Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair/replacement Of Lt Ug Cables And Other Connected Works At Tech Area Cvrde Avadi. in Tiruvallur, Tamil Nadu, with an estimated contract value of Rs. 9,50,000. The bid opening date for this tender is 03-09-2019 and the last date for bid submission is 19-09-2019. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender
Opening Date3 Sep 2019
Closing Date19 Sep 2019
Tender Amount₹ 9,50,000
Costs
EMD
₹ 19,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_279300_1Bid Award Id
ViewTender No
8242Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
16 sq mm 4 core
100
-
-
... More
M&L for providing 'M' Seal straight through joining kit including materials all as required for LT cable size 95 to 150 sqmm 3.5 core all as specified and directed.
2
-
-
... More
Cutting of road to a width of 30cm and depth not exceeding 90cm for laying of protection pipe / cable including returning and filling, spreading levelling, watering and well ramming in layers and making good with PCC 1:2:4 type B1 for top 100mm thick complete all as specified and directed.
30
-
-
... More
120 sq mm 3.5 core
50
-
-
... More
Re-Laying only old serviceable LT/HT under ground PVC/XLPE cable any grade and any size in trenches/fixed to wall/pole/roff/laid in floor including necessary connections and thimbling complete all as specified and as directed by Engineer-in-Charge.
(Excavation, earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item).
150
-
-
... More
Supply and laying GI pipe “light Grade” in trenches/under floors or roads or along the pole incl clamp with suitable nuts & bolts for protection of cables for the following size :-
-
-
-
... More
50 mm bore
30
-
-
... More
M&L Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete for stays foundation and platform for transformer installation complete all as specified and directed.
2.5
-
-
... More
Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 2.5 Mtr above the starting point all as specified and directed.
96
-
-
... More
Relaying only old bricks sub class 'B' bricks (Old size) received from item No 08 & 09 for cable protection cover, laid flat and dry in trenches over the cable, perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge
1500
-
-
... More
M&L Plain cement concrete 1:3:6, Type C1 by using 20 mm graded granite stone aggregate in coping including necessary form work and finishing exposed surfaces fair & even complete all as specified and as directed.
0.5
-
-
... More
80 mm bore
30
-
-
... More
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms of soil complete all as specified and directed.
80
-
-
... More
25 sq mm 3.5 core
100
-
-
... More
M&L Plain cement concrete 1:4:8, type D2 by using 40mm graded stone aggregate as in foundation of poles, filling and mass concrete, complete all as specified and directed.
0.5
-
-
... More
All as per item No 11 herein before but of size above 25 sqmm but up to 70 sqmm, 3.5/4 core all as specified and directed.
2
-
-
... More
Disconnecting and removing the old U/S time switch supply and fixing of new time switch, 230 Volts, 50 HZ digital type and electrical connections suitable for the street light control all as specified and directed.
4
-
-
... More
Taking down Old UNSV RCC Pole and S&F new Steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with mild steel base plate, finial taper, plug, bolts, nuts and screw including two coat of aluminium painting over a coat of red oxide primer for exposed surfaces and two coats of bituminous black paint over a coat of concrete, including two runs of PVC insulated copper wire 2.5sqmm three core from the junction box to the fittings complete all as specified.
4
-
-
... More
95 sq mm 3.5 core
70
-
-
... More
50 sq mm 3.5 core
100
-
-
... More
Dismantling, removing the old U/s contactor, supply and fixing of ML 6 contactor three phase, 415 Volts 50 HZ including making electrical connections.
4
-
-
... More
Supply and laying XLPE LT Cable of the following sizes of any core, 1100 Volt grade heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. Make of cable :- Finolex/Rallison/Havells/Plaza/CCI/Universal cable
Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
-
-
-
... More
150 sq mm 3.5 core
150
-
-
... More
Supply and spread sand for sand cushioning of cables in trenches all as specified in MES Schedule Part-I and all as directed. Note: Punned thickness only will be measured and paid.
82
-
-
... More
40 mm bore
30
-
-
... More
Taking out old under ground LT XLPE/PVC cable of any size for found out fault from trenches/wall/roof/road/pipe/pole/DB including taking out of brick layer and segregation/staking of serviceable brick from trenches for reuse and broken brick bats removing from site complete all as specified and as directed by Engineer-in-Charge.
(Excavation, earth work shall be measured and paid for separately under appropriate item).
870
-
-
... More
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5M depth in hard/dense soil for laying of cable, pipes etc and getting out incl making good the excavated portion of the road/hardstanding etc by filling PCC to match with the existing level of the surface all as specified and directed.
176
-
-
... More
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
6260
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements