Municipal Administration And Water Supply Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Municipal Administration And Water Supply Department - MAWS Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date7 Nov 2024
Closing Date19 Nov 2024
Tender Amount₹ 6,25,000
Costs
EMD
₹ 12,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Tiruppur Corporation_mla_2024-25_5
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAWS_499362_5Bid Award Id
ViewTender No
E1/3975/2024Tender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://https://www.tn.gov.in/maws/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Reinforced cement concrete 1:1½:3 [one cement, one and half M-Sand and three course aggregates] using 20mm size Hard Broken/Machine crushed Granite Stone Jelly for all RCC items of works excluding centering, shuttering and cost of reinforcement, including curing, fixing fan clamp and fixtures if necessary etc., complete complying with standard specification
4
-
-
Supplying and erecting centering for soffits of Square / Rectangular Columns including strutting 3m high using mild steel sheets of size 90cm x 60cm and BG 10 stiffened with M.S angles of size 25mm x 25mm x 3mm laid over silver Oak (C.W) joists of size 10cm x 6.5cm (spaced at about 90cm c/c) and supported by casurina props of 10cm to 13cm dia (spaced of 75cm c/c) etc., complete complying with standard specification
15
-
-
Filling in foundation and basement with excavated earth (or) soil in layers of not more than 15cm thick well rammed, watered and compacted etc., complete complying with standard specification.
12
-
-
Supplying and erecting centering for soffits of plane surfaces like RCC Slabs, Lintels, Sunshades, Square Columns, Staircase waists, Beams etc., including strutting 3m high using mild steel sheets of size 90cm x 60cm and BG 10 stiffened with M.S angles of size 25mm x 25mm x 3mm laid over silver Oak (C.W) joists of size 10cm x 6.5cm (spaced at about 90cm c/c) and supported by casurina props of 10cm to 13cm dia (spaced of 75cm c/c) etc., complete complying with standard specification.
5
-
-
Ceiling Plastering with cement mortar 1:3 mix (one cement three P-sand), 10mm thick in all floors for RCC slabs, Beams, Sunshades including packing, providing cement mortar beading for sunshades, staircase steps, landing slabs etc., as directed by the departmental officers etc., complete complying with standard specifications.
5
-
-
Plastering with cement mortar 1:3 mix (one cement three P-sand), 12mm thick in all floors using clean screened M-Sand and including cost of curing for fifteen days from the completion of the work and surface should free from undulations and including the cost of preparing the surface for plastering and protecting from other damages till setting of mortar etc., complete complying with standard specification.
4
-
-
White washing one coat with freshly burnt white shell lime in all floors including cost of lime, blue powder, fevicol type gum, brushes, scaffolding charges etc., complete complying with standard specification.
16
-
-
Geophysical Survey Charges for Locationg bore well drilling etc., complete
1
-
-
Drilling of 150mm Verticalbore in hard rock areas to the requied depth as directed by departmental officers including labour charges for inserting casing pipe assembling in the drilled holes including welding the jointing if necessary grouting the casing pipe etc., and including transportation charges for the rig and supporting vehicle from one place to another
-
-
-
Upto 150M Below GL
150
-
-
From 150M to 180M
30
-
-
From 180M to 210M
30
-
-
From 210M to 240M
25
-
-
From 240M to 270M
15
-
-
Supplying, Deliverying and Erection of PVC 150mm non pressure casing pipe of 6mm thick in the bore well at top level in position of projecting of 0.30m above ground level including inserting charges, conveyence of all items in site cost of labour charges and with one supporting vehicle etc., complete as per standard specifications
18
-
-
Supply and Delivery of 50mm dia UPVC Column Pipe with ISI make etc., complete as per standard specification
231
-
-
Supply and delivery of (75LPMx225M) 7.50 HP Bore well submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 %
1
-
-
Supply and Delivery of PVC insulated and sheathed 3 core 4 sq.mm flat type copper cable conforming to IS 694/1990 and as Amended Thereafter
260
-
-
Supply and delivery of 7.50 HP Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 Nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately)
1
-
-
Supply and delivery and fixing of 3000 Litre HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,
1
-
-
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
1
-
-
Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1" x 1/8" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit
1
-
-
Supply and fixing of 32A fuse unit (500V) as per standard specification
3
-
-
Supply and run of 4 of 4 sq.mm (56/0.3) PVC insulated SC unsheathed FRLS copper conductor of 1100V grade on 7/20 GI bearer wire for service connection mains
10
-
-
Supply and run of 4 of 4 sq.mm (56/0.3) PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in 25mm dia GI pipe (Class 'B') bent at both ends with necessary angle iron up right and end supports for mains
3
-
-
Earthwork excavation for Narrow Trenches in all soils and sub soils except in hard rock requiring blasting and depositing on bank with initial lead of 10m and initial lift of 2m inclusive of shoring, shuttering, bailing out water wherever necessary, refilling the foundation with excavated earth other than sandy soil in layers of not more than 150mm thick layers well rammed and depositing the surplus earth within the compound in place shown by the departmental officers and clearing and levelling the site etc,. complete.
36
-
-
Supply of the following size of PVC 6Ksc Pipe with ISI specification as directed by departmental officer etc., complete as per standard specifications
-
-
-
63mm Dia PVC Pipe
80
-
-
Supply and delivery of the following size of PVC Pipes with IS specification etc., complete.
-
-
-
50mm dia GI Elbow
1
-
-
50mm dia GI Bend
1
-
-
50mm dia GI Union
1
-
-
50mm dia GM Non Return Valve
1
-
-
50mm dia GM Gate Valve
1
-
-
63mm PVC Elbow
15
-
-
63mm PVC Tee
10
-
-
63mm PVC Bend
5
-
-
63mm PVC Coupler
5
-
-
63mm PVC End Cap
5
-
-
63mm PVC MTA
10
-
-
PVC Adhesive (Solution)
5
-
-
Lowering of PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste.
-
-
-
63mm Dia PVC Pipe
80
-
-
Add G.S.T. @ 18%
-
-
-