Municipal Administration And Water Supply Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Municipal Administration And Water Supply Department - MAWS Tender
Civil And Construction
Building Construction
Eprocure
Opening Date27 Feb 2024
Closing Date4 Mar 2024
Tender Amount₹ 22,00,000
Costs
EMD
₹ 22,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAWS_430686_1Tender No
5197/E1/2023Tender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://https://www.tn.gov.in/maws/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Centering for soffits of RCC Slabs of plane surface like lintels, beams, etc., including strutting 3m high using mild steel sheets of size 90cm x 60cm x and B.G 10 stiffened with M.S angles of size 25mm x 25mm x 3mm laid over silver oak (C.w) joists of size 10cm x 6.5cm (spaced at about 90cm c/c) and supported by casurina props of 10cm to 13cm dia (spaced at 75cm c/c) complying with standard specification and directed - 10m² (P & D)
46
-
-
Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards.
3
-
-
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
3.76
-
-
Brickwork in CM 1:5 (One Cement & Five Crushed Stone Sand (M- Sand) using II class ground moulded bricks of size 9" X 43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT
8
-
-
Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
33
-
-
Weathering Course with concrete Broken Bricks Jelly 20mm Gauge in pure slaked lime (no sand to be added) over roof slab, the proporation of brick jelly to lime being 32 to 12.5 well beated with wooden beater for giving required slope and thickness as directed by the departmental officers etc., complete 10cum
15
-
-
Paving the top of roof with Solar refelective ceramic tiles of size 305mmx 305mmx 7mm of approved quality in cement mortar 1:3 12mm thick mixed with water proofing compound confirming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
203
-
-
Fabricating supplying and fixing of pre painted galvanium colour sheets with the following specification. The materials should be of PPGI tile profile with a red colour or any other approved design 0.47 mm thick 24 guage having width 1050 mm. The sheet should be G.I.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws,plastic washer.The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of Z 120 GSM paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. The sheet to be fixed with making suitable corrugated,cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers.
17
-
-
Solid PVC door shutters with frame using 19 guage 19mm Ms square tubes for styles and outer frame 15mm MS square tubes for top lock bottom rails. The steel square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutterrs using 5mm thicksolid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. the overall size of styles shall be 50mm x 30mm. the overall size of top rail, lock rail and bootom rail shall be 75mm x 30mm. the ovrall size of frames shall be 50mm x 45mm with suitable rebate for housing the shutters.
24
-
-
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
14
-
-
Supply and fixing of M.S Grills for Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
225
-
-
Supplying and fixing of UPVC (unplasticized polyvenyl chloride) windows of casement type opening from profole of outer frame 60mm x 58mm and shutter profile afre reinforced with GI/1mm 25gsm and 100 corrosion free the profile are multi chambered section with wall thick of 2mm the epdm rubber (black colour) covered with over all the edges of frameand shutter will be provided with spag multi power ponit locks and also it operates as handles the corners and joints to be welded and cleaned radiation free pin ended plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow the leakage of water even at most ranging of storms and should have key lockableaction security protected hingers strong locking system and as per noise and enenrgy loss
43
-
-
UPVC Ventilator
Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
11
-
-
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator)
84
-
-
Supply and fixing of single box type 4'36W fluorescent fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting
58
-
-
Supply and fixing of 1200mm (48") AC Ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp
30
-
-
Earting as per PWD standards with an earth electrode of 2mts class B GI pipe of dia 32mm complete with necessary masonry works
2
-
-
Supply and fixing of 3 phase 4 wire 4 way ICDB of 32A per way with 100A TPNMC switch with suitable trunking box MS cable entry boxes and internal connection on suitable angle iron frame work with earth connection
2
-
-
Supply and fixing of horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door (metal) with 40A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark
2
-
-
Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete
1
-
-
Supply and delivery of 7/20 GI service wire including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specification
140
-
-
Supply and delivery 32mm GI service pipe including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specification
4
-
-
Supply and fixing of fitting with guard suitable for 11W CFL lamp with CFL
12
-
-
Drilling of Borewells anywhere in Tamilnadu including transporation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles bouulders etc.,By first taking a pilot bore of 150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs fuel,labour and drilling bentonite and water required for drilling at site and including construction of mud pit etc.,complete
60
-
-
Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer
60
-
-
Supply and Delivery of unplasticised PVC Casing Pipes of the following diametre in 3 metres length with screwed and socket ends and centering guides for every 15m length of pipes as per IS 12812 / 92 and DN 4925 and as amended from time to time to suit deep borewells as above 250m depth for delivery at site including loading unloading freight transit and insurance etc.,complete.
-
-
-
Supply of 150mm Nominal dia (6") Deep borewell PVC Plain casing Pipes RS wall thickness of 13.0mm to 14.30mm at site of work
42
-
-
Supply of150mm nominal dia (6") deep bore well PVC ribbed Screen PVC casing pipes RS with suitable 1.00mm horizontal slot with having open areas
18
-
-
Supply of 150mm dia OD PVC End cap as per special specification.
1
-
-
supply and delivery of32 mm upvc Column pipe As per Es 4984/1995
60
-
-
Conducting electrical logging (including conveyance charges and as directed by the TWAD Board officers)
1
-
-
Earthwork excavation for foundation in all soils and to the full depth as may be directed except hard rock not requiring blasting inclusive or shoring, shuttering and bailing of water wherever necessary refilling the sides of foundation with excavated earth in layers of 15cm thick well rammed and compacted deposition the surplus earth in places shown by Departmental Officers with initial lead of 10 Meters and lift of 2 meters and lift of 2 meters and clearing leveling the site etc., complete.For Pipe line Cutting
2
-
-
Supplying and filling of sand in foundation and basement including watering and ramming to consolidation etc., complete as per standard specification.
0.8
-
-
Cement concrete 1:4:8 mix (one cement four sand eight aggregate) using 40mm ISS gauge HBG metal for foundation including cost and conveyance of all materials and all labour charges for mixing, laying, ramming, curing concrete etc., complete as per standard specification.
0.8
-
-
Brickwork in cement mortar 1:5 (one cement / five sand) mix using II class Ground moulded chamber burnt bricks of size 9" x 4-1/2" x 3" including all cost and conveyance of all materials as per standard specification.
3.2
-
-
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2
0.5
-
-
Reinforced Cement concrete 1:1.5 :3 (one cement, one and half sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete.
0.2
-
-
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
15
-
-
Plastering with cement mortar 1:5,12 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
12
-
-
Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
12
-
-
Supply and Delivery of of Submersible Motor Pump Set 1HP with Duty Condition of 15 LPM and 80 m Head with ISI Make Suitable for150 mm Size Bore Well as per IS 8034 Specification.etc., Complete
1
-
-
Supply and Delivery of PVC Insulated and Sheathed 3 core flat type 2.5 Sq mm Copper flat Submerciple Cable As per Special Specification
60
-
-
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depthand also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
1
-
-
Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by ‘V’ notch method.
4
-
-
Supply and delivery and fixing of 1000 litre capacity HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.
1
-
-
Supply , delivery and fixing of following pipes and specials including all labour charges as per Standard Specification.
-
-
-
32mm G I Bend
3
-
-
32mm G I Coupling
3
-
-
32mm G I Elbow
3
-
-
32mm G I Union
3
-
-
20mm Gi Tap
3
-
-
Female Threaded Coupler
4
-
-
Male Threaded Adapter
4
-
-
32mm UPVC Pipe
36
-
-
Nylon Rope
60
-
-
90mm PVC Pipe
75
-
-
Supply and run of 2 of 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade on 7/20 GI bearer wire for service connection mains
8
-
-
Supply and run of 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains
3
-
-
Supply , delivery and fixing of following pipes and specials including all labour charges as per Standard Specification.
-
-
-
32mm Gi Pipe
8
-
-
25mm Pvc Pipe
2
-
-
Supply and delivery of MS Kiosk of size
0.75m x 0.45m x 0.75m made up of MS
angle of size 50mm x 50mmx 4mm alround covered with 16 gauge MS sheet and kiosk door made up of MS plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements and labour charges etc.,
1
-
-
Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1" x 1/8" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit
1
-
-
Supply and delivery of Single phase Panel Board direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/single Phase/50HZ(± 5%) and 230 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button
switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements