Municipal Administration And Water Supply Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Municipal Administration And Water Supply Department - MAWS Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date4 Oct 2024
Closing Date21 Oct 2024
Tender Amount₹ 10,58,00,000
Costs
EMD
₹ 10,58,000Document Cost
₹ 10,000Tender Fee
₹ 10,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAWS_490795_1Bid Award Id
ViewTender No
1890/24/E1- Bus standTender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://https://www.tn.gov.in/maws/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and providing Anti termite pre construction treatment using aldrin or dealdrin or heptochlor as per relavent IS 6313 (part II) code including cost of all materials, labour, hore charges for T&P etc complete.
3270
-
-
Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
414.49
-
-
Plain Cement Concrete 1:4:8 (one cement, four sand and eight hard broken stone jelly) using 40mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
437
-
-
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
-
-
-
Footing ,Plinth Beam and Drain Centring
5300.5
-
-
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC M20 concrete using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed.50mm thick slab (using 20mm HBGS Jelly)
613
-
-
Supplying and fixing GI DRAINAGE SPOUTS 100mm dia as per GOI drawing SD/205 with grating arrangements at top as shown in the drawing and 100mm dia drainage spout projecting atleast 300mm beyond the bottom of deck slab as shown in the drawing, including cost and conveyance of Galvanised iron pipes and flats and fixing them in position,etc., complete as per cl 2705 of MORT&H specification. (V Revision)
140
-
-
Reinforced Cement concrete 1:2 :4 (one cement, two sand & four course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete.
223
-
-
Plain Cement Concrete 1:2:4 (one cement, four sand and eight hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
385
-
-
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
-
-
-
For Roof Slab
4695
-
-
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
2851.6
-
-
For plane surfaces such as Circular RCC columns
93
-
-
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
-
-
-
FOOTING ,PLINTH BEAM
772
-
-
Ground Floor
316
-
-
First Floor
381
-
-
Supplying, fabricating and placing in position Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
196500
-
-
Brick work in Cement Mortor 1:5 using ii class ground moulded chamber bricks of size 9"x43/8"x23/4" for foundation and basement including curing etc.,complete complying with standard specification
-
-
-
upto basement
38
-
-
Ground Floor
584
-
-
First Floor
51
-
-
Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
1910
-
-
Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement G27
105
-
-
Paving the floor with design Rajasthan kotta tiles (colour and shade as directed) of size 610 mm x 610mm x 20mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement etc, complete as per standard specification
1453
-
-
Supplying and fixing of rolling shutters shall be pull and push type (Gear operated) made of 18G/3" lathe sections which consist of five main parts such as curtain, lock plate, guide channels rollers and hood cover. These five main parts are made out of special components detailed below: curtain shall be of 18G/3" lath sections cut to required size and filled with heavy cast iron / MS clips. For 8'0"(2.45m) high rolling shutter lath sections provided shall be not less than 37 numbers. Lock plate shall be 10GMS sheet and attached to the side brackets with 20mm square bar.Side brackets shall be of 10G MS plate and cast iron "U" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty "C" class 40mm steel pipe and high tensile high carbon coil springs. 2 springs shall be supplied. Side brackets shall be of 10G MS plate and cast iron "U" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty "C" class 40mm steel pipe and high tensile high arbon coil springs - 2 springs shall be supplied. Hood cover shall be of 0.8mm CRCA sheet reinforced with 25mmx25mmx3mm MS angle or gate channel. The rolling shutter in addition to the above should have pulling hook and shall be coated on exposed area with heavy coat of red oxide primer etc., complete.
381
-
-
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
3265
-
-
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
262
-
-
Special Ceiling Plastering with cement mortar 1:3,10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
3108
-
-
Plastering with Cement Mortar 1:5 (One cement and Five Crushed stone sand ), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
7632.99
-
-
Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., complete complying with standard specification.
10753
-
-
Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors.
381
-
-
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
20
-
-
Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification
57052
-
-
Fabricating supplying and fixing of pre painted galvanized iron sheets with the following specification. The materials should be of PPGI tile profile with a red colour or any other approved design 0.47 mm thick 24 guage having width 1050 mm. The sheet should be G.I.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws,plastic washer.The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of Z 120 GSM paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. The sheet to be fixed with making suitable corrugated,cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers.
