Municipal Administration And Water Supply Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Municipal Administration And Water Supply Department Tender
Civil And Construction
Building Construction
Eprocure
Opening Date9 Nov 2024
Closing Date20 Nov 2024
Tender Amount₹ 11,00,000
Costs
EMD
₹ 11,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAWS_499895_1Bid Award Id
ViewTender No
10836/2024/MCE1Tender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and filling in foundation and basement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
6
-
-
Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
6
-
-
Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
18.14
-
-
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38
-
-
-
For plane surfaces such as RCC floor slab ,roof slab,beams,lintels,bed blocks,landing slab,waist slab,portico slab and beams,etc.
16
-
-
For plain surfaces such as rectangular or squareRCC columns,sunshades,top and bottom slab of RCC boxing,etc
96
-
-
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
15
-
-
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
1700
-
-
Brickwork in Cement Mortor 1:5 (One cement five sand) mix using country burnt of standard size 8 3/4"x4 1/4"x2 1/4" including cost and conveyance of all materials and labour etc complete as per standard specifications upto basement.
21
-
-
Supplying and fixing M.S. Grills to doors and windows and ventilators using M.S. flat of size 20x6 mm for outer member 12x 6mm for inner member which should be fixed to frames as directed by the departmental officers including cost of providing one coat of best quality red - oxide primer etc., Complete (The designs of M.S. grills should be got approved from departmental officers before their use in execution)
220.1
-
-
Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
38.33
-
-
Plastering with Cement Mortar 1:5 (One cement and Five sand),12 mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
200
-
-
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
3
-
-
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
31
-
-
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
33
-
-
Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement
5
-
-
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
0.99
-
-
Painting two coat over new iron grill work using synthetic enamel paint of approved quality and colour including cost and conveyance of all materials and labour etc., complete as per standard specifications
13
-
-
Supplying and fixing of WT Bulk Head fitting with guard Philips/Bajaj/Crompton/K.Lite)suitable for incandescent lamp with 60W bulb S.D 81
3
-
-
Wiring with 2 x 1.5 sqmm PVC unsheathed SC alu. Cable of 1100 V Grade in suitable PVC rigid pipe in wall and ceiling with PVC accessaries and T.W. Switch box with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC Light point.S.D 21
5
-
-
Wiring with 2 x12.5 sqmm PVC unsheathed SC alu. Cable of 650 V Grade in suitable PVC rigid pipe in wall and ceiling with PVC accessaries with suitable Teak wood box to house the control switch and regulator with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC Plug point etc., complete as per standard specifications.
10
-
-
Supply and run of 2 of 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains SD 58
20
-
-
Supplying and fixing of 20mm dia PVC Pipe etc., complete as per standard specifications.
20
-
-
Supply and fixing of single box type 4'40W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting
3
-
-
Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp