Indira Gandhi Centre For Atomic Research Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Indira Gandhi Centre For Atomic Research - IGCAR Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Jul 2024
Closing Date15 Jul 2024
Tender Amount₹ 46,10,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
4C x 2.5 Sq.mm including cable gland earthing

92

-

-

... More
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).

-

-

-

... More
4 Core X 16 Sqmm

6

-

-

... More
Supply, open installation testing and commissioning of the following DB with Double Door consisting of Phase, Neutral and Earth Bus and interconnecting wires. (MS item will be measured separately). (Refer Sec VI, Clause No.15.2).

-

-

-

... More
SPN, 16 Way Distribution Board with all accessories, cat No:507613

6

-

-

... More
16 WAY Cat No:DBTPI016DD (Vertical) or equivalent make TPN TIER Per Phase Isolation (PPI) DB

1

-

-

... More
Supply Installation testing and commissioning of the following MCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).

-

-

-

... More
6 - 32 Amps DP MCB (TYPE-C)

76

-

-

... More
Supply fixing testing and commissioning of the following RCCBs on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).

-

-

-

... More
RCCB DP 40A 30mA, TYPE AC

9

-

-

... More
Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11).

-

-

-

... More
MS fabrication 1 coat primer & 2 coats synthetic enamel paint

570

-

-

... More
Plain Cement Concrete.(Refer Sec VI, Clause No.26)

-

-

-

... More
1:2:4 Plain Cement Concrete

1

-

-

... More
Supply and installation of the 150x50x2 mm GI perforated Cable tray on MS supprt as directed by engineer incharge (Refer technical specification Section V)

215

-

-

... More
Supply, Installation, testing and Commissioning of Flameproof / Weatherproof Well Glass LED Light Fitting suitable for Zone1 & 2, Gas Group : IIA/IIB, IP-66, T6, with 50W LED, Supply Voltage: 230V AC , Glass: Toughened Clear Glass, Hardware: SS304, Cable Entries: 2 x 0.75ET. Incluning Double Compression brass Cable Glands & Blanking Plugs, Finish : Epoxy Powder Coated Light Grey. (Refer section V)

20

-

-

... More
Supply, Installation, testing and Commissioning of Flameproof / Weatherproof , Tube Light Fitting suitable for Zone1&2, IIA/IIB, IP-65, T6 with 2 x 18W T8 Philips (one end power supply connection) LED Tubes, Material: AL Alloy (LM6), Hardware: SS304, 230VAC, Cable entries: 2 x 0.75ET, Epoxy Powder Coated Finish. including Double Compression brass Cable glands & Blanking plugs. (Refer section V)

30

-

-

... More
Supply, Installation, testing and Commissioning of Flameproof Cum Weatherproof , 16A, DP, ON/OFF Rotary Switch suitable for Zone1 & 2, IIA/IIB & IIC, IP-66, T6, Cast AL Alloy (LM6), 230VAC 50Hz, SS304 Hardware, 2Nos x 0.75ET Cable Entry , Finish : Epoxy Powder Coated. (Refer section V)

13

-

-

... More
Supply, Installation, testing and Commissioning of Flameproof Cum Weatherproof- (2Nos. Plug & 2 Nos. Socket with One Box ) 16A, 1Ph, 230VAC, 50Hz, (2P+E) 3PIN, Plug & Socket suitable for Zone1 & 2, IIA/IIB, IP65, T6 Material: Die Cast AL (LM6), Hardware: SS304, Cable entries: 2 x M20 or 0.75ET, Finish: Epoxy Polyester Powder Coated Shade. Including Double Compression brass Cable glands & Blanking plugs. (Refer section V)

22

-

-

... More
Supply, Installation, testing and Commissioning of Flame proof Exhaust fan suitable for Zone1 & 2, IIA/IIB, IP-66, T6, Size : 12Inch Material : Cast Iron , 230VAC 50Hz, RPM : 1400, Hardware MS Gink Plated, 2Nos x 0.75 ET Or M20 Cable Entry, FINISH: Ligh Grey Epoxy Shade. including Double Compression brass Cable Glands & Blanking plugsPlugs. (Refer section V)

13

-

-

... More
Supply, Installation, testing and Commissioning of Flameproof Brass Double Compression Cable Gland Size : 0.75ET (Refer section V)

20

-

-

... More
Supply, Installation, Testing and Commissioning of ELCB extension box with 10 m 2.5 sqmm copper cable, 3 nos. 6A switch, 1 no 16 A switch, 3 no 6 A socket, 1 no 6/16 A socket, 1 no. indication lamp, 1 no. 25 A 30 mA RCCB and 1 No. 16 A MCB wall as per per the detailed specification and drawing. (Refer section V)

50

-

-

... More
Supply, installation, testing & commissioning of 4ft 1800 lumens LED T8 lamps with poly corbonate body & one end connection (Cat No. 18W865 T8 MASTER LED tube 1200mm of Philips or equivalent) as per the technical specification (Refer Section V)

500

-

-

... More
Supply, installation/ replacement , testing & commissioning of 150 W, 240 V high bay lamps with PIR based occupancy sensor (Cat No. BY615P LED150S 5700 NB PSU GR L1 of Philips or equivalent) as per the technical specification (Refer Section V)

124

-

-

... More
Supply, installation, testing & commissioning of PIR based Occupancy sensors with (Cat No. CSS54E WE of Schneider or equivalent) as per the technical specification (Refer Section V)

24

-

-

... More
Supply, installation, testing & commissioning of contactor (Cat No. CS94020BOOO of MX 0 22E 4P CONTROL CONTR 240VAC or equivalent) as per the technical specification (Refer Section V)

24

-

-

... More
Supply, installation, testing & commissioning of Flush head Push button with indicator (Cat No. EG03FDLW240A of L&T GENXT ILLBLK FLH H.WHT, 240VAC or equivalent) as per the technical specification (Refer Section V)

24

-

-

... More
Supply, installation in existing DB, testing and commissioning of 2A, DP, C-curve MCB as per the specification (Refer section V)

120

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.