Military Engineer Services Tender

... More
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 May 2025
Closing Soon24 May 2025
Tender Amount₹ 49,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender Documents contains NIT, instructions for tender, specials conditions and particular specification
Bill of Quantities
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Ball Bearing 6311/C3

4

-

-

... More
80mm nominal bore

5

-

-

... More
Gasket of suitable size for the compressor existing at site

4

-

-

... More
Pulley V Belt SPB-1800/existing at site

10

-

-

... More
M&L for preparing old distempered and painted surfaces of walls by washing, rubbing down and stopping of surfaces and applying one coat of distemper oil emulsion (as approved tint) complete all as specified and as directed

270

-

-

... More
S&F LED Flood Light fittings 80 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaries with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories with existing high-mast/building/pole light fitting in and including reqd three core copper conductor complete taking out existing UNSV old one complete all as specified and as directed. Make: Bajaj- BJFL 80W LED/ Crompton Cat No.LFL-80-CDL/60-M/ Eveready Cat No.LEDFL080I5-04L or equivalent make as listed in PS.

25

-

-

... More
150mm outer dia

1

-

-

... More
50mm outer dia

2

-

-

... More
Material and labour for pin point the fault by arranging fault locating machine in any size of LT UG cable from any location/position/situation, taking down/out the faulty portion of cable, of any length from trenches, jointing with cable jointing kit & testing for satisfactorily serviceable with & including necessary excavation and earth work, sand cushioning and making necessary connections to make it functional complete all as specified and as directed. Note :- (I) Cable jointing kit shall be measured and paid separately. (ii) Old retrieved bricks/cable cover shall be reused (iii) The rates quoted includes excavation & earth work with sand cushioning.

20

-

-

... More
Supply and fixing in repairs following MCCB's including studs and lugs in existing LT panel fixing complete all as specified and directed.

-

-

-

... More
Mechanical seal set upper and lower

4

-

-

... More
50mm nominal bore

2

-

-

... More
Material and labour for cable joint kit of size 3.5 core 185 sqmm for heat shrinkable straight through joint complete all as specified and directed

2

-

-

... More
Supply and fixing in replacement of rubber packing suitable for flange 50mm dia complete all as specified and as directed

50

-

-

... More
CI suction plate as per existing at site

6

-

-

... More
S&F LED street light fittings 70 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaries with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories with existing high-mast/building/pole light fitting in and including reqd three core copper conductor complete taking out existing UNSV old one complete all as specified and as directed. Make : Havells-ENDURASUNDOWNSL70WLED765PASYBOTG/ Bajaj Cat No.ZELA P 72L WH PO TG SD J/ Eveready Cat No. LEDSL072I5H-PC or Equivalent make as listed in PS

25

-

-

... More
Taking down old UNSV any type changeover switch and S&F Off-load changeover switches 415V, 50 Hz 200 Amps 4 Pole on existing pole/wall complete all as specified. Make : Havells Cat No IHBFFE0200 or equivalent make as listed in PS.

2

-

-

... More
50mm nominal bore

2

-

-

... More
S&F in replacement of flexible suction hose pipe heavy duty ISI marked of size 90 mm outer dia complete all as specified and directed

40

-

-

... More
50mm nominal bore

30

-

-

... More
Supply and laying LT UG XLPE cable insulated armoured heavy duty electric, power cable with aluminium conductor, 1100 volts grade laid in trenches, fixed to poles etc including taking down old unsv cable of the following size:-

-

-

-

... More
O ring set as per existing at site

5

-

-

... More
Gun Metal suction ring of existing at site

16

-

-

... More
3.5 Core 185 Sqmm

150

-

-

... More
75 mm bore

2

-

-

... More
Returning filling in using excavated soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick all as specified and as directed.

116.5

-

-

... More
Material and labour 50 Sqmm PVC insulated copper conductor, single core cable including lugs in surface/wall/floor as required area complete all as specified and directed

70

-

-

... More
Impeller nut as per existing at site

5

-

-

... More
80mm nominal bore

2

-

-

... More
MCCB 250 Amps 25 KA, 4 Pole

5

-

-

... More
110 mm bore

2

-

-

... More
S&F in repair dosing system FRP solution preparation cum settling tank capacity 100 ltrs fitted with lid, port hole, inlet/outlet/ drain connection, sludge deposition facility, level gauge, speed reducing motor and SS-304 agitator (FRP coated for extra protection) complete all as directed.

2

-

-

... More
MCCB 200 Amps 36 KA, 4 Pole

4

-

-

... More
S&F LED street light fittings 120 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaries with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories with existing high-mast/building/pole light fitting in and including reqd three core copper conductor complete taking out existing UNSV old one complete all as specified and as directed. Make: Havells-ENDURASUNDOWNSL120 WLED765PASYBOTG / Bajaj Cat No.ZELA P 144L WH PO TG SD/ Eveready Cat No. LEDSL120I5-04 or Equivalent make as listed in PS

18

-

-

... More
Pressure ring of suitable size for the compressor existing at site

4

-

-

... More
Material and labour 70 Sqmm PVC insulated copper conductor, single core cable including lugs in surface/wall/floor as required area complete all as specified and directed

60

-

-

... More
Earthing complete with galvanised steel earth plate electrode 600x600x6mm buried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts, check nuts and washers of galvanised iron and 32x6mm GI strip protected by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1 , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kgs /Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I complete including taking down the old unsv earthing from site all as specified and directed .

11

-

-

... More
(i) Capacitor Duty Contactor 1 KVAR - 2 Nos (ii) Capacitor Duty Contactor 3 KVAR - 2 Nos (iii) Capacitor Duty Contactor 4 KVAR - 1 No (iv) Capacitor Duty Contactor 5 KVAR - 1 No (v) Capacitor Duty Contactor 6 KVAR - 2 Nos (vi) Capacitor Duty Contactor 10 KVAR - 1 No (vii) Capacitor Duty Contactor 16 KVAR - 1 No (viii) Capacitor Duty Contactor 20 KVAR - 1 No (ix) Capacitor Duty Contactor 25 KVAR - 1 No (x) Capacitor 01 KVAR having tolerance 0% - 10% with discharge device resistor, confirmed to IS 13340 - 2 Nos (xi) Capacitor 3 KVAR having tolerance 0% - 10% with discharge device resistor, confirmed to IS 13340 - 2 Nos (xii) Capacitor 4 KVAR having tolerance 0% - 10% with discharge device resistor, confirmed to IS 13340 - 1 No (xiii) Capacitor 5 KVAR having tolerance 0% - 10% with discharge device resistor, confirmed to IS 13340 - 01 No (xiv)) Capacitor 6 KVAR having tolerance 0% - 10% with discharge device resistor,. confirmed to IS 13340 - 2 Nos (xv) Capacitor 10 KVAR having tolerance 0% - 10% with discharge device resistor,. confirmed to IS 13340 - 01 No (xvi) Capacitor 16 KVAR having tolerance 0% - 10% with discharge device resistor,. confirmed to IS 13340 - 01 No (xvii) Capacitor 20 KVAR having tolerance 0% - 10% with discharge device resistor,. confirmed to IS 13340 - 01 No (xviii) Capacitor 25 KVAR having tolerance 0% - 10% with discharge device resistor, confirmed to IS 13340 - 01 No

-

-

-

... More
75mm outer dia

200

-

-

... More
Material and labour for painting on steel and iron surfaces of size upto 150 mm dia with one coat of synthetic enamel paint as per existing colour scheme or pattern or as per standard after preparation of old painted surface of any description over 10cm in width or girth complete all as specified and directed.

500

-

-

... More
Boring holes under road pavement by boki/ manually in any type of soil upto 150 mm bore complete all as specified and directed.

60

-

-

... More
S&F LED Flood Light fittings 120 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaries with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories with existing high-mast/building/pole light fitting in and including reqd three core copper conductor complete taking out existing UNSV old one complete all as specified and as directed. Make : Bajaj-BJFL 120W LED/ Crompton Cat No.CFS-504-120-57-60D-SL-GL-NSG/ Eveready Cat No. LEDFL120I5-04L or Equivalent make as listed in PS.

30

-

-

... More
MCCB 320 Amps 36 KA, 4 Pole

2

-

-

... More
3.5 Core 25 Sqmm

200

-

-

... More
Supply, installation and testing flanged ends strainer/dirt box of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclined/ vertical position, including taking out unsv strainer/dirt box complete all as directed at site. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.

-

-

-

... More
Material and labour for quartz silica sand of 32 -64 grade media size.

1

-

-

... More
1.5 Sqmm

150

-

-

... More
3.5/ 4 core 25 Sqmm to 3.5 core 50 Sqmm

150

-

-

... More
Supply and laying 3 layer (Polypropylene random copolymer) concealed pipes PP-R pipes PN 10/SDR 11) stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fitting in trenches/wall/ceiling or laying in floors complete of following sizes including all fittings with and including taking down old unsv any size of pipe complete all as specified and as directed. Note:- Excavation & earth work shall be measured & paid separately under relevant items.

-

-

-

... More
Taking down old unserviceable any type of starter any size and supply and fixing new starter ML 1.5 FASD with ML relay range 13-21 Amps including stainless steel box copper lugs existing starter panel complete all as specified and directed

2

-

-

... More
100mm nominal bore

30

-

-

... More
Stamping of stator

4

-

-

... More
CI Lower Housing chamber of existing at site

4

-

-

... More
Supply and fixing in replacement of rubber packing suitable for flange 100mm dia complete all as specified and as directed

10

-

-

... More
Material and labour for quartz silica sand of 8 - 16 grade media size.

1

-

-

... More
Impeller key as per existing at site

7

-

-

... More
Insulation kit as per sample

5

-

-

... More
Material and labour for quartz silica sand of 16 - 32 grade media size.

1

-

-

... More
110mm outer dia

300

-

-

... More
Material and Labour for fabrication of base frame with MS Channel MC-25/50/75/100/125 for foundation of centrifugal pump set/steps/General Frame work at STP incl one coat of red oxide and two coats of black enamel paint and incl taking out of old base frame and grouting new one existing with all nuts and bolts complete all as specified and directed.

500

-

-

... More
Material and labour for cable joint kit of size 3.5 core 240 sqmm for heat shrinkable straight through joint complete all as specified and directed

2

-

-

... More
Material and labour for cable joint kit of size 3.5 core 95 sqmm for heat shrinkable straight through joint complete all as specified and directed

4

-

-

... More
Asbestos graphite packing (stuffing box) of suitable size for the compressor existing at site

2

-

-

... More
Asbestos graphite packing (casing cover) of suitable size for the compressor existing at site

2

-

-

... More
M&L for Periodical Cleaning dewatering and pumping out of existing accumulated Sewage/sludge and removing of settled down Sewage sludge cum mud/De-Silting etc of Sewage Well of size upto 8 mtr height x 6 mtr dia complete all as specified and as directed. Notes for srl item Nos 56 to 57:- The rate quoted shall include the aspects:- (i) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De-Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes . (ii) Tractor mounted storage tank of appropriate capacity not less than 1 KL with driver directly collected from the soak well and disposing the same to the location where approved by the Chennai Cantonment Board/PCB . (iii) Tractor/truck with driver for disposal of sewage sludge and POL required for the same (duly covered with necessary Tarpaulins ) and depositing the same to the location where approved by the Chennai Canttonment Board/PCB. (iv) Labour element and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/ staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same at the location where approved by the Chennai Cantonment Board/PCB (v) Appropriate qty of Phenyl required at site for Sterilization of sewage sludge being collected in the Sewage tank . (vi) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary Phawda, Steel Bucket, Manila rope etc required at site.

3

-

-

... More
Supply, fixing, jointing & testing butterfly valve (wafer type) of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.6, PD Short body, inserting new one complete all as specified and as directed at site

-

-

-

... More
Gun Metal Impeller of existing at site

12

-

-

... More
Supply and fixing of PPR gate valve (Brass inserted), ISI Marked of following size, complete all as specified and as directed

-

-

-

... More
Water seal of existing at site as per pump design

20

-

-

... More
Fine Sieved excavated dry soil obtained using excavated soil and laid to the required width of trench at bottom and top of cable as cushioning all as specified and as directed.

10

-

-

... More
S&F LED street light fittings 90 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaries with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories with existing high-mast/building/pole light fitting in and including reqd three core copper conductor complete taking out existing UNSV old one complete all as specified and as directed. Make : ENDURASUNDOWNSL90 Havells- WLED765PASYBOTG / Bajaj Cat No.ZELA P 108L WH PO TG SD/ Eveready Cat No. LEDSL090I5-PC or Equivalent make as listed in PS

29

-

-

... More
Material and Labour Burnt bricks sub class 'B' old size laid in trenches with equal to length of bricks across the cable for cable protection all as specified and as directed

7000

-

-

... More
100mm nominal bore

3

-

-

... More
Material and labour for cable joint kit of size 3.5 core 120 sqmm for heat shrinkable straight through joint complete all as specified and directed

6

-

-

... More
Supply and laying of GI tubes, 'light grade' galvanised, with all fittings of bore of tube 80 mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed

30

-

-

... More
Taking down old unsv APFC feeder pillar box outdoor and Supply install test and commission APFC panel made of 2 mm thick CRCA sheet steel enclosure cubical type powder coated with 3 phase and 4 wire copper Bus bars of rating 400 Amps heat shrinkable colour coding sleeves suitable for LT 415 volts 50 Hz consisting of the following including power and control wiring with copper cable complete all as specified and as directed. (a) 400 Amp capacity for three phase and neutral, copper bus bar duly insulated with colour coded heat shrinkable sleeves and mounted on suitable DMC/epoxy insulators. (b) A set of heavy duty, capacitor, type MPP, 440 Volts, box type, with output 100 KVAR capacity, capacitor bank in 12 steps of fwg KVAR configuration to accommodate all possible set ups. (c) MCB's TP, `C' series, 415 volts of required sizes with required numbers and suitable ratings as per the cap of capacitors. (d) Micro processor based control suitable for power factor correction with its unique features of suitable quadrant operation automatic C/K ratio selection. The APFC controller should ON/OFF the capacitor banks of 100 KVAR cap capacitor bank in 12 steps of fwg KVAR to accommodate all possible set ups with indication whether it is lagging or leading.

2

-

-

... More
Stainless Steel stud with nut of existing at site

75

-

-

... More
80mm nominal bore

2

-

-

... More
Labour only for attending and identifying electric supply complaints of day to day maintenance of existing LT Panels/ LT Cable including connecting electrical accessories/ spares of water supply Elect supply installations, electrical fitting with lights, short circuits in Pump house as per complaint register complete all as specified & directed. Note:- (i) The quoted rate shall deemed to be including the cost of labour involve above sch items. (ii) The complaints shall be attended and the defects shall be rectified by a team of experienced electrician as applicable assisted with adequate number of helpers as directed by Engineer-in-charge.

200

-

-

... More
Supply and lay in replacement of MS Pipes heavy grade (C) class with all fittings laid in floors/ trenches/ fixed to walls/ fixed on ceilings including connections to centrifugal pump sets for suction, pump to header and to connect in/out going water main CI/DI/GI/ PP-R pipes with necessary welding as required at site and removing old unsv pipe of following bore complete all as specified and as directed. Note:- Rate quoted shall deemed to be included for MS flanges and flange joints.

-

-

-

... More
Suction air filter of suitable size/type for the compressor existing at site

2

-

-

... More
Connection plate of existing at site

6

-

-

... More
Oil level glass of suitable size for the compressor existing at site

2

-

-

... More
M&L for preparing old painted asbestos cement building board panel surfaces of any description, over 10 cm in width or girth and applying one coat of cement base paint (as approved tint) complete all as specified and as directed

325

-

-

... More
Supply and laying of GI tubes, 'light grade' galvanised, with all fittings of bore of tube 100mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed

25

-

-

... More
Outer distance bush of suitable size for the compressor existing at site

1

-

-

... More
Labour for cutting, welding of CI /DI/GI/MS pipe in position for reducing to required length for insertion of new tees, branches, butterfly valve (wafer type) etc of upto 150 mm bore complete all as specified and directed.

5

-

-

... More
Material and labour for activated carbon filter media IV1000. Note for item no. 28 to 32:- the cost for removal the old material from site to the location complete all as specified and directed deemed to be included in item.

150

-

-

... More
Material and labour for cable joint kit of size 4 core 25 sqmm for heat shrinkable straight through joint complete all as specified and directed

6

-

-

... More
Labour for dismantling, disconnecting the Air Blower twin lobe positive displacement type of pressure upto 0.8Kgs/Cm2 and capacity upto 800 Cum/hr including disconnecting from channel frame and electrical panel for repair of gear box, refitting of gear box after oiling, greasing, alignment of pump set and re-fixing/ assembling testing to make it functional complete including cleaning of all dirt, dust replacing the air filter with similar type and make of new filter etc complete all as specified and directed including transportation to workshop for repair complete all as specified and as directed

4

-

-

... More
Supply only in replacement of following spare for non clogging sub Pump set of cap 3 HP to 20HP

-

-

-

... More
Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclined/vertical position, including taking out unsv water meter complete all as specified and directed at site. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.

-

-

-

... More
MCCB 250 Amps 36 KA, 4 Pole

2

-

-

... More
S&F in replacement of indicating lamps (R.Y.B) LED type all as per existing size and type complete all as specified and directed.

18

-

-

... More
Temperature sensor as per existing at site

6

-

-

... More
50mm nominal bore

2

-

-

... More
Supply only copper rewinding wire of existing gauge for non clogging pump sets/ centrifugal pump Sets/ Induction motors including taking down old unsv copper wire complete all as specified and directed

80

-

-

... More
Roller Bearing 3308

6

-

-

... More
Bearing tapper bush for roller bearing 22213 EK/C3 or of suitable size for the compressor existing at site

3

-

-

... More
100mm nominal bore

3

-

-

... More
32mm outer dia

150

-

-

... More
Moisture sensor as per existing at site

5

-

-

... More
M&L for Periodical Cleaning of sewage well, Oil & Grease chamber, bar screen chamber, Equalization tank, treated water tank of any size/capacity and removing of settled down Sewage sludge cum mud/De-Silting etc complete of capacity 200 and 250 KLD STP all as specified and as directed. Notes :- (a) Cleaning inner surface of tank complete by scraping with steel wire brush and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr all as directed. (b) Washing with clean water and bleaching powder complete tank internally and removal of left out sludge if any at site at a distance not exceeding 50mtr all as directed.

2

-

-

... More
Material and labour for cable joint kit of size 3.5 core 70 sqmm for heat shrinkable straight through joint complete all as specified and directed

6

-

-

... More
3.5 Core 120 Sqmm

120

-

-

... More
Supply and fixing direct on line starters in sheet steel enclosure type MN/ML (motor rating AC-3 duty, 415V, 50 Hz, 3 Phase up to 10 HP including taking down old unsv starter complete all as specified and as directed

2

-

-

... More
Supply and fixing man hole cover of UG/semi UG Sump tanks of any size made out of 3 mm thick MS sheet and angle iron of size 40x40x6 mm duly welded and having handle on top to open and close the cover welding two butt hinges including painting with two coats of synthetic enamelled paint over a coat of primer including taking out old unsv cover complete all as specified and directed.

130

-

-

... More
Supply and fixing in replacement of rubber packing suitable for flange 80mm dia complete all as specified and as directed

80

-

-

... More
80mm outer dia

3

-

-

... More
4 Core 25 Sqmm

200

-

-

... More
90mm outer dia

200

-

-

... More
Taking down old UNSV any type changeover switch and S&F Off-load changeover switches 415V, 50 Hz 100 Amps 4 Pole on existing pole/wall complete all as specified. Make : Havells cat No IHBFFE0100 or equivalent make as listed in PS.

2

-

-

... More
Testing of Sewage water as per relevant IS of STP, submission of detailed test report to the office of the Engineer-in-charge and testing in NABL approved laboratory as approved by GE details are as under :- (a) Carrying out minimum essential testing of sewage water as per relevant IS mandatory for chemical, odour, PH Value, TSS, BOD, COD total nitrogen, sulphate, oil and grease ammoniac Nitrogen (NH3-N) and Bacteriological total collifrom organisms and other characteristics as per relevant IS of sewage water. Note:- Rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample

16

-

-

... More
Supply installation, testing and commissioning of LED post top lantern 20W light fitting long life LED module complete accessories as recommended by manufacturer suitable for 220/240 volt AC supply with IP 65 protection including necessary connection and taking down old unsv any type of post top lantern etc all as specified and as directed. Make : Havells :RUBYPT25WLED830SSYMTOPC/ Bajaj Cat No.BGCTNP 20W LED WH/WW/ Eveready Cat No. LEDPOST025I5-03 or Equivalent make as listed in PS.

