Municipal Administration And Water Supply Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Municipal Administration And Water Supply Department - MAWS Tender
Civil And Construction
Eprocure
Opening Date27 Sep 2024
Closing Date3 Oct 2024
Tender Amount₹ 3,31,00,000
Costs
EMD
₹ 3,31,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAWS_488819_1Bid Award Id
ViewTender No
ROC NO.4812-1/2016/E1Tender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://https://www.tn.gov.in/maws/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply and filling in foundation with Filling M Sand in layer of 15cm thick well water rammed to consolidation including cost and conveyance of Sand to site incluidng labour charges etc., complete as per standard specification
88.2
-
-
Plain Cement Concrete 1:4:8 (one cement, four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and labour charges and all incidential charges such as water providing etc., complete as per standard specification
88.5
-
-
Supplying and filling the basement with Good Earth filling in layers of not more than 15cm thick well rammed watered and compacted - etc., complete complying with standard specification.
28
-
-
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) - Centering 1
1036
-
-
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
1517
-
-
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
63.9
-
-
Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
471
-
-
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
-
-
-
Basement
361.9
-
-
Ground Floor
14.1
-
-
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
33832
-
-
Brick work in CM 1:5 (one cement & Five sand) using fly ash bricks of size 230 X 110 X 75mm in standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost)
763
-
-
Brick partition walls of 10.80cm thickness using best quality country bricks of size 8-3/4" x 4-1/4" x 2-1/4" in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
90.8
-
-
Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
1737
-
-
Plastering with cement mortar (1:3) 10mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309
95.2
-
-
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding, grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
8276.8
-
-
Paving the floor with design antiskid ceramic tiles (colour and shade as directed) of size 305mm x 305 mm x 6mm in all floor aver a base layer of cement mortar 1:3 (one cement and three sand) 20 mm thick laid in situ and pointed with same coloured cement.
86.2
-
-
Dadooing walls with Glazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed.
86.2
-
-
White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed.
95.2
-
-
Painting two coats of newly plastered wall surface with approved cement paint over cement plastered wall surface, ceiling and including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required and cost of painting materials, brushes, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer
972.3
-
-
Painting the new iron work with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat and including cost of painting materials, brushes, putty, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer.
414.4
-
-
Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for paneling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rebate for housing the shutter and should have provision to fix AL drops, tower bolt hinges and lock plates inclusive of cost of all materials etc. complete complying with thew standard specifications.
27.1
-
-
Supplying and fixing in position of alulminium anodised colour matt finish Louvered Ventilator. The outer frame will be 62x38x2mm @ 1.17 Kg / m and the louvers with moving arrangements will be made with Alu. Channel of size 60x30x4 mm @ 1.27 kg /m with necessary glass pans for louvers 4mm thick Al. Clips, including all materials, labour & power consumption charges required for fabrication if necessary chipping dismantling making holes in RCC columns,beamsor masonry wherever necessary with power drill to the extent required and make good to the original conditions after fixing etc., complete. The Aluminium sirface is to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 of anodic film thickness of not less than15 microns (fifteen) for all sections.
5.4
-
-
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
18
-
-
Supplying and Fixing of Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1 mm thick) of size 100 mm x 60 mm with a rebate of 30/ 35 mm x 15 mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel Hold fast etc.,
PWD SOR P.NO 158
20
-
-
Supplying & fixing door shutters for Mediun Density Fiber Board of exterior grade 35 mm thick,single leaf conforming to IS:12406/1989 with 35x12 mm T.W.Lipping on all edges with necessary adhesives and CP screws complying with standard specifications. The rate is inclusive of threee coats of best quality varnish but excluding cost of furniture fittings.such as 300 mm tower bolt 2nos,200mm towerbolt I no. 300mm Aldrop 1 No. Alu handle ornamental type 2 Nos,and 1 No. Door stopper etc complete.
12.6
-
-
Supplying and fixing in position best approved of BIS quality PVC Waste water pipes having a pressure of 6 kg. / sq.cm including cost of special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 6.0 meter pipe length, etc., complete complying with standard specification.
-
-
-
110mm dia pipe
28
-
-
90mm dia pipe
8
-
-
Geophysical investigation charges etc.Complete.
1
-
-
Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site
will be shown by the TWAD Board Officers) including construction of mud pit.(TWAD 2024-25,P.No.198)
-
-
-
Upto 60 m Depth ending below ground level
60
-
-
From 60 m upto 90 m Depth ending from ground level
30
-
-
From 90 m upto 120 m Depth ending from ground level
30
-
-
Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer.(TWAD 2024-25,P.No.199)
-
-
-
Upto 60 m Depth ending below ground level
60
-
-
From 60 m upto 90 m Depth ending from ground level
30
-
-
From 90 m upto 120 m Depth ending from ground level
30
-
-
Supply and delivery of 150mm PVC Casing Pipe including cost of Pipe and Conveyance charges and all material and all labour charges etc.complete.(TWAD 2024-25,P.No.6)
120
-
-
Labour Charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the executive engineers of TWAD Board.(TWAD 2024-25,P.No.192)
120
-
-
Supply and delivery of clear water vertical wet type submersible pump conforming to IS
8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %,50 HZ +/-5 % as approved by the executive engineers of TWAD Board.(20Lpm x 100m)(1.5hp)(TWAD 2024-25,P.No.102)
1
-
-
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/single Phase/50HZ(± 5%) and 230 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately.(1.50hp pannel board)(TWAD 2024-25,P.No.119)
1
-
-
Supply and delivery of MS Kiosk of size 0.75m x 0.45m x 0.75m made up of MS angle of size 50mm x 50mmx 4mm alround covered with 16 gauge MS sheet and kiosk door made up of MS plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements etc., (TWAD 2024-25,P.No.91)
1
-
-
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth valves erection clamps, pressure gauges uptp the exterior wall of pump room and erection of panel board consisting of TPICN swithces starter, voltmetre, ammetre, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10days. (TWAD 2024-25,P.No.204)
1
-
-
Supply and delivery of 40mm Dia UPVC Coulum pipe for Submersible Pipe Heavy type with ISI Mark each pipe 3m Length with Coupler Joint including cost of Pipe and conveyance charges etc complete.(TWAD 2024-25,P.No.07)
70
-
-
Supply and delivery of 4.0 Sq.mm PVC insulated and sheathed 3 core flat type copper cable conforming to is 694/1990 including cost and conveyance charges etc complete(TWAD 2024-25,P.No.124)
80
-
-
Earth work excavation and depositing on bank with an initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton, hard red earth, shales, murrams, gravel, stoney earth, and earth mixed with small size boulders and hard gravelly soil -SS20B(TWAD 2024-25,P.No.197)
132
-
-
Lowering GI pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Officers(TWAD 2024-25,P.No.161)
132
-
-
Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by officers(TWAD 2024-25,P.No.193)
132
-
-
Supplying, laying and jointing G.I. Pipes of approved quality and best variety of "B" class pipe of the following dia including labour fixing G.I. Specials, including charges for cutting and threading of pipes, cost of such specials with necessary teak wood plugs, clamps, screws, thread balls, shellac, etc., etc., complete (TWAD 2024-25)
-
-
-
50mm GI Pipe B Class
120
-
-
32mm GI Pipe B Class
12
-
-
32mm GI Elbow
12
-
-
20mm GI Coupling
4
-
-
20mm GI Bend
4
-
-
20mm GI Elbow
4
-
-
20mm GI Tee
2
-
-
Supply and run of 4 x 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in 32mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron up right and end supports for mains SD No.73
15
-
-
Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading,unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., 1000 litres capacity
2
-
-
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.
-
-
-
25mm dia
60
-
-
32mm dia
20
-
-
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
-
-
-
25mm Gun metal Gate Valve
2
-
-
32mm Gun metal Gate Valve
2
-
-
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
-
-
-
SD Tap
9
-
-
Pillar Tap
26
-
-
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
-
-
-
110mm dia PVC Elbow
13
-
-
90mm dia PVC Elbow
1
-
-
110mm dia PVC Elbow with Door
13
-
-
90mm dia PVC Elbow with Door
1
-
-
110mm dia PVC Tee
11
-
-
90mm dia PVC Tee
1
-
-
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthenware wash hand basin of size 550 x 400mm (with pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylon connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
8
-
-
Supplying and fixing in position C.P. Towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plug and C.P. Screws etc. complete complying with standard specification.
4
-
-
Supplying and fixing in position Indian Water Closet (Oriya type) of size 580 x 440mm White/Color glazed earthen ware of approved quality and brand with "P" or "S" trap conforming to BIS with Sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two Sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
2
-
-
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings.
10
-
-
Supply and fixing in position of best Indian make white / colour glazed earthenware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masonry and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
4
-
-
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of Sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three Sand ) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)M-0571
20
-
-
Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of "U" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm]
5
-
-
Providing rain water harvesting using 3 No.of RCC well rings of 90cm inner dia (clear) with 5cm wall thickness made out of cement concrete 1:2:4 using 20mm hard broken jelly to a height of 30cm each supplying and fabricating 16 No. of 6mm dia MS rod vertically and 3 No. of 6mm dia MS rod circumferentially tied together with 18 guage binding wire for well rings including necessary earth work excavation 1m dia to a depth of 1m, supplying and filling 40mm HBG inside the erected well ring to a depth of 90cm, and top covered with RCC circular perforated cover slab of 1m dia and 5cm thick which inclusive of cost and fabrication of 6mm M.S reinforcement at 15 cm spacings on both directions and one 6mm M.S rod ties at the edge of the slab circumferentially including cost of moulding, curing, finishing and well placing in position and disposing off excavated earth with all initial leads and lifts in places as shown by the Departmental officers etc., complete in all respects.
1
-
-
Earthling as per ISI Specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangement using charcoal, common salt, G.I.reducer, check nuts etc., and masonry work and providing RCC cover slab 38mm thick for the Brick masonry including cost of steel and fabrication of reinforcement etc., complete in all respects as directed by the departmental officers. (SD 211)
1
-
-
Supplying and run off 8 SWG copper wire on walls or below ground level with necessary 'U' nails, earth work excavation and refilling & including the cost of all materials etc., complete in all respects as directed by the departmental officers.(SD 75)
10
-
-
Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB as outgoing on suitable angle iron frame on wall with earth connection only. Lower End etc.complete in all respects as directed by the departmental officers (SD 529)
1
-
-
Supply and run off 2 of 2.50sqm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continuous earth connection by means of 1.50 sqm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departmental officers. (derived from SD 55)
10
-
-
Supply and run off 2 of 1.5 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (derived from SD 54)
1
-
-
Supply and fixing of TNEB meter Board suitable for 32 A Three phase service connection with 32A fuse unit(500V)32A neutral link and earth link (1" x 1/8" Copper flat) on T.W plank of size 600mm x450mm x 19mm with supportingT.W.reepers of 1" thick oneither sider with painting withsuitable bolt and nuts for fixingthe TW plank on wall withearth connection and interconnection with 7/20 PVCinsulated copper wire from EBmeter to fuse unit. SD 128)
20
-
-
Supply and run of 4 core 10 Sq.mm PVC Armoured cable of 1100 V grade with ISI mark.(M-1561)
10
-
-
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). SD 23
23
-
-
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for 5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. SD 38
10
-
-
supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. ( SD 441)
23
-
-
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall (SD 114)
2
-
-
supply and fixing of 65 mm dia. (2 -1/2") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour .
20
-
-
Supply and laying of 2 x 6 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth tomake good
800
-
-
Supply and fixing of 12 Mtr Mini Mast suitable for 180 km/hr wind speed and siitable for mounting Max 6.of luminaires consisting of : Head Frame, Movable lantern carriage,Double drum Winch 6mm 316 Grade, S.S Hoisting ropes of 7/19 construction Flexible Multicore cable Trailing cable - 5core X 4sq.mm 1per mast Foundation Bolts & Nuts Anchor Plate & Template,Lightning finial Twin aviation light (GLS type), Power tool (Integral) ,Feeder Pillar for automatic operation, Casting of Foundation and Installation / Testing & Commissioning Supply, installation of 8Nos of 150W LED
fittings with CG boxes and lamps.
1
-
-
Supply and errection of CCTV in the following items.
-
-
-
Armoured cat-6 cable (PWD SOR page no:164)
750
-
-
POE switch for camera - 8 port (PWD SOR page no;165)
1
-
-
Hard disk for NVR 6 TB (PWD SOR page no;165)
1
-
-
Net work video record for CCTV 8 Channel - 1 SATA 1 No Hard disk (PWD SOR page no;165)
1
-
-
CCTV camera
7
-
-
Rack with Accessories 6U Rack (PWD SOR page no;166)
1
-
-
I/O SOKET RJ 45 (PWD SOR page no;166)
7
-
-
I/O SOKET RJ 11 (PWD SOR page no;166)
7
-
-
32" LED TV
1
-
-
Supply and Erect tensile membrane structure for Bus Shelter as per the Specification and Design below. Steel: Steel design, fabricated and supplied and erected as per the analysis wing NDN design software with minimum thickness of 3.20mm thickness and approx tonnage of 1.20 to 2.50 kg Wt/Sq.ft varying as per the design shown in the drawings the steel to be of ISI approved make and has to fabricated and supplied with one coat of Epoxy primer to site. The lugs/cleats and base plates to be prefabricated and to comply as per design standards of Reports. The steel to be designed for a wind speed of 55m/sec as per the IS code. The steel to be finished with two coats of Epoxy white roller finish at site. Fabric: The fabric has to be PVC fabric with cross link of Seon with a life expectancy & 5 years and has to be patterned as per NDN software and has to be welded and high frequency machine with a minimum weld width of 40mm. The fabric to be fixed with necessary Aluminum extrusion of minimum 3.20 to 4.00mm thickness flats or special extrusion. The fabric fixed should be made in such a way sufficient stiffness is there in the fabric(Q)
523
-
-
Providing and laying, spreading and compacting graded stone aggregate to Wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications.
80
-
-
Supplying and laying Rubberised interlocking Paver block M40 grade Providing and laying of 83mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with sand cushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub base, sand cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
795
-
-