Indira Gandhi Centre For Atomic Research Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Indira Gandhi Centre For Atomic Research - IGCAR Tender

Works
Electrical and Electronics
Eprocure
Opening Date17 Jan 2024
Closing Date31 Jan 2024
Tender Amount₹ 29,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Maintenanace of LT 415 Volt Starter Control Panel as per the detailed specification. ( Refer Section V, Clause No.12 ).

40

-

-

... More
Maintenance of LT 415 Volt VTPN/TPN/SPN Power distribution board / TPN switches as per the detailed specification. ( Refer Section VI MNC, Clause No.17.3 ).

150

-

-

... More
Maintenance of Earth Pits including supply of Sodium Bentonite, and measurement of Earth Pit Resistance as per the specification. (Refer Sec VI (MNC), Clause No.2).

60

-

-

... More
Preventive and Breakdown maintenance of ECR/TAPE/CORD heaters upto 3kW for salt heating vessel and pipeline as per the detailed specification. ( Refer Section V, Clause No.13 ).

350

-

-

... More
Supply and Installation of Quartz insulated ceramic cord heaters for salt vessel heating as per the detailed specification. ( Refer Section V, Clause No.14 ).

-

-

-

... More
Cord Heater 220 volt, 200 Watts, 1 MTR Length nichrome

5

-

-

... More
Cord Heater 220 volt, 400 Watts, 2 MTR Length nichrome

5

-

-

... More
Cord Heater 220 volt, 600 Watts, 3 MTR Length nichrome

5

-

-

... More
Overhauling, Painting and test running of the following single/three phase motors as per the scope of work. (Refer Sec VI (MNC), Clause No.14.1).

-

-

-

... More
Above 0.5 HP and upto 2.0 HP Motor

40

-

-

... More
3.0 HP/5.0 HP Motor

60

-

-

... More
7.5 HP/10 HP Motor

40

-

-

... More
20.0 HP/25.0 HP Motor

10

-

-

... More
30.0 HP/35.0/40.0 HP Motor

5

-

-

... More
Supply, open installation testing and commissioning of the following sizes of VTPN DBs on MS frame work (MS frame will be measured separately) as per the scope of work. (Refer Sec VI, Clause No.15.1).

-

-

-

... More
DB VTPN 8 Way (8 Plus 24) IP 43 - IK 09 Cat No:507727 or equivalent with 1No 125A,4P MCB incomer and 8Nos 32A,3P MCB

1

-

-

... More
DB VTPN 4 Way (8 Plus 12) IP 43 - IK 09 Cat No:507725 or equivalent , with 1 No.125A FP MCB and 4Nos 63A 3P MCB.

1

-

-

... More
Supply, open installation testing and commissioning of the following DB with Double Door consisting of Phase, Neutral and Earth Bus and interconnecting wires. (MS item will be measured separately). (Refer Sec VI, Clause No.15.2).

-

-

-

... More
DB SPN 12 Way (12) WITH METAL DOOR IP 43 - IK 09cat No:507612 or equivalent

1

-

-

... More
DB TPN - ETPN 12 Way (8 Plus 36) DOOR, IP 43 - IK 09. WITH METAL DOOR cat No:507673 or equivalent

5

-

-

... More
Supply, open installation testing and commissioning of the following sizes of cable end termination box on MS frame work (MS frame will be measured separately) as per the scope of work. (Refer Sec VI, Clause No.15.1.15).

-

-

-

... More
Cable End Box for IP 43 all Flexy DB/VTPN MCB DB cat No:507936 or equivalent

2

-

-

... More
Cable End Box for IP 43 SPN 12 Way DB cat No:507915 suitable for SPN 12 Way DB cat No:507612

1

-

-

... More
Cable End Box for IP 43 TPN 12 Way DB cat No:507928 or equivalent suitable for TPN 12/16 Way DB cat No:507673/507674

5

-

-

... More
Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11).

-

-

-

... More
MS fabrication 1 coat primer & 2 coats synthetic enamel paint

200

-

-

... More
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).

-

-

-

... More
4 Core x 10 sq.mm

10

-

-

... More
3.5/4 C x 35 sq.mm

10

-

-

... More
3.5/4C x 50/70 sq.mm

10

-

-

... More
Supply Installation testing and commissioning of the following MCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).

-

-

-

... More
6-32 Amps SP MCB (Type-C)

50

-

-

... More
6-32 Amps TP MCB (TYPE-C)

20

-

-

... More
40-63Amps, FP MCB (TYPE-C)

20

-

-

... More
6-32 Amps DP MCB (TYPE-C)

20

-

-

... More
Supply, installation, testing and commissioning of the following SDFU with factory made enclosure with 3Nos Fuse links on MS frame work as per the scope of work. (MS item will be measured separately). (Refer Sec VI, Clause No.14).

-

-

-

... More
SDFU TPN 63A, DIN FUSES with 3Nos 63A HRC fuse links, Sheet steel enclosure FN Cat No:SK90484

2

-

-

... More
Supply and installation of the following sizes of copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8).

-

-

-

... More
8SWG copper wire

100

-

-

... More
Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18).

-

-

-

... More
Wiring with 1 run of 1.5 Sq.mm copper wire

200

-

-

... More
Wiring with 1 run of 2.5 Sq.mm copper wire

200

-

-

... More
Wiring with 1 run of 4.0 Sq.mm copper wire

200

-

-

... More
Wiring with 1 run of 6.0 Sq.mm copper wire

200

-

-

... More
Supply, Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade XLPE insulated, Stranded copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification. ( Refer Section V, Clause No.15 ).

-

-

-

... More
4C X 2.5 Sq.mm Copper Multistanded XLPE Armoured cable.

500

-

-

... More
4C X 4.0 Sq.mm Copper Multistanded XLPE Armoured cable.

500

-

-

... More
Supply, Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100V grade Multi core multi stranded annealed tinned copper conductor with PVC Type C insulation and overall Flame Retardant Low Smoke (FRLS) PVC ( ST-2 ) or equivalent outer sheathed Control Cable of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification. ( Refer Section V, Clause No.16 ).

-

-

-

... More
4C X 1.5 Sq.mm copper flexible cable

500

-

-

... More
3C X 1.5 Sq.mm copper flexible cable

500

-

-

... More
6C X 1.0 Sq.mm copper flexible cable

500

-

-

... More
Supply, Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 600V grade Multi Core multi stranded annealed tinned copper conductor with PVC Type C insulation , such cores laid-up with overall aluminium foil tape and ATC braid with minimum 80% coverage and overall FRLS PVC (ST-2) or equivalent outer sheathed Control Cable of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification. ( Refer Section V, Clause No.17 ).

-

-

-

... More
1 Pair 1.0 Sq.mm copper flexible signal cable.

500

-

-

... More
6 Pair 1.0 Sq.mm copper flexible signal cable.

500

-

-

... More
Supply, cleaning the floor, proper pasting and installation of following insulating mat as per specification. (Refer Sec VI, Clause No.25).

-

-

-

... More
2.0 mm thickness, Max useable voltage 3.3kV, AC Proof voltage 10kV for 3 minutes, AC dielectric strength 30kV RMS Insulating Mat confirming to IS:15652

10

-

-

... More
Supply, Installation, testing and commissioning of the following stepper motor as per specification. ( Refer Section V, Clause 18 ).

-

-

-

... More
86mm, 9 Nm, 6 Amps, Bipolar winding, lead wire type, 1.8° Stepper Motor

2

-

-

... More
86mm, 6.4 Nm, 4 Amps, Bipolar winding, lead wire type, 1.8° Stepper Motor

2

-

-

... More
86mm, 9 Nm, 4 Amps, Bipolar winding, lead wire type, 1.8° Stepper Motor

2

-

-

... More
86mm, 4 Nm, 6.4 Amps, Bipolar winding, Metric plug type, 1.8° Stepper Motor

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.