Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Public Works Department - PWD Tender
Civil And Construction
Eprocure
Opening Date27 Sep 2024
Closing Date17 Oct 2024
Tender Amount₹ 74,57,055 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Dlf Collection Yard Udhagamandalam
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_488762_1Bid Award Id
ViewTender No
07BCMCBE24092024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and Filling in Foundation and Basement with Crushed Stone Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
27
-
-
Supplying and Filling in Foundation, Basement with CONVEYED GRAVEL not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
23
-
-
Refilling Basement with Excavated Earth (other than CS sand) in layers of not more than 15cm thick watered, rammed well and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
36
-
-
CEMENT CONCRETE 1:5:10 [One Cement, Five CS Sand and Ten hard broken stone jelly] using 40 mm gauge hard broken granite stone jelly for FOUNDATION including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification.
16
-
-
Supplying and erecting steel Shuttering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as COLUMN FOOTINGS, COLUMN PEDESTALS, PLINTH BEAMS, GRADE BEAMS, STAIRCASE STEPS, etc., which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. [Payment for centering shall be given after the concrete is laid].
100
-
-
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height For plane surfaces as detailed below , in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid).
-
-
-
FOR PLANE SURFACES SUCH AS RCC FLOOR SLAB, ROOF SLAB, RECTANGULAR BEAMS, ELL BEAMS, LINTELS, LANDING WAIST SLAB, CANOPY SLABS BED BLOCKS etc.,
315
-
-
FOR PLANE SURFACES SUCH AS RECTANGULAR OR SQUARE RCC COLUMNS TOP AND BOTTOM SLABS OF RCC BOXING SILL SLAB AND SUNSHADES ETC.
145
-
-
BRICK WORK in Cement Mortar 1:6 [One Cement and Six CS Sand] using best quality Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].
-
-
-
For Foundation & Basement
18
-
-
For Superstructure in Ground Floor
26
-
-
BRICK WORK in Cement Mortar 1:5 [One Cement and Five CS Sand] using best quality Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].
-
-
-
For Foundation & Basement
9
-
-
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/Cu.m and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu'm') 7670 kg. of cs sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
-
-
-
For Foundation & Basement
67
-
-
For Superstructure in Ground Floor
52
-
-
Supplying, fabricating and placing in position MILD STEEL / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. [Contractor has to make his own arrangements for the supply of steel and binding wire]
128
-
-
CEMENT CONCRETE 1:5:10 [One cement, Five CS sand and Ten hard broken stone] using 40 mm gauge hard broken jelly for FLOORING including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. [The rate is inclusive of necessary planking for panelling wherever necessary and complete complying with standard specification and as directed by the departmental officers.
16
-
-
PLAIN CEMENT CONCRETE 1:2:4 [one cement, two CS Sand and four hard broken stone jelly] using 20 mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
47
-
-
Finishing the top of roof with one course of Machine Pressed Tiles of size 23cm x 23cm x (1.6-1.8)cm of approved quality set in Cement Mortar 1:3 (One Cement and Three Cs Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
207
-
-
DADOOING walls with printed design colour glazed tiles of size 300 mm x 450 mm x 8 mm sizes set in Cement Mortar 1:2 [One Cement and Two Crushed Stone Sand] 10 mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg/m2 neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
77
-
-
STUCCO PLASTERING 12mm thick using blue granite chips of size 10mm and below over the existing base plastering with cement mortar 1:5, 12mm thick mixed with Bonding agent cebexl 112,Zydex -Zycrete 2x or ther equivalent in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
80
-
-
PLASTERING with Cement Mortar 1:5 (One cement and Five P-sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
151
-
-
SPECIAL CEILING PLASTERING and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P-Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equivalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
369
-
-
Providing GRANOLITHIC FLOOR finish of 25mm thickness with Plain Cement Concrete 1:2:4 [One Cement, Two Crushed Stone Sand and Four Aggregate] using 10 to 12 mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc., complete complying with standard specification and as directed by the departmental officers. [The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers].
30
-
-
Supplying and fixing of Hollow Pressed Steel Door Frames for single leaf and double leaved door using pressed steel frame of size 105x60mm using mild sheet of 1.25mm thick (18gauge) special profile extruded section.The pressed steel frame should be as per IS4351/1976.The rate in inclusive of bottom thehold fasts and provision to aldrip tower bolt hinges and lock plate etc,with one coat of zinc chnomate yellow primer and filling the inside hallow portion with cement concrete 1:2:4 using 20mm HBG stone jelly etc,complete complying with standard specification and as directed by the departmental officers.
6.5
-
-
Supplying and fixing Solid Core Particle Board Flush Shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround Commerical ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 300x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers.
-
-
-
Double Leaves
3.3
-
-
UPVC Window: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
35
-
-
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work.
13
-
-
Supplying and fixing MS Grills for windows, ventilators, etc., including priming coat etc., complying with standard specification and as directed by the departmental officers.
1190
-
-
Painting two coats of newly plastered wall surface with Ready Mixed Plastic Emulsion Paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
361
-
-
Painting two coats with approved Weather Proof Exterior Emulsion Paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specifications and as directed by the departmental officers.
242
-
-
Painting NEW IRON works such as steel doors, windows, ventilators, window bars, balustrades etc., with TWO COATS of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. [The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.]
50
-
-
PAINTING NEW WOOD WORKS with TWO COATS of synthetic enamel paint of approved quality and colour over a priming coat with approved quality of white primer in all floors. The rate is inclusive of cost of all materials and labour, brushes and scaffolding charges etc., complete complying with standard specification. (The paint to be used should be got approved by the Executive engineer before use on work.
8
-
-
GST @ 18%