Municipal Administration And Water Supply Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Municipal Administration And Water Supply Department - MAWS Tender
Civil And Construction
Road Construction
Eprocure
Opening Date7 Oct 2024
Closing Date28 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 68,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAWS_491641_1Bid Award Id
ViewTender No
T.No. 140/2024-2025 Serial No.01Tender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://https://www.tn.gov.in/maws/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
22238
-
-
Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)
5364
-
-
Providing of Granular Sub base using Grade I materials of table 400 -1 of Morth with minimum CBR 30 spreading in uniform layers with motor grader on prepared surface, mix in by palce method at OMC and compacting with Vibratory Roller to achieve the desired density including all labourcharges etc, complete as per technical specification and as directed by the departmental officers. Morth - Rev V No. 111,112,401,900
1728
-
-
Cement Treated Crushed Rock or combination as per clause 403 and table 400.4 in Base (Providing, laying and spreading Material on a prepared sub grade, adding the designed quantity of cement to the spread Material, mixing in place with rotavator, grading with the motor grader and compacting with the road roller at OMC to achieve the desired unconfined compressive strength and to form a layer of base.)
1115
-
-
Providing and laying, spreading and compacting graded stone aggregate to Wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications.
674
-
-
Providing and laying Prime coat of 7 kgs/10 sqm over the WMM surface treated with primer using 7 kgs of bituminous Emulsion (SS) for 10square meter area including cost of bituminous binder, including labour charges for applying the required quantity of bituminous binder as Prime coat manually etc., complete as per 502 of MORTH Rev-5 Specifications
6733
-
-
Providing and laying tack coat of 2.5 kgs/10 sqm over the WMM surface treated with binder using 2.5 kgs of bituminous Emulsion (RS) for 10square meter area including cost of bituminous binder, including labour charges for applying the required quantity of bituminous binder as tack coat manually etc., complete as per 503 of MORTH Rev-5 Specifications
6733
-
-
Providing and laying compacted 50mm thick dense bituminous macadam using 0.24 cum of 26.5-13.2 mm graded metal and 0.25 cum of 13.2-2.36 mm graded metal and 0.23 cum of 2.36 mm & below metal with 53.20 kgs of VG40 bitumen for premixing per 10 sqm including cost and conveyance of all materials to C M P site, heating the bitumen and agregates to required temperature and mixing them in required temperature in central hot mix plant 20- 30 tonnes capacity conveying the mix by tipper trucks to paver site,spreading the mix in required temperature for uniform thickness of 50mm with mechanical paver to the specified grades and cross sections and compaction by Vibratory roller to the required density etc.,including labour charges for loading bitumen in to bitumen tank and metal to feeder unit,labour for attending to paver site etc., including hire charges and fuel charges for 20-30t C M P with bitumen boiler,tipper trucks, paver finisher, vibratory rollers and all other tools and plants required,including all other incidental charges etc.,complete using C M P clause 505 of MORTH Rev-5 specifications.
396
-
-
Providing and laying 40mm Bituminous concrete using 0.22 cum of 26.5-13.20 mm graded metal and 0.24 cum of 13.20-2.36 mm graded metal and 0.26 cum of 2.36 mm & below metal with 50.30kgs of VG40 bitumen for premixing per 10 sqm including cost and conveyance of all materials to C M P site, heating the bitumen and agregates to required temperature and mixing them in required temperature in central hot mix plant 20- 30 tonnes capacity conveying the mix by tipper trucks to paver site, spreading the mix in required temperature for uniform thickness of 50mm with mechanical paver to the specified grades and cross sections and compaction by 8-10 tonne Vibratory roller to the required density etc., including labour charges for loading bitumen in to bitumen tank and metal to feeder unit,labour for attending to paver site etc., including hire charges and fuel charges for 20-30t C M P with bitumen boiler,tipper trucks, 9m paver finisher, Vibratory / Pneumatic rollers and all other tools and plants required,including all other incidental charges etc.,complete using C M P clause 507 of MORTH Rev-5 specifications.
843
-
-
Providing and laying of Rubber Moulded Hydraulic Pressed Paver Block size 63mm thick in uniform shape of approved make to be laid in lorrying bone pattern with approved non sticking surface in the top and the rate including leveling the base, preparation of sub base with sand cushion 100mm thick, laying out the pavement, cut the pieces to fit the edge, vibrating the pavers, sweeping the sand grouting, providing transporting, loading unloading and laying of paver block as per standard specification.
582
-
-
Earth work excavation for drains in ordinary soil, light black cotton sandy loam and dry silt including shoring, strutting, baling or pumping out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick and depositing the surplus earth at places as directed by the departmental officers with initial lead and lift - 10 m3 - For Drains
858
-
-
Plaincementconcrete1:4:8mix(OnecementfourM.Sandandeightaggregate)using40mmsizeISSgaugeHBBGmetalincludingmixing,laying,consolidating,curing,costandconveyanceofallmaterialstositeandalllabourchargesetc.,complete as per standard specification - For Drains
815
-
-
Providing and laying in position Standardised Concrete Mix M-30 Grade (1:0.75:1.5) in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 340Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Q.dust, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) -(detailed data for 10 m3) - For Drains
579
-
-
Supplyinganderectingforshuttering,includingnecessarysupportsforplanesurfaceinfoundationandbasementforRCCcolumnfootings,Plinthbeams,staircasesteps,etc.,usingmildsteelsheetsofsize90cmx60cmand10gauge,stiffenedwithmildsteelangleofsize25mm x 25mm x 3mm for boarding, supported by silver oak joists of size 10 x6.5cm, spaced atabout90cmcentreandsupportedbycasurinapropsof10cmto13cmdiaspacedat75cmcentretocentrecomplete,complyingwithstandardspecificationsandasdirectedetc., complete - 1 m2-for drain
2061
-
-
Supply and Installation of Cast Iron Grating of size 600mm x 300mm @ 5m spacing
26
-
-
Supply and Laying of 110mm dia PVC pipe 6 Kg/m2
62
-
-
Supplying, fabrication and placing in position of steel reinforcement using mild steel of Ribbed tor steel rods, for all RCC works as per the design given by the departmental officers including cost of steel and binding wore and all labour charges for cutting, bending & tying etc., complying with standard specifications - For Drains
111
-
-
Earth work excavation for drains in ordinary soil, light black cotton sandy loam and dry silt including shoring, strutting, baling or pumping out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick and depositing the surplus earth at places as directed by the departmental officers with initial lead and lift - 10 m3 - For Retaining Walls
1411
-
-
Plain cement concrete 1:2:4 mix (One cement two M.Sand and four aggregate) using 20mm size ISS gauge HBBG metal including mixing, laying, consolidating, curing, cost and conveyance of all materials to site and all labour charges etc., complete as per standard specification - 1 m3 (detailed data for 10 m3 ) - For Retaining Walls
166
-
-
Providing and laying in position Standardised Concrete Mix M-30 Grade (1:0.75:1.5) in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 340Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Q.dust, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) -(detailed data for 10 m3) - For Retaining Walls
1104
-
-
Supplyinganderectingforshuttering,includingnecessarysupportsforplanesurfaceinfoundationandbasementforRCCcolumnfootings,Plinthbeams,staircasesteps,etc.,usingmildsteelsheetsofsize90cmx60cmand10gauge,stiffenedwithmildsteelangleofsize25mm x 25mm x 3mm for boarding, supported by silver oak joists of size 10 x6.5cm, spaced atabout90cmcentreandsupportedbycasurinapropsof10cmto13cmdiaspacedat75cmcentretocentrecomplete,complyingwithstandardspecificationsandasdirectedetc., complete - 1 m2 - For Retaining Walls
3943
-
-
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.
704
-
-
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications. Spacing 4.5m longitudinally
236
-
-
Providing and erecting of made out of retro reflectorised cautionary, mandatory and informatory signs (With definition board) made out of micro prismatic grade sheeting conforming to IRC 67:2012 & Type IV standards of ASTM D 4956-09 specifications and fixed over 2mm thick aluminium sheet & back support frame of stainless steel supported by 32 NB stainless steel pipe all around and 65NB pipe vertical post firmly fixed to the ground by means of property designed foundation with M15 grade cement concrete 30cmx30cmx45cm complete. The information message shall be made out of cut out letters in Blue color transparent overlay film as per IRC 67-2012 Guidelines, 7 years pre qualification warranty for Retro Reflective sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the reflective sheeting offered shall be submitted by the contractor including cost of all materials and labour charges etc., complete
-
-
-
60cm Equilateral Triangle
19
-
-
60cm Circular
11
-
-
90cm High Octagon
4
-
-
Providing and erecting of made out of direction and place identification signs made out of cube corner micro prismatic grade sheeting conforming to IRC 67:2012 & Type XI standards of ASTM D 4956-09 specifications and fixed over 2mm thick aluminium sheet & back support frame of stainless steel supported by 32 NB stainless steel pipe all around and 65NB pipe vertical post firmly fixed to the ground by means of property designed foundation with M15 grade cement concrete 45cmx45cmx60cm complete. The information message shall be made out of cut out letters in Blue color transparent overlay film as per IRC 67-2012 Guidelines, 7 years pre qualification warranty for Retro Reflective sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the reflective sheeting offered shall be submitted by the contractor including cost of all materials and labour charges etc., complete
186
-
-
Providing and erecting retroreflective hazard marker traffic signs made out of cube corner micro prismatic grade sheeting conforming to IRC 67:2012 & Type IV standards of ASTM D 4956-09 specifications and fixed over 2mm thick aluminium sheet & back support frame of stainless steel supported by 32 NB stainless steel pipe all around and 65NB pipe vertical post firmly fixed to the ground by means of property designed foundation with M15 grade cement concrete 45cmx45cmx60cm complete. The information message shall be made out of cut out letters in Blue color transparent overlay film as per IRC 67-2012 Guidelines, 7 years pre qualification warranty for Retro Reflective sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the reflective sheeting offered shall be submitted by the contractor including cost of all materials and labour charges etc., complete
6
-
-
Providing and fixing of median marker double sided made of polycarbonate for impact resistance and good weather ability. Polycarbonate used for moulding the marker shall have an izod impact strength of 600 j/m at room temparature. Impact strength of the polycarbonate should not reduce to less than 70% of its initial value on subjeted to UV weathering as per ASTM G155 for 1000 hours or exposure to 2 years of natural weathering. The body of the median marker shall be in the form of an isoceles trapezidal structure of size 15cm x 10cm x 10cm. The median marker shall have flourescent yellow retro reflective sheeting conforming to Type XI specifications as per ASTM D 4956. Area of relfective sheeting should not be less than 70 cm2. Edge of retroreflective shall be concealed using a grill/mesh/similar mechanism to prevent vandalism and sheeting proliferage. The logo of the manufacturer shall be embossed and painted in contrasting color on both side of the median marker for distinct identification. - Spacing of 10m c/c
277
-
-
Providing and fixing reflective road studs of 'category A ' Raised pavement markers made out of poly carbonate/methyl methercrylate/ ABS moulded body conforming to ASTM D 788 and reflective panels with micro prismatic lens capable of providing total internal reflecting of the light entering the lens face with retro reflectance and chromaticity values conforming to the morth circular No RW / NH. 33023/10/ 97 -DO. III dt 11.06.97.The height width and length shall not be less than 15 mm, 90mm, and 100 mm and with minimum reflective area of 13sq. cm on each side and the slope to the base shall be 35+/-5 degree. Each reflecter shall have a CIL not less than Values specified in table 2 of said MORTH circular. The strength of detachment of the integrated cylindrical shanks(of diameter not less than 19+/-2mm and height not less than 30+/-2mm)from the body is to be a minimum value of 500kgf. Fixing will be by drilling holes on the road for the shakes to go inside, without nails and using epoxy resign based adhesive as per manufactures recommendation and complete as directed by the engineer. The marker shall supporta load of 13635 kg tested in accordance with ASTM D 4280 and confirming to IRC35 - 2015 Guidelines and MORTH soecification 804 etc.., complete
564
-
-
Supplying of solar Raised pavement markers made of polycarbonate molded body, solar powered. LED self illumination in active mode, 360 degree illumination and reflective pannels with micro primatic lens capable of providing total internal reflect of the light entering the lens face in passive mode. The product shall support a load of 13635 kg tested in accordance to MORTH and ASTM 4280 Type H. The product should be resident to water ingress according to IP 65 standers with IS 12063 :1987 category 2 and should withstand temperature in the range of -7C to 70C.. Flashing rate and color of lighting is to be provided as per requirement. There should be minimum current lossess of less than 20 micro-amperes in sleep charging mode to enhance product life and single charges should provide for a minimum autonomy of 50 hours. The height width and length shall not be less than 10mm*100mm*100mm. Fixing will by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturs recommentation and complete as directed by the engineer. Warrenty certicate and test report conforming to compressive strength as per MORTH circular shall be obtain from the manufacturer and submitted to the engineer -in- charge. Two years warrenty certificate for solar RPM for the quantity installed and a certified copy of test reports from an independent test laboratory conforming to water ingress shall be obtained from the manufacturer by the contractor and submitted to the engineer-in- charge.
307
-
-
Providing and fixing of Retro Reflectorized overhead cantilever informatory sign made of cupe corner micro peismatic grade sheeting conforming to type XI standered IRC67-2012 and ASTMD4956-09, specification and fixed over 2mm thick aluminum sheet fixed on back supporting frame mild steel L angle of size 50mm*50mm*6mm. The vertical support post for the installation of overhead sign Gantry shall be made of 300NB ( Normal Bore) ms pipe wuth 12mm thick with a ground clearance of 6meters along with 80NB (Nominal Bore) MS pipe with 4 mm thick and 40NB Ms Pipe with 3.20mm thick support posts. MS base plate of size 1200mm*1200mm*25mm and MS top plate of size 900mm*1650mm*16mm to be used to hold the sign board at the top and bottom respectively MS stiffener plates 8mm thick of size 420*420, 682*420, 288*927, & 44*130 are to be used. Anchors bolts of dimension 25mm dia and 1000mm length are to be used as fixtures. The approved direction information should be digitally printed and should have 70% of the coefficient of Retro- reflection values against the value as mentioned in table 6.9 of IRC 67-2012. The latex printer usef for digitel printing should use inks with low VOC emissions and have green guard, eco logo certificate as per UL 2801 standerds. the retro- reflective sheeling shall be covered under 10 years warrenty Issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC67-2012(AS per MORTH specification No 801). Cantilever sign shall be installed at the side as per the approved structure and foundation drawing provide in the tender document and including cost and conveyance of all material, equipment, machineries, to work side, including all labore charges for fixing the gantry in position with all leads and lifts, loading charges and nessary for satisfactory completion of the work as directed by the engineer-in- charge etc..complete
1
-
-
Providing and laying of hot applied Thermoplastic compound 2.5mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5mm is exclusive of surface applied glass beads as per IRC:35. Finished surface should be uniform, level and free from streaks and holes etc. complete as per MORTH specification No. 803
1168
-
-
Manufacturing, supply & fixing of precast kerb stone of size 400mmx259mmx200mm thick made of M 20 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approved design i/c cost of all material, labour and curing etc.,complete. as per IRC 5758 - 1984.
1460
-
-
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
374
-
-
Providing and erecting single sided double guard metal beam crash barrier system 1.70m high, comprising of 3mm thick wall "W" beams posts and spacer channels shall be made by cold roll forming using HR conform to Is 5986 Fe 410/360 and dip galvanized having Zinc Mass of 550gms / sqm, minimum 950mm about road / ground level fixed on ISMC series channel vertical post 150*75*5mm spaced 2m center to center 312mm*83mm flange width *3mm thick, 4318mmlong post directly embedded in the concrete (M15) pit size 350*350*800mm for a debth of 750mm below ground. All fixing bolts and nuts hot dip galvanized conforming to IS : 1367 clause 4.60 all complete as per Technical Specification and directed by the Engineer-in- charge..
730
-
-
Providing, fitting and fixing mild steel railing as per IRC:103 complete as per drawing and Technical Specification
730
-
-
Supply and installation of 9 m Pole single arm with 210W LED street light with SMD type LED cool white Lighting Fixture made up of LM 6 Pressure Die cast aluminium housing with corrosion resistant painting confirming to IP 66 , Impact resistance = IK08 standards, separate compartment for LEDs & electronic driver, Power factor- 0.95, Operating voltage 120-277V universal electronic potted driver with Surge Protection of 10KV, CRI 70, The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The LED used in the luminaire shall be SMD type only of make Lumileds, Osram, Nichia, and CREE & no other make with SDCM 5. The LED drive current shall not be more than 1000mA. Test certificate from NABL accredited lab for LM 79 and LM 80 report . Aesthetically designed housing with Grey color corrosion resistant painting , with Anti Dust Exposed Lens & Side entry type shall consist of separate optical and control gear compartment. The luminaire shall be with dedicated street lighting unique peanut optic lens to ensure a better lux level along with uniformity as per IS1944 high spacing from pole to pole and cut-off type. The peanut lens shall be fixed mechanically and not to be with glue pasted. The driver shall be potted type. Unique air vents in housing design for better thermal management. The luminaire shall be used with high power LEDs delivering a nominal system lumen output minimum of 30000 lumens @ 210W nominal wattage with CCT of 5700K. The efficacy of the luminaire shall be greater than 140 lm / W. The pole entry of the luminaire shall be Side entry on standard pole 48-60mm.The luminaire shall be Class I electrical. The product shall be passed for EN 60598-2-3 for luminaires, EN 62471 photobiological safety, EN 61000-3-2 for harmonics, EN 61547 for EMC tests. All the components such as driver, SPD and LILO shall be within the luminaire. The luminaire should be of Class B Serviceability. (The driver can be replaced at site level). Specification for wire: PVC insulated & PVC Sheathed 3 Core Cable with Electrolytic Grade Annealed Copper Conductor suitable up to 1100 V Grade with ISI mark, Confirming to IS:694. The Driver should be potted /encapsulated & should be a BIS approved driver and not a printed circuit board without casing, mounted inside the luminaire. The luminaire and driver shall be BIS approved with "R" number mentioned. Driver Protections: Driver Protections 440V (P2P)Protection for 8 Hrs., High cut off @ 325±15V with Auto Restart. Foundation Bolt, Templates Including Transportation.Excavation & Providing foundation and fixing of street light poles as per approved drawing and finishing as directed by client.
75
-
-
Supply & Installation of hot-dip galvanized Octogonal Pole 9 mtrs height Pole along with 1.5m double arm bracket with 210W LED street light with SMD type LED cool white Lighting Fixture made up of LM 6 Pressure Die cast aluminium housing with corrosion resistant painting confirming to IP 66 , Impact resistance = IK08 standards, separate compartment for LEDs & electronic driver, Power factor- 0.95, Operating voltage 120-277V universal electronic potted driver with Surge Protection of 10KV, CRI 70, The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The LED used in the luminaire shall be SMD type only of make Lumileds, Osram, Nichia, and CREE & no other make with SDCM 5. The LED drive current shall not be more than 1000mA. Test certificate from NABL accredited lab for LM 79 and LM 80 report . Aesthetically designed housing with Grey color corrosion resistant painting , with Anti Dust Exposed Lens & Side entry type shall consist of separate optical and control gear compartment. The luminaire shall be with dedicated street lighting unique peanut optic lens to ensure a better lux level along with uniformity as per IS1944 high spacing from pole to pole and cut-off type. The peanut lens shall be fixed mechanically and not to be with glue pasted. The driver shall be potted type. Unique air vents in housing design for better thermal management. The luminaire shall be used with high power LEDs delivering a nominal system lumen output minimum of 30000 lumens @ 210W nominal wattage with CCT of 5700K. The efficacy of the luminaire shall be greater than 140 lm / W. The pole entry of the luminaire shall be Side entry on standard pole 48-60mm.The luminaire shall be Class I electrical. The product shall be passed for EN 60598-2-3 for luminaires, EN 62471 photobiological safety, EN 61000-3-2 for harmonics, EN 61547 for EMC tests. All the components such as driver, SPD and LILO shall be within the luminaire. The luminaire should be of Class B Serviceability. (The driver can be replaced at site level). Specification for wire: PVC insulated & PVC Sheathed 3 Core Cable with Electrolytic Grade Annealed Copper Conductor suitable up to 1100 V Grade with ISI mark, Confirming to IS:694. The Driver should be potted /encapsulated & should be a BIS approved driver and not a printed circuit board without casing, mounted inside the luminaire. The luminaire and driver shall be BIS approved with "R" number mentioned. Driver Protections: Driver Protections 440V (P2P)Protection for 8 Hrs., High cut off @ 325±15V with Auto Restart. Foundation Bolt, Templates Including Transportation.Excavation & Providing foundation and fixing of street light poles as per approved drawing and finishing as directed by client.
9
-
-
Design, manufacture, supply, erection, testing and commissioning of weather proof Street Lighting Panel with degree of protection not less than IP55 with canopy arrangement,fabrication with 1.6mm thick CRCA sheet. shall be in single compartments, suitable for operation on 3Phase 415 Volts AC Supply System, Neutral & Earth Bus bar.inter-connections with 10/2.5 sqmm single Core FRLS PVC insulated multistand copper conductor cable etc. single fronted, free standing, front hinged, dust & vermin proof, cubicle type, wall mounted, undrilled gland plates at bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following.Incomer:1 No - 32A TP+N MCCB 25kA , 1 No - 32A TP Contactor ,1 No - Digital 24Hrs Time Switch ,1 No - 32A Normal/Bypass Rotary Switch,1 No - 6A Auto/Manual Rotary Switch, Outgoings: 12Nos - 10A SP Mcb 10kA (Per feeder 4 Way)
2
-
-
Design, manufacture, supply, erection, testing and commissioning of weather proof 63A TNEB Metering Panel with degree of protection not less than IP55 with canopy arrangement,fabrication with 1.6mm thick CRCA sheet. shall be in two compartments, suitable for operation on 3Phase 415 Volts AC Supply System, Earth Bus bar.inter-connections with 10 sqmm single Core FRLS PVC insulated multistand copper conductor cable etc. single fronted, free standing, front hinged, dust & vermin proof, cubicle type, wall mounted, undrilled gland plates at bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. Incomer : 1 No - TNEB Meter Fixing Provision.Outgoings: 3Nos - 63A Cutout, 1No - 63A TP+N SDF+ HRC
2
-
-
Supply, Laying of 4C*35 Sqmm Al.Arm.Cable including cable trenching
377
-
-
Supply, Laying of 4C*25 Sqmm Al.Arm.Cable including cable trenching
3270
-
-
Supply, Laying of 3C*1.5 Sqmm Cu. Flexible Cable including all accessories like MCB's , connectors, Lugs etc..,
726
-
-
Earthing of panels & poles suiting site conditions
8
-
-
HDPE Supply & laying
3270
-
-
GIPipe Supply & Laying
377
-
-
HDD for Cable Crossing across the road
377
-
-
STRUCTURE WORKS
-
-
-
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1200 mm)
2120
-
-
Providing Steel Liner 10 mm thick for pile including Fabricating and Setting out as per Detailed Drawing.
234
-
-
Pile Cap
-
-
-
Earth work Excavation in all classes of soils except hard rock not requiring blasting and depositing on bank with all leads and lifts including cost of all labour, materials, tools, equipments and all other incidental charges such as bailing out water, shoring, strutting, walling and forming protective bunds wherever necessary etc and sheeting, shoring, bracing and their subsequent removal, removal of all logs, stumps and other deleterious matter and obstructions, trimming of bottom of excavtion backfilling, and clearing the site and disposal of all surplus materials etc. complete as per standard specification for Foundation under Abutments and Piers for foundation.
3648
-
-
M15-Plain cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
152
-
-
M35 Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
2639
-
-
Abutment
-
-
-
M35-Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
8
-
-
Abutment Cap
-
-
-
M35-Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
38
-
-
Dirt Wall
-
-
-
M35-Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
21
-
-
Return Wall
-
-
-
M35-Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
15
-
-
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.
65
-
-
Back filling behind abutment with granular material for wing wall and return wall complete as per drawing and Technical Specification
61
-
-
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications
5
-
-
PIER
-
-
-
M35-Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
1218
-
-
Pier Cap
-
-
-
M35-Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
917
-
-
PEDESTAL
-
-
-
M40-Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
62
-
-
PSC Girder
-
-
-
M45-Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
3210
-
-
High Tensile steel strands including stressing of strands and accessories for stressing operation, grouting complete as per drawings & Technical Specificationss Sections 1000 & 1800.
146
-
-
Diaphragm
-
-
-
M40-Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
203
-
-
Slab
-
-
-
M-40 Reinforced cement concrete including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
2609
-
-
Composite Girder
-
-
-
M-35 Reinforced cement concrete for slab above Steel girder,including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
143
-
-
Providing structural steel for super-structure complete as per drawing and technical specifications
253
-
-
Supplying and Fixing of ELASTOMERIC BEARING as shown in the drawing including cost and conveyance to work site, labour for fixing the bearing in position and all other incidental charges etc., complete as per section 2000 of MORT & H specification. (V Revision)
6144000
-
-
Supplying and installation of STRIP SEAL EXPANSION JOINT system conforming to specifications for road and bridge works in the 40mm wide expansion gap provided in between decks over piers and in between deck and dirt wall over abutment with fatigue tested structural steel section at the nosing and anchorage assembly,
including labour, equipment and incidental charges for fixing the joints complete in all respects, as per section 2600 of MORT & H specification (V Revision)
417
-
-
Crash Barrier including M-40 grade concrete centering, shuttering M.S. Structural members, anchore bolts, painting of Structural members but excluding the cost of reinforcements all complete as per drawing and Technical Specification Section 1500 and 1700
892
-
-
Utility pipe through the crash barrier 150mm dia PVC
2549
-
-
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
3823
-
-
Drainage Spouts complete as per drawing and Technical specification
511
-
-
Laying and fixing of PVC pipe 110mm dia connecting the drainage spouts
2772
-
-
M15-Plain cement concrete as levelling course for Approach slab including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 15 00 & 1700 in bridges, flyover and culverts.
13
-
-
M30-Reinforced cement concrete for Approach slab including centering and shuttering but excluding reinforcement all complete as per drawing and Technical Specificationss Sections 1500 & 1700 in bridges, flyover and culverts.
27
-
-
Supplying, fabrication and placing in position of steel reinforcement using mild steel of Ribbed tor steel rods, for all RCC works as per the design given by the departmental officers including cost of steel and binding wore and all labour charges for cutting, bending & tying etc., complying with standard specifications
1641
-
-
Providing and laying of 3mm thick water proofing membrane in the deck slab as per approved make and technical specifications
11599
-
-