30

-

-

... More
80mm nominal bore

3

-

-

... More
Labour for opening the non clogging submersible/centrifugal pump set, repairing, rewinding and assembling the pump set including insulating material of capacity 3HP to 20 HP capacity complete all as specified and directed. Note:- Copper winding wire and other spare part required for repairing will be measured and paid under relevant item as supply only

15

-

-

... More
Supply and fixing in replacement of mild steel nuts, bolts & washers etc of any size complete all as specified and as directed

160

-

-

... More
80mm nominal bore

20

-

-

... More
Cable kit without float switch

2

-

-

... More
Supply and fixing in replacement Amp meter class 1 and including suitable CT coil in existing LT Panel board fitted complete as per existing model complete all as specified and as directed.

18

-

-

... More
MCCB 125 Amps 25 KA, 4 Pole

6

-

-

... More
MCCB 100 Amps 25 KA, 4 Pole

8

-

-

... More
Material and labour for cable joint kit of size 3.5 core 35 sqmm for heat shrinkable straight through joint complete all as specified and directed

6

-

-

... More
Remetaling of rotor & turning/grinding

5

-

-

... More
100mm outer dia

2

-

-

... More
MCCB 400 Amps 36 KA, 4 Pole

2

-

-

... More
(e) Thyristor switches shall be provided for connecting / disconnecting the capacitor banks to the bus bar (f) The APFC panel provided with two terminal and it is connected through GI strip 32x6mm size to separate earthing all as specified and directed. (g) Digital panel meter for current, voltage/frequency and power factor having programmable CT ratio and built in selector switch of size 96mmx96mm, accuracy class-I, auxiliary support of 230 volts AC with SP MCB protected shall be provided. (h) All control wires shall be not less than 2.5 Sqmm multistranded copper conductor FRLSH cable and properly bunched/ tied, ferruled for proper identification and crimpled with adequate size of lugs. The cubical will have a bottom support of channel of suitable size, duly coated with zinc metal coating. A detachable pre drilled gland plate of thickness 2mm thick, cold zinc metal coated shall be provided at the bottom for entry for armoured cable with adequate size of cable gland. Manufacturer name plate with feeder details and danger plate shall be provided at suitable visible place. (j) Auxiliary contactor with required quantity of `NO & NC'. (k) Auto/Manual switch - 01 No (l) MCB for line protection as per requirement and as approved. (m) Indicator lamp LED based with lamp holder as per requirement and as approved (n) Current transformer (CT) of ratio 200/5 A, measuring class accuracy 0.5 to 1.0 for capacitor panel. (o) Incoming MCCB capacity 250 Amps, 4 Pole , 415V, 50 Hz, 35 KA fixed/manual type - 01 No (p) Detuning reactor of suitable size shall be provided to maintain THD less than 7 %. The panel should be ISO 9001 certified & CPRI approved make only. Fwg steps are as under :-

-

-

-

... More
Material and labour for earthing complete with galvanised steel earth plate electrode 60x60cmx 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and as directed

5

-

-

... More
Material and labour for quartz silica sand of 4 - 8 grade media size.

1

-

-

... More
Oil seal of suitable size for the compressor existing at site

2

-

-

... More
Supply and installation, connecting, testing and commissioning in replacement of high pressure single head adjustable Dosing System Adjustable 10% to 100% through a simple adjustment knob with an accuracy of + 2%, Inj. pressure 10 kg/sqcm, power input 230V, 50Hz, Max output 27 ltr/hr with mandatory accessories like lead tubing, connecting ferrules, check valves etc. Accessories must include the following :- (i) Level switch for dry run cut off to avoid motor failure. (ii) Adaptor in stainless steel construction with FHP motor for solution making. (iii) FRP Dosing tank of net capacity 100 ltrs with removable lid, level indicator and chemically resistant to all generally used dosing chemicals. (iv) Suitable agitator single phase flange mounted motor with plastic shaft and impeller.

2

-

-

... More
Supply and fixing CI foot valve flanged ends, swing type operation with rubber sheet, as per IS:4038 including taking out unsv foot valve all as specified and directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.

-

-

-

... More
Air compressor shaft welding, turning, grinding required during overhauling of compressor

2

-

-

... More
3.5 Core 240 Sqmm

145

-

-

... More
90 mm bore

2

-

-

... More
4 Sqmm

200

-

-

... More
Material and labour for rendering 10mm thick with cement mortar 1:6 on fair faces of brick work / concrete surfaces, finished the surface even and fair complete all as specified and directed.

600

-

-

... More
50mm outer dia

150

-

-

... More
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, laying of cable etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.

202.5

-

-

... More
CI suction chamber perfectly suitable as per existing at site

6

-

-

... More
50mm nominal bore

3

-

-

... More
3.5 Core 50 Sqmm

300

-

-

... More
50 mm bore

3

-

-

... More
3.5 core 70 Sqmm to 240 Sqmm

150

-

-

... More
Taking out existing LT UG cable laid in trenches/fixed to poles etc and refixing/relaying the same after connected repair works cable of following sizes :- Note: Earth work excavation will be measured and paid separately under relevant items)

-

-

-

... More
Supply, fixing, jointing and testing of cast iron non return valve without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unsv NRV complete all as specified and as directed at site. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.

-

-

-

... More
Taking down old UNSV any type changeover switch and S&F Off-load changeover switches 415V, 50 Hz 320 Amps 4 Pole on existing pole/wall complete all as specified. Make : Havells Cat No IHBFFE0320 or equivalent make as listed in PS.

3

-

-

... More
Taking down / lowering the flood light assembly from high mast light pole by operating motor or by manually by operating handle system for repairing / replacing the unsv flood light assembly complete or partially as directed as per site requirement including greasing of gear wheels and steel rope for smooth up and down of light assembly and checking of electric connection to motor system / contacts all as directed.

3

-

-

... More
Supply and fixing in replacement following parts in the twin lobe positive displacement type and pressure rating upto 0.8Kgs/cm2 of existing make at site

-

-

-

... More
Material and labour 25 Sqmm PVC insulated copper conductor, single core cable including lugs in surface/wall/floor as required area complete all as specified and directed

55

-

-

... More
6 sqmm

150

-

-

... More
Taking down old unsv feeder pillar box outdoor and Supply, installation, testing and commissioning of LT Feeder pillar box suitable for 415V, 3 phase, 4 wire, 50 Hz AC supply, outdoor type factory made powder coated dust and vermin proof made out of 3.15 mm thick CRCA steel mounted on 50x50x6mm mild steel angle iron with water proof top canopy , ventilated side louvers, twin leaf doors at front and rear side with suitable locking arrangement, sheet steel enclosed bus bar chamber with door, cable entry detachable bottom plates erected on and including PCC 1:3:6 type C1 (using 20mm graded stone aggregate) pedestals, as complete with and including the following:- Incoming:- (a) MCCB 4 Pole, 400A Adjustable thermal and magnetic type breaking capacity 36 KA- 01 No Outgoing:- (a) MCCB 4 Pole, 200A Adjustable thermal and magnetic type breaking capacity 25 KA- 01 No (b) MCCB 4 Pole, 100A Adjustable thermal and magnetic type breaking capacity 25 KA- 02 Nos (c) MCCB 4 Pole, 63A Adjustable thermal and magnetic type breaking capacity 25 KA- 01 No (d) Analogue 24 Hr Timer switch, 63 Amps MCB TPN with 63 Amp 4 pole contactor -1 No. Bus bar:- 600 A TPN & E Copper bus bar suitable for 35KA for 1 sec Metering Unit: - (i) R Y B Indications (LED Type) - 1 set (ii) 0-500 A Ammeter digital type with inbuilt selector switch - 1 No (iii) 0-500V Voltmeter digital type with inbuilt selector switch - 1 No (iv) CT,s - 100/5A, CL-1,15 VA - 1 set Note :- Contractor shall be take approval of Accepting Officer for panel drawing before fabrication work.

2

-

-

... More
Supply and fixing in replacement Amp meter as per existing model up to 50 Amps.

5

-

-

... More
Jointing Kit of submersible cable

7

-

-

... More
Material and labour for fixing of water pressure gauge (0-5 Kg/cm square) 100mm dial size including boring, threading, welding in CI/DI/GI/MS of any sizes and connected with suitable size of U type MS/CP pipe with ON OFF cock all as specified and directed.

3

-

-

... More
MCCB 160 Amps 25 KA, 4 Pole

5

-

-

... More
Disconnecting electric connections from LT control panel and starter of Non clogging submersible /Centrifugal pump set of capacity 3 HP to 20 HP and removing the pipe line connections from discharge side and taking out sub pump set along with, column pipe from Sewage sump/Well/Tank etc with the help of chainpully including transportation to wksp for repair including replacement of rusted nuts bolts. rubber gasket complete all as specified and directed. NOTE:- 1. The quoted rates will include for the charges wherever hydra is required for pulling out the pumps out. 2. The contractor will give a guarantee for 6 months for the proper functioning of the pumps and its allied pipe connections/Electrical connections. 3. Burn out/Defective Non clogging pumps will be open at site for the defects and material required for replacement in writing to Engr-in-Charge.

15

-

-

... More
Material and labour for Brick work with sub class 'B' bricks straight or curved on plan exc.6M mean radius built in CM 1:4 as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing from site all as specified and as directed at site.

8

-

-

... More
25 mm bore

10

-

-

... More
3.5 Core 70 Sqmm

240

-

-

... More
Material and labour 16 Sqmm PVC insulated copper conductor, single core cable including lugs in surface/wall/floor as required area complete all as specified and directed

100

-

-

... More
Material and labour for cable joint kit of size 3.5 core 50 sqmm for heat shrinkable straight through joint complete all as specified and directed

7

-

-

... More
32 mm bore

5

-

-

... More
Removing the surplus excavated material/ soils from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point all as specified and as directed.

76

-

-

... More
Cable kit with float switch

2

-

-

... More
100mm nominal bore

3

-

-

... More
3.5 Core 35 Sqmm

200

-

-

... More
S&F in repair chlorine test kit instrument consists of coloured amples complete with all testing fitments and OT solution packed in rexene finish in wooden box complete all as directed.

2

-

-

... More
Taking down old unserviceable any type of starter any size and supply and fixing new starter ML 2 FASD with ML relay range 20 - 32 Amps including stainless steel box copper lugs existing starter panel complete all as specified and directed

2

-

-

... More
Preparation of old painted surface of electric poles mild steel tubular type 7.5 to 11Mtr long any type/ make/model including writing the MES No with white paint over black band of paint at a level of 1.2 m above ground level on each pole complete all as specified and directed.

79

-

-

... More
Supply and fixing water proof submersible cable 3 core copper conductor flat cable, PVC insulated 1100 volts grade, protected by means of metal clip along with the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable submersible cable complete all as specified and as directed at site of the following sizes:-

-

-

-

... More
Roller Bearing NU 305

6

-

-

... More
Supply & fixing in replacement of heat resistance, weather proof agro shed net for covering of tanks complete with fixing arrangement around the tank complete all as specified and directed.

900

-

-

... More
S&F in replacement of flexible suction hose pipe heavy duty ISI marked of size 65 mm outer dia complete all as specified and directed

40

-

-

... More
Supply and fixing in replacement Volt meter class 1 and including suitable CT coil in existing LT Panel board fitted complete as per existing model complete all as specified and as directed.

16

-

-

... More
Supply & pouring Compressor Oil (as recommended by OEM of eqpts) in air blower at STPs complete all as specified and directed

50

-

-

... More
Taking down old UNSV any type changeover switch and S&F Off-load changeover switches 415V, 50 Hz 63Amps 4 Pole on existing pole/wall complete all as specified. Make : Havells cat No IHBFFE0063 or equivalent make as listed in PS.

3

-

-

... More
SS rotor sleeve of existing at site

10

-

-

... More
3.5 Core 95 Sqmm

100

-

-

... More
100mm nominal bore

6

-

-

... More
Material and labour for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed at site.

7

-

-

... More
3.5 Core 150 Sqmm

150

-

-

... More
Roller bearing 3213A or existing at site

4

-

-

... More
Ball bearing 6306ZZ

10

-

-

... More
Supply and fixing single phase preventor, type VSP-II after taking down/out preventor as existing at site complete all as specified and as directed.

4

-

-

... More
Gear set of suitable size for the compressor existing at site

1

-

-

... More
2.5 Sqmm

150

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.