Municipal Administration And Water Supply Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Municipal Administration And Water Supply Department - MAWS Tender
Eprocure
Opening Date12 Dec 2024
Closing Date20 Dec 2024
Tender Amount₹ 1,12,00,000
Costs
EMD
₹ 1,12,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAWS_510256_1Tender No
E3-20467-2024Tender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://https://www.tn.gov.in/maws/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Plain Cement concrete 1:4:8 [one cement, four sand and eight course aggregates] using 40mm size Hard Broken/Machine crushed Granite Stone Jelly including dewatering if found necessary and laid in layers of not more than 15cm thick and compacted etc., complete complying with standard specification.
37
-
-
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plinth Beam
158
-
-
Supplying and erecting centering for soffits of plane surfaces like RCC Slabs, Lintels, Sunshades, Square Columns, Staircase waists, Beams etc., including strutting 3m high using mild steel sheets of size 90cm x 60cm and BG 10 stiffened with M.S angles of size 25mm x 25mm x 3mm laid over silver Oak (C.W) joists of size 10cm x 6.5cm (spaced at about 90cm c/c) and supported by casurina props of 10cm to 13cm dia (spaced of 75cm c/c) etc., complete complying with standard specification.
252
-
-
Supplying and erecting centering for soffits of Roof Slab, Beam including strutting 3m high using mild steel sheets of size 90cm x 60cm and BG 10 stiffened with M.S angles of size 25mm x 25mm x 3mm laid over silver Oak (C.W) joists of size 10cm x 6.5cm (spaced at about 90cm c/c) and supported by casurina props of 10cm to 13cm dia (spaced of 75cm c/c) etc., complete complying with standard specification. (3.00m - 4.00m height)
817
-
-
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials)
-
-
-
Foundation & Basement
56
-
-
Ground Floor
37
-
-
First Floor
37
-
-
Second Floor
2
-
-
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors as per standard spedtlcatlon.
175
-
-
Brick work in cement mortar 1:5 mix using Fly Ash bricks of 230x110x70mm (8 3/4" x 41/4" x 23/4") including cost of materials and labour charges etc. as per std. specification - 1m3
-
-
-
upto Basement
34
-
-
Ground Floor
71
-
-
First Floor
71
-
-
Second Floor
7
-
-
Brick partition wall of 11cm thickness in CM 1:3 mix using best Fly Ashbricks 9"x4⅜"x2¾" bricks one Part of Cement, Three part Crushed Stone sand using hoop rod reinforcement if found accessary standard Specification etc., complete complying with standard specification.
48
-
-
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work (M-0674)
50
-
-
Manufacturing supplying and fixing of MILD STEEL DOOR made out of 50 x 50 x 6 mm M.S angle for outer frame,35 X 35 X 5mm M.S.Angle for outer frame of shutter. The entire shutter area shall be covered with CRC sheets (18 G) with 5Nos, of stiffners using M.S.Flats of size 25 X 6mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash butt welding or any other suitable method. Provision towards 3Nos, of Hinges incase of single shutters / 6Nos,of Hinges incase of Double shutters of 125 X 31 X 1.25mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop 1No. The frame shall be provided with 6Nos,of Hold fast of 200mm length using 50 X 6mm M.S.Flat. The entire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemental officers.
23
-
-
Supplying and fixing MS grill to doors windows and ventilators etc. as directed by the departmental officers inclusive of cost of MS grill and labour charges including one coat of red oxide and fixing in position etc. complete
1534
-
-
Ceiling Plastering with cement mortar 1:3 mix (one cement three P-sand), 10mm thick in all floors for RCC slabs, Beams, Sunshades including packing, providing cement mortar beading for sunshades, staircase steps, landing slabs etc., as directed by the departmental officers etc., complete complying with standard specifications.
665
-
-
Plastering with cement mortar 1:5 mix (one cement five P-sand), 12mm thick in all floors using clean screened M-Sand and including cost of curing for fifteen days from the completion of the work and surface should free from undulations and including the cost of preparing the surface for plastering and protecting from other damages till setting of mortar etc., complete complying with standard specification.
1500
-
-
Weathering Course with Brick jelly lime concrete made in Broken Brick Jelly 20mm gauge in pure slaked lime (no M-Sand to be added) laid over roof slab, the proportion of brick jelly to lime being 32 to 12.5 and well beated with wooden beaters for giving required slope and thickness etc., complete complying with standard specification.
16
-
-
Finishing the top of the roof slab with one course of Machine pressed tiles of size 20cm x 20cm x 2cm of approved quality laid in cement mortar 1:3 [one cement and three M-Sand] 12mm thick mixed with waterproofing compound 2% by the weight of cement used and the top pointed with same mortar etc., complete complying with standard specification.
220
-
-
Plain Cement concrete in 1:8:16 [one cement, eight M-sand and sixteen course aggregates] using 20mm size Hard Broken/Machine crushed Granite Stone Jelly for dummy columns including dewatering if found necessary and laid in layers of not more than 15cm thick and compacted etc., complete complying with standard specification.
4
-
-
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
305
-
-
Painting two coats with ready mixed Plastic Emulsion paint (weather proof) of approved quality and colour over a priming coat, including thorough scraping, clean removal of dirt and including necessary plaster of paris, putty wherever required etc., complete as per standard specifications.
2451
-
-
Painting two coats for New iron work surface using best quality synthetic enamel paint etc., complete complying with standard specification.
29
-
-
Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of "U" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm]
34
-
-
Supplying and filling Well gravel in layers of not more than 15cm thick well rammed, watered and compacted etc., complete complying with standard specification.
90
-
-
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVCinsulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switchm with continuous earth wire connection of 14 SWGTC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). etc, complete as per standard specifications.SD23
69
-
-
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVCinsulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVCaccessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for SA 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWGTC wire and making good of the concealed portion with suitable colour for concealed PVC plug point.etc, complete as per standard specifications SD38
24
-
-
Supply and run of 2 of 1.5 sqmm (22/0.3) PVCinsulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWGTC wire and making good of the concealed portion with suitable colour.etc, complete as per standard specifications SD54
60
-
-
Supply and fixing of single box type 4'36 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting etc, complete as per standard specifications SD87
32
-
-
Supplying and fixing of 1200mm ( 48" ) sweep AC ceiling fan complete with regulator with 1Mdown rod including S & F of fan clamp with side plates and cross arm etc, complete as per standard specifications SD 107
32
-
-
Earthing as per P.W.D. standard with an earth electrode of 2Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessarymasonry work. etc, complete as per standard specflcatlons SD212
2
-
-
Supply and fixing of Horizontal type 4 way triple pole neutral MCBdistribution board in sheet steel enclosure with 40 A 4 pole MCBisolater as incoming and 12 Nos. 6A to 32 A SPMCBas outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBD Band MCB's should be with the 151 mark etc, complete as per standard specifications (SD-157)
5
-
-
Supply and run of 2 of No.8 SWGGI wire for guarding with cradle with NO.8SWGGI wire at the equal interval of l.5m etc, complete as per standard specifications SD.75
60
-
-
Supply and run of 4 X 6 sq.mm (84/0.3) PVCinsulated SCunsheathed Cu.Conductor of 1100V grade on 7/20 GI bearer wire for service connection mains etc, complete as per standard specifications.SD68
60
-
-
Doors and Windows including removal of frames, hinges and fastenings etc, complete.(W-0029)
57
-
-
Dismantling the existing damaged RCC Roof slab in Ground and First Floor clearing away from the site etc, complete.(W-0035)
56
-
-
Dismantling the existing damaged Brick work in cm in Ground and First Floor clearing away from the site etc, complete.(W-0015)
203
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%