Indira Gandhi Centre For Atomic Research Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Indira Gandhi Centre For Atomic Research - IGCAR Tender

Works
Electrical and Electronics
Eprocure
Opening Date31 Jan 2024
Closing Date16 Feb 2024
Tender Amount₹ 14,10,731 
Notes
Download

Costs

Summary

Annual Maintenance Of Electrical Systems And Equipments In Pied And Associated Buildings, Igcar For The Year Of 2024-25.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Replacement of following fluorescent/CFL/Incandescent light fitting accessories, including attending of loose connection etc upto 2.05 Fluorescent tube light

400

-

-

... More
Fluorescent tube light starter

300

-

-

... More
Choke 40/65W

175

-

-

... More
Tube light holder/bracket single or double, starter

100

-

-

... More
Incandescent lamp/CFL

30

-

-

... More
Replacement of following accessories in 250/400 watts MV lamp/ballast/ capacitors/lamp holder etc in the light fittings at highbay area of Labs.

3

-

-

... More
Replacement /New flush/concealed type switches & sockets, MCBs upto 4Nos.of 5/15 amps in the MS boxes in various locations of the lab.

50

-

-

... More
Rectification of faults such as earth fault, loose connections, changing of defective wires, components etc in Post top lantern, light fittings in & around RML

425

-

-

... More
Preventive maintenance of Air conditioning power supply switch boxes in various locations including MCBs/ Industrial switches & sockets/ELCBs etc.and functional test of the same as directed by the Engineer-in-charge.

61

-

-

... More
Replacement/repair of faulty Public addressing system speakers and telephone line points in concealed/conduit type and in MS boxes in various locations of the lab.

300

-

-

... More
General Cleaning of Main panels, PCCs, MCCs, & HT panel surfaces and rubber mats as per the scope of work.

144

-

-

... More
General Cleaning of Transformers/DG sets/Telephone Exchange MDF panel,UPS,Power supply,PA Amplifiers etc.

120

-

-

... More
Intra movement of various electrical items, components and equipments in different electrical stores in RML complex and buildings and sort out of electrical items in stores on day to day basis for various works

510

-

-

... More
Maintenance of Power and Lighting Distribution Boards located in various buildings/Laboratories as per the scope of work and as directed by the Engineer-in-charge upto 8.03.4/6 Way 16/32/63 Amps. Distribution Boards

14

-

-

... More
8 Way 16/32/63 Amps. Distribution Boards

41

-

-

... More
12 Way 16/32/63 Amps. Distribution Boards

22

-

-

... More
Cleaning of battery surfaces, filling of distilled water and recording the values monthly as directed by the Engineer-in-charge.

72

-

-

... More
Installation of 19mm/25mm PVC Trunking (Casing & capping) as per the scope of work and directed by the Engineer-in charge.

80

-

-

... More
Collection/disposal of electrica l/other consumable and spares from/to central stores as directed bythe Engineer- in charge.

8

-

-

... More
Monitoring and recording the LT/HT panel reading and Transformer temperature as directed by the Engineer in- charge.

240

-

-

... More
Breakdown maintenance of MCC and plant equipments etc. Upto 13.02 Retermination of power cable at motor and starter side 6-35 sq.mm

10

-

-

... More
Retermination of power cable at motor and starter side 35-95 sq.mm

5

-

-

... More
Preventive maintenance of Electrical panel as per scope of works upto 14.13 Main panel consists of 2 incomer ACBs, outgoing of 17 Nos. TPN, ACBs Switches, etc.

2

-

-

... More
Mains distribution panels consists of 1/2 incomer,13 to 20 outgoings

4

-

-

... More
Mains distribution panels consists of 1/2 incomer, 6 to 12 outgoing

11

-

-

... More
Mains distribution panels consists of 1 incomer, 1 to 5 outgoing

13

-

-

... More
Hot cell control desk, lighting/power circuits, MSM power circuits.