1463
-
-
Providing and laying, spreading and compacting graded stone aggregate to Wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications.
147
-
-
Supplying and laying Rubberised interlocking Paver block M40 grade Providing and laying of 83mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub base, stone dust cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
1463
-
-
Supplying and fixing of M.S grill of approved design for doors, windows and ventilators using necessary mild steel flats for inner and outer memebers which should be fixed to window frames inclusive of priming coat of best approved quality red oxide primer etc., complete complying with standard specifications.
863
-
-
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.
24
-
-
Construction of Inspection chambers of following sizes with earth work excavation for foundations, C.C 1:4:8 using 40mm HBGS jelly for foundation and brick work in CM 1:5 using country bricks 9" x 4 3/8" x 2 3/4 ", inside plastering with CM 1:3 12mm thick, inside channeling with brick work, outside plastering with C.M 1:3 20mm thick, R.C.C precast cover slab 75mm thick using M20using 20mm blue granite jelly with necessary reinforcement etc complete as directed by the departmental officers
6
-
-
Supply and fixing of Tensile Fabric Structure with wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers.
614
-
-
Electrical Work-2024-2025
-
-
-
Supply and fixing 16amps DP switch with metal clad(side handle) of 500 V with F & N on suitable teak wood Board of size 30cmx20cmx6 cm including necessary internal conection,earth connection etc.,complete (SD 142)
56
-
-
Earthing as per ISI Specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangement using charcoat, common salt, G.I.reducer, checj nuts etc., and mansonry workand providing RCC cover slab 38mm thick for the Brick mansory including cost of steel and fabrication of reinforcement etc., complete in all respectes as directed by the departmental officers. (SD 233)
2
-
-
Supplying and run off 8 SWG GI wire on walls or below ground level with necessary 'U' nails, earth work excavation and refilling & including the cost of all materials etc., complete in all respects as directed by the departmental officers.(SD 75)
105
-
-
Supply and fixing of 20 Amp DP Plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For A.C Plug) (Legrand (MDS/Hager (L & T make) SD 140
76
-
-
Supplying and fixing MCB isolator 32A TP with earth connection (Legrand (MDS/Hager (L & T make) P.No :32
2
-
-
Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch, PVC junction box, 16gauge MS switch box 100mm x 100mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point. (SD 18)
76
-
-
Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch, PVC junction box, 16gauge MS switch box 300mm x 200mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point. (SD 19)
76
-
-
Wiring with 2x1.5sqmm PVC insulated SC unsheated CU conductor of 1100 V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall for 5 AMPS 3 PIN C.S. PLUG POINT AT CONVENIENT PLACES including the cost of cable, PVC pipes and specials, brass screws, flush type 5 amps 3 Pin C.S. plug, 16 gauge Msjoint box, 16 gauge MS switch box covered by laminated hylem sheet 3mm thick, cement, labour and making good of the concealed portion with suitable colour for open plug point. (SD 10)
76
-
-
Supply and run off 2 of 1.50sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 55)
350
-
-
Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 57)
350
-
-
Supplying and fixing of 1200 mm (48") AC ceiling fan complete with stepped electronic 300 W regulator with 1 m down rod with fan clamp, side plates and cross arm of size departmental officers. (SD 106)(18") etc., complete as directed by the (SD 107)
76
-
-
Supply and fixing of 20W 4 Feet LED Fitting with LED Inluding cost of materials, loading and unloading charges etc., Complete
100
-
-
Supply and fixing of 6 Metre Length Single Bracket Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length Inluding cost of materials, loading and unloading charges etc., Complete. Page no 159, M-2118
30
-
-
Supply and fixing of 18W LED 3000K Round type resessed fittng (Philips/Havells) complete with T.W round blocks on wall or ceiling with flu tube with PVC unsheather copper leads from terminals to the filling Inluding cost of materials, loading and unloading charges etc., Complete. page 121, M1285
100
-
-
Supply and fixing of TNEB meter Board suitable for 32 A Three phase service connection with 32A fuse unit(500V)32A neutral link and earth link (1" x 1/8" Copper flat) on T.W plank of size 600mm x450mm x 19mm with supportingT.W.reepers of 1" thick oneither sider with painting withsuitable bolt and nuts for fixingthe TW plank on wall withearth connection and interconnection with 7/20 PVCinsulated copper wire from EBmeter to fuse unit. SD 127)
1
-
-
Supplying and fixing 63 A TPNMC switch on suitable angle iron frame work with MS cable entry boxes with earth connection only. (SD 166)
3
-
-
Supply and run off 2 of 4sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 57)
120
-
-
Supplying and run off 2 of 4 sqwmm (56/0.3) PVC insulated SC unsheatherd cu.conductor of 100 V grade on 7/20 GI bearer wire service connection mains (SD 65)
120
-
-
Supply and run of 2 of 4 sqmm (56/0.30) PVC insulated SC unsheathed cu.conductor of 1100 V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for main.(SD 70 )
120
-
-
Supplying and fixing of 3 nos. of 100A porcelain fuse units 500 Volt of approved brand having ISI mark in T.W Board of suitable size etc., completed. Page no 126, M1394
15
-
-
Supply and fixing of 32A fuse units on suitable TW board with necessary internal connections for controlling the power plug Inluding cost of materials, loading and unloading charges etc., Complete. Page 126, M1392
1
-
-
RO-Reverse Osmosis
-
-
-
Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to
deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No.
(b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos.
(f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary
CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact. (250 Litres).Page 77, M-0719
3
-
-
Highmass Light
-
-
-
Supplying and erectingof 16 Mtrs. High Mast Tower Polygonal Shapes. Suitable for 12 luminaries for Wind Speed up to 180 Km/hr. As per IS -875 Parts -3 Material Cons.: BSEN 10025 # Mechanical Components including Head Frame & Pulley Assay, Winch Bracket, Lantern Carriage Ring, Luminaries and C.G Box Mtg. Arms, Resting Bracket Guide Ring, Compensating Disc, Lightening Arrestor.etc. ( Each Set ) # Wire Rope, Safety Wire Rope, D Suckle Clamps, Nuts and Bolts. # Cable with termination & distribution box. # Foundation A0.45essories. # Winch Assembly # Power tool. Mast bottom Dia:415 mm. Top : 150 mm, Thk: 4,3,3 mm. Motor-1.Feeder pillar box comprising 100 ams fuse unit 24 hours timer 1-nos and contactor 1-nos outgoing MCB toggle switch and neutral link with internal wiring made of MS sheet and vermin proof.Erection and commissioning of 16 Mtr high mast on the above said concrete foundation using suitable equipments. Fixing of flood light luminaries in the lantern carriage including internal wiring & using flexible copper cable complete. LED fittings light 150/W 8 nos
2
-
-
Genset
-
-
-
Supply errection and commisioning of 62.5 KV Genset of diesel capacity 50liter and automatic type of ISI Make including cost of concrete bed , errection and all other cost and conveyance etc complete. As per PWD SOR 2021-22 P.No.146 S.No.9(h)
1
-
-
FIRE FIGHTING
-
-
-
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. (Q)
10
-
-
Supply and fixing of Water CO2 Stored Pressure Type 4.5Kg capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers
10
-
-
CCTV Arrangement
-
-
-
Supply fixing and errection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per Specification
-
-
-
CCTV Camera (Q)
15
-
-
Network Video Recorder (32 CHANNEL-2 SATA) Pg:154 Sn:34,d.M-2198.M-2221
1
-
-
Hard disc for NVR 4TB Pg:155, Sn:38,b.M-2201
1
-
-
24 Port Patch Panel Pg:155, Sn:40,e.M-2290
1
-
-
Rack With Accesssories -42 U RACK Pn:155, Sn:39,g.
1
-
-
Armoured LAN & CCTV Cable (CAT-6) Pn:162, Sn:31,b.
300
-
-
Led tv for display (Q) 42" LED TV
1
-
-
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements