Public Works Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date10 Oct 2024
Closing Date29 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 1,34,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_492559_1Bid Award Id
ViewTender No
11BCMCBE08102024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and filling in foundation, basement with CONVEYED EARTH not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
145
-
-
Supplying and Filling in Foundation and Basement with Crushed Stone Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
111
-
-
BRICK WORK in Cement Mortar 1:6 [One Cement and Six CS Sand] using best quality Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].
-
-
-
For Foundation & Basement
48
-
-
For Superstructure in Ground Floor
65.5
-
-
For Superstructure in First Floor
78
-
-
BRICK WORK in Cement Mortar 1:5 [One Cement and Five CS Sand] using best quality Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].
-
-
-
For Foundation & Basement
21
-
-
DAMP PROOF COURSE with Cement Mortar 1:4 [One Cement and Four CS Sand] 12mm thick with Bonding agent Cebexl 12, Zydex -Zycrete 2X or other equalent compound conforming to BIS at 200ml of one cement bag (50kg) for increased workability and air entrainment used finishing mixed with best approved quality water proofing compound conforming to Indian standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc., complete complying with standard specification.
78.5
-
-
Supplying and erecting steel Shuttering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as COLUMN FOOTINGS, COLUMN PEDESTALS, PLINTH BEAMS, GRADE BEAMS, STAIRCASE STEPS, etc., which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. [Payment for centering shall be given after the concrete is laid].
420.5
-
-
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height For plane surfaces as detailed below , in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid).
-
-
-
FOR PLANE SURFACES SUCH AS RCC FLOOR SLAB, ROOF SLAB, RECTANGULAR BEAMS, ELL BEAMS, LINTELS, LANDING WAIST SLAB, CANOPY SLABS BED BLOCKS etc.,
1153
-
-
FOR PLANE SURFACES SUCH AS RECTANGULAR OR SQUARE RCC COLUMNS TOP AND BOTTOM SLABS OF RCC BOXING SILL SLAB AND SUNSHADES ETC.
425
-
-
FOR PLANE SURFACES SUCH AS VERTICAL SLAB, SIDE SLABS OF BOXING, VERTICAL DROPS, FACIA, VERTICAL WALL, ETC.
174.5
-
-
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/Cu.m and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu'm') 7670 kg. of cs sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
-
-
-
For Foundation & Basement
148
-
-
For Superstructure in Ground Floor
92
-
-
For Superstructure in First Floor
88
-
-
Supplying, fabricating and placing in position MILD STEEL / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. [Contractor has to make his own arrangements for the supply of steel and binding wire]
390
-
-
CEMENT CONCRETE 1:5:10 [One cement, Five CS sand and Ten hard broken stone] using 40 mm gauge hard broken jelly for FLOORING including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. [The rate is inclusive of necessary planking for panelling wherever necessary and complete complying with standard specification and as directed by the departmental officers.
42
-
-
BRICK PARTITION walls of 11.00 cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7cm in Cement Mortar 1:3 [One Cement and CS Sand] using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers.
-
-
-
For Superstructure in Ground Floor
9.5
-
-
For Superstructure in First Floor
9.5
-
-
Paving the floor with best approved quality fine polished Kota stone slabs of 20mm thick with machine cut edges of size below 600x600mm laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with matching colouring pigments etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
690
-
-
Supplying and fixing fine polished cuddapah slab of 38/40mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed.
22
-
-
Providing water proof paint one coat over top of roof slab with the following specifications. The Surface shall be cleanined to remove all dust for in matters loose materials are any other deposits of condemination by rubbing with wire brush. Applying tow component elesotomeris acrylic polymer modified cementation water proofing coating smar care damp black 2K having 80% elongation as per ASTM D 412 resisting 5 parts hyrostatic pressure as per DIN 1048 reduction to repaired cloride shall be 70 as per DIN 1048, crackbriding upto 1.2mm as per ASTM 4548.5. The mixing ratio coating shall be two parts of powder and one part of liquid without any water addition etc., complete. The rate is inclusive of cost of materials, transportation, laour charges.
442
-
-
WEATHERING COURSE concrete in brick jelly lime concrete using broken brick jelly of size 20 mm uniform gauge in pure slaked lime [no sand to be used] to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.[FIRST FLOOR]
35.5
-
-
Finishing the top of roof with one course of Machine Pressed Tiles of size 23cm x 23cm x (1.6-1.8)cm of approved quality set in Cement Mortar 1:3 (One Cement and Three CS Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
442
-
-
Supplying and fixing in position Steel balustrades using 20mm square rods spaced at 150mm centre to centre so that the two balustrades in each step shall be placed centrally and the top of balustrades connected with the hand rails (cost of hand rail shall be measured and paid separately) by means of MS flats of size 40mm x 6mm in the groove 40mm x 6mm provided at the bottom of hand rail; the bottom of balustrades shall be fixed on to the top of step concrete. An additional MS flat of size 50mm x 6mm shall be provided at the centre of balustrades connecting all square rods to the entire length including cost of square rods, flat and applying one coat of red oxide primer to the iron surfaces, etc., complete complying with standard specification and as directed by the departmental officers.
18.5
-
-
Supplying and fixing 40mm dia GI pipe for staircase hand rail including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers.
