complete with all accessories. IX. MINOR BUILDER WORK : included in the estimate X. SCAFFOLDING WORKS : included in the estimate XI. FREE SERVICE AND MAINTENANCE DURING THE GUARANTEE PERIOD OF ONE YEAR. a. Guarantee : Guarantee for materials and workmanship of equipment not less than one year. b. Free maintenance: Free comprehensive, servicing and maintenance during the guarantee period to be provided by the Lift contractor. And important necessary training of employees, for minor maintenance works and proper handing over of lift to be done by the lift contractor.

-

-

-

... More
c. Preparation of Drawings and obtaining CEIG's Safety Certificate for lift approval as per lift act with payment of necessary fees to CEIG and insurance policies. If any d. Site tests in accordance with IS 14665 shall be carried out at time of handing over. Architrave covering all the 3 sides of the entrance door with 3mm thick declaim sheet with cardboard upto a height of 1.5 mts from the sill level. Supply of operation and maintenance manual with necessary toos for operation. The list of tools required should be detailed by the contractor in a separate should duly signed by the contractor. VI. OTHER INCLUSIONS : Over speed Governor, phase failure and phase reversal relay, alarm bell, T. Guide brackets for car and counter weights, rubber padding under winding unit, Motor of adequate 7.5 HP capacity, electro magnetic brake with compression springs, car safety gear, buffer, electro mechanical door locks, tubular S.S hand rail in car. Steel ladder for machine room, Emergency key, motor over load protection devices, final limit switch, position and direction indicators for car and landing entrances, main suspension ropes, counter weights, lifting joists for mounting the machines S.S. facial plate for car operating panel & landing fixtures, fireman's switch and other necessary controls - complete set.

-

-

-

... More
Design, Engineering, Supply, Fabrication, Erection, Testing, Commissioning, handing over, obtaining erection permission from the CEIG, obtaining lift insurance, obtaining lift licence and obtaining safety certificate and handing over of 1 No. 13 Persons capacity Passenger / Disable friendly lift complete Gearless with machine room with the following specifications.(M-2365) I. General Number of Lift : 1 No. (a) Capacity and type 13 Persons (884Kgs) Capacity Passenger lift with machine room ( b) Speed : 1.5 Mtr / Sec. (c) Drive : Micro Processor based VVVF energy saver (d) Size of Lift well : 2450x1800 (mm Wide x mm Depth ) (e) No. of floors : 5 (Ground + 4 Upper floors) ( f) Total height of Travel : 19.00 Mts (g) No.of stops : Five ( Ground + 4 floors) (h) No. of opening : Five (Ground + 4floors) (i) Construction of lift well : R.C.C. with brick masonry/ Brick well (j) Power supply : AC 400 / 440 Volts, 3 phase, 50 Cycles. (k) Auxiliary supply : 230V, AC supply ( Single phase ) (l) Position of machinery : Directly above the lift well. (m) Lift pit depth : 1600mm (n) Leveling accuracy : High level accuracy with smooth & jerk free stopping. II. CAR a. Size of Lift Car inside : 2000 x 1100 ( mm Wide x mm Depth ) b. Design of lift car : SS finish car panel c. Car ceiling : SS false ceiling d. Car floor : granite / marble flooring e. Car fittings : LED ( JLPL77) & 300 mm REGULAR cabin (CIRCULAR) - 1 FAN. And energency light f. No. of opening : One ( In front only ) g.Car Entrance:Power operated V3F drive side opening S.S, sliding door - with provision for emergency key opening at all landings. h. Clear opening : 900 x 2000 ( mm Wide x mm Height )

1

-

-

... More
III. ENTRANCE a. Car :Power operated V3F drive side opening, SS sliding door - b. Landing Entrance Door : S.S door IV. OPERATION Microprocessor based Simplex, Collective, Selective control with / without attendant. V. Car and Landings :Digital floor position indicator in car and all landing. Dry cell operated alarm bell and emergency light with Automatic charging device, Up /Down Digital direction indications at all landings and in car. VI. STEEL LADDER FOR LIFT MACHINERY included in the estimate VII. SPECIAL FEATURE : Digital position indicator in Car and landings. Battery operated Emergency light and Alarm bell, call register signal and VF Door operator, false ceiling in Car. Infra red door screen, Vandal proof SS Button with SS cover / Automatic Rescue Device. Fire mans switch. Intercom provisions with Instruments and floor Annunciator. VIII. Automatic Rescue Device ( ARD ) : To facilitate landing of lift to the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger, inverter, under voltage protection system etc. complete with all accessories. IX. MINOR BUILDER WORK : included in the estimate X. SCAFFOLDING WORKS : included in the estimate XI. FREE SERVICE AND MAINTENANCE DURING THE GUARANTEE PERIOD OF ONE YEAR.

-

-

-

... More
a. Guarantee : Guarantee for materials and workmanship of equipment not less than one year. b. Free maintenance: Free comprehensive, servicing and maintenance during the guarantee period to be provided by the Lift contractor. And important necessary training of employees, for minor maintenance works and proper handing over of lift to be done by the lift contractor. c. Preparation of Drawings and obtaining CEIG's Safety Certificate for lift approval as per lift act with payment of necessary fees to CEIG and insurance policies. If any d. Site tests in accordance with IS 14665 shall be carried out at time of handing over. Architrave covering all the 3 sides of the entrance door with 3mm thick decolam sheet with cardboard upto a height of 1.5 mts from the silt level. Supply of operation and maintenance manual with necessary tools for operation. The list of tools required should be detailed by the contractor in a separate should duly signed by the contractor.

-

-

-

... More
VI. OTHER INCLUSIONS : Over speed Governor, phase failure and phase reversal relay, alarm bell, T. Guide brackets for car and counter weights, rubber padding under winding unit, Motor of adequate 7.5 HP capacity, electro magnetic brake with compression springs, car safety gear, buffer, electro mechanical door locks, tubular S.S hand rail in car. Steel ladder for machine room, Emergency key, motor over load protection devices, final limit switch, position and direction indicators for car and landing entrances, main suspension ropes, counter weights, lifting joists for mounting the machines S.S. facial plate for car operating panel & landing fixtures, fireman's switch and other necessary controls - complete set. (SR)

-

-

-

... More
160KVA DIESEL GENERATOR: Supply, Erection, commissioning, testing and handing over, obtaining permission from the CEIG, preparation of drawing and obtaining safety certificate for 1No 160KVA Diesel Generator Set canopy, fuel tank, battery charging alternator with AMF Panel developing 3phase electrical out put 160KVA, powered by diesel engine of 0.8P.F Three phase 415/420Volts, 50c/s, 222.6 BHP at 1500 RPM as per CPCB norms BS IV + as detailed below. a]. ENGINE: The engine has turbo charged vertical inline 6 cylinders. Water cooled diesel engine developing 222.6 BHP at 1500 RPM conforming BS 5514 / BS 649 or IS 10000 incorporating the following accessories. Engine instrument panel/mounting: Engine control panel consisting of ON/OFF/START/KEY, lube oil pressure gauge, oil temperature gauge, high water temperature gauge and electronic hour meter and RPM indicator. Safety system of Engine: The engines shall trip for the following conditions with Visual alarm device. 1) Low lubricating oil pressure. 2) High water temperature . 3) Vee - belt failure and over speed. 4) Low battery indication. The Engine should be capable of providing 10% over load for one hour for every 11 hours continuous running at full load. B.ALTERNATOR: 160KVA Capacity Brushless Alternator AC 3phase 50c/s 415/420V 0.8PF 1500 RPM under NTP conditions conforming to IS 13364 (part - II) 1992 to be means of coupling C)After Treatment System-The After treatment system should include SCR,DEF lines,DEF supply & DEF Tank D) AMF CONTROL PANEL: The AMF control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connecting incoming and outgoing leads have been made on the control panel complete set.

1

-

-

... More
1) 1No AC Ammeter. 2) 3Nos current transformer with suitable Ratio. 3) 1No Ammeter selector switch. 4) 1No AC voltmeter. 5) 1No Voltmeter selector switch. 6) 1No Frequency meter. 7) 1No KWH meter. 8) 1No power factor meter. 9) 1No KW meter. 10) Battery charging set comprising of the following for charging the battery from mains. a) Transformer/Rectifier, b) DC Ammeter,c) Charging rate selector switch, d) DC voltmeter , e) Circuit breaker, f) Voltage Regulator, g) ON/OFF switch. This will be in addition to auxiliary neutral contactor for battery charging alternator fitted to the Engine. 11) 1set Air break contactor with auxiliary neutral contactor for main supply , 12) 1set low voltage HRC fuse for the short circuit protection of the main supply. 13)1 set alternator contactor with auxiliary neutral contactor 14)1set three pole bimetal release for over load protection of the alternator. 15) 1set low voltage HRC fuse for the short circuit protection of the alternator. 16) 1set DC control relays incorporating engine start/ stop and failure to start/lockout. 17) 1set selector switch auto/manual. 18) 1No push button “Start”. 19) 1No push button “Stop”. 20) 1No push button “Reset”. 21) 1No signal lamp for indicating load on mains.

