Indira Gandhi Centre For Atomic Research Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Indira Gandhi Centre For Atomic Research - IGCAR Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Jul 2024
Closing Date29 Jul 2024
Tender Amount₹ 82,30,000
Costs
EMD
₹ 1,64,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IGCAR_814572_1Bid Award Id
ViewTender No
IGCAR/ESG/ESD/T1666/2024Tender Authority
Indira Gandhi Centre For Atomic Research ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
415V Class - IV AHU Panel as per dwg no.IGC/T-1666/03
1
-
-
Supply fixing testing and commissioning of the following RCBOs on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).
-
-
-
RCBO FP 63A sensitivity 30mA 4Module
18
-
-
RCBO FP 40A sensitivity 30mA 4Module
6
-
-
Supply, transportation, installation, testing and Commissioning of the following types of Suspended luminaires. (Refer Sec VI, Clause No.16.1). - Catalogue No : Cane G6 EX LINEAR PENDENTS 40W 5700K CCT NON DIM WHITE (PC) DOWNLIGHT DISTRIBUTION 4 FEET CUSTOMISED SUSPENSION MOUNTING CLAMPS SUITABLE FOR 20MM THREADED ROD-PRIME - LPC0104057NDWEP0DL4C01 with downrod replacement fixing accessories or Equivalent and Lamp Type LED
90
-
-
Supply, transportation, installation, testing and Commissioning of the following type of Surface mounted luminaires. (Refer Sec VI, Clause No.16.1). - Catalogue No : WAND K 30W 5700K code SLWKY03057NDWEP04C22 -SURFACE LIGHTS NONDIM WITH CUSTOMIZED CLAMP OF 30 DEG. TILT WHITE (PC) 4FEET- PRIME or equivalent and Lamp Type LED
25
-
-
Supply, transportation, installation, testing and Commissioning of the following type of Surface mounted luminaires. (Refer Sec VI, Clause No.16.1). - Catalogue No : WAND K 9W 5700K 2Feet Batten or equivalent and Lamp Type LED
10
-
-
Supply, transportation, installation, testing and Commissioning of the following type of Surface mounted luminaires. (Refer Sec VI, Clause No.16.1). - Catalogue No :ILDSM01857NDGYP
Disc Min LOWBAY 18W 5700K CCT NON DIM GREY (PC) PRIMEor Equivalent and Lamp Type LED
7
-
-
Supply and external installation of following sizes of Heavy Duty, Hot Dip Galvanised MS ERW Conduits for Electrical & Communication System with all the required accessories like round JBs, Solid Long Bends, Check Nuts, Nipples, Couplings, Reducers, Copper Clips, Copper Conductor, GI Wire etc. as per the detailed specification. .(Refer Sec VI, Clause No.27).
-
-
-
25mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes.
100
-
-
32mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes.
100
-
-
Supply and external installation of following sizes of Heavy Duty, Hot Dip Galvanised MS ERW Conduits for Electrical & Communication System with all the required accessories like round JBs, Solid Long Bends, Check Nuts, Nipples, Couplings, Reducers, Copper Clips, Copper Conductor, GI Wire etc. as per the detailed specification. .(Refer Sec VI, Clause No.27).
-
-
-
3/3.5/4 Core Above 25 & Upto 120 Sqmm
100
-
-
3/3.5/4 Core Above 120 & Upto 240 Sqmm
100
-
-
3/3.5/4 Core Above 240 & Upto 400 Sqmm
100
-
-
Retrieval of the already laid one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes laid direct in ground including removal of end termination, excavation of trenches, retrieving of bricks, back filling and Relaying the same cable direct in ground by using retrieved bricks including transportation of cables, excavation and backfilling of soil, supply of sand & shortage bricks etc as per the detailed specification.
-
-
-
3/3.5/4 Core Above 240sqmm & upto 400 sqmm
50
-
-
Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)
-
-
-
3/3.5/4core X Upto 25 sqmm
200
-
-
3/3.5/4Core X above 25 & up to 120 sqmm
100
-
-
3/3.5/4Core X above 120 & up to 240 sqmm
100
-
-
3/3.5/4Core X above 240 & up to 400 sqmm
200
-
-
Supply, installation, testing and commissioning of the following Raychem make Heat Shrinkable Cable Straight Through Jointing Kits (Crimping type) for 3.5 Core Aluminium Conductor, 1.1 kV (E), PVC/XLPE insulated cables of following sizes as specified. Excavation will be measured separately (Refer Sec VI, Clause No.10.6).
-
-
-
Straight Through Joint (Crimping type) for 3.5 Core 120- 185 Sq. mm
2
-
-
Straight Through Joint (Crimping type) for 3.5 Core, 70-95 Sq. mm
2
-
-
Straight Through Joint (Crimping type) for 3.5 Core x 400 Sq. mm
2
-
-
End Termination of the following size Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).
-
-
-
4C x 10 Sq.mm including cable gland earthing
20
-
-
4C x 16 Sq.mm including cable gland earthing
20
-
-
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).
-
-
-
4 Core X 16 Sqmm
8
-
-
3.5/4 C x 35 sq.mm
40
-
-
3.5/4C x 50/70 sq.mm
4
-
-
3.5 x 185 sq.mm
6
-
-
3.5 x 400 sq.mm
6
-
-
Supply, fabrication and installation of the following size of Hot dip Galvanised GI Flats in Built in trenches on walls, poles, RCC Concrete and through embedded pipes as per the detailed specification. No cutting or drilling permitted after galvanisation. (Refer Sec VI, Clause No.12.9).
-
-
-
50 X 6 mm GI flat
100
-
-
25 X 6 mm GI flat
100
-
-
Supply and installation of the following sizes of copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8)
-
-
-
8SWG copper wire
150
-
-
Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11).
-
-
-
MS fabrication 1 coat primer & 2 coats synthetic enamel paint
900
-
-
GI: MS fabrication With hot dipped galvanising.
600
-
-
Removal of light fixtures (Refer Sec VI (MNC), Clause No.21 & Sec V part-A).
-
-
-
Removal of light fixtures in labs and low bay areas
150
-
-
Removal of old LT power distribution/Motor control centre panels consisting ACBs, SDFU's feeders, starter cubicles and its associated LT armoured cable from various buildings and safe transporting of the same panels up to 5 Kilometers as directed by EIC.
-
-
-
415V/1250A, PCC Panel (7 Vertical)-consists of ACBs -3 Nos and SDFUs for outgoing feeders -Ground floor Electrical room,IDEAS building
1
-
-
415V/200A, AHU Panel (3 Vertical)-consists of SDFUs-11 nos and STAR-DELTA Starters-3 nos (12.5 HP) ,Ground floor AHU room,IDEAS building
1
-
-
Collecting of scrap items and shifting more than 1 km and up to a distance of 5 kms. Measurement will be done on volume basis (Refer Sec VI (MNC), Clause No.28).
20
-
-
Supply and providing GI conduit downrod for installation of luminaries, fans etc as per the detailed specification.(Refer Sec VI, Clause No.16.5).
-
-
-
20mm dia GI conduit
150
-
-
Supply, cleaning the floor, proper pasting and installation of following insulating mat as per specification. (Refer Sec VI, Clause No.25).
-
-
-
2.0 mm thickness, Max useable voltage 3.3kV, AC Proof voltage 10kV for 3 minutes, AC dielectric strength 30kV RMS Insulating Mat confirming to IS:15652
20
-
-
Supply and Installation of laminated Hylam sheet of 3mm thickness over the boxes and as per the detailed specification.
5
-
-
Providing and fixing double Tubular scaffolding system using H-Frames / APS system or (cup lock type) on the exterior side upto seven storey height made with 40mm dia M.S. tube 1.5m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in-charge. The elevation area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding .
100
-
-
Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2
10
-
-
Maintenance of Earth Pits including supply of Sodium Bentonite, and measurement of Earth Pit Resistance as per the specification. (Refer Sec VI (MNC), Clause No.2).
6
-
-
Temporary installation of Power distribution panel as directed by Engineer-in-charge.(Refer Sec V Part A)
2
-
-
Supply and pasting of water proof stickers of 250 x 50 mm size with messages as directed by Engineer in charge as per the detailed specification. ( (Refer Sec V Part A )
10
-
-
Supply and Fixing of Powder coated MS Danger / Warning Boards of different Voltage levels as per the detailed specification. Make: Thadhani or equivalent. ( (Refer Sec V Part A ).
6
-
-
Removal of the following fuse DB's/SFU equipment already installed/embedded in wall, transporting the removed equipment to storage yard as directed by Engineer-in-charge. (Refer Sec V Part A).
-
-
-
63A/100A/125A, 500V, TP/TPN/SFU/ Combination SFU or 4/6/8/12 Way SPN fuse DB or 4/8 WAY TPN fuse DBs
20
-
-
Supply, open installation of the Double Door for existing DB- TPN - ETPN 12 Way (8 Plus 36) DOOR, IP 43 - IK 09. ( SIZE-600 mm * 450 mm) as directed by Engineer-in-charge.
1
-
-
Supply, installation, testing and commissioning of the following SDFU with factory made enclosure with 3Nos Fuse links on MS frame work as per the scope of work. (MS item will be measured separately). (Refer Sec VI, Clause No.14).
-
-
-
SDFU TPN 63A, DIN FUSES with 3Nos 63A HRC fuse links, Sheet steel enclosure FN Cat No:SK90484
17
-
-
Supply and Installation of following sizes of Surface Mounting Plastic Boxes as per the detailed specification. (Refer Sec VI, Clause No.15.6).
-
-
-
Surface Mounting Plastic Boxes 6 Module
6
-
-
Supply and Installation of 16A modular switch, 6/16 Amps combined shuttered type Socket and 10A modular switch & 3 pin, 6A shuttered type Socket, 6Modular Plate as directed by Engineer-in-charge.
6
-
-
Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29)
-
-
-
25 X 12 mm size of PVC Mini trunking
100
-
-
Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18)
-
-
-
Wiring with 1 Run of 1.5 Sq.mm Copper wire
200
-
-
Wiring with 1 Run of 2.5 Sq.mm Copper wire
200
-
-
Supply, transportation, installation, Configuration, testing and commissioning of the following Sensors as directed by the Engineer-in-Charge. (Refer Sec VI, Clause No.16 ).
-
-
-
Surface/Recess mountable type Occupancy & day light PIR SWITCH CORRIDOR sensor suitable for lighting load coverage 2mtr wide and 12mtr length on both sides. This scope also includes suply of 1 No. remote along with charger to operate the sensors(Refer Sec VI, Clause No.16.3). Make : Legrand, Model No. 488 17
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements