Indira Gandhi Centre For Atomic Research Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Indira Gandhi Centre For Atomic Research - IGCAR Tender

Works
Electrical and Electronics
Eprocure
Opening Date7 May 2024
Closing Date3 Jun 2024
Tender Amount₹ 40,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2 to 63 Amps, 415 Volts, HRC Fuse link. (Fuses in one cubicle will be considered as 1 set)

75

-

-

... More
Replacement of components in streetlight sensor circuit as per the detailed specification. (Refer Sec VI (MNC), Clause No.12).

5

-

-

... More
Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11).

-

-

-

... More
MS fabrication 1 coat primer & 2 coats synthetic enamel paint.

100

-

-

... More
Replacement of following components in poles upto 11mtr or at high mast including removal of existing components

-

-

-

... More
Replacement of damaged street light JB with new one issued free of cost by the dept. Removed items to be returned to dept stores (Refer Sec VI (MNC), Clause No. 4)

30

-

-

... More
Maintenance of storage Batteries of different capacities used for solar/emergency street light including cleaning, toping up of electrolyte , cleaning of solar panel excluding supply of distilled water. (Refer Sec VI (MNC), Clause No.8).

108

-

-

... More
Major maintenance of storage Batteries of different capacities used for solar/emergency street light including removal, transportation to CSS, cleaning, toping up of electrolyte, boost charging, testing, transporting back to the original location, normalising the connection, cleaning of solar panel, functional checking etc excluding supply of distilled water. Transport vehicle will be provided by dept free of cost depending on availability. (Refer Sec VI (MNC), Clause No.8).

15

-

-

... More
Replacement of light fixtures (Refer Sec VI (MNC), Clause No.21).

-

-

-

... More
Replacement of street Light fixtures for poles upto 11mtr or at high mast including removal of existing components

250

-

-

... More
Supply, Installation, Testing and Commissioning of following Flood light luminaries on RCC/Metalic poles of height from 7 M to 12 M as per per the detailed specification. (Refer Sec VI, Clause No.16.1). - Catalogue No : CFS-506-250-57-60D-SL-GL-NSG and Lamp Type LED

30

-

-

... More
Supply Installation testing and commissioning of the following MCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).

-

-

-

... More
6-32 Amps SP MCB (Type-C)

50

-

-

... More
Inspection and testing of following lighting fixtures and accessories/Switch box, at Central Stores as per the scope of work. (Refer Sec VI (MNC), Clause No.24).

-

-

-

... More
Lamps up to 1000 W (CFL/Fluorescent/LED/SV/MH/induction/BC lamps) and Ballast ranging from 9 to 400 W and LED Driver

200

-

-

... More
Lighting fixtures

200

-

-

... More
Installation of light fixtures (Refer Sec VI (MNC), Clause No.21).

-

-

-

... More
Installation of flood lights at different heights including making suitable drills, minor cutting works etc as per site conditions and as directed by the EIC

50

-

-

... More
Identifying and rectification of faults including replacement of accessories for 18W to 1000 W street light luminaires of following types of mounting arrangement. Accessories include lamps, ballasts, Ignitor, Lamp holders, Starter, Starter Base, capacitors etc as per the detailed specification.(Refer Sec VI (MNC), Clause No.4).

-

-

-

... More
Street light Pole of height up to 11 meter and high masts.

25

-

-

... More
Post top lanterns/Bollards up to 4 mtr height/ luminaires at building top etc.

25

-

-

... More
Parking Shed.

10

-

-

... More
Identifying and rectification of faults for 18W to 1000 W street light luminaires/JB without accessories and as per the detailed specification. (Refer Sec VI (MNC), Clause No.4).

-

-

-

... More
Faults in street light luminaire of height up to 11 mtr and high masts

50

-

-

... More
Post top lanterns/Bollards up to 4 mtr height/ luminaires at building top etc

50

-

-

... More
Faults in Street light Junction Boxes/Parking shed

50

-

-

... More
Identification of cable fault in street & area lighting Network. Rectification of faults is not included under this item.

