Indira Gandhi Centre For Atomic Research Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Indira Gandhi Centre For Atomic Research - IGCAR Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Jan 2025
Closing Date21 Feb 2025
Tender Amount₹ 43,90,000 
Notes
Download

Costs

Summary

Maintenance For Lt Power Installations At Igcar, Kalpakkam For The Year 2025-26.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and replacing following earth pit chamber parts after removing and disposing off old/damaged part as per drawing No. IGC/ESD/5060/1008/1.

-

-

-

... More
RCC Top cover alone

5

-

-

... More
RCC ring Collar alone

5

-

-

... More
Painting of Distribution Equipments with ONE Coat of Primer, TWO Coat of Synthetic Enamel Paint including supply of paint & primer and required consumables .(Refer Sec VI (MNC), Clause No.3).

-

-

-

... More
Feeder Pillars - Type - A

5

-

-

... More
Feeder Pillars - Type-B

5

-

-

... More
Painting of 415V Switchboards with Two coats of synthetic enamel Paint including supply of paints and required consumables (Refer Sec VI (MNC), Clause No.3).

-

-

-

... More
Cubicle switch boards having number of vertical sections upto 3 (Refer Sec VI (MNC), Clause No.3).

5

-

-

... More
Cubicle switch boards having number of vertical sections above 3 and up to 6 (Refer Sec VI (MNC), Clause No.3).

5

-

-

... More
Cubicle switch boards having number of vertical sections above 6 (Refer Sec VI (MNC), Clause No.3).

5

-

-

... More
Supply and painting One coat on metallic surfaces of electrical equipment and other required surface at all levels with primer and following paint (Asian or approved brand, colour and manufacturer) to give an even shade including preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-Charge. (Refer Sec VI (MNC), Clause No.3).

-

-

-

... More
Synthetic enamel Paint

250

-

-

... More
Identification and rectification of shunt or series fault in main or sub distribution panel in labs / building as per the scope of work. (Refer Sec V)

-

-

-

... More
Minor fault

10

-

-

... More
Major fault

10

-

-

... More
Identification and rectification of shunt or series fault in 415 V, multi core cables of folowing sizes as per scope of work. (Refer Sec V)

-

-

-

... More
3.5/4 Core, size upto 25 Sqmm

5

-

-

... More
3.5/4 Core size above 120 Sq mm and upto up to 240 sqmm

20

-

-

... More
3.5/4 Core size above 240 sqmm and upto 400 sqmm

10

-

-

... More
3.5/4 Core size above 25 Sq mm and upto up to 120 sqmm

5

-

-

... More
Identification and rectification of shunt or series fault in lighting or power circuit wiring in labs / building as per scope of work. (Refer Sec V)

-

-

-

... More
Minor fault

15

-

-

... More
Major fault

5

-

-

... More
Supply and Installation of following Wiring Accessories as per the detailed specification (Refer Sec VI (MNC), Clause No.5).

-

-

-

... More
1 No 10A Switch on modular plate and termination of wires to the switches

250

-

-

... More
1 No16A Switch on modular plate and termination of wires to the switches

120

-

-

... More
1 No 6A 3 Pin shuttered type Socket on modular plate and termination of wires to the switches

200

-

-

... More
1 No 6/16A 3 Pin combined shuttered type Socket on modular plate and termination of wires to the switches

120

-

-

... More
Supply and Installation of following general electrical items as per the detailed specification (Refer Sec VI (MNC), Clause No.5).

-

-

-

... More
water proof stickers of 250 x 50 mm size with messages as directed by Engineer in charge

100

-

-

... More
3.0 mm thick white finish Hylam sheet covers for MS switch Boxes/ JBs of Sizes up to 400 x 400 mm as per the scope of work.

150

-

-

... More
Installation of the following items on M.S.frame work(Refer Sec VI (MNC), Clause No.6).

-

-

-

... More
63/100/200/315/400 Amps, 500 Volt, TPN Fuse Switch Unit.

5

-

-

... More
16/32/63 Amps, 500 Volt, TPN 4/8/12 Way Distribution Board

5

-

-

... More
Installation of the following items in 415V switch boards.(Refer Sec VI (MNC), Clause No.6).

-

-

-

... More
63/100/125Amps,500Volt,TP/TPN SFU/Combination FSU

5

-

-

... More
250/315/400/ 630 Amps, 500Volt,TP/TPN SFU/Combination FSU

5

-

-

... More
Removal of termination of armoured cables of following sizes from electrical equipment or reconnecting of removed termination

-

-

-

... More
Sizes upto 4C X 25 sq.mm

50

-

-

... More
Sizes above 4C X 25 sq.mm and upto 4C X 70 sq.mm

50

-

-

... More
Clearing light jungle area, bulb weeds, grass including removal all unwanted plants, branches, twigs, wild growth etc.complete, and disposing the same 100 meters away manually or burning them without disturbing other areas etc., complete all as directed by the Engineer-in-Charge. Contractor must inform the Engineer-in-charge and prior permission shall be obtained from him for burning the wild growth. (Refer Sec VI (MNC), Clause No.7.3).

600

-

-

... More
Supply and replacement of the following Metalclad Plug and Socket (Refer Sec VI (MNC), Clause No.12).

-

-

-

... More
230V, 20A, 2P+E Metalclad Plug and socket

10

-

-

... More
415V, 20A, 3P+E, Metalclad Plug and socket

20

-

-

... More
Operating the dewatering pump for dewatering cable trenches and related activities.

70

-

-

... More
Maintenance of Electrical Panel on EOT cranes/Feeder Pillar (Refer Sec VI (MNC), Clause No.17.2).

-

-

-

... More
Maintenance of Feeder pillar (Type-A)

8

-

-

... More
Maintenance of Feeder Pillar (Type-B)

8

-

-

... More
Maintenance of Feeder pillar (Type-C)

8

-

-

... More
Maintenance of Motor Control centres/Distribution Centres, LT panels/TPN switch Fuse Units (Refer Sec VI (MNC), Clause No.17.2).

-

-

-

... More
Cubicle switch boards having number of vertical sections up to 3

40

-

-

... More
Industrial LT panels

15

-

-

... More
Cubicle switch boards having number of vertical sections more than 3

35

-

-

... More
TPN switch fuse units upto 200Amps

70

-

-

... More
Combination Switch fuse Units from 16A to 400A /Motor starters

5

-

-

... More
Maintenance of Power and Lighting Distribution Boards located in various Buildings/Laboratories in IGCAR Complex (Refer Sec VI (MNC), Clause No.17.3).

-

-

-

... More
4/6 Way 16/32/63 Amps Fuse Distribution boards

25

-

-

... More
8/12 Way 16/32/63 Amps Fuse Distribution boards

25

-

-

... More
8/12 Way 16/32/63 Amps MCB Distribution Bards

270

-

-

... More
Removal of various sizes of MS box / switch box from the wall / panel (Refer Sec VI (MNC), Clause No.19).

150

-

-

... More
Removal of various sizes of surface mounted GI/ PVC Conduit from wall/column/beam and transportation to storage yard (Refer Sec VI (MNC), Clause No.19).

500

-

-

... More
Removal of the following from 415Volts switch boards (Refer Sec VI (MNC), Clause No.19).

-

-

-

... More
63A/100A/125A, 500V, TP/TPN/SFU/ Combination SFU or 4/6/8/12 Way SPN DB or 4/8 WAY TPN DBs

30

-

-

... More
250A/315A/400 A, TP/TPN/SFU/ Combination SFU or 12 Way TPN DBs

5

-

-

... More
Supply, open installation testing and commissioning of the following sizes of VTPN DBs on MS frame work (MS frame will be measured separately) as per the scope of work. (Refer Sec VI, Clause No.15.1).

-

-

-

... More
DB VTPN 8 Way (8 Plus 24) IP 43 - IK 09 Cat No:507727 or equivalent with 1No 125A,4P MCB incomer and 8Nos 32A,3P MCB

3

-

-

... More
DB VTPN 4 Way (8 Plus 12) IP 43 - IK 09 Cat No:507725 or equivalent , with 1 No.125A FP MCB and 4Nos 63A 3P MCB.

3

-

-

... More
Supply, open installation testing and commissioning of the following flexy DB with Double Door consisting of Phase, Neutral and Earth Bus and interconnecting wires. (MS item will be measured separately). (Refer Sec VI, Clause No.15.2).

-

-

-

... More
FLEXY DB 4 row of 14 modules IP 43 - IK 09 WITH METAL DOOR. Cat No:507707 or equivalent

2

-

-

... More
Supply, open installation testing and commissioning of the following DB with Double Door consisting of Phase, Neutral and Earth Bus and interconnecting wires. (MS item will be measured separately). (Refer Sec VI, Clause No.15.2).

-

-

-

... More
DB SPN 8 Way (8) WITH METAL DOOR IP 43 - IK 09 cat No:507611 or equivalent

5

-

-

... More
DB SPN 12 Way (12) WITH METAL DOOR IP 43 - IK 09 cat No:507612 or equivalent

15

-

-

... More
Supply, open installation testing and commissioning of the following sizes of cable end termination box on MS frame work (MS frame will be measured separately) as per the scope of work. (Refer Sec VI, Clause No.15.1.15).

-

-

-

... More
Cable End Box for IP 43 SPN 8 Way DB cat No:507913 suitable for SPN 8 Way DB cat No:507611

5

-

-

... More
Cable End Box for IP 43 SPN 12 Way DB cat No:507915 suitable for SPN 12 Way DB cat No:507612

15

-

-

... More
Cable End Box for IP 43 all Flexy DB/VTPN MCB DB cat No:507936 or equivalent

3

-

-

... More
Attending fuse off call in Power Points/ Power boards and minor faults in various Building / Laboratories (Refer Sec VI (MNC), Clause No.22).

400

-

-

... More
Disconnection of service connection with Energy meter board & shifting the board including connected cable. (Refer Sec VI (MNC), Clause No.27).

20

-

-

... More
Maintenance of service connection meter boards (including Energy meters and switch fuse units) (Refer Sec VI (MNC), Clause No.25).

20

-

-

... More
Collecting of scrap items and shifting more than 1 km and up to a distance of 5 kms. Measurement will be done on volume basis (Refer Sec VI (MNC), Clause No.28).

15

-

-

... More
Installation of Energy meter board & providing service connection at Various locations .(Refer Sec VI (MNC), Clause No.29).

-

-

-

... More
Installation of Energy meter board & providing service connection at Various locations.

25

-

-

... More
Temporary laying of LT cables of following sizes in open air / in Built in trench. (Refer Sec VI (MNC), Clause No.30).

-

-

-

... More
Sizes up to 3.5C X 70 Sq.mm Aluminium conductor (Refer Sec VI (MNC), Clause No.30).

4500

-

-

... More
Supply and installation of the following sizes of copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8)

-

-

-

... More
8SWG copper wire

300

-

-

... More
14 SWG Copper Wire

400

-

-

... More
Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc. (Refer Sec VI, Clause No.11).

-

-

-

... More
MS fabrication 1 coat primer & 2 coats synthetic enamel paint

500

-

-

... More
Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)

80

-

-

... More
Supply and external installation of following sizes of Heavy Duty, Hot Dip Galvanised MS ERW Conduits for Electrical & Communication System with all the required accessories like round JBs, Solid Long Bends, Check Nuts, Nipples, Couplings, Reducers, Copper Clips, Copper Conductor, GI Wire etc. as per the detailed specification. .(Refer Sec VI, Clause No.27).

-

-

-

... More
20mm dia 1.6mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes.

100

-

-

... More
25mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes.

500

-

-

... More
32mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes.

150

-

-

... More
25mm GI Flexible Hose

200

-

-

... More
Supply and external installation of following sizes of Heavy Duty, PVC circular rigid Conduits for Electrical & Communication System with required Solid Long Bends, Couplings, GI Wire etc, as per the detailed specification.(Refer Sec VI, Clause No.27).

-

-

-

... More
25mm Dia, 2mm wall thickness PVC heavy duty round rigid conduits with 50mm deep Junction boxes

150

-

-

... More
Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification. (Refer Sec VI, Clause No.29)

-

-

-

... More
25 X 12 mm size of PVC Mini trunking

400

-

-

... More
Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification. (Refer Sec VI, Clause No.18)

-

-

-

... More
Wiring with 1 Run of 1.5 Sq.mm Copper wire

2500

-

-

... More
Wiring with 1 Run of 2.5 Sq.mm Copper wire

4000

-

-

... More
Wiring with 1 Run of 4 Sq.mm Copper wire

1000

-

-

... More
Wiring with 1 Run of 6 Sq.mm Copper wire

100

-

-

... More
Wiring with 1 Run of 10 Sq.mm Copper wire

100

-

-

... More
Wiring with 1 Run of 16 Sq.mm Copper wire

100

-

-

... More
Wiring with 1 Run of 25 Sq.mm Copper wire

100

-

-

... More
Wiring with 1 Run of 35 Sq.mm Copper wire

100

-

-

... More
Installation of MS boxes of the following types and as specified on MS frame/Wall as per the detailed specification. (Refer Sec VI, Clause No.15.10.8).

-

-

-

... More
MS/GI box of size above 200(W) x 200(H) x 150(D) and up to 300(W) x 300(H) x 200(D)mm, 1.8mm thick

150

-

-

... More
Shifting of Electrical equipment of various sizes including loading and unloading/Shifting of electrical/telephone items from IGCAR and hand over to service centres (upto chennai limit) or vice versa.(Refer Sec VI (MNC), Clause No.31).