20.5
-
-
Manufacturing supplying and fixing of STEEL DOOR [DOUBLE LEAVES] with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x6mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one
25.5
-
-
more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete.
-
-
-
Fabricating, Supplying and fixng in position of Steel Sheeted Windows (Three Leaves) with the following specifications. Outer frames of windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion 'J' section (F4B) of size 46x25x3mm at 2.28kg/m and shutter section of made of F7D of 33x25x3mm at 1.419 kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS Flat at 0.70kg/m at 3 Nos. for each shutter and additional diagonal stiffners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly.
49.5
-
-
2 numbers of sturdy hinges and one number of handle-cum-latch of special type made with 18x5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation. a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. each window shutter having an adustable stay made out of 18 x 5mm at 0.70 kg/ m MS flat of lenght 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18x5mm at 0.70kg/m, welded to the shutter at two place equivalent from each from top and bottom of the shutter.
-
-
-
An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers.All sections should be in confirmed with IS 7452/1990.The cost includes cost of all materials, labour charges and other incidental charges, etc., complete.
-
-
-
Fabricating, supplying and fixing of Steel Emergency exitdoor cum, emergency window with the following specification. M.S. angle in size 40x40x6mm are used for the outer frames and M.S. angle of sie 35x35x5mm for the shutter frame, stiffners with 32x6mm M.S. flats provided at required intervals in the shutter frames 18 guage CR sheet is laid as panel and welded instant for 1/3 bottom portion of the shutter, M.S. flat 18x5mm is welded over the 32x6mm M.S flat sandwitching the CR sheet in between additional stiffner with 18x5mm M.S. flat is provided diagonally at the rear-side of the shutter.
25.5
-
-
Manufacturing, supplying and fixing of STEEL DOOR (DOUBLE LEAVES - 1/3 panneled& 2/3 grilled) with the following specification M.S angles of a size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32x6mm M.S. flat is provided at required intervals in the shutter frames 18 gauge C.R. sheet is laid as panel in the shutter and welded intact for 1/3 bottom portion of the shutter. M.S. flat 18x5mm is welded over the 32x6mm M.S. flat sand witching the CR sheet in between. Additional stiffener with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 20kg/sq.m and 6 Nos hinges for double leaves shutter to be provided 6nos of holdfasts 120mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 2nos. one at top and the other at the bottom arte provided one aldrop is provided at on appropriate place in the door. A Tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation or fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all meterials, labour ,charges, taxes, ransportation to site of work, loading, unloading and all other incidental charges etc., complete.
12
-
-
Supplying and fixing M.S. Grill for openings corridor side ladder, Entrance Gate and Name Board angles etc., using M.S. flats for inner and outer members which should be fixed as directed by the departmental officers including cost of providing one coat of red oxide primer. The design of MS Grill should be got approved from the departmental officers before use on work.
1110
-
-
PLASTERING with Cement Mortar 1:5 (One cement and Five p.sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equivalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
1582
-
-
SPECIAL CEILING PLASTERING and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P.Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers.
1184
-
-
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
1660
-
-
Painting two coats with approved Weather Proof Exterior Emulsion Paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specifications and as directed by the departmental officers.
1107
-
-
Painting NEW IRON works such as steel doors, windows, ventilators, window bars, balustrades etc., with TWO COATS of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. [The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.]
290
-
-
Providing BLACK BOARD in two layers with first layer in Cement Mortar 1:5 (One Cement and Five crushed stone Sand) 20 mm thick and the second layer in combination mortar 1:1:6 (One Cement One Lime and Six cs Sand) 20 mm thick and providing band all round the Black board in C.M 1:5 (One Cement and Five cs Sand) for 20 mm thick and 50 mm width including cost of one coat of black oxide paint of approved quality complying with standard specifications and as directed by the departmental officers.
47
-
-
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).
37
-
-
Providing GRANOLITHIC FLOOR finish of 25mm thickness with Plain Cement Concrete 1:2:4 [One Cement, Two Crushed Stone Sand and Four Aggregate] using 10 to 12 mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc., complete complying with standard specification and as directed by the departmental officers. [The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers].
100
-
-
Providing ANTI-TERMITE treatment to soil adjacent under building foundation, plinth periphery of the building by application of chemicals of ISI 6313-1981 part I to IV in stages to suit the progress of work as per the detailed specification (Measurements taken for the plinthe area for the purpose of payment) including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and incliding cost of chemicals, labour charges, transport and storing etc., complete complying with the standard specification and as directed by the departmental officers.
366
-
-
Stage.I. spraying anti- termite treatement chemicals solution for foundation concrete surface laying the foundation concrete bottom and sides of the foundation.
Stage.II. Spraying anti-termite chemical solution to the grade beam level, spraying for the grade beams, brick, masonry in superstructure in contact with the back fill earth.
Stage.III. Spraying anti-termite treatment, chemicals solution on sand for the flooring before laying the flooring zone, Treatment has tobe carried out by making crow bar holes at an interval of 12" to a depth of 8" on the sand filling in basement and after levelling operation is over.
Stage.IV. Spraying anti-termite treatment chemicals solution around the building (out side) by making crow bar holes at an interval of 12" to a depth of 8" in the periphery of building and chemical poured inside the holes and closed after the treatement.
-
-
-
Providing single nosing to the fine polished kota stone slab of approved quality and best variety complete complying as per standard specification