8

-

-

... More
Individual starter compartment upto 10 HP motor

24

-

-

... More
Individual starter compartment above 11 HP to 40 HP motor

21

-

-

... More
Individual starter compartment above 41 HP to 100 HP motor

10

-

-

... More
Incell crane panel, Power Manipulator panel , VTS panel

8

-

-

... More
Battery operated vehicles

24

-

-

... More
Main HT panel consists of 1 incomer VCB, outgoing of 2 Nos.VCBs

1

-

-

... More
Ph-I plant room RCP1 & 2 and cell door drive control panel for hot cell

10

-

-

... More
Functional test of wall mount Emergency lamps at various locations monthly once as directed by the Engineer-in-charge

24

-

-

... More
Laying of 3 or 4 core 2.5/4/6/10 Sq.mm armoured/ unarmoured cables in inbuilt trench / wall area/trays& PVC/ XLPE armoured cables in hume pipe/built-in -trenches/on the walls/trays as per the scope of work and as directed by the Engineer-in-charge.

125

-

-

... More
End termination of 3 or 4 core 2.5/4/6/10 Sq.mm copper/ aluminum control/power armoured cables

16

-

-

... More
Earth pit maintenance in different locations around RML lab

44

-

-

... More
Painting of Electrical panels/eqpts/machineries/ accessories/ chequer plates including supply of all as per the scope of work.

50

-

-

... More
Overhauling and Preventive maintenance of various capacity motors as per scope of work upto 18.05. Ceiling fans/Pedestal fans/Exhaust fans of rating upto 100 W

4

-

-

... More
Ceiling fans/Pedestal fans/Exhaust fans of rating upto 400 W

3

-

-

... More
Air monitor vacuum pump motor 1 Ph rating upto 2.HP

2

-

-

... More
Motors of capacity upto 3.0 HP to 5.0 HP

2

-

-

... More
Motors of capacity upto 6.0 HP to 10.0 HP

3

-

-

... More
Rewinding and maintenance of various capacity motors as per scope of work upto 19.05. Ceiling fans/Pedestal fans/Exhaust fans of rating upto 100 W

2

-

-

... More
Ceiling fans/Pedestal fans/Exhaust fans of rating upto 400 W

1

-

-

... More
Air monitor vacuum pump motor 1 Ph rating upto 2.HP

1

-

-

... More
Motors of capacity 7.5 HP

1

-

-

... More
Motors of capacity 10 HP

1

-

-

... More
Wiring with new copper conductor wire of 2X1.5/2.5/4 Sq.mm PVC insulated wires and bare copper for earth as per the scope of work. Laying of new MS/GI conduit /flexible conduit pipe and wiring in the office areas and plant areas as per the scope of work and as directed by the Engineer-in-charge.

150

-

-

... More
Installation,testing and commissioning of reputed make LED fittings at RML complex and other areas as directed by Engineer-in-Charge upto 21.03. Supply,Installaion,tetsing & Commissioning of reputed/ branded 30 W indoor type LED square surface down lights with mid power LEDs as light source & exclusively designed Extruded Aluminium frame with powder coating along with electronic driver at RML indoor premises and annex building area etc. as directed by the Engineer-in-Charge.

6

-

-

... More
Supply,Installaion,tetsing & Commissioning of reputed/ branded 38/45 W indoor type LED square surface/recessed down lights with mid power LEDs as light source & exclusively designed Extruded Aluminium frame with powder coating along with electronic driver at RML indoor premises and annex building area etc. as directed by the Engineer-in-Charge.

4

-

-

... More
Supply,Installaion,tetsing & Commissioning of reputed/ branded 45 W indoor type LED rectangle surface/recessed down lights with mid power LEDs as light source & exclusively designed Extruded Aluminium frame with powder coating along with electronic driver at RML indoor premises and annex building area etc. as directed by the Engineer-in-Charge.

32

-

-

... More
Overall rebate (Optional)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.