30

-

-

... More
Removal of RCC Straight / Single / Double Arm / "Y" Poles/Spun pole (8 Mtr to 14.5 Mtr height)/PTL from a location, transportation and re-installation of removed street light poles with lighting fixtures, junction boxes etc in specified location within a lead of 5 kms including excavation, back filing, providing 1:4:8 mudmat etc as per the detailed specification.(Refer Sec VI , Clause No.13.8).

-

-

-

... More
8 to 14.5mtr RCC straight/single/Y pole

10

-

-

... More
Post- Top lantern upto 4 mtr height

5

-

-

... More
Removal from a location, transportation and storage of removed poles in specified location(Refer Sec VI , Clause No.13.9).

-

-

-

... More
8 to 14.5 mtr RCC straight/single/Y pole

10

-

-

... More
Post top lantern upto 4mtr height

10

-

-

... More
Transportation from stockyard to new location, installation & commissioning of RCC Straight / Single / Double Arm / "Y" Poles/Spun pole (8 Mtr to 14.5 Mtr height)/PTL including transportation of JB, GI pipes, within a maximum lead of 5kms inlcuding excavation, 1:4:8 mudmat and back filling etc as per the detailed specification. (Refer Sec VI , Clause No.13.9).

-

-

-

... More
8 to 14.5 mtr RCC straight/single/Y pole

5

-

-

... More
Post top lantern upto 4mtr height

5

-

-

... More
Trimming Tree Branches near & around the Street Light Luminaire including disposal of removed branches to location within 3 kms specified by Engineer-in-Charge. Each street light pole will be considered as 1 No. for measurement. (Refer Sec VI (MNC), Clause No.7.1).

600

-

-

... More
Grass removal and creeper clearing around street lights and PTL for 1000 mm x 1000 mm area. (Refer Sec VI (MNC), Clause No.7.2).

1000

-

-

... More
Preventive Maintenance of Street Light control unit including replacement of damaged flexible wire, lugs etc wherever required. (Refer Sec VI (MNC), Clause No.9).

-

-

-

... More
Preventive Maintenance of Street Light control unit including replacement of damaged flexible wire, lugs etc wherever required including supply of cleaning materials and terminal ends (lugs). All other items required will be issued free of cost by the dept.

80

-

-

... More
Cement Washing and numbering of RCC pole after cleaning the surface as directed by the Engineer-in-Charge and as per the detailed specification. (Refer Sec VI (MNC), Clause No.10.1).

250

-

-

... More
Supply and painting One coat on metallic surfaces of electrical equipment and other required surface at all levels with primer and following paint (Asian or approved brand, colour and manufacturer) to give an even shade including preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-Charge. (Refer Sec VI (MNC), Clause No.3).

-

-

-

... More
Synthetic enamel Paint/Aluminium Paint

200

-

-

... More
Numbering of electrical equipments in following size and shape with synthetic enamel paint of different background colours, letter colour & size of letter as directed by Engineer in Charge (Refer Sec VI (MNC), Clause No.10.3).

-

-

-

... More
within 200mm dia/225 X 100mm area

500

-

-

... More
Patrolling of the street and area lighting system in IGCAR(Refer Section V)

150

-

-

... More
Collecting of scrap items and shifting more than 1 km and up to a distance of 5 kms. Measurement will be done on volume basis (Refer Sec VI (MNC), Clause No.28).

10

-

-

... More
Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)

120

-

-

... More
Supply, Loading, Transportation, Unloading at site, Laying, Testing and Commissioning of one number HRPVC insulated and PVC sheathed power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required. (Refer Sec VI, Clause No.3)

-

-

-

... More
4 CORE X 16 Sq.mm, 1.1kV grade AHYYWY CABLE

250

-

-

... More
Supply, Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade HRPVC insulated, Stranded Aluminium conductor armoured cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification. (Refer Sec VI, Clause No.3)

-

-

-

... More
4 CORE X 16 Sq.mm, 1.1kV grade AHYYWY CABLE

750

-

-

... More
Retrieval of the existing one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes laid direct in ground including Removal of end termination, excavation of trenches, retrieving of bricks and back filling as per the detailed specification.(Refer Sec VI, Clause No.5)

-

-

-

... More
3/3.5/4 Core Upto 25 Sqmm

200

-

-

... More
Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of end termination GI spacer, clamps etc as per the detailed specification. (Refer Sec VI, Clause No.5)

-

-

-

... More
3/3.5/4 Core upto 25 Sqmm

500

-

-

... More
Temporary laying of LT cables of following sizes in open air / in Built in trench. (Refer Sec VI (MNC), Clause No.30).

-

-

-

... More
Sizes up to 3.5C X 70 Sq.mm Aluminium conductor (Refer Sec VI (MNC), Clause No.30).

1000

-

-

... More
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).

-

-

-

... More
4 Core X10sqmm

50

-

-

... More
4 Core X 16 Sqmm

100

-

-

... More
3.5/4 C x 35 sq.mm

10

-

-

... More
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.4)The scope of work includes the supply of PVC Cable gland and crimping lugs.

-

-

-

... More
upto 3CX6Sq.mm

100

-

-

... More
Assisting in cable straight through or transition jointing of following size of cables by providing minor excavation, transportation of gas cylinder, jointing materials & tools, dressing the cable wherever required after job completion etc as per site condition and as directed by the Engineer-in-charge. (Refer Sec VI, Clause No.10.4)

-

-

-

... More
Voltage grade upto 1.1kV & size upto 120 sqmm/Telephone cable upto 50 Pair

30

-

-

... More
Supply and Installation of Cast aluminium Junction box with FRP cover /GFRP box and LDR control unit. (Refer Sec VI, Clause No.13.7).

-

-

-

... More
Supply the of GFRP box and LDR control unit installed at elevated level and as per the detailed specification.

10

-

-

... More
Supply and Installation of Cast aluminium Junction box with FRP cover. (Refer Sec VI, Clause No.13.6).

-

-

-

... More
Supply and Installation of Cast aluminium Junction box for PTL as per the drawing no: IGC/ESD/2021/6001/1-R1, for street light pole as per the drawing no: IGC/ESD/2021/6001/3, and as per the detailed specification.

30

-

-

... More
Supply, Installation, Testing and Commissioning of following area lighting luminaries on Metalic poles of height from 2.5 M to 4 M as per per the detailed specification. (Refer Sec VI, Clause No.16.1). - Catalogue No : LPTO-40-CDL-M and Lamp Type LED

25

-

-

... More
Supply and Installation of following general electrical items as per the detailed specification (Refer Sec VI (MNC), Clause No.5).

-

-

-

... More
63Amps, 500volts 4 way SS stud type Terminal block suitable for DIN rail mounting

50

-

-

... More
Supply Installation testing and commissioning of the following in Control Panel/JB/PTL/poles upto 4mtr/building tops etc.., including removal of existing components (Refer Sec VI (MNC), Clause No. 4)

-

-

-

... More
2 -10Amps, 415 Volts, NS type Knife Edge Off set HRC Fuse link

150

-

-

... More
16Amps, 415 Volts, Moulded HRC Fuse carrier.

50

-

-

... More
Servicing of ladder trolley ladder RKS -MODEL-510-JEEP TYRE TYPE (Refer Section V )

7

-

-

... More
Supply , installation, Testing and Commissioning of street light junction box as per the scope of work. (Refer Section V )

30

-

-

... More
Supply and installation of following Driver unit for LED street light fixtures as per the scope of work (Make : Phillips/Crompton) (Refer Section V )

-

-

-

... More
Phillips -XITANIUM-40 W -Model No. X040C070V058FNP1A0

10

-

-

... More
Crompton (SODRVQL -65- 700 -45 watts) / Suitable for LPTO-40-CDL PTL Fixtures

20

-

-

... More
Supply of LDR control unit and installation in Cast aluminium Junction box as per the detailed specification. (Refer Sec VI, Clause No.13.7).

5

-

-

... More
Servicing of flood light luminaires and supporting structure at various locations including supply & replacing of existing bolt with Stainless steel bolt, gasket and epoxy painting. (Refer Sec-V).

20

-

-

... More
Supply and installation of Following Sizes of PVC insulated, PVC round sheathed Multi core Flexible copper conductor cables to extend power from street light pole bottom JB to light fitting as per detailed specification.(Refer Sec VI, Clause No.12.5). Spacer and clamping is not required

-

-

-

... More
1100V PVC insulated, PVC round sheathed Flexible Copper Conductor cable of size 3 Core x 1.5 Sq.mm

200

-

-

... More
1100V PVC insulated, PVC round sheathed Flexible Copper Conductor cable of size 3 Core x 2.5 Sq.mm

200

-

-

... More
Cleaning and servicing of street light junction boxes including checking of loose connections in TBs, replacement of TBs if necessary and providing vermin proof arrangement as detailed in the scope of work. (Refer Section V)

300

-

-

... More
Removal of the Street light control box (Refer Sec VI (MNC), Clause No.19).

2

-

-

... More
Supply and installation of following sizes of HDPE Pipes Direct in Ground.

-

-

-

... More
Supply and installation of PLB 40/33mm HDPE Ducts including excavation for routing of Power /Telephone Cables as per the detailed specification.(Refer Sec VI, Clause No.4.1 & 4.2).

400

-

-

... More
Supply and installation of following sizes of PLB HDPE pipes on Floor, column, beams etc including chasing and replastering as per the detailed specification. (Refer Sec VI, Clause No.4.1 & 4.4).

-

-

-

... More
40/33mm PLB HDPE Pipes

100

-

-

... More
Supply, Installation, Testing and Commissioning of following Flood light luminaries on RCC/Metalic poles of height from 7 M to 12 M as per per the detailed specification. (Refer Sec VI, Clause No.16.1). - Catalogue No : BVP282 LED120 CW FG SY5WB 100W PSU or equivalent and Lamp Type LED

5

-

-

... More
Supply, Installation, Testing and Commissioning of following Flood light luminaries on RCC/Metalic poles of height from 7 M to 12 M as per per the detailed specification. (Refer Sec VI, Clause No.16.1). - Catalogue No : BVP283 LED181 CW FG SY5WB PSU or equivalent and Lamp Type LED

5

-

-

... More
Supply, Installation, Testing and Commissioning of following street light luminaries on RCC/Metalic poles of height from 7 M to 12 M as per per the detailed specification scope includes installation of external surge protection device wherever required. (Refer Sec VI, Clause No.16.1). - Catalogue No : Adornis Min 35W 4000k CCT NON DIM GREY (PC) PRIME 60 POLE DIA LED Item code STAN103540NDGYP00060 or equivalent and Lamp Type LED

30

-

-

... More
Supply, Installation, Testing and Commissioning of following street light luminaries on RCC/Metalic poles of height from 7 M to 12 M as per per the detailed specification scope includes installation of external surge protection device wherever required. (Refer Sec VI, Clause No.16.1). - Catalogue No : Adornis Min 60W 4000k LED, CCT NON DIM GREY (PC) PRIME 60 POLE DIA LED, Item code STA0N06040NDGYP00050 or equivalent and Lamp Type LED

15

-

-

... More
Supply, Installation, Testing and Commissioning of following street light luminaries on RCC/Metalic poles of height from 7 M to 12 M as per per the detailed specification scope includes installation of external surge protection device wherever required. (Refer Sec VI, Clause No.16.1). - Catalogue No : Adornis INT 100W 4000k CCT NON DIM GREY (PC) PRIME 50 POLE DIA LED, Item code STAOT10040NDGYP050C15 or equivalent and Lamp Type LED

10

-

-

... More
Supply and installation of Knob type panel lock by replaciong existing damaged/broken panel locks at various panels/st.light timer boxes as detailed in the scope of work. (Refer Sec V)

200

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.