-

-

-

... More
22) 1No signal lamp for indicating load on set. 23) 1No signal lamp for indicating set fails to start . 24) 1No signal lamp for indicating ‘Set running’. 25) 1No signal lamp for indicating ‘Battery charger ON’. 26) 1set pilot lamps of 3Nos. 27) MCCB of 400A capacity with magnetic thermal over load release, instant short circuit trip and under voltage release switch. 28) Rectangular copper bus bars for 400A (1No for each phase, neutral and earthing terminal) capacity duly colour coded with heat shrinkable PVC sleeves. 29) 1No mains voltage monitor.30) Hooter/ Audio alarm for indication set fails to start and for DG O/ L. 31) 1set timers. 32) Audio and visual indication arrangements for , a) Low lubricating oil pressure, b) High water temperature, c) Over speed. 33) 1No Earth fault relay. 34) Isolator to Isolate the neutral.

-

-

-

... More
Note: 1. The control panel should be complete with necessary fuses, cables, labels, other accessories with neutral isolation arrangements. 2. The engine should trip for the following conditions. a) Low lubricating oil pressure, b) High water temperature, c) Over speed. 3.Supply and fitment of Auto mains failure panel to EB service with 400Amps switch and contactors with scuf control relays, timers etc. E) ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated of 16SWG CRCA MS sheet. The silent canopy shall be nut bolt type construction. Critical processes of punching are done on CNC machine to maintain dimensional accuracy of hole within 0.1mm, powder coating done after seven-tank surface preparation process of sheet metal. Canopy panel and door shall have inside lining of FIRE-RETARDANT 64kg/m density mineral wool of 100mm thickness as acoustic material. Four hinged doors shall be provided to canopy. The maximum permissible sound pressure level should be as per the norms prescribed by the Central Pollution Control Board/ State Pollution Control Board/ Competent Authority concerned or should be within 75 db(A) at 1 meter from the enclosure surface whichever is advantageous to the department. The emergency stop should be available on the enclosure panel. The enclosure provided shall be duly approved by the Engine Manufacturer of the Engine provided for Diesel Generator Set mounted inside and should be to the satisfaction of inspection/ testing authority concerned.

-

-

-

... More
SURFACE TREATMENT – PAINTING : The enclosure shall be suitably treated for degreasing, de-rusting and phosphating. The canopies are passed through seven-tank treatment thoroughly. ADDITIONAL FEATURES OF CANOPIES Canopy fabricated on CNC machines with dimensional accuracy of 0.1mm so as to increase its durability. Special designed supporting rips/structures are used in canopies so as to give sturdiness and to reduce the vibrations of the DG sets if any. WORLD CLASS COOLING PACKAGE: Canopies shall have cooling package for which it can perform at 45 deg C ambient temperature. No grounding required on the ground, only a level surface capable of with standing the DG weight. Lifting hooks shall be provided for the acoustic enclosure, which should be unloaded independently of the DG set. The Gen set frame shall also be provided with hooks for unloading. Temperature rise inside the canopy: Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well with in 5-7 deg centigrade. Base Frame Base frame should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure on it. The supply of Gen set includes loading, unloading and transportation charges.

-

-

-

... More
E) Fuel Tank Removable Fuel tank of atleast 440 Ltrs capacity shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for cleaning or any maintenance. First charging of fuel oil to full capacity and first charging of battery while handing over to the department. Also supply of fuel oil to run the genset for a minimum of 8hours on load or by using water rheostat or suitable loading element. F) Battery 2Nos 12V 180 AH battery G) Tools: Supply of tools like 15" cutting plier - 1No, Screw Driver 9" & 6" - 2No, DE Spanners (6Nos) - 1set, Adjustable spanner - 1no, 1/2 lb Hammer - 1No, Spanner for removing engine oil plug - 1No, Line Tester - 1No for the maintenance and operation of Generator set. SR M-2331

-

-

-

... More
ERECTION, TESTING AND COMMISSIONING: Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation for erection of 125KVA Diesel Generator set upto a height of 1 meter from the floor level.

1

-

-

... More
Exhaust Piping: Supply and installation of exhaust piping of sufficient length with suitable MS pipe so as to exlend outside the generator with necessary thermal insulation. (SR)

3

-

-

... More
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. (SD-76)

25

-

-

... More
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection (SD 371)

50

-

-

... More
Supply and Fixing of 16A Two-way switch in suitable MS box on wall with earth connection.(HIGHER END) (For 4 Nos. Lift (DATA-13)

4

-

-

... More
Supply and fixing of 32A TPNMC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only. (SD-148) (pump room)

1

-

-

... More
Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour. (SD-55) (for 6A plug)

100

-

-

... More
Supply and run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion. (SD-337) (for 3x6A plugs)

850

-

-

... More
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour. (SD-57) (for AC plugs, 16A plugs & LDB's)

995

-

-

... More
Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm copper wire and making good of the concealed portion with suitable colour. (SD-59)

400

-

-

... More
Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm copper wire and making good of the concealed portion with suitable colour. (SD-63)

50

-

-

... More
Supply and Run of 3 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed position.(SD-345) (for cassette type outdoor to indoor) (DATA-14)

40

-

-

... More
Supply and run of 4 of 16 sq.mm PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 16 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour. (DATA-15)

300

-

-

... More
Supply and run of 4 of 25 sq.mm. PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 25 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour. (DATA-16)

105

-

-

... More
Supply and laying of 4 x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metreputting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.(SD 180)

58

-

-

... More
Supply and clarnping of 4 x 10 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamp (SD 198)

10

-

-

... More
Supply and fixing of brass cable gland for 4 x 10sq.mm. PVC armoured LTUG cable with earth connection.( DATA-17)

2

-

-

... More
Supply and providing cable end termination of 4 x 10 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. (DATA-18)

2

-

-

... More
Supply and laying of 3½ x240 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD-190)

35

-

-

... More
Supply and clarnping of 3½ x 240 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.(SD-208)

15

-

-

... More
Supply and fixing of brass cable gland for 3½ x 240 sq.mm. PVC armoured LTUG cable with earth connection. (SD-172)

4

-

-

... More
Supply and providing cable end termination of 3½ x 240 sq. mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. (DATA-20)

4

-

-

... More
Supply and Laying of 3½ x 185 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (For Generators) (SD-666)

20

-

-

... More
Supply and clamping of 3½ x 185 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. (SD-207)

10

-

-

... More
Supply and fixing of brass cable gland for 3½ x 185 sq.mm. PVC armoured LTUG cable with earth connection. (SD-171)

2

-

-

... More
Supply and providing cable end termination of 3½ x 185 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. (SD-220)

2

-

-

... More
Supply, Fabrication, Erection, Testing and commissioning of indoor dust and vermin proof four compartment CT Metering panel made up of 16SWG CRCA sheet of size 48" x 48" x 18" with necessary stiffner and provided with following arrangements. 1. Front open door for each compartment provided with sealed locking arrangement. 2. 6mm thick hylem sheet in metering compartment for fixing 3phase 415V 4wire 50Hz Digital Energy meter provided by TANGEDCO. 3. 3Nos 1.5" x 1/4" and 1" x 1/4" Copper bus bar on suitable bus support with 3Nos 315/5A CTs in bus bar compartment. 4. 3Nos 315A fuse unit & 1no 250A neutral link on 6mm thick hylam sheet in fuse comparment. 5. Fixing of control fuses and wiring with flexible PVC copper wire and LED Indicator arrangements. 6. 2 Nos copper earth bus of 1" x 1/8" in the rear side. 7. Suitable MS base channel for mounting. 8. Viewing glass in the door for meter compartment. 9. Provision of cable entry and outgoing compartment. 10. Painting the panel with 2 coats of epoxy paint over one coat of red oxide. (DATA-21)

1

-

-

... More
Supply and fixing of 3 Phase 315A aerial fuse unit for 3Nos 315 A fuse units (500V) on suitable MS sheet covered with 6mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps. . (DATA-22)

1

-

-

... More
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125 mm x 50 mm x 6 mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. (SD-211)

12

-

-

... More
Supply of air termination rod of 3 mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type) Test Parameter for 4 mtr vertical air terminal a)ELectrical Resistivity b) Tensile Strength c) Condition of Salt Mist (M-2562)

4

-

-

... More
Supply and Installation of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µΩm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2. (M-2559)

200

-

-

... More
Supply and Installation of Stainless Steel 304 grade Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor. Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1 (Article No. 404 214) (M-2565)

4

-

-

... More
Supply and Installation of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil. Test parameter: a) Short circuit current test for copper bonded conductor:Test 6 kA ratings, as per cross sectional area for 1 sec (IS3043/IEEE80); b)Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. c)Tensile Test 290 to 510 N/mm². d)Adhesion no peel or crack & Bend test no seperation of Cu, e)Cu Coating thickness min. 70µm. Tested as per IEC 62561-2. (M-2566)

40

-

-

... More
Supply and Installation of Stainless steel SS 304 Grade Conductor Holder for fixing the 8 -10 mm dia round conductor on the wall . Test Parameter: a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4 (M-2567)

15

-

-

... More
Supply and Installation of Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 17.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467. Supply and Installation of earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7 -25 kg Supply and Installation of Earth rod clamp made for terminating cable / flat conductor.(M-2568)

4

-

-

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.