Municipal Administration And Water Supply Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Municipal Administration And Water Supply Department - MAWS Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date3 Aug 2024
Closing Date16 Aug 2024
Tender Amount₹ 46,00,000
Costs
EMD
₹ 46,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAWS_469268_1Bid Award Id
ViewTender No
1750/2024/E1Tender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://https://www.tn.gov.in/maws/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
10
-
-
Plain Cement Concrete 1:4:8 (one cement, four sand and eight hard broken stone jelly) using 40mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
10
-
-
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
94
-
-
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
232
-
-
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
142
-
-
Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. Up to Basement
43
-
-
Ground Floor
32
-
-
Up to First Floor
4
-
-
Supplying, fabricating and placing in position Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
8000
-
-
Brick work in Cement Mortor 1:5 using ii class ground moulded chamber bricks of size 9"x43/8"x23/4" for foundation and basement including curing etc.,complete complying with standard specification Up to Ground Level
13
-
-
Ground Floor
35
-
-
First floor
17
-
-
Paving the floor with kota stone slab of size 600 x 600 of 18 / 20mm (un-polished) in all floors laid in of cement mortor 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. The kota stone slabs and other materials to be used shall be got approved by the MUNICIPAL ENGINEER concerned before use on work, etc., complete as per standard speicification.
48
-
-
Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
65
-
-
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
126
-
-
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
11
-
-
Special Ceiling Plastering with cement mortar 1:3,10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
107
-
-
Plastering with Cement Mortar 1:5 (One cement and Five Crushed stone sand ), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
428
-
-
Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., complete complying with standard specification.
543
-
-
Supplying and fixing in position best quality P.V.C soil/ waste pipes (6KSC) of various sizes having ISI mark and providing leakproof joints including fixing to the wall with P.V.C/ M.S clamps etc., and making connection to all sanitary fittings, dismandling masonry/R.C.C. works wherever necessary and making good the dismandled portion to the original condition, complying with standard specifications.(D) 110mm dia pipe
12
-
-
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re- doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the MUNICIPAL ENGINEER before use on works).(D) 110mm dia PVC Elbow
6
-
-
110mm dia PVC Elbow with Door
6
-
-
110mm dia PVC Tee
6
-
-
110mm dia PVC Tee with Single Door
6
-
-
Electrical Data for the year 2023-24 Supply and fixing 16amps DP switch with metal clad(side handle) of 500 V with F & N on suitable teak wood Board of size 30cmx20cmx6 cm including necessary internal conection,earth connection etc.,complete (SD 142)
1
-
-
Earthing as per ISI Specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangement using charcoat, common salt, G.I.reducer, checj nuts etc., and mansonry workand providing RCC cover slab 38mm thick for the Brick mansory including cost of steel and fabrication of reinforcement etc., complete in all respectes as directed by the departmental officers. (SD 233)
1
-
-
Supplying and run off 8 SWG GI wire on walls or below ground level with necessary 'U' nails, earth work excavation and refilling & including the cost of all materials etc., complete in all respects as directed by the departmental officers.(SD 75)
30
-
-
Supplying and fixing of 4 way Single phase DB of 16amps/way with 16amps DP switch with metal glad of 500 volt(side handle) with Fuse and Neutral of suitable T.W. Board of size 40cm x30cmx6.3cm with earth connection etc., complete in all respects as directed by the departemental officers (SD 153)
1
-
-
Supplying and fixing of 8 way single phase DB of 16amps/way with 16amps DP switch with metal glad of 500 volt(side handle) with Fuse and Neutral of suitable T.W. Board of size 40cm x30cmx6.3cm with earth connection etc., complete in all respects as directed by the departemental officers (SD 152)
1
-
-
Supplying and fixing of 5 A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet (SD 135)
10
-
-
Supplying and fixing of 5 A /15A 3 pin flush type wall socket with15A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet including cost of wall socket, switch and labour charges fo wall cutting, grouting, flushing and making good, painting with primary and finishing coat for MS box etc., complete as directed by the departmental officers. (SD 138)
10
-
-
Supply and fixing of 20 Amp DP Plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For A.C Plug) (Legrand (MDS/Hager (L & T make) SD 140
10
-
-
Supplying and fixing MCB isolator 32A TP with earth connection (Legrand (MDS/Hager (L & T make) P.No :32
2
-
-
Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch, PVC junction box, 16gauge MS switch box 100mm x 100mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point. (SD 18)
13
-
-
Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch, PVC junction box, 16gauge MS switch box 300mm x 200mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point. (SD 19)
13
-
-
Wiring with 2x1.5sqmm PVC insulated SC unsheated CU conductor of 1100 V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall for 5 AMPS 3 PIN C.S. PLUG POINT AT CONVENIENT PLACES including the cost of cable, PVC pipes and specials, brass screws, flush type 5 amps 3 Pin C.S. plug, 16 gauge Msjoint box, 16 gauge MS switch box covered by laminated hylem sheet 3mm thick, cement, labour and making good of the concealed portion with suitable colour for open plug point. (SD 10)
13
-
-
Supply and run off 2 of 1.50sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 55)
50
-
-
Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 57)
50
-
-
Wiring with 3x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch, PVC junction box, 16gauge MS switch box 100mm x 100mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC staircase light point.(SD 28)
2
-
-
Supplying and fixing of 1200 mm (48") AC ceiling fan complete with stepped electronic 300 W regulator with 1 m down rod with fan clamp, side plates and cross arm of size departmental officers. (SD 106)(18") etc., complete as directed by the (SD 107)
10
-
-
Supply and fixing of 20W 4 Feet LED Fitting with LED Inluding cost of materials, loading and unloading charges etc., Complete
13
-
-
Supply and fixing of 60W LED Street Light Fitting with LED (Philips/Havells) Inluding cost of materials, loading and unloading charges etc., Complete
1
-
-
Supply and fixing of 18W LED 3000K Round type resessed fittng (Philips/Havells) complete with T.W round blocks on wall or ceiling with flu tube with PVC unsheather copper leads from terminals to the filling Inluding cost of materials, loading and unloading charges etc., Complete
1
-
-
Supply and fixing of TNEB meter Board suitable for 32 A Three phase service connection with 32A fuse unit(500V)32A neutral link and earth link (1" x 1/8" Copper flat) on T.W plank of size 600mm x450mm x 19mm with supportingT.W.reepers of 1" thick oneither sider with painting withsuitable bolt and nuts for fixingthe TW plank on wall withearth connection and interconnection with 7/20 PVCinsulated copper wire from EBmeter to fuse unit. SD 127)
1
-
-
Supplying and fixing 63 A TPNMC switch on suitable angle iron frame work with MS cable entry boxes with earth connection only. (SD 166)
1
-
-
Supply and run off 2 of 4sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 57)
20
-
-
Supplying and run off 2 of 4 sqwmm (56/0.3) PVC insulated SC unsheatherd cu.conductor of 100 V grade on 7/20 GI bearer wire service connection mains (SD 65)
20
-
-
Supply and run of 2 of 4 sqmm (56/0.30) PVC insulated SC unsheathed cu.conductor of 1100 V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for main.(SD 70 )
20
-
-
Supplying and fixing of 3 nos. of 100A porcelain fuse units 500 Volt of approved brand having ISI mark in T.W Board of suitable size etc., completed
1
-
-
Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15 A 3 pin non inter locking CS plug with continuous earth wire connection with 1.5 sqmm PVC unsheadthed Cu. cable and making good of the concealed portion, with suitable colour for concealed power plug point (SD 40)
20
-
-
Supply and fixing of 32A fuse units on suitable TW board with necessary internal connections for controlling the power plug Inluding cost of materials, loading and unloading charges etc., Complete
2
-
-
Supplying and run off 4of 4 sqwmm (56/0.3) PVC insulated SC unsheatherd cu.conductor of 100 V grade on 7/20 G.I bearer wire service connection mains (SD 67)
20
-
-
Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall with continuous earth wire connection of 14 SWG TC wire and making good for the concealed portion with suitable colour. (SD-57)
20
-
-
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers.
2
-
-
Supply and delivery of First Aid Box complete with all First Aid Medicines all Including all charges etc., complete
2
-
-
Supply and delivery 4 Nos of Fire Buckets made out of 40x40x6mm MS Angle Including all charges etc., complete
2
-
-
Supply and fixing of Water CO2 Stored Pressure Type 4.5Kg capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers
2
-
-
ROLLING SHUTTERS (WITH ISI MONOGRAM) Supplying and erecting pull and push type rolling shutter with I.S.I make of approved size and section using 18 G.I sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of Hood covers, transportation charges etc(GEAR operated type from 8sq.m. to 12 sq.m area)
33
-
-
Evaluation Notes How It Works ?