Municipal Administration And Water Supply Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Municipal Administration And Water Supply Department - MAWS Tender
Eprocure
Opening Date29 Nov 2024
Closing Date13 Dec 2024
Tender Amount₹ 13,66,307
Costs
EMD
₹ 13,663Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAWS_505653_1Tender No
E7 / Est.No. 702 / 2024 -25Tender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://https://www.tn.gov.in/maws/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply and delivery of DI D/F Gate valves (soft seated) resilient seated soft sealing gate valves (sluice valves) with body bonnet of ductile cast iron of grade GGG 40/45/50, or equivalent grade wedge fully rubber lined with EPDM, replaceable spindle nut, without gland packing and with 3 O-Ring protectionon the shaft and seals of NBR and the valves should be of vaccum tight and 100% leak proof with face to face dimensions as EPR BS 5163 - 89/ ISI 14846 - 2000/ DIN 3202 F 4. All the valves should be with electrostatic powder COATING BOTH INSIDE AND OUTSIDE WITH POCKET LESS STRAIGHT THRO' BODY PASSAGE. aLL THE VALVES ARE TO BE COMPATIBLE FOR BURRIED APPLICATION WITH PRESSURE RATING pn 10/16.150mm dia. DI D/F Gate Valves Twad P-75
1
-
-
Supply and delivery of 22.0 Submersible centrifugal sewag non -clog pumps Twad P-134 above 10m upto 15m head Discharge 100 to 200 M3/hour
1
-
-
UN PLASTICIZED PVC PIPES FOR PORTABLE WATER SUPPLY AS PER IS 16647/2017 Twad P-28 160mm dia.
115
-
-
Laying and jointing PVC slitted pipes in the inflitration gallery excluding cost of pipes but including charges for special tools and plants etc.. Complete such as air compressor and helmet Twad P-236 160mm dia.
15
-
-
Refilling the trench with excavated earth in layer 25cm thick well rammed including watering consolidation etc., complete TWAD P No:268
121.89
-
-
Providing and laying ,spreading and compacting 0.396m3 of 45-22.40mm & 0.528m3 of 22.40-2.36mm & 0.396m3 of 2.36mm and below metal graded stone aggregate to wet mix macadam (WMM ) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications. Road Data P.No:15
4.05
-
-
Supplying and filling in foundation and basement with Quarry Dust in layers of 15cm thick well rammed and consolidation including watering complying with std. specification . Building Data P.No:27
0.1
-
-
Plain Cement Concrete 1:4:8(one cement five four Sand and Eight aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification Building Data P.No:40
0.1
-
-
Brick work in cm 1:5 (one cement five sand ) using 2nd class bricks in G.F Building Data P.No:40
0.5
-
-
Plastering with c.m 1:3 (One Cement three sand) 20mm thick. Building Data P.No:45
0.4
-
-
Plastering with c.m 1:5 (One Cement three sand) 12mm thick. Building Data P.No:46
3.3
-
-
Supply and delivery of PVC insulated and sheathed 4 sq.m copper cable conforming to IS 694/1990 suitable for submersible pump set.. TWAD DATA P.NO:214
15
-
-
Labour charges for over head wiring from EB pole to pump room by fixing 32mm dia GI pipe to the required height over roof slap of pump room ads directed by EB authorities including fixing copper wire in four layers and inslulated with proper reels wire required MS clampset supp delivery and fixing of all materials such as bore well cover clamp set U kondi 7/20GI wire insulated reels 24 18 TW meter board 10x4 aorial board PVC Tape roll copperd earth plate GI bolt and nut with washer nutral linkPVC insulted copper wire (7/20 wire up to 10 HPm 7/16 wire above 10hp)1”PVC hose pipe 1” PVC clamp 25mm PVC encacing pipe 332AMPS fuse carroar 6no 10HP and 60 amps fuse carrier.
1
-
-
ConstructionofRCCmachineholeusingsulphateresistantcementwithM30designmixconcreteusingCrushedstonesand(Msand)includingearthworkexcavationasperSS20B,providingpointedgetowellkerbusingISA150x75x10mmweighingat16.9kg/m,sinkingwellkerbbelow2mfromG.L.orbyopenexcavationforvariousdepthaspersiteconditionwithM30mixforsidewall,raftandroofslab,includingcostofsteelreinforcement,includingbailingandpumpingoutwater,formwork,pluggingthebottomwithPCC1:3:6using40mmhardbrokengranitejelly,layingplaincementconcrete1:3:6using12mmto20mmhardbrokengranitejellyforfixingframe,fixingFRCmachineholecoverandframe,providingCIsteps,,benchingandchannellingincludingrefillingthetrencheswithexcavatedearthanddisposalofearthetc.Includingtestingthemachineholewithwaterfor48hourstocheckwatertightnessandrectifyingthedefectsifanycompleteforthefollowing size of machineholes.
1
-
-
Add GST 18%
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%