-

-

-

... More
Heavy Electrical equipment (more than 500 kg and upto 5 Tons) within a distance of 5 kM

15

-

-

... More
Loading, Transportation, Unloading at site, Laying, Testing and Commissioning of one number PVC/HRPVC/XLPE insulated and PVC sheathed Stranded Aluminium/copper conductor power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)

-

-

-

... More
3/3.5/4 Core X upto 25 Sqmm

100

-

-

... More
3/3.5/4 Core X above 25 to 3/3.5/4 Core X up to 120 sqmm

200

-

-

... More
3/3.5/4CX Above 120 Sq.mm but not exceeding 3.5/4CX 240 sq.mm

200

-

-

... More
3/3.5/4 Core X Above 240 sqmm to 3/3.5/4Core X 400 sqmm

150

-

-

... More
Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)

-

-

-

... More
3/3.5/4core X Upto 25 sqmm

500

-

-

... More
3/3.5/4Core X above 25 & up to 120 sqmm

300

-

-

... More
3/3.5/4Core X above 120 & up to 240 sqmm

150

-

-

... More
3/3.5/4Core X above 240 & up to 400 sqmm

50

-

-

... More
Retrieval of the existing one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes laid direct in ground including Removal of end termination, excavation of trenches, retrieving of bricks and back filling as per the detailed specification.(Refer Sec VI, Clause No.5)

-

-

-

... More
3/3.5/4 Core Upto 25 Sqmm

100

-

-

... More
3/3.5/4 Core Above 25sqmm & upto120 sqmm

150

-

-

... More
3/3.5/4 Core Above120sqmm & upto240 sqmm

100

-

-

... More
3/3.5/4 Core Above 240sqmm & upto 400 sqmm

100

-

-

... More
Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of end termination GI spacer, clamps etc as per the detailed specification. (Refer Sec VI, Clause No.5)

-

-

-

... More
3/3.5/4 Core upto 25 Sqmm

150

-

-

... More
3/3.5/4 Core Above 120 & Upto 240 Sqmm

100

-

-

... More
3/3.5/4 Core Above 120 & Upto 240 Sqmm

100

-

-

... More
3/3.5/4 Core Above 240 & Upto 400 Sqmm

50

-

-

... More
Retrieval of the already laid one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes laid direct in ground including removal of end termination, excavation of trenches, retrieving of bricks, back filling and Re - laying the same cable direct in ground by using retrieved bricks including transportation of cables, excavation and backfilling of soil, supply of sand & shortage bricks etc as per the detailed specification. (Refer Sec VI, Clause No.7)

-

-

-

... More
3/3.5/4 Core Upto 25 sqmm

100

-

-

... More
3/3.5/4 Core Above 25sqmm & upto120 sqmm

100

-

-

... More
3/3.5/4 Core Above 120sqmm & upto 240 sqmm

100

-

-

... More
3/3.5/4 Core Above 240sqmm & upto 400 sqmm

100

-

-

... More
Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of GI spacer, clamps etc and relaying the same cable in built-in trenches, on walls, poles and through embedded pipes using the retrieved spacer & clamp & supplying the shortage spacer & clamp if any as per the detailed specification. (Refer Sec VI, Clause No.7)

-

-

-

... More
upto 3/3.5/4 C X 25 Sqmm

100

-

-

... More
3/3.5/4 Core Above 25 & Upto 120 Sqmm

100

-

-

... More
3/3.5/4 Core Above 120 & Upto 240 Sqmm

50

-

-

... More
3/3.5/4 Core Above 240 & Upto 400 Sqmm

50

-

-

... More
End Termination of the following size Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).

-

-

-

... More
4C x 2.5 Sq.mm including cable gland earthing

40

-

-

... More
4C x 10 Sq.mm including cable gland earthing

25

-

-

... More
4C x 16 Sq.mm including cable gland earthing

40

-

-

... More
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).

-

-

-

... More
4 Core X10sqmm

10

-

-

... More
4 Core X 16 Sqmm

20

-

-

... More
3.5/4 C x 35 sq.mm

40

-

-

... More
3.5/4C x 50/70 sq.mm

30

-

-

... More
3.5 x 95/120 sq.mm

10

-

-

... More
3.5 x 185 sq.mm

10

-

-

... More
3.5 x 240 sq.mm

4

-

-

... More
3.5 x 400 sq.mm

4

-

-

... More
Shifting of Electrical equipment of various sizes including loading and unloading/Shifting of electrical/telephone items from IGCAR and hand over to service centres (upto chennai limit) or vice versa.(Refer Sec VI (MNC), Clause No.31).

-

-

-

... More
Items weighing upto 10kg

15

-

-

... More
Items weighing above 10kg and upto 50kg

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.