Public Works Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date2 Nov 2024
Closing Date4 Nov 2024
Tender Amount₹ 33,61,933
Costs
EMD
₹ 26,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_497433_1Bid Award Id
ViewTender No
6/KPM/2024-2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Stage – 1: Spraying anti-termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation. Stage – 2: Spraying anti-termite chemical solution to the grade beam level, spraying has to done for the grade beam, brick masonry contact with the back fill earth. Stage – 3: Spraying anti-termite chemical solution on the sand for the flooring before laying the flooring concrete. This treatment has to be carried out on the sand filling by making holes with crow bar to a depth of 60cms and at 60cms intervals on both direction and at junction of wall and flooring throughout. Stage – 4: Spraying anti-termite chemical solution alround building outside by making holes through bar before laying plinth protection and the holes to be closed after the treatment
78.6
-
-
Supplying and filling in foundation, basement, etc with filling M-sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
16
-
-
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
24
-
-
Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
10
-
-
Brick work in following Cement Mortar 1:5 (One cement and Five M-sand) using best quality II class ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" including curing, etc., complete complying with standard specifiction.
-
-
-
For Foundation and Basement
8
-
-
Brick work in following Cement Mortar 1:6 (One cement and Six M-sand) using best quality II class ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" including curing, etc., complete complying with standard specifiction.
-
-
-
For Super Structure in Ground Floor
20
-
-
For Super Structure in First Floor
5.1
-
-
Providing Inspection Chamber of size 1.00 m x 1.00 m including necessary earth work, M-sand filling, 1:5:10 , Brick work in CM 1:3, plastering with C.M 1:3, PCC 1:2:4 and precast slab 50mm thick as diarected by the departmental officers, etc complete
3
-
-
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
58
-
-
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
-
-
-
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
142
-
-
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
81
-
-
Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/mᶾ and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
-
-
-
For Foundation and Basement
26
-
-
For Super structure in Ground Floor
22
-
-
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
50.5
-
-
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
79
-
-
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
6
-
-
Supplying and fixing of Vinyl Flooring of 2mm thick as approved quality and best variety cost includes cleaning the surface, transportation charges and other incidental charges etc., complete
66
-
-
Paving the Floor with Matt finish Vitrified Tiles of size 600 x 600 x 8mm in all floors over a base layer of cement mortar 1:3 (One Cement and Three M-sand) 20mm thick and pointing with the same coloured cement neatly and fixed in position so as to make it perfectly smooth and shining to the alignment etc., complete complying with standard specification and as direted by the departmental officers. (The sample of colour and shade of the ceramic tiles should be got approved by Executive Engineer before use on works)
8
-
-
Dadooing walls with glazed finish Vitrified tiles of size 600mm x 600mm x 8mm sizes set in Cement Mortar 1:2 (One Cement and Two M-sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
35
-
-
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
6
-
-
Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level.
60
-
-
Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc.,
15.6
-
-
Supplying and fixing Medium density fibre board door of exterior grade (Plain) 35mm thick shutter conforming to I.S. 12406/1989 with external teak wood lipping of size 35x12mm on all edges with necessry adhesive and C.P. Screws, including fixing for aldrop, tower bolt, hinges and lock strike plates, putty, fevical, painting the teak wood lipping etc., and including the cost of alumnium hinges 125x30mm size - 6 Nos. aluminium aldrop of size - 250x16mm 1No , Aluminium tower bolt of size 250x12mm -2 No , tower bolt of size 200x12mm -1 No, D type aluminium handle of size 200mm -2 No , aluminuim door stopper with Nylon bush - 2 No . shall be provided. All aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1968 for anodic film thickness of not less than 15 microns. The rate is inclusive cost of fevical and fixing charges, transportation, loading, unloading and all other incidental charges, handling charges, etc., complete complying with standard specification. ( Double leaves )
-
-
-
Double leaf
6.15
-
-
Supplying and fixing Ornamental Teakwood entrance door with overall size of 3.70m x 2.45m with two leaves have openable shutter and two end portions are fixed as per the design of approved by the departmental officers. The outer frames are three horizontal and four vertical of size 150 x 100 mm teakwood scantlings.The Shutter frames are 100 x50 mm teakwood scantlings. The shutter shall have 2.10m height with two panels using teakwood planks of 40mm thick and finished with approved patten and carving work with skilled carpenter as directed by the departmental officers. The top portion 0.40m height with fixed glazing shall be covered with plain glass of 8mm thick with MS grill.The side fixed portion having bottom 1/3 panaled with teakwood planks of 40mm thick and top 2/3rd with fixed glazing shall be covered with plain glass of 8mm thick with MS grill. The rate includes cost of best and approved quality of Teakwood, Teakwood reeper 50x25mm,carving work, Brass hinges, Tower bolt, Aldrop, locking arrangements, Ornamental Handles, brass screws and labour charges for handlings, fixing charges, conveyance charges etc., The door frame and shutters shall be given two coats of best and approved quality of Lac polishing etc., complete complying with standard specification.
3.8
-
-
Supplying and fixing of wood polymer composite (WPC) door with solid door frames extruded with size 75mmx50mm. The inner core made of rigid WPC compound with minimum shore hardness of 55 and buld density 750kg/cub.Mt. The frame shall be fixed to the wall using 10x10mm long MS screw throught the frame by using PVC fasteners. A minimum of 4nos screw to be provided for each vertical members, Door Shutter of 25mm thick Wood Polymer Composite (WPC) single core Extruded Door Shutter, with one side digital printing of specified Design which is approved by engineering-in-charge. Both side of the shutter shall have rough sugar texture finish, laminated with UV oil. The solid WPC board shall have minimum shore hardness of 55 and Bulk density 550kg/cub.Mt moulding the thickness remains 25mm (+/-1mm) etc. complete as per the direction of the departmental officers.(make Qute / Equivalent)
1.9
-
-
Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
224.25
-
-
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
9
-
-
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
0.55
-
-
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
-
-
-
110mm dia PVC Rain water downfall pipe
14
-
-
Supplying and fixing of Best Quality branded European Water Closet with "P" or "S" trap and with ISI mark. The cost is include of double flapped PVC seat cover, PVC pipe 110mm dia and all internal fittings and with necessary CI brackets, 12mm brass nipple 15mm dia chromium plated brown headed stop cock of approved quality with ISI mark and nylon connection including fixing the same to wall and giving necessary water supply connection with all internal fittings with labour charges. The European water closet should be fixed on the floor using counter sunk bolts and nuts and necessary teakwood plugs, clamps, screws etc., including dismantling the floor or wall wherever necessary and redoing the same to their original condition etc., complete
1
-
-
Supplying and fixing of Best Quality branded Gem rectangle wash basin with necessary fittings cost includes transportation, labour and other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
1
-
-
Supplying and fixing Best Quality Branded S Square Head Shower with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers. (The shower should be got approved by the Executive Engineer before use on works).
1
-
-
Supplying and fixing of Best Quality project pillar tap including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
1
-
-
Supplying and fixing of Best Quality Project two way BIB tap including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
1
-
-
Renewing and fixing of Best Quality Project three in one wall mixer including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
1
-
-
Supplying and fixing in position of best quality and brand mirror of size 600 x 450 x 5.5mm thick mirror of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on works)
1
-
-
Supplying and fixing in position of best quality and brand soap tray fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The soap tray should be got approved by the Executive Engineer before use on works)
1
-
-
Supplying and fixing in position of best quality and brand towel rail fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The towel rail should be got approved by the Executive Engineer before use on works)
1
-
-
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
1
-
-
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
-
-
-
32mm dia G.M. Gate valve
1
-
-
25mm dia G.M. Wheel valve
1
-
-
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
-
-
-
110mm dia PVC Soil Pipe
30
-
-
75mm dia PVC Soil Pipe
18
-
-
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
-
-
-
110mm dia PVC Door Elbow
2
-
-
110mm dia PVC Plain Bend
2
-
-
110mm dia PVC Door Tee
2
-
-
75mm dia PVC Door Elbow
2
-
-
75mm dia PVC Plain Bend
3
-
-
75mm dia PVC Door Tee
2
-
-
Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. (Above Ground Level) (Internal Water supply)
-
-
-
32mm dia UPVC pipe
18
-
-
25mm dia UPVC pipe
30
-
-
20mm dia UPVC pipe
16
-
-
Supplying UPVC Specials in water supply arrangements (both in internal and external water supply arrangements.
-
-
-
32mm dia UPVC Tee
2
-
-
25mm dia UPVC Tee
2
-
-
20mm dia UPVC Tee
3
-
-
32mm dia UPVC Elbow
3
-
-
25mm dia UPVC. Elbow
2
-
-
20mm dia UPVC Elbow
3
-
-
32X25mm dia UPVC Reducer Tee
2
-
-
25X20mm dia UPVC Reducer Tee
2
-
-
20X15mm dia UPVC Reducer Tee
3
-
-
25X20mm dia UPVC Reducer Elbow
3
-
-
32X25mm dia UPVC Reducer Elbow
3
-
-
Supplying and fixing of Door and window curtains by using of High quality fabric for VVIP and VIP Suites cost includes stiching, fixing charges, transportation charges and other incidental charges etc., complete.,
26.35
-
-
Supplying and fixing of Ornamental design anchor rod with special maded clamps cost includes stiching, fixing charges, transportation charges, screws, drilling and other incidental charges etc., complete.,
8
-
-
Supplying and fixing of Ornamental teak wood King size cot of size 6' x 6-6" and including cost of transportation charges and other incidental charges etc., complete
1
-
-
Supplying and fixing of King size Matress of size 6' x 6-6" with two pillow sets and including cost of transportation charges and other incidental charges etc., complete
1
-
-
Supplying and fixing of best quality side tables of following sizes cost includes fixing charges, transportation charges and other incidental charges etc., complete
-
-
-
1.00 x 0.45 x 0.50 m
1
-
-
1.20 x 0.60 x 0.50 m
1
-
-
0.45 x 0.45 x 0.50 m
1
-
-
Supplying and fixing of best approved quality Dressing table cushion chair of size 0.45 x 0.35 x 0.45m Cost includes tranportation charges and other incidental charges etc., complete
1
-
-
Supplying and fixing of Three Seated Sofa 1 No. of size 2.00 x 0.75 m, two seated sofa 1.45 x 0.75 m with Single seated sofa of size 0.90 x 0.75 m cost includes tranportation charges and other incidental charges etc., complete
1
-
-
Supplying and fixing of following sizes Dressing table by using 12mm - 8mm tk plywood and finishing with premium sunmica sheet etc., one side designed full size mirror for dressing purpose and other side dressing compartments, cost includes lock, handles, tranportation charges and other incidental charges etc., complete
-
-
-
Dressing table of size 1.75 x 2.10 m
1
-
-
Renewing and fixing of netlon door mesh with openable steel frame of size 0.050x0.025 for Horizontal and vertical with cross beading of size 0.025mmx0.025mm for both side and centre portion filled with SS Netlon mesh and fitting the same in position. The cost includes transportation charges and all other incidental charges etc., complete.
9.55
-
-
Supply and fixing of best quality pressure motor of 1.00 HP with pressure measuring gauge cost includes fixing, wiring, transportation and other incidental charges, etc., complete
1
-
-
Supplying , fixing of cylindrical vertical notational polythene water storage tank of 1000 litres capacity confirming to IS 12701/96. the tank is meant for outer (or) indoor, use complete with removable hinged top locking arrangements and to make provision to fix with simply pipe lines necessary manhole with cover and including all PVC specials, plugs, screws, nails to fix the tank etc., (The water tank should be got approved by the Executive Engineer before use on work .
1
-
-
Supplying and applying of Two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the departmental officers. (The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet) cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc., complete). The putty should be got approved by the Executive Engineer before use on work
79
-
-
Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The wall putty shall be got approved by the Executive Engineer before use of work).
90
-
-
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
110
-
-
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick with admixture in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
300
-
-
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
450
-
-
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
9
-
-
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
13.55
-
-
Providing rain water harvesting recharge Perculation pit for a total depth of 1.95m,for which 0.45m depth in natural soil pit with 0.80m dia balance depth (well ring size of dia 0.90m and 0.30 depth) covered with RCC cover slab of 75m thick of 1.00m dia and thus the top of well ring kept 0.15m above the ground level, and filling the recharge pit with M-sand and 40mm for 0.30m depth and 1.05m depth respectively and balance depth of 0.60m is kept as freeboard for RCC percolation pit. the rate is includes cost of all materials such as Rc well ring, Rc cover slab, 40mm HBS jelly M-sand at site of work and labour charges for fixing wellring, cover slab in position and filling M-sand and 40mm metal.
1
-
-
GST @ 18 %
1
-
-