Indira Gandhi Centre For Atomic Research Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Indira Gandhi Centre For Atomic Research - IGCAR Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Apr 2024
Closing Date30 Apr 2024
Tender Amount₹ 34,26,000
Costs
EMD
₹ 68,520Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IGCAR_803561_1Bid Award Id
ViewTender No
IGCAR/ESG/ESD/T1640/2024Tender Authority
Indira Gandhi Centre For Atomic Research ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Exhaust Fans ( 18") above 200 watts and up to 400 Watts Capacity.
5
-
-
... More
Overhauling and servicing of ceiling /pedestal/wall mounting / Exhaust/Air circulator fans (single phase) as per the Scope of work. (Refer Sec VI (MNC), Clause No.14).
400
-
-
... More
Painting of ceiling /Wall mounting/Pedestal/Exhaust/Air circulator fans (Single phase) as per the scope of work. (Refer Sec VI (MNC), Clause No.3).
450
-
-
... More
Attending to break down calls for following types of Fan Motors as per the scope of work . (Refer Sec VI (MNC), Clause No.15).
-
-
-
... More
Attending to break down faults in various types of Ceiling/Exhaust/Pedestal/Wall mounting /Air circulator Fans as per the scope of work.
350
-
-
... More
Cleaning of Ceiling / Pedestal / Wall mounting/Air circulator Fans/ fitted at different levels in various labs/Buildings as per the scope of work. (Refer Sec VI (MNC), Clause No.14.2).
750
-
-
... More
Removal of ceiling/Wall mounting/Exhaust fans of following sizes in labs/building/high bay/toilet in IGCAR (Refer Sec VI (MNC), Clause No.19).
-
-
-
... More
Fans Up to 5 Mtrs height
50
-
-
... More
Fans Above 5 Mtrs height
5
-
-
... More
Installation, testing and commissioning of following sizes of ceiling Fans and safety Steel rope with 3 Core, 1.5 Sq.mm (14/0.3) flexible copper cable including earth connection, Supply and fixing of regulator is not included in the scope of this item.(Note: Ceiling fan will be issued free of cost by the department).( (Refer Sec VI, Clause No.17.1).
-
-
-
... More
1200mm Sweep AC Ceiling Fan
30
-
-
... More
1400mm Sweep AC ceiling fan
15
-
-
... More
Installation of Exhaust /Air circulating fans in the labs/buildings/high bay as per the scope of work. (Refer Sec VI (MNC), Clause No.6).
-
-
-
... More
Fans upto 5mtrs height
15
-
-
... More
Fans Above 5mtrs height
5
-
-
... More
Inspection and testing of various types of ceiling/Pedestal/Wall mounting/Air circulating fans/ motors upto 0.5HP at Central Stores / Labs/ General office areas as per the scope of work. (Refer Sec VI (MNC), Clause No.24).
25
-
-
... More
Rewinding of the following LT motors as per the scope of work (Refer Sec VI (MNC), Clause No.11.2).
-
-
-
... More
Fractional HP Motor upto 0.5HP
10
-
-
... More
above 0.5 HP and upto 2.0 HP Motor
10
-
-
... More
3.0 HP Motor
3
-
-
... More
5.0 HP Motor
10
-
-
... More
7.5 HP Motor
5
-
-
... More
10.0 HP Motor
5
-
-
... More
12.5 H.P. Motor
1
-
-
... More
15 H.P. Motor
7
-
-
... More
20.0 HP Motor
2
-
-
... More
25 HP Motor
1
-
-
... More
30.0 HP Motor
1
-
-
... More
40.0 HP Motor
1
-
-
... More
60.0 HP Motor
1
-
-
... More
Overhauling, Painting and test running of the following single/three phase motors as per the scope of work. (Refer Sec VI (MNC), Clause No.14.1).
-
-
-
... More
Fractional HP Motors upto 0.5 HP
10
-
-
... More
Above 0.5 HP and upto 2.0 HP Motor
20
-
-
... More
3.0 HP/5.0 HP Motor
20
-
-
... More
7.5 HP/10 HP Motor
25
-
-
... More
12.5 HP/15.0 HP Motor
20
-
-
... More
20.0 HP/25.0 HP Motor
15
-
-
... More
30.0 HP/35.0/40.0 HP Motor
10
-
-
... More
50.0/60.0 HP/75.0 HP Motor
3
-
-
... More
Attending to break down calls for following types of Motors as per the scope of work . (Refer Sec VI (MNC), Clause No.15).
-
-
-
... More
Single phase Motors up to 2 HP
50
-
-
... More
3 Phase Motors from 3 HP to 12.5 HP
50
-
-
... More
3 Phase Motors from 15 HP to 35 HP
50
-
-
... More
3 Phase Motors from 40 HP to 75 HP
10
-
-
... More
Inspection and testing of following Capacities of motor at central Stores / Labs / office areas as per the scope of work (Refer Sec VI (MNC), Clause No.24).
-
-
-
... More
For capacities above 0.5 HP & upto 12.5 HP
25
-
-
... More
For capacities above 12.5 HP & upto 35 HP
10
-
-
... More
For capacities above 35 HP & upto 100 HP
5
-
-
... More
Maintenance of Motor Control centres/Distribution Centres, LT panels/TPN switch Fuse Units (Refer Sec VI (MNC), Clause No.17.2).
-
-
-
... More
Combination Switch fuse Units from 16A to 400A /Motor starters
350
-
-
... More
Cubicle switch boards having number of vertical sections up to 3
20
-
-
... More
Cubicle switch boards having number of vertical sections more than 3
5
-
-
... More
Maintenance of Electrical Panel on EOT cranes/Feeder Pillar (Refer Sec VI (MNC), Clause No.17.2).
-
-
-
... More
Maintenance of EOT Crane Electrical Panel
5
-
-
... More
Removal of termination of armoured cables of following sizes from electrical equipment or reconnecting of removed termination (Refer Section V)
-
-
-
... More
Sizes upto 4C X 25 sq.mm
140
-
-
... More
Sizes above 4C X 25 sq.mm and upto 4C X 70 sq.mm
5
-
-
... More
Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)
-
-
-
... More
3/3.5/4core X Upto 25 sqmm
500
-
-
... More
3/3.5/4Core X above 25 & up to 120 sqmm
50
-
-
... More
Supply and installation of protective wire mesh to replace the existing mesh for the following size of Fans (Refer Sec VI (MNC), Clause No.16.2).
-
-
-
... More
400 mm dia pedestal fans
20
-
-
... More
Supply and replacement of blades for fans of following sizes as per the scope of work. (Refer Sec VI (MNC), Clause No.16.3).
-
-
-
... More
12" blade for Exhaust fans
10
-
-
... More
15" Blade for Exhaust Fan
3
-
-
... More
16" Blade for pedastal fan
10
-
-
... More
Supply and installation of Electronic Regulator 400 Watt 1 module for ceiling fans as per scope of work. (Refer Sec VI (MNC), Clause No.16).
10
-
-
... More
Supply and installation of Electronic Regulator 450 Watt 2 module for ceiling fans as per scope of work. (Refer Sec VI (MNC), Clause No.16.1).
10
-
-
... More
Supply, Installation, testing and commissioning of following sizes of ceiling Fans and safety steel rope with 3 Core, 1.5 Sq.mm (14/0.3) flexible copper cable including earth connection. Supply and fixing of regulator is not included in the scope of this item. (Refer Sec VI, Clause No.17.1 ).
-
-
-
... More
1200mm Sweep AC ceiling fan
15
-
-
... More
1400mm Sweep AC Ceiling Fan
15
-
-
... More
Supply, testing and commissioning of following sizes of Pedestal fan and as per the detailed specification. . (Refer Sec VI, Clause No.17.3).
-
-
-
... More
400mm MAXX AIR Pedestal Fan or equivalent
25
-
-
... More
Supply, installation, testing and commissioning of following sizes of Wall Mounting Fans as per the detailed specification.. (Refer Sec VI, Clause No.17.4).
-
-
-
... More
450 mm Dia Industrial wall Mounting fan
10
-
-
... More
600mm dia Industrial wall mounting fan
2
-
-
... More
Supply, installation, testing and commissioning of following sizes of Wall Mounting Exhaust Fans including supply of Aluminium grill bracket with Stainless Steel Bolts for mounting of Exhaust Fan & Aluminium grill bracket and 3 Core, 1.5 Sq.mm (14/0.3) PVC insulated & FRLS sheathed copper flexible cable of required length as per the detailed specification. (Refer Sec VI, Clause No.17.2).
-
-
-
... More
300 mm Dia Turbo Heavy Duty Exhaust Fan
35
-
-
... More
380 mm Dia Turbo Heavy Duty Exhaust Fan
15
-
-
... More
450 mm Dia Turbo Heavy Duty Exhaust Fan
5
-
-
... More
230 mm dia Medium duty , Double ball bearing exhaust fan
3
-
-
... More
Collecting of scrap items and shifting more than 1 km and up to a distance of 5 kms. Measurement will be done on volume basis (Refer Sec VI (MNC), Clause No.28).
20
-
-
... More
Supply and replacement of following Motor Bearings during overhauling (Refer Sec VI (MNC), Clause No.14).
-
-
-
... More
Bearing Model No:6201 2Z C3 or equivalent
50
-
-
... More
Bearing Model No:6202 2Z C3 or equivalent
50
-
-
... More
Bearing Model No:6305 2Z C3 or equivalent
5
-
-
... More
Bearing Model No:6306 2Z C3 or equivalent
5
-
-
... More
Bearing Model No:6308 2Z C3 or equivalent
10
-
-
... More
Bearing Model No:6309 2Z C3 or equivalent
5
-
-
... More
Supply and Installation of following Wiring Accessories as per the detailed specification (Refer Sec VI (MNC), Clause No.5).
-
-
-
... More
1 No 10A Switch on modular plate and termination of wires to the switches
10
-
-
... More
1 No16A Switch on modular plate and termination of wires to the switches
10
-
-
... More
Supply and installation of following capacitor as per specification (Refer Section V)
-
-
-
... More
2.5 microfaradcapacitor with metalic casing
50
-
-
... More
4 microfaradcapacitor with metalic casing
25
-
-
... More
Supply and installation of Following Sizes of PVC insulated, PVC round sheathed Multi core Flexible copper conductor cables to extend power from street light pole bottom JB to light fitting as per detailed specification.(Refer Sec VI, Clause No.12.5). Spacer and clamping is not required
-
-
-
... More
1100V PVC insulated, PVC round sheathed Flexible Copper Conductor cable of size 3 Core x 1.5 Sq.mm
200
-
-
... More
1100V PVC insulated, PVC round sheathed Flexible Copper Conductor cable of size 3 Core x 2.5 Sq.mm
200
-
-
... More
Supply and replacement of the following contactors and accessories (Refer Sec VI (MNC), Clause No. 4) .
-
-
-
... More
Power Contactors, AC3 Rating MNX 3Pole 18A
5
-
-
... More
Power Contactors, AC3 Rating MNX 3Pole 32A
10
-
-
... More
Power Contactors, AC3 Rating MNX 3Pole 40A
15
-
-
... More
Bimetal over load relay (6-10)A or (9-15)A for direct mounting on MNX type contactor
8
-
-
... More
Bimetal over load relay (20-33)A for direct mounting on MNX type contactor
5
-
-
... More
Add on Block MNX-A1(2NO,2NC)
10
-
-
... More
Add on Block MNX-A1(1NO,1NC)
10
-
-
... More
Electronic Timers (T ype ST 100)
5
-
-
... More
MN 16 DOL Starter in Sheet-Steel Enclosure Type MN (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) on MS Frame. Note: MS Item will be measured separately.
10
-
-
... More
MN 16F Fully Automatic Star Delta Starter in Sheet-Steel Enclosure T ype MN / ML (Motor Rating AC-3 Duty, 415V , 50Hz, 3-Ph)on MS Frame. Note: MS Item will be measured separately.
5
-
-
... More
HF 20 A (Cylindrical Type HRC Fuse)
120
-
-
... More
HF 25A (Cylindrical Type HRC Fuse)
120
-
-
... More
HF 32 A (Cylindrical Type HRC Fuse)
180
-
-
... More
HF 40 A (Cylindrical Type HRC Fuse)
60
-
-
... More
HF 50 A (Cylindrical Type HRC Fuse)
60
-
-
... More
HF 63 A (Cylindrical Type HRC Fuse)
180
-
-
... More
HQ 20 A (Bolted Type HRC Fuse)
60
-
-
... More
HQ 25 A (Bolted Type HRC Fuse)
60
-
-
... More
HQ 32 A (Bolted Type HRC Fuse)
60
-
-
... More
HQ 63 A (Bolted Type HRC Fuse)
60
-
-
... More
HN 63 A (DIN Type HRC Fuse)
30
-
-
... More
HN 125 A (DIN Type HRC Fuse)
30
-
-
... More
HN 250 A (DIN Type HRC Fuse)
30
-
-
... More
HN 400 A (DIN Type HRC Fuse)
30
-
-
... More
End Termination of the following size Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).
-
-
-
... More
4C x 10 Sq.mm or 16Sq.mm including cable gland earthing
80
-
-
... More
Grass and tree branch removal in solar cooking site including disposal within a distance of 1 kM. Note: 1Number means the approximate area of the solar cooking site to be cleaned is 625 Sq.mtrs. (Refer Sec VI (MNC) Clause No. 7 )
4
-
-
... More
Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of end termination GI spacer, clamps etc as per the detailed specification. (Refer Sec VI, Clause No.5)
-
-
-
... More
3/3.5/4 Core upto 25 Sqmm
500
-
-
... More
Temporary laying of LT cables of following sizes in open air / in Built in trench. (Refer Sec VI (MNC), Clause No.30).
-
-
-
... More
Sizes up to 3.5C X 70 Sq.mm Aluminium conductor (Refer Sec VI (MNC), Clause No.30).
200
-
-
... More
Supply and open Installation of following Sizes of Hot dip galvanised MS boxes as per the detailed specification. (Refer Sec VI, Clause No.15.10).
-
-
-
... More
150(W)X150(H)X80(D)mm, 1.6mm thick sheet Hot dip galvanised MS box
10
-
-
... More
Cutting of scrap cables and shifting within a distance of 5 kms as per the scope of work. (Refer Sec V)
1000
-
-
Evaluation Notes How It Works ?