Public Works Department Tender

... More
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date4 Mar 2025
Closing Date18 Mar 2025
Tender Amount₹ 15,66,10,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing of 4 way 7 segment triple pole neutral MCB distribution board in sheet steel enclosure double door type with metal door with IP 42 protection with 63A 4 pole MCB as incoming and 3Nos 63A DP RCCB as sub incomer and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (Higher End)

17

-

-

... More
to provide double earth connection. The panel should be painted with two high quality ename paint over one coat of red oxide primer, the cable size capcity of switch loaction etc, should be marked with white paint and metalllic danger board affixed complete with mounting on base channel 3"x11/2"x1/2" iron frame work support complete (The TPN switches should be L& T/ siemens make only.) (Incoming supply)

-

-

-

... More
Providing Cornice Work for Hilux (or) Equivalent Board False False Ceiling

257

-

-

... More
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the departmental officers.

74

-

-

... More
In Ground floor.

209

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

6540

-

-

... More
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.

100

-

-

... More
Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm copper wire and making good of the concealed portion with suitable colour

280

-

-

... More
Supply and fixing of 63A, 10kA FP MCB in sheet enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End).

6

-

-

... More
3.Supply and fitment of Auto Mains Failure Panel, 1 EB Service wih 250 Amps switch and contactors SUF Control relays, timers etc suitable for auto change over of DG & EB Service.

-

-

-

... More
(C) Engine Instrument Panel / Mounted: Starting push botton / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechnical ) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load.

-

-

-

... More
110 mm Dia PVC Y with Single Door

12

-

-

... More
38. Special features: a. Infra red door sensor with full height screen. b. Tubular S.S hand rail in cars. c. Voltage stabilizer for circuit control. d. Stainless Steel signal fixtures. e. Vandal proof S.S. Button with S.S. cover f. SS hairline finish door frames for landing doors.g. VF door Register signal h. Call Register signal i. Stainless steel facia plate for car operating panel and landing fixtures. j. Steel ladder for machine room and ladder for lift Shaft pit, k. On – Off switch for fan and light l. Over load warning indicator With audio announcement.

-

-

-

... More
1. The control panel should be complete with necessary fuses, cables, label, other accessories with neutral isolation arrangements. 2. The engine should trip for the following: a) Low lubricating oil pressure b) High water temperature c) Over speed

-

-

-

... More
Providing and laying in position, standardised concrete Mix M-25 Grade in accordance using 20mm with IS:456-2000, and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kgm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 k9. of 20mm machine crushed stone jelly and with about (3'3 cu'm') 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu'm') 7670 kg' of M-sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).

-

-

-

... More
Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition of size 2.70 mx 2.10 m.The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 4 mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes in RCC column,masonry wherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing as directed by the departmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineer before use.

231

-

-

... More
Damp proof course with Cement Mortar 1:4 (One Cement and Four p sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification.

10

-

-

... More
Supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod with fan clamp with side plates and cross arm of size 450mm (18").

165

-

-

... More
4. Frequency meter

-

-

-

... More
Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)

2

-

-

... More
Supplying and erecting steel centering including supports for plain surfaces for reinforced cement concrete work such as column footings, column pedestals, grade beams, plinth beams, staircase steps, critical piers, etc., which require only nominal stutting using mild steel sheets of size 90cm x 60cm of B.G.10 stiffened with welded mild steel angles of size 25 mm x 25 mm x 3 mm boarding laid over silver oak (or) country wood joists of size 10 cm x 6.5 cm spaced at about 90 cm centre to centre and supported by casuarinas props of 10cm to 13 cm dia spaced at 75 cm centre to centre at suitable intervals etc., complete complying with standard specifications. (Payment for centering shall be given after the concrete is laid)

586

-

-

... More
Supplying and erecting of 3 HP submersible Pump of approved make confirming to IS 8034. The quality and standard of the product should be got approved by the departmental officers before use on work. Necessary warranty card should be got approved before erection of submergible pump with all accessorites

1

-

-

... More
28. Provision of intercom with phone: To be provided by lift contractor at ground floor attender room 29. Lift License: Preparation of Drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor.

-

-

-

... More
9. 1 set Low volage HRC fuse for the short circuit protection of the main supply

-

-

-

... More
Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection of 6 sq.mm copper wire and making good of the concealed portion with suitable colour

360

-

-

... More
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End

2

-

-

... More
Supplying and fixing in position white glazed earthen ware Oriya Type Indian water closet of size 580mm x 440mm of approved quality with ’p’ or ‘s’ trap with embedding the closet with trap to shape in position with brick jelly concrete 1: 2:5 (One lime and two Crushed stone sand (M-Sand and five brick jelly) using 40mm broken brick jelly and finishing the top to required slope including M-Sand cushion all round the water closet and fixing with necessary teak wood plug, clamps and screws to the portion coming on wall and floor including giving necessary connection the PVC pipe by dismantling masonry floor RCC work and redoing the same to the Original condition with out any leakage with necessary cement plastering 1:3 (One cement, and three M-Sand) 20mm thick complying with standard specification. (water closet with other accessories should be got approved by the Executive Engineer before use on work)

6

-

-

... More
1. AC Ammeter and selector switch

-

-

-

... More
Supplying and filling ISS metal of 20 mm size in dispersion trench including stacking for pre measurements around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc.,complete.

2

-

-

... More
Supply and providing cable end termination of 3 1/2 x 240 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.

6

-

-

... More
Supplying and fixing in position best variety and approved quality heavy type Stainless Steel 15mm diameter Heavy Duty Long Body Tap including cost for cutting and threading of the galvanized iron pipes cotton thread shellac etc., complete complying with standard specification.

27

-

-

... More
Supplying and fixing in position best quality approved make White Porcelin Sink of size of 600 x 450 x 200mm including cost of 32mm dia CP waste coupling, 32mm diaB’ Class GI Waste Water Pipe,15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Executive Engineer before use on works]

8

-

-

... More
Brick / Stone Masonry in lime mortar walls under 3m high

179.17

-

-

... More
Supply and clamping of 3-1/2 x 70 sq.mm. aluminium PVC LTUG armoured cable on post or on wall with MS clamps.

90

-

-

... More
Supplying and fixing in position best variety and approved quality heavy type chromium platted (brass) 15mm diameter screw down tap including cost for cutting and threading of the galvanized iron pipes cotton thread shellac etc., complete complying with standard specification.

82

-

-

... More
Dadooing walls with Granite tiles of Synthetic Grey, Paradise and Similar varieties of suitable sizes in Cement Mortar 1:2 (One Cement and Two Crushed Stone sand (M-sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.

135

-

-

... More
25.Rectangular copper bus bars (1No for each phase, neutral and earthing terminals) of adequate capacity duly colour coded with head shrinkable PVC sleeves.

-

-

-

... More
50 mm dia CPVC Pipe

41

-

-

... More
In Third floor

161

-

-

... More
22.1No signal lamp for indicating battery

-

-

-

... More
32 mm dia CPVC Pipe

485

-

-

... More
Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb

46

-

-

... More
19. 1 no signal lamp for indicating load on set

-

-

-

... More
Supplying, laying and jointing CPVC (chlorinated Poly vinyl chloride) pipe( Higher pressure rating with higher pipe thickness) Standard Dimension Ratio- 11)of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using SOLVENT OF 118ML (but excluding cost of such specials) and fixing making goog the dismantled portion to original condition with necessary brick work/cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. Above Ground Level - External

-

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete

671

-

-

... More
Supplying and fixing mild steel iron grill for windows ventilators and grill gate MS ladder etc., including one coat of red oxide primer using M.S.angle of size 40x40x6mm and grill using 20x6mm MS flat and necessary hold fast with M.S.angle of size of 40x40x6mm-230mm long spliced at end is to be provided appropriate places for fixing the grill etc complete complying with standard specification. The type design for the grills, gate etc., should be got approved by the departmental officers before execution.

9281

-

-

... More
Supply of 6" (160mm) dia PVC Plain casing pipes (10 Kg/cm2) of best Quality with ISI mark including tranportation to work site etc., complete complying with standard specification and as directed by the departmental officers.

24

-

-

... More
Providing suitable concrete foundation with plain cement concrete 1:2:4 using 20mm jelly for wearing coat including laying, compacting, finishing and curing etc., complete as per standard specifications and as directed by the departmental officers for 160kVA Genset to 50 Bedded CCB in Kovilpatti GH.

5.9

-

-

... More
75 mm Dia PVC Elbow with Door

15

-

-

... More
Single leaf

8.4

-

-

... More
75mm dia PVC Pipe

87

-

-

... More
Supply and clamping of 3-1/2 x 35 sq.mm. aluminium PVC LTUG armoured cable on post or on wall with MS clamps.

110

-

-

... More
Manufacturing, supplying and fixing in positon of Terra cotta Jally of 5cm thick in cement concrete 1:2:4 using 20mm machine crushed stone jelly (excluding cost of reinforcement steel) including cost of mould, finishing, curing, lifting, fixing in position etc., complete complying with standard specification and as directed by the departmental officers

285

-

-

... More
In Second Floor

20

-

-

... More
section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete.

-

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End

74

-

-

... More
Supplying and fixing in position best Indian make white glazed earthenware wash hand basin of size 550mm x 400mm without Pedestal with necessary cast iron brackets 15mm dia chromium plated pillar tap 32mm dia ‘B’ class GI waste pipe 32mm chromium plated brass waste coupling with rubber plug and chain 15mm dia Nylon connection etc., complete including fixing the wash hand basin in position including cost of teakwood plugs, screws rubber washers, white lead and giving water supply connection, testing for leakage etc., complete complying with standard specification. (The wash hand basin without pedestals should be got approved before use on works.)

42

-

-

... More
Drilling of 150mm diameter borewell anywhere in Tamilnadu including transporation from one place to another place with in Tamilnadu in hard rock areas at the site shown by the TWAD officers

-

-

-

... More
15. 1 no Push button "Start"

-

-

-

... More
25 mm dia CPVC Elbow

20

-

-

... More
Supply and fixing of Twin box type 4' 20W LED fitting with CRCA body complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting with 2 nos of 20 W LED tubes. (Higher End)

5

-

-

... More
50 litres Capacity

5

-

-

... More
Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc

245

-

-

... More
I) ACOUSTIC ENCLOSURE: The Acoustic enclosure, Self standing weather proof Acoustic canopy conforming CPCB IV+ norms floor mounting type with modular construction with the provision to assemble and dismantle easily and designed to suit all weather condtions and compliance to IS standards.

-

-

-

... More
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone M-sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers

-

-

-

... More
Supply and Fixing of Tap Boxes 250A 25KA FP MCCB with suitable enclosure and Acessories and earth connection complete

6

-

-

... More
Supplying and fixing of SS False Ceiling

112

-

-

... More
13. Lift well existing: 1870mm (width) x 1400mm (depth) 14. Lift pit depth available : 750 mm 15. Car size (Clear inside): 1000mm width x 1000mm depth 16. Car clear opening: 1000mm width x 1200mm height 17. Power supply: 400/440 3 phase, 50 Cycles/sec A.C. supply for power and 230 V, 50 HZ, single phase, supply for lighting. 18. Car fittings: Indirect and LED light 19. Lift well: R.C.C. construction with brick masonry.(Existing)

-

-

-

... More
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed Stone sand (M-Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.

918

-

-

... More
Electrical works:Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End )

619

-

-

... More
Supply and Fixing of Tap Boxes 125A 25KA FP MCCB with suitable enclosure and Acessories and earth connection complete

8

-

-

... More
Supply of 4.00 sqmm PVC insulated and sheathed three core flat type Copper Cable conforming to IS 694/1990 for submersible motor having good quality with ISI mark etc., complete complying with standard specification.

115

-

-

... More
Supplying and fixing Solid core Particle board flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides commercial ply 3mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200 x 12 mm aluminium tower bolt 2 nos. 150x12 mm aluminium tower bolts 1no. 250 x 16 mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers.

-

-

-

... More
Supply, fabrication, erection and comissioning of 200A capacity dust and vermin proof cubical panel board of suitable size made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interior switch with bus bar chamber complete with

6

-

-

... More
3. 3Nos current transformer with suitable ratio

-

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil)(Higher End) (For Street Light Point)

15

-

-

... More
40 mm dia CPVC Pipe

26

-

-

... More
In Foundation and basement

459

-

-

... More
Supply, Testing Commissioning and Handing over of 160 KVA Diesel Generator set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications of 0.8 P.F. Three phase 415V/ 420 Volts, 50Hz, 1500 RPM CPCB Approved capacity developing 200 HP with acoustic enclosure water cooled clock wise rotating feed pump with 128KW / 160KVA operating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and vibration fitting and accessories and AMF panel as detailed below including transporting & unloading charges.

1

-

-

... More
27.Hooter/Audio alarm for indicating set fails to start and for DG O/L.

-

-

-

... More
25 mm dia CPVC Bend

35

-

-

... More
Supply and clamping of 2 runs of 3 1/2 x 240 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.

124

-

-

... More
Supply and fixing of Exhaust Pipe with Silencer for Genset.

5

-

-

... More
Supply, installation, testing and commissioning of Laminar Flow arrangements with HEPA Filters, Frames, etc. 8 ft X 6 ft for OT Ceiling Suspended provides ultra clean sterile CLASS 100 clean air and designed as per CLASS 5 OF ISO 14644-1 standards with air plenum at Aluminium powder coated 1mm thick casing with Aluminium pleat HEPA filters & 0.3 micron 99.97% efficiency and SS 304 perforated grill with 13 mm thickness XLP Insulation with Modular Housing, Frame: Aluminium, Flange type, Filter Media: Micro glass fibre, Sealant : Plolyurethane with Air flow as per standards suitable for 8.5 TR.

2

-

-

... More
Supply and providing of 0.5sqmm 4 core flexible signal cable

100

-

-

... More
25 mm thickness

256

-

-

... More
supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.

100

-

-

... More
Supply and fixing of brass cable gland for 3 1/2 x 185 sq.mm aluminium PVC LTUG armoured cable with earth connection.

12

-

-

... More
In Ground Floor

92

-

-

... More
Supply and providing cable end termination of 3-1/2 x 35 sq.mm. aluminium PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.

6

-

-

... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). Above Ground Level

-

-

-

... More
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand (P-sand)) 10mm thick mixed with bonding agent Cebex112, Zydex-Zycrete 2x or other equivalent compound conforming to BIS at 200 ml of one cement bag (50kg) for increased workability and air entrainment used finished including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complete complying with standard specification and as directed by the departmental officers

8935

-

-

... More
30.1No Earth fault relay

-

-

-

... More
Brick work in Cement Mortar 1:6 (one cement and Six crushed stone sand (M-sand) using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" for including pointing with same mortar, levelling and curing, etc., complete complying with standard specifiction

-

-

-

... More
31.Isolator to isolate the neutral

-

-

-

... More
5. Speed : 1.0 m/s 6. Type of Drive: Specific variable voltage variable frequency V3F drive with enhanced ride comfort and near Zero leveling functions.

-

-

-

... More
The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.

-

-

-

... More
F) Providing drainage piping from the evaporator and cabinet to lead drain water just outside the cabinet room. G) Including Packing and Forwarding Charges.

-

-

-

... More
Erection of acoustic enclosure suitable for 160KVA Diesel generator complete with all accessories as above and suitable supports etc. as approved by competent authority to suit updated CPCB norms.

-

-

-

... More
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.

20

-

-

... More
Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers

1

-

-

... More
In Second Floor

84

-

-

... More
Supplying, fabricating and fixing in position of Aluminium Natural Colour Mat finilsh Fixed Glazing the glass used shall be of 5 mm thickness. The Aluminium Section are to be anodised under electrically controlled condition as per IS 1868/1962 for an anodic film thickness of 15 microns. All the materials should be got approved by got approved by the Executive Engineer before execution of works.

4

-

-

... More
Supply and fixing of 32A, 10kA FP MCB in sheet enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End).

15

-

-

... More
Design, Engineering supply, fabrication, erection, testing, commissioning and handing over of 240kg Dumb waiter lift MRL Speed 1m/s with M.S. Panels, microprocessor based controller, VVVF drive as per IS specifications

1

-

-

... More
31. Sill angles and facia plates: to be provided by lift contractor 32. Steel for lift machinery: to be provided by lift contractor 33. Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by the lift contractor during the guarantee period of one year. 34. Automatic Rescue Device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, inverter, under voltage protection system etc., complete with all accessories.

-

-

-

... More
40 mm dia CPVC Union

6

-

-

... More
110 mm Dia PVC Y with Double door

15

-

-

... More
Supplying, laying and jointing CPVC (chlorinated Poly vinyl chloride) pipe ( Higher pressure rating with higher pipe thickness) Standard Dimension Ratio- 11)of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using SOLVENT OF 118ML (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. Below Ground Level - External

-

-

-

... More
4) Individual doors for each body with chrome plated hinges and locks. 5) All panels to be joined together by means of tongue and groove and locked together by means of cam locks on each side to ensure air tightness, foamed in PVC bubble gasket in all panels.

-

-

-

... More
Paving the floor with best quality Double Charged Vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three Crushed stone sand (M-Sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

2603

-

-

... More
Supplying and filling the basement with conveyed earth with a lead of 0.00 to 5.00 kmmr in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

245

-

-

... More
Supply and fixing of 3nos.6A two module socket, 1no. 6/16A two module socket, 3nos. 6A one module switch, 1no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End

199

-

-

... More
Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum- Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.

-

-

-

... More
75 mm thick

8

-

-

... More
Supply and run of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil with necessary masonary and excavation work .

120

-

-

... More
14. 1 set selector switch auto/ manual

-

-

-

... More
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work.

37

-

-

... More
Supply and fixing of Refrigirant piping out of hard drawn copper pipe set of 28.60 mm size

150

-

-

... More
Providing Anti-Termite Treatment to soil adjacent and under building foundation, plinth periphery of the building by application of chemicals of IS 6313 part I to IV in stages to suit the progress of work consist as per the detailed specification as below (Measurements taken for the plinth area for the purpose of payment) including breaking of termit mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges transport and storing etc., complete (The chemical should be got approved by the Executive Engineer before use on works)

805

-

-

... More
Brick work in Cement Mortar 1:3 (one cement and Three crushed stone sand (M-sand) using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" for including pointing with same mortar, levelling and curing, etc., complete complying with standard specifiction

-

-

-

... More
Providing granolithic floor finish of the required thickness with plain cement concrete 1:2:4 (One Cement, Two crushed stone sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)

-

-

-

... More
Supplying and fixing of 3 Phase Panel Board including labour charges etc., complete.

1

-

-

... More
25 mm dia CPVC Pipe

398

-

-

... More
Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100A 4P MCB as incoming and 2nos 63A TP MCB & 6nos. 32A TP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. Higher End

7

-

-

... More
1. Output Voltage Range : 208V/220V/230V/240V AC 2. Voltage THD (Linear Load) : ≤2% 3. Voltage THD (Non-Linear Load) : ≤4% 4. Current THD : 10% 5. Overload : 110%, 30s turn to Bypass mode; 150% instant turn to Bypass mode 6. Short Circuit protection : 5 cycles turn off inverter, no transfer to Bypass, provide Alarm (AC mode) ; 5cycles turn off inverter, provide Alarm (Battery mode), Input fuse blown or breaker action 7. Waveform : Pure sinewave

-

-

-

... More
Supply and Fixing of MS Supports for with necessary accessories for fixing Rising Main.

45

-

-

... More
Supplying and filling with M-sand in layers of not more than 15 cm thick without consolidation etc. complete complying with standard specification and as directed by the departmental officers.

2

-

-

... More
20 mm dia CPVC Pipe

422

-

-

... More
Supplying and fixing 32 mm dia HDPE pipe for sub-mersible pump in Bore well (class-5 1 MPa or 10 Kg / cm2 pressure) of best approved quality including welding wherever necessary etc., complete as directed by the Executive Engineer. The pipe should be got approved by the Executive Engineer before use on works.

115

-

-

... More
Supply and filling of R410A Refrigerant Gas

150

-

-

... More
(E) AMF CONTROL PANEL: The AMF control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connection incoming and outgoing leads having been made on the control panel.

-

-

-

... More
Supply and fixing of extruded Aluminium powder Coated, supply and return Air Grilles / Diffusers with volume control dampers.

50

-

-

... More
25 mm dia G.M. Gate Valve

20

-

-

... More
(B) 12/24 Volt Electronic starting Equipment: Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cms length

-

-

-

... More
In Foundation and Basement

13

-

-

... More
6. 1 No power factor meter

-

-

-

... More
Brick / Stone Masonry in cement mortar walls under 3m high

235.23

-

-

... More
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the departmental officers.

7086

-

-

... More
D) Supply, fabrication and fixing of 4 numbers of telescopic stainless-steel trays with Rollers and bush bearing to keep body on the telescopic structure inside the cabinet. E) Providing 2" thick raised concrete platform of suitable size to keep the 4 body mortuary cabinets.

-

-

-

... More
Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 22 Gauge thickness.

220

-

-

... More
2 .Volmeter and selector switch

-

-

-

... More
5. KWH meter

-

-

-

... More
Supply and fixing of MS stand for fixing outdoor unit.

6

-

-

... More
Supply and fixing of brass cable gland for 3 1/2 x 240 sqmm PVC aluminium armoured LTUG cable with earth connection.

6

-

-

... More
Supply and run of 1 of No.8 SWG GI wire for earth connection

90

-

-

... More
Supply and fixing of louvers shutters arrangements for 300mm (12”) sweep (light duty) AC Exhaust fan.

26

-

-

... More
7. No. of floors: (Ground + 5 floors) 8. Total Travel : 18 mtrs. 9. Leveling Accuracy: High level accuracy with smooth & jerk free stopping 10. No. of landing entrance: 6 Nos (one in front only) 11. No. of car entrance: one in front only 12. Landing entrance door: collapsible gate MS painted - black with landing door frame

-

-

-

... More
After the installation of DG set on its foundation, the DG set should be tested and commissioned with first charging of lubrication oil to its level, first charging of battery and run the set for eight hours on full load test complete. The Genset engine and alternator make should be approved by department officials before used on work.

-

-

-

... More
Supply and fixing of brass cable gland for 3 1/2 x 70 sq.mm aluminium PVC LTUG armoured cable with earth connection.

12

-

-

... More
In Foundation and basement

16

-

-

... More
Supplying and fixing of suitable PVC End cap for 6" dia bore well of best quality with ISI mark (The PVC End Cap should be got approved by departmental officers before use on works 160mm dia

1

-

-

... More
Supply and providing of 1.5sqmm copper flexible cable

100

-

-

... More
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Modular Light point (Higher End)

24

-

-

... More
with power drill wherever necessary and redoing the damaged portion to the original condition afterfixing etc. complete. All the Alu. sections are to be anodised with matt finish under electically contolled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge.

-

-

-

... More
Supply and fixing of 100A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only.

2

-

-

... More
2) Insulation with 80mm thick pre fabricated modular PUF panel with cyclopentane blowing agent made of CFC and HCFC free high grade polyurethane with 40 Kg/cu.mt. 3) Panel finish with 0.55mm thick stainless steel 304 grade

-

-

-

... More
Supplying and fixing in position best approved quality bevelled edge mirror of size 60x45cm, 5.5mm thick mirror shelf type with necessary PVC backing rubber buttons. Brass chromium platted screws, plugs etc., complete complying with standard specification. (The mirror should be got approved by Executive Engineer before use on works).

20

-

-

... More
21.1no signal lamp for indicating set running

-

-

-

... More
30. Other standard features: Voltage stabilizer for control units, Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electromagnetic brake with compression springs car safety gears buffer, motor over load protection devices final limits switch, main suspension ropes counter weights lifting hoist for mounting the machineries.

-

-

-

... More
11. 1 set Three pole bimetal release for over load protection of alternator

-

-

-

... More
In Third floor

8

-

-

... More
10. 1 set Alternator contactor with auxiliary netural contactor

-

-

-

... More
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls

-

-

-

... More
In Second floor

198

-

-

... More
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour

5340

-

-

... More
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in hard rock requiring blasting inclusive of shoring, strutting, bailing out water wherever necessary and depositing the excavated earth with an initial lead of 10 mts,, and initial lift of 2 mts., within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.

163

-

-

... More
3. Insulating the suction pipe with expanded polyethelene foam 5mm tubing 4. Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being formed with in the indoor unit. 5. Leakage testing the entire system. 6. Charging refrigerant gas in the unit. 7.Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3 meters of the location of indoor unit.

-

-

-

... More
Supplying and fixing in position white glazed European Water Closet of best quality and approved make with 100mm "P" or "S" trap connecting with PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC flushing tank without CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fitting. such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide

33

-

-

... More
1. 200 A TPN switch disconnector fuse units interior only with HRC fuses double break-1No 2. 100 A TPN switch disconnector fuse units interior only with HRC fuses double break-4 Nos 3. 63A TPN switch disconnector fuse units interior only with HRC fuses double break- 3Nos.

-

-

-

... More
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with MS switch Box and 5A FT switch with painting of suitable colour continuous earth wire connection of 1.5 sq.mm copper wire for light point / fan point (for electronic regulator). (For Lift shaft)

21

-

-

... More
Supply and frxing of brass cable gland for 3-1/2 x 50 sq.mm. aluminium PVC armoured LTUG cable with earth connection.

4

-

-

... More
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance using 20mm with IS:456-2000, and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kgm3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 k9. of 20mm machine crushed stone jelly and with about (3'3 cu'm') 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu'm') 7670 kg' of M-sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
Supplying and fixing fine polished cuddapah slab of 20 / 30mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.

83

-

-

... More
Supply and fixing of 80 watts IP66 protected High Efficiency Round HighBay luminaire (Wipro Radial UNO/Eq) of efficacy 110 lumens/watt with suitable for mounting on ceiling with PVC unsheathed copper leads from terminals to the fitting.

2

-

-

... More
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss.

342

-

-

... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works)The rate for earth work excavation,sand filling and refilling charges etc. will be measured and paid separately in the cases where the pipe lines are proposed to laid Below Ground Level

-

-

-

... More
Supply and fixing of Duct Mouth Dampers

8

-

-

... More
Supply and fixing of single box type 4' 20W LED fitting with CRCA body complete with TW round blocks on wall or ceiling with 20W LED tube with PVC unsheathed FRLS Copper leads from terminals to the fitting. (Higher End)

346

-

-

... More
Floor finish & dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabs

194.74

-

-

... More
Dismantling RCC by manual / by using deploying machineries

82.03

-

-

... More
In Third floor

203

-

-

... More
160mm dia PVC Pipe

85

-

-

... More
40. Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period not less than one year. 41. Site testing in accordance with IS 14665 as amended should be carried out at the time of handing over. Necessary spares and tools required for the maintenance for a period of one year 42. Supply of operation and maintenance manual with Necessary tools for Operation. The list of tools required should be detailed by the contractor in a separate sheet duly signed by contactor. (Johnson/KONE/ OTIS) (G+5)

-

-

-

... More
Supply and fixing of 4 way 7 segment triple pole neutral MCB distribution board in sheet steel enclosure double door type with metal door with IP 42 protection with 40A 4 pole MCB as incoming and 3Nos 40A DP RCCB with 30mA sensitivity as sub incomer and 12Nos. 6 A to32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. (Higher End)

6

-

-

... More
110mm dia PVC Pipe

101

-

-

... More
50 mm thick

37

-

-

... More
prefilters with 3ply HDPE 50mm thick filters having an efficiency of 90% 10 mic, 6row /12FPI deep DX copper cooling coil with copper header and aluminium fins ,GI mist arrestor ,condensate coil trough with SS-304-20G insulated with 9mm closed cell elastomeric foam, guard for inspection door ,out let damper of aerofoil blades &PVC gears ,and flexible fire retardant canvass complete with galvanized hardware.

-

-

-

... More
35. Provision of intercom with phone: To be provided by lift contractor 3 points EPABX system at three places vide 1) inside the car 2) Head room 3) at ground floor attender room 36. Lift License: Preparation of Drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. 37. Floor annunciator with music, included

-

-

-

... More
18.1 No signal lamp for indicating load on mains

-

-

-

... More
Supply and providing thermal insulation of 9 mm thick vidoflex with Aluminium Foil.

60

-

-

... More
Supply, fabrication and fixing of MS channel for mounting the Airconditioning Indoor Unit.

8

-

-

... More
20.1no signal lamp for indicating set fails to start

-

-

-

... More
(A) Supply, fabrication and erection of one number PUF insulated cabinet type mortuary chamber to hold 4 bodies in 2-tier arrangement as per the following specification and provisions.

-

-

-

... More
Supply and Run of 4 of 16 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 sq.mm copper wire and making good of the concealed portion.

300

-

-

... More
Supply and clamping of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used as down conductor system with necessary Conductor Holder,glue, connectors, joints and expansion piece etc as per IEC 62561-2 recommendation and site condition

400

-

-

... More
Earth work Excavation for foundation in all soils and sub soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring, strutting and bailing-out of water wherever necessary, re-filling the sides of foundation with excavated earth in layers of 15cm thick well rammed and compacted, depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 meters and lift of 2 meters and clearing and levelling the site etc., complete with standard specifications.

1124

-

-

... More
13.1 set DC control relays incorporating engine start/ stop and failure to start / lockout

-

-

-

... More
Supplying and fixing best approved best quality Stainless steel Health Faucet with Stop coak of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The Health Faucet should be got approved by Executive Engineer before use on works).

33

-

-

... More
Supply, installation, testing, commissioning and handing over of air-cooled self contained ductable ac units with the following components. a) 5.5 TR capacity ceiling suspended Ductable Air Conditioner high tech, low height, low noise level indoor unit with fin and tube type cooling coil, Detachable type drier provided in refrigerant cicuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil, with required valves, directly coupled blower, Thermostatic expansion valve lift and pull type aluminum framed durable, washable air filter, Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit, common operating conditions of 45 degree F suction temperature, Auto reset type HP/LP safety cut to improve reliability of compressor.

6

-

-

... More
Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug)

41

-

-

... More
50 mm dia CPVC Elbow

10

-

-

... More
Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.

4

-

-

... More
Supply and fixing of 65mm (2½") G.I. pipe (Class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting & masonry work for fixing the post (for cable tray)

10

-

-

... More
Supply and clamping of 3 1/2 x 240 sq.mm PVC LTUG aluminium armoured cable on post or on wall with MS Clamps.

124

-

-

... More
17. 1 no Push button "Reset"

-

-

-

... More
16. 1 no Push button "Stop"

-

-

-

... More
Supplying and fixing of vinyl flooring 2mm thick

112

-

-

... More
Supply, erection, testing and commissioning of 2.0 TR (6000 K.cal/hr) ABS Plastic Split type Inverter Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with inverter compressor operating on refrigerant of non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with 5 star rating as per BEE specification and capable of performing the functions

6

-

-

... More
Supplying and erecting centering for sides and soffits including supports and strutting upto 3.29m high for plain surfaces such as RCC slab, beams, TEE or Ell beams, Lintels staircase beams etc., with all cross bracings using mild steel sheets of size 90cm x 60cm of B.G.10 stiffened with welded mild steel angles of size 25 mm x 25 mm x 3 mm boarding laid over silver oak (or) country wood joists of size 10 cm x 6.5 cm spaced at about 90 cm centre to centre and supported by casuarina props of 10cm to 13 cm dia spaced at 75 cm centre to centre at suitable interval. etc., complete complying with standard specifications. (Payment for centering shall be given after the concrete is laid)

-

-

-

... More
Supplying and fixing in position best approved quality chromium plated soap tray size 150 x 100mm including cost of teakwood plugs, chromium plated brass screws etc., complete complying with standard specification. (The soap tray should be got approved by Executive Engineer before use on works).

42

-

-

... More
7. No. of floors: (Ground + 5 floors) 8. Total Travel : 18 mtrs. 9. Leveling Accuracy: High level accuracy with smooth & jerk free stopping 10. Construction of Car: Car Panel with High quality SS 304 grade car Neat hairline finish, S.S 304 grade hand rail, Perspex false ceiling, stretcher impact protection. 11. Position of machine: Directly above the lift well. 12. No. of landing entrance: 6 Nos (one in front only) 13. No. of car entrance: one in front only 14. Car entrance door: power operated V3F drive side opening sliding SS 304 stainless steel hair line finish. 15. Landing entrance door: power operated V3F sliding, opening 18SWG stainless steel 304 grade hair line finish with provision for emergency key

-

-

-

... More
1"x1/4" tinned cu. Flat for 3 phases & neutral and earth connections with bus bar insulators complete with the following tinned Cu flat should be used between busbar and switches : 1"x1/4" tinned cu. Flat for interconnection of 1 no 200A incoming switch to bus bar, 1"x1/8" tinned cu. Flat for interconnection of 4nos 100A switch to bus bar, No.8 SWG rigid copper for 3 Nos 63A outgoing Switch to the bus bar and including supply and fixing of multifunction meter (VAF) with suitable CT –coil, selector switches & indication lamps with HRC fueses connections complete etc. The panel should be fabricated as per CEIG specification.The housing accommodate 8 Nos 3 phase switches and supply and fixing of the following switches.

-

-

-

... More
32mm dia CPVC Elbow

20

-

-

... More
Supply and Installation of 250A FP MCCB with suitable enclosure and Acessories and earth connection complete

1

-

-

... More
F.FUEL TANK 400 litres fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for cleaning or any maintenance. G. Exhaust Gas Recirculation system arrangements as per CPCB IV+ norms as amended

-

-

-

... More
In First Floor

86

-

-

... More
Supply and fixing of 1" PVC water drain pipe line

60

-

-

... More
25 mm dia CPVC Tee

20

-

-

... More
In Foundation and Basement

158

-

-

... More
In Fourth floor

146

-

-

... More
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

417

-

-

... More
In Fifth floor

194

-

-

... More
32mm dia CPVC Tee

30

-

-

... More
32mm dia CPVC Union

25

-

-

... More
In Fifth floor

114

-

-

... More
Earthing as per P.W.D standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work.

20

-

-

... More
26.1No mains voltage monitor

-

-

-

... More
1) External cabinet dimensions of 2114mm(w) x 2404mm(D) x 1785mm(H)

-

-

-

... More
Supply and clamping of 3-1/2 x 185 sq.mm. aluminium PVC LTUG armoured cable on post or on wall with MS clamps.

90

-

-

... More
Supplying, fabricating and fixing in position factory made Stainless Steel Flush Door Shutter 35mm thick using SS 304 Grade 1.6 mm thick, Stainless Sheets on both sides (Equivalent to IS 6911-04 Cr. 19, Ni 9) minimum 8-8.5% nickel and 18% chromium sourced from original stainless steel manufacturer with view panel size 30mm x 45mm made up of 6mm thick clear toughened glass fitted with double side adhesive tape and finished with dowconing silicon sealant, floor spring for each shutter, consealed tower bolt, suitable stainless steel locking arrangement and other necessary furniture fittings of approved quality. The vertical styles and other frame members and cross stiffeners shall be of same quality stainless steel box section of suitable size and thickness with proper core material as prescribed by the Departmental Officers

6.5

-

-

... More
31. Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period not less than one year. 32. Site testing in accordance with IS 14665 as amended should be carried out at the time of handing over. Necessary spares and tools required for the maintenance for a period of one year 33. Supply of operation and maintenance manual with Necessary tools for Operation. The list of tools required should be detailed by the contractor in a separate sheet duly signed by contactor. (Johnson/KONE/ OTIS) (G+5)

-

-

-

... More
20. External extended push button with / without attendant 21. Indication: UP/Down digital direction and position indicator for all landing 22. Overload warning indicator and Fireman’s switch to be provided 23. Minor builders work: to be provided by lift contractor. 24. Scaffolding: to be provided by lift contractor

-

-

-

... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.

3315

-

-

... More
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End

24

-

-

... More
Double leaf

10.8

-

-

... More
Supplying of CPVC (Ashirvad /Astral or equilvalent) Specials of approved quality and good variety conforming to ASTM D-2846standard etc., complete complying with standard specification. (The CPVC specials should be got approved by the Executive Engineer concerned before use on works.)

-

-

-

... More
In Ground floor

197

-

-

... More
A separate chamber on top of one side should be provided with multi function meter to display Line & Phase Voltage, Phase Current, Power Factor and Frequency with one set of LED pilot lamp, fuse holder with suitable HRC fuse for each phase with suitable CT coil arrangements. The panel should be fabricated as per relevant CEIG specification for accommodation of 6Nos 3 phase switches and supply & fixing of the following switches.

-

-

-

... More
Supply and fixing of 24W LED square type Surface mounting fitting (Havells Integra Nxt DL / Eq) with Aluminium (99% Purity) Sink, available in Sqaure shape. PC diffuser in white powder coated finish with built in electronic low THD (10%) LED driver 6500K CCT; CRI ≥ 80 with 1.5 sqmm PVC unsheathead FRLS copper wire from terminals to the fitting and necessary connection complete.

8

-

-

... More
7. Battery charging set comprising of the following for charging the battery from mains

-

-

-

... More
25. Sill angles and facia plates: to be provided by lift contractor 26. Steel for lift machinery: to be provided by lift contractor 27. Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by the lift contractor during the guarantee period of one year.

-

-

-

... More
D)ALTERNATOR: 160KVA/128KW Capacity of brushless alternator, AC 3 phase, 50Hz, 415/420V, 0.8 PF, 1500 RPM under NTP conditions, conforming to CPCB IV+ Norms.

-

-

-

... More
Dadooing walls with colour designed digital printed ceramic tiles of size 300mm x 450mm x 8mm best approved quality tiles set in Cement Mortar 1:2 (One Cement and Two Crushed Stone sand (M-sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification (Non branded) and as directed by the departmental officers.

3985

-

-

... More
75mm dia PVC Pipe

188

-

-

... More
Supply and Installation of Battery operated LCD type Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.

1

-

-

... More
In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylem sheet sepearator, and properly earthed by tinned solid copper flat as per CEIG specifications. The earth bus with two runs of 1"x1/4" tinned copper flat must be run all round the panel

-

-

-

... More
In Sixth floor

52

-

-

... More
In First Floor

8

-

-

... More
Supplying and fixing of Nylon rope for bore well and as directed by the departmental officers.

120

-

-

... More
Stage-1: Spraying anti-termite chemical solution for the foundation before laying concrete in bottom and sides of foundation.

-

-

-

... More
Supply and fixing of 32A, 10kA Double pole MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End).

5

-

-

... More
Supply and providing cable end termination of 3 1/2 x 70 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection comple.

12

-

-

... More
Manufacturing, supplying and fixing in position plain cement concrete precast pavement slab of size 450mm x 450mm of 50mm thick in Cement Concrete 1:2:4 (One cement, Two crushed stone sand (M-sand) and Four hard broken stone jelly) using 20mm HBG stone jelly including cost of moulding charges, casting of slab, finishing, curing, fixing and pointing the slab with CM 1:3 (One Cement and Three crushed stone Sand (M-sand)) to full depth of slab etc., complete complying with standard specification and as directed by the departmental officers.

93

-

-

... More
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three Crushed stone sand (M-Sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with matching colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speciification.

422

-

-

... More
In Fifth floor

18

-

-

... More
25 mm dia CPVC Hex Nipple

70

-

-

... More
Supply, Fabrication and Erection of fabricated ducting made up of GI sheets of 24 Gauge thickness.

195

-

-

... More
Supply, fabrication, erection and comissioning of 125A capacity dust and vermin proof cubical panel board of suitable size made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interior switch with bus bar chamber complete

6

-

-

... More
9) Pilot light to alert the personnel on the outside of the cabinet. 10) Toggle switches to operate the vapour proof light and pilot light mounted on the outside of cabinet with stainless steel cover plate protection.

-

-

-

... More
Supply and providing cable end termination of 3 1/2 x 185sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection comple.

12

-

-

... More
Brick work in Cement Mortar 1:5(one cement and five crushed stone sand (M-sand) using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" for including pointing with same mortar, levelling and curing, etc., complete complying with standard specifiction

-

-

-

... More
In Fifth floor

208

-

-

... More
Providing and Filling the tile joint with epoxy grout with following specification: Surface preparation including cleaning the joint to be free from dust and loose particles. Providing masking tape on either side of the tile joint edges and providing sealing the tile gap with epoxy tile joint grout and finishing neatly and as directed by the departmental officers. The rate inclusive of cost of materials and labour, etc. complete.

168

-

-

... More
8. 1 set Air break contactor with auxiliary netural contactor for main supply

-

-

-

... More
Supplying and fixing in position best quality chromium plated Towel rail of 60cm length and 20mm dia with C.P brackets of same material including fixing with necessary T.W plugs, C.P screws and dismantling masonry and redoing the same etc., complete complying with standard specification. (The Towel rail should be got approved by Executive Engineer before use on works).

42

-

-

... More
Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed portion.

510

-

-

... More
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection

150

-

-

... More
Stage-4: Spraying anti-termite chemical solution alround building outside by making holes through bar before laying plinth protection and the holes to be closed after the treatment.

-

-

-

... More
Supply of Maintenance Free Copper bonded Earth rod of 3000mm length having the dia of 17.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2.

8

-

-

... More
In First floor.

197

-

-

... More
H) Clear height of 1m above the cabinet recommended for better air circulation.

-

-

-

... More
160mm dia PVC Pipe

15

-

-

... More
H.BASE FRAME: Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generaor set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame with proper alignment.

-

-

-

... More
1. 125A TPN switch disconnector fuse units interior only with HRC fuses double break - 1No 2. 63A TPN switch disconnector fuse units interior only with HRC fuses double break - 5Nos

-

-

-

... More
Plastering with Cement Mortar 1:3 [One Cement and Three Plastering sand (P-sand)] 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finishing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.

82

-

-

... More
SS Elbow Action Tap of size 15mm

8

-

-

... More
Dismantling Plain Cement Concrete

51.8

-

-

... More
In First floor

158

-

-

... More
Supplying and filling ISS metal of 40mm size in dispersion trench including stacking for pre measurements around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc.,complete.

2

-

-

... More
Supply and fixing of 300mm width x 50mm height GI Hot dip galvanized powder coated 16SWG preforated cable tray on ceiling or wall with suitable fastereners, bolt nuts, clamps and necessary connection complete.

150

-

-

... More
32 mm dia CPVC Coupling

25

-

-

... More
In Fourth floor

215

-

-

... More
Supply and laying of 5/8" and 3/8" soft drawn copper refrigerant pipe of 0.8mm thick by flaring connection with interconnection wire between indoor & outdoor unit. (Extra beyond 3 mts/AC unit)

42

-

-

... More
Supply and Installation of 400A FP MCCB with suitable enclosure and Acessories and earth connection complete

1

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

8832

-

-

... More
primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Enginer before use on works) White glazed European water closet with 10 litre capacity PVC Flushing tank fixed on to the wall.

-

-

-

... More
Supply and fixing of 1no. 6/16A two module socket, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End

6

-

-

... More
110 mm Dia PVC Tee

10

-

-

... More
8. Transfer time : (AC mode to Battery mode - Zero) (Inverter to bypass - 4ms) 9. Efficiency : 85% to 92% 10. Noise Level : less than 50dBA @ 1meter (with fan speed control) 11. Warranty : Two years on Electronics & one year on battery. (Microtek / Numeric make / Eq), (Battery make : Exide)

-

-

-

... More
Wrought & put up framed Timbers in Roof & floor

1.06

-

-

... More
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

208

-

-

... More
Supply and fixing of 5kVA single Phase In & Single Phase out Online UPS of Microcontroller based High frequency and Double Conversion Online Technology with inbuilt isolation transformer system, LCD/ LED Display with suitable SMF battery to provide minimum 1hour backup along with Powder coated MS Rack and interlink cables with following specifications:

6

-

-

... More
Supply and Installation of 5 KVA Electronic Automatic Voltage Stabilizer with Input Voltage range of 150Volt - 285Volt and Output Voltage range 200Volts to 230 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration.

6

-

-

... More
Supply and providing Acoustic for initial portion of Ducting with 12mm thick fiber glass rigid board covered with Tissue Paper and Aluminium Perforated Sheet.

100

-

-

... More
Supplying and fixing Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.

89

-

-

... More
Cement Concrete 1:5:10 (One cement, Five crushed stone sand (M-sand) and Ten hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers).

36

-

-

... More
110 mm dia PVC Rain water pipe

402

-

-

... More
Providing and Fixing of PVC Trims (Corner beading) at the outer corner profiles of the tiles including cost of material, labour and handling etc. as directed by departmental engineers at site of work and as per standard specification.

1173

-

-

... More
Supply, fabrication and fixing of MS channel for mounting the Airconditioning Outdoor Unit.

8

-

-

... More
Providing and fixing of 1.2mm thick Lead Lining Door for X-Ray Rooms, Scanning Rooms with Mild Steel Door Frames 105mm x 57mm X 18 G and 12 G x 50mm Shutter made of GI with PWG finish and honey wool insulations with SS 101mm x 75mm x 3mm SS 304 Ball Bearings Butt Hinges, Mortice Sash Lock ML 100A, 50mm BS, 85mm centre, CL 207 : Key & Knob 70mm, 5 Pin Cylinder with Handle SS Finish (Dorma Make), Heavy Duty Door Closer, Frames fixed wih walls using Mortice Sash Lock ML 100A, 50mm BS, 85mm centre CL207: Key & Knob 70mm, 5 Pin Cylinder with Handle SS Finish (Dorma Make) all neccesary accessories and fittings as per the required and as per the approval for the Department Officer

6.3

-

-

... More
Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three Crushed stone sand (M-Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

751

-

-

... More
110 mm Dia PVC Elbow with Door

20

-

-

... More
Upto 150m below Ground level

120

-

-

... More
32 mm dia CPVC Hex Nipple

35

-

-

... More
Supplying, fabricating and fixing in position of Aluminium anodised natural colour matt finish of double leaves door with half panelled with 12mm thick bothside prelaminated partile board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section-Vertical &Top rail: 50x44.45x2.50mm @ 1.292 kg/m and Bottom rail : 100 x 44.45 x 2.50mm @ 1.974 kg /m , Lock rail : 50x44.45x2.5mm @ 1.292 kg/m,Alu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/m Alu. Handle: 100x30mm @ 0.988 kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 2 Nos., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 2Nos ., lock-1No., Door stopper with rubber bush including cost of materials, labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beam masonry

69.5

-

-

... More
In Second floor

160

-

-

... More
20 mm dia CPVC Tee

30

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End

40

-

-

... More
28.1set Timers

-

-

-

... More
b) Supply of 5.5 TR capacity ceiling suspended ductable air conditioner high tech Outdoor unit with power saving high efficiency sturdy and rugged 1 No of scroll compressor for each circuit with inbuilt internal thermal protector, internal pressure relief valve, Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shall be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners, Imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration. The fans are direct driven 3 or single phase motor with protection. Condensing temperature 130 degree F for the system operations.

-

-

-

... More
1. Location: Government Hospital - 50 Bedded Critical Care block (G+5) 2. No of Lift : 1No 3.Type of lift : Hospital Lift 4. Capacity of lift : 20 persons capacity (1360Kgs)

-

-

-

... More
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification

255

-

-

... More
Supplying and fixing of SS Wall Cladding

195

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc.complete

128

-

-

... More
Supply and providing of pipeline nitrile rubber insulation for refrigerant and drain pipe lines

100

-

-

... More
Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level.Using Hilux Board Plain Sheets (10mm thick)

355

-

-

... More
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.

68

-

-

... More
Supply and Laying of 25x6mm Aluminimum Earth Flat with necessary clamps/supports for earth connection.

100

-

-

... More
B) Supply, fabrication and erection of one number unitary type roof top mounted refrigeration system to maintain +2 deg C to +6 deg C inside the 4 body Mortuary cabinet with the following specifications: 1)capacity not less than 6000 BTU/HR 2)compressor of make Kirloskar Cope land/equivalent with condenser with

-

-

-

... More
Design, Engineering supply, fabrication, erection, testing, commissioning and handing over of 20 persons capacity Bed-cum-Passenger Gearless Lift with M/C room, Speed 1 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller, VVVF drive, Fire rated doors and ARD as per the following Technical specifications

2

-

-

1

-

-

... More
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.

234

-

-

... More
Supply and fixing of Refrigirant piping out of hard drawn copper pipe set of 15.9 mm size.

145

-

-

... More
In Fourth floor

6

-

-

... More
Supplying and fixing of Stainless steel Sink of size of 1200 x 550 x 180mm

4

-

-

... More
20 mm dia CPVC Bend

50

-

-

... More
250 litres Capacity

1

-

-

... More
Labour charges for Erection of Pump etc., complete

1

-

-

... More
J) Erection of generator set with proper alignment over the existing foundation.

-

-

-

... More
Doors and Windows including removal of frames, hinges and fastenings

131.71

-

-

... More
Cement Concrete 1:5:10 (one Cement, five Crushed stone sand (M-Sand)and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification.

86

-

-

... More
Supply, Erection, Testing, Commissioning and Handing over of 4 Body Cold Storage Mortuary with Eco Friendly panels, insulated doors, floors, copper tubes, telescopic S.S trays cabinet type Mortuary chamber as detailed below.

1

-

-

... More
6) 'L' shaped corner panel in a single piece in all four corners 7)Edge of the doors and door openings to be finished with PVC lining 8) Electronic temperature indicator cum controller, vapor proof/water proof incandescent lamp fixture with plastic coated globe.

-

-

-

... More
75 mm Dia PVC Tee

12

-

-

... More
Design, supply, installation, testing and commissioning of 8.5TR Nominal capacity DX Air-cooled Condensing unit fixed with energy efficient R410A Refrigerant scroll compressor along with grooved copper tube/aluminium fins air cooled condensor coil with anticorrosion coatings,liquid ,accumulator, low noise alumimium propeller condenser fan with Fan motor etc all suitably assembled neatly in heavy duty GSS sheet metal cabinet and duly powdercoated as per specifications. The unit to include built in safety controls like HP/LP switch power quality protector, in built thermal / temperature protection

2

-

-

... More
(A) Engine: Water cooled diesel engine suitable for Generator application conforming CPCBIV+ norms and IS standards with a shaft out put of 156BHP at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling fly wheel, air cleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc.(Kirloskar Green / Cummins)

-

-

-

... More
Supply and run of 1.5 sqmm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in existing PVC concealed pipe

1000

-

-

... More
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall.

26

-

-

... More
32 mm dia CPVC Pipe

39

-

-

... More
Single leaf

84.1

-

-

... More
Supplying, fabricating and placing in position Mild steel / Ribbed Tor steel reinforcement grills for all RCC works as per the design given including cost of steel and G.I black binding wire in all floors etc., complete complying with standard specification. (The contractor will have to make his own arrangements for the supply of MS plain rod / RTS rod and GI binding wire)

3035

-

-

... More
24. MCCB of 250A capacity with magnetic thermal overload release, instant start circuit trip and under voltage release switch

-

-

-

... More
condenser coil, evaporator with evaporator fan motor with suction, discharge and liquid copper refrigerant piping and expansion device etc., complete operating on with power supply at 230V +/10% single Phase/50Hz AC supply.

-

-

-

... More
Supply and clamping of 3-1/2 x 50 sq.mm. aluminium PVC LTUG armoured cable on post or on wall with MS clamps.

110

-

-

... More
12. 1 set low voltage HRC fuse for the short circuit protection of the alternator

-

-

-

... More
20 mm dia CPVC Elbow

50

-

-

... More
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.

285

-

-

... More
Supply and insallation Cabinet Type Class 1 and 2 Combined Model SPD in 4P enclosure box to arrest surges and overvoltages in the power line due to lightning switching action etc. they must be installed in the incoming MCC panel / DB of the respective building in parallel to the power circuit by using 4 of 6 Sqmm Cu(84 / 0.3) .Model: PSV4-12.5/400TT (3 phase power network)

1

-

-

... More
Supply and Installation of 400A Flange End for raising mains with necessary accessories and connections complete.

2

-

-

... More
Plastering with cement mortar 1:3 (One cement and Three Plastering sand (P-sand) 12 mm thick mixed with bonding agent Cebex112, Zydex-Zycrete 2x or other equivalent compound conforming to BIS at 200 ml of one cement bag (50kg) for increased workability and air entrainment used finished in all floors including curing etc. complete complying with standard specification and as directed by the Departmental Officers.

178

-

-

... More
(M)TESTING AND COMMISSIONING

-

-

-

... More
For plane surfaces such as sides and bottom of RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.

7290

-

-

... More
Supplying and fixing of PVC Sliding Door with Roller

2.1

-

-

... More
K)Supply of manuals for operation & maintenance of DG set with warranty card etc. L) CEIG approval: Preparation of site plan physical layout, electrical line schematic Diagram 10 sets, getting drawing approval from CEIG preparation of complection report rectification report etc., arranging CEIG inspection and obtaining CEIG safety certificate, payment of CEIG inspection fees if necessary and preparation of one set of approval Drawing and copy of safety certificate in a neat frame work.

-

-

-

... More
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box for 5A 3 pin non interlocking flush type CS plug with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open plug point (For Lift shaft)

21

-

-

... More
Supply, installation, testing and commissioning of 3400 Cfm 8.5 TR Nominal capacity factory assembled double skin ceiling mounted AHU with 50mm-45kg/cum PUF Insulated detachable panels, extruded thermal break aluminium profiles filled with PUF, panel external skin with 0.6 mm preplasticized sheet, panel internal skin with 0.6mm galvanized sheet, AMCA tested DIDW backward/forward curved centrifugal fan with EFF1 rating motor, drive arrangement with taper lock pulleys for fan and motor, vibration isolators out of heavy duty rubberized mounts,

2

-

-

... More
In Ground floor.

23

-

-

... More
Flooring with Anti skid Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm ceramic tiles laid over 20 mm thick cement mortar 1:3 (One Cement and Three Crushed stone sand (M-Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

246

-

-

... More
Double leaf

4

-

-

... More
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.

-

-

-

... More
Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete complying with standard specifications.

3

-

-

... More
32 mm dia G.M. Gate Valve

4

-

-

... More
Supply and fixing of 9W LED lamp for BH point.

42

-

-

... More
Supply and installation of air termination rod of 2mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories. It should satiesfy IEC 62561-1 & 2 and it should Withstand Minimum wind velocity of 150m/s.

8

-

-

... More
Nosing the granite for required shape and design with hand machine etc., complete complying with standard specification and as directed by the departmental officers. (Single Nosing)

667

-

-

... More
C) Supply, fabrication and erection of 4Nos of telescopic structure sliding in the fixed channel within the cabinet each to hold 120kgs of weight when it is stretched fully out.

-

-

-

... More
Stage-3: Spraying anti-termite chemical solution on the M-Sand for the flooring before laying the flooring concrete. This treatment has to be carried out on the M-Sand filling by making holes with crow bar to a depth of 60 cms and at 60cms intervals on both.

-

-

-

... More
110mm dia PVC Pipe

148

-

-

... More
Design, Supply,Installation, Testing of 400A, 3L+N, Sandwich type Aluminium Bus Bar Trunking system, Straight run feeder (Rising Main)Indoor IP55 protected, insulation class F (155oC), Dust and Vermin proof made up of Galvanised iron, with provisions for Aluminium Earthing Plug in points at every floor necessary angle iron supporting etc.Reference standard: IEC 61439-6. Reference temperature: 40 °C, Protection degree: IP55. Thickness: 1.6 mm, N° of conductors: 4. Painted: RAL 7032 . Halogen Free, The insulation between bars is ensured by a multi sheath made with PET film class F(155°C)Complete with Aluminium busbar Flexible with provision for rotary handle mechanism with bottom Cable entry and top Busduct outgoing provision and connections complete.

45

-

-

... More
Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.

96

-

-

... More
50 mm dia CPVC Union

10

-

-

... More
In Ground Floor

18

-

-

... More
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting.

13

-

-

... More
25. Indication: UP/Down digital direction and position indicator for all landing and in car 26. Emergency Alarm Bell: Battery operated alarm bell to be provided with Automatic charging device. 27. Emergency light: Battery operated light to be provided with Automatic charging device. 28. Fireman’s switch: To be provided at ground floor 29. Minor builders work: to be provided by lift contractor. 30. Scaffolding: to be provided by lift contractor

-

-

-

... More
Supply and fixing of flexible Canvas connection

8

-

-

... More
In Third floor

89

-

-

... More
29.Audio and Visual indicator arrangements for: a) Low lubricating oil pressure b) High water temperature c) Over speed

-

-

-

... More
In Sixth floor

79

-

-

... More
1. Location: Government Hospital - 50 Bedded Critical Care block (G+5) 2. No of Lift : 1No 3.Type of lift : Dumb waiter 4. Capacity of lift : 240kg

-

-

-

... More
5. Speed : 1.0 m/s 6. Type of Drive: Specific variable voltage variable frequency V3F drive with enhanced ride comfort and near Zero leveling functions.

-

-

-

... More
16. Lift well existing: 2300mm (width) x 3000mm (depth) 17. Lift pit depth available : 1600mm 18. Car size (Clear inside): 1300mm (wide) x 2400mm (Depth) 19. Car clear opening: 1200mm width x 2000mm height 20. Lift machine room as Existing size. 21. Power supply: 400/440 3 phase, 50 Cycles/sec A.C. supply for power and 230 V, 50 HZ, single phase, supply for lighting. 22. Control: Micro processor based simplex selective collective simplex 23. Car fittings: sleek LED light fitting with 300mm blown type fan 24. Lift well: R.C.C. construction with brick masonry.(Existing)

-

-

-

... More
with 1" x 1/8" tinned cu. Flat for 3 phase & neutral, 1" x 1/8" tinned cu flat for earth connection with bus bar insulators. The following tinned Cu flat should be used for interconnection between busbar and switches: 1" x 1/8" tinned cu. Flat for interconnection of 1No 125A incoming switch to bus bar and no.8 swg copper conductor for interconnection of 5Nos 63A Outgoing switches to bus bar.

-

-

-

... More
Supplying and fixing position PVC Nahani Trap of the 100 x 75 mmwith best gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three m-sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)

72

-

-

... More
1) Cooling 2) Dehumidifying 3) Air circulating 4) Filtering The installation work for the above split type AC units inculdes the following 1. Mounting/ Fitting Indoor and Outdoor units at the respective locations. 2. Laying refrigerant pipeline of required length connecting both units after drilling hole/holes in the wall, if required. Thickness of copper tubing shall not be less than 0.8mm

-

-

-

... More
Supplying and fixing in position best approved of BIS quality of PVC rain water down fall pipes having a working pressure of 4 kg/cm2 including cost of necessary PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cost of removable of iron grating. The PVC pipe shall be fixed in wall with Special type of 'U' clamp at the centre of the pipe line in addition to those for more than 3m pipe length etc., complete complying with standard specification.

-

-

-

... More
Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. aluminium PVC armoured LTUG cable with earth connection

6

-

-

... More
Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail

-

-

-

... More
Stage-2: Spraying anti-termite chemical solution to the grade beam level, spraying has to done for the grade beam, brick masonry contact with the back fill earth.

-

-

-

... More
In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylum sheet separators, and properly earthed by tinned solid copper flat as per CEIG sepecifications. The earth bus with two runs of 1" x 1/8" tinned copper flat must be run all round the panel to provide double earth connection. The panel should be painted with two high quality enamel paint over one coat of red oxide primer, the cable size, capacity of switch, location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel 3"x1½"x½" iron frame work support complete. (The TPN switches should be L&T / Siemens make only)

-

-

-

... More
a. Transformer / Rectifer b. DC Ammeter c. DC Volt meter d. ON / OFF switch e. Charging rate selector switch f. push button start g. push button stop h. push button reset

-

-

-

... More
In Fourth floor

166

-

-

... More
39. Other standard features: Voltage stabilizer for control units, Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electromagnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limits switch, main suspension ropes counter weights lifting hoist for mounting the machineries.

-

-

-

... More
23. 1set Pilot lamps of 3 nos

-

-

-

... More
Brick partition walls of 10.80cm thickness using best quality country bricks of size 8-3/4" x 4-1/4" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three Crushed Stone sand (M-Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)

-

-

-

... More
Plastering with cement mortar 1:5 (One cement and five Plastering sand (P-sand) 12mm thick mixed with bonding agent Cebex112, Zydex-Zycrete 2x or other equivalent compound conforming to BIS at 200 ml of one cement bag (50kg) for increased workability and air entrainment used finished in all floors including curing etc. complete complying with standard specification and as directed by the Departmental Officers.

7309

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.