Municipal Administration And Water Supply Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Municipal Administration And Water Supply Department - MAWS Tender
Eprocure
Opening Date4 Nov 2019
Closing Date13 Nov 2019
Tender Amount₹ 25,00,000
Costs
EMD
₹ 25,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Namakkal Municipality Repair And Maintenance Toilets And Buildings At Chinna Muthalaipatty Middle School In Ward No 3
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MAWS_143541_1Bid Award Id
ViewTender No
9186/2019/E1Tender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://https://www.tn.gov.in/maws/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and erecting centering for sides and soffits including supports and strutting up to 3.29m high for plane surfaces such as RCC Slabs,Rectangular beams,Tee (or) ELL beams,Lintels,bed block,slabs,landing beam,canopy side slab,or boxing (or)vertical slabs,rectangular (or) quare(or)round columnsetc.,as detailed below with all cross bracings using M.S Sheets of size 90cmx60cm and B.G 10 Stiffended with welded M.S.Angles of size25mmx25x3mm for boarding laid over silver oak(or)country wood joist of size 10cmx6.5cm spaced at about 90cm centre to centre and supported by casurina props 10cm to 13 cm dia spaced out 75 cm centre to centre or at suitable intervals etc.,complete complying with std.specification
265
-
-
Reinforced Cement Concrete 1:1½:3 Mix (One part cement, one and half part sand and three part of aggregate)using 20mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing but excluding cost of reinforcement etc. Complete with std. Specifications.(Using Vibrator) TNDSS NO: 30 V, VI (S3), VII-3.
42
-
-
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification
41
-
-
Plastering in Cement Mortor 1:5 Mix (one cement, five sand) 12mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.
450
-
-
White washing Two coats with good quality of Shell Lime including cost of all materials to site and all labour charges for mixing, applying and proper curring etc., Complete as per Standard Specifications.
600
-
-
Cement paint Two coats with good quality of approved cement paint including cost of all materials to site and all labour charges for mixing applying and proper curring etc., Complete as per Standard Specifications.
800
-
-
Paving the floor with descrigned coloured Vitrified tiles of size 600 x 600 x 8mm of best quality and approved variety complying / confirming ISI specification land over cement mortar 1:3 (one cement and three sand) 20mm thick and pomted with same coloured cement neatly etc., complete.
40
-
-
Special ceiling Plastering in Cement Mortor 1:3 Mix (one Cement, Three sand ) 10mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete . complying with std. specifications
75
-
-
Weathering Course with broken brick jelly 20mm size pure slacked lime over R.C.C. roof slab the preparation of 32:12.5 for required depth and slope etc. complete.
185
-
-
Finishing the top of roof with one course of machine pressed tiles 23 C.m x 23 C.m x 2 C.m size using cement mortor 1:3 mix mixed with 2% by weight of Crude Oil and pointing with Cement Mortor 1:3 mix Cost of all materials and labour charges and brick jelly concrete etc., complete as per standard specifications.
185
-
-
Providing and laying of 80mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver block in required sizes of minimum compressive strength of 40 N/mm2 in uniform shape of approved make to be laid in flurrying bone pattern with approved non sticking surface in the top and the rate including leveling the base preparation of sub base with stone dust cushion 100mm thick, laying out the pavement cut the pieces to fit the edge, vibrating the pavers, sweeping transporting, loading unloading and laying of paver block as per standard specification.
250
-
-
Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with switch box with 5A F.T. switch inflush with wall and covered with hylum sheet of 3mm thick with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for light point / Fan point SD-2
15
-
-
Supply and fixing of single box type 4'36 W flu fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. SD-87
15
-
-
Supply and fixing of 1200 mm (48") sweep AC ceiling fan complete with stepped electronic 300W regulator, with 1 metre down rod with fan clamp with side plates and cross arm of size 450 mm (18") SD-106
10
-
-
Wiring with 2x4sqmm (56/0.3mm) PVC insulated SC unsheathed Cu. Cable conductor cable of 1100V grade in suitable heavy gauge M.S.conduit pipe on wall and ceiling with M.S.accessories with 150mm x 100mm x 75mm MS switch box for 15A 3 pin non interlocking CS plug with painting of suitable colour,with continuous earthwire connection by 14 SWG TC wire for open power plug point. SD-13
5
-
-