Indira Gandhi Centre For Atomic Research Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Indira Gandhi Centre For Atomic Research - IGCAR Tender
Civil And Construction
Building Construction
Eprocure
Opening Date26 Jun 2024
Closing Date7 Aug 2024
Tender Amount₹ 79,55,000
Costs
EMD
₹ 1,59,100Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IGCAR_813690_1Bid Award Id
ViewTender No
CEG/IGC/2016/2024Tender Authority
Indira Gandhi Centre For Atomic Research ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Undertaking and form of tender
Forms A C D F G H for filling and uploading
BOQ Items
All kinds of soil with depth upto 1.5m below average Ground level and disposing surplus excavated earth upto a lead of 50 metres.
365
-
-
All kinds of soil with depth exceeding 1.5m but not exceeding 3m below average Ground level and disposing surplus excavated earth upto a lead of 50 metres.
65
-
-
All kinds of soil with depth exceeding 3m but not exceeding 4.5m below average Ground level and disposing surplus excavated earth upto a lead of 50 metres.
15
-
-
Earthwork excavation by mechanical means (Hydraulic excavator) / manual means for foundation, substructures, plinth beam, cess pits & trenches all kinds of foundation etc., in soft rock for the following depth from average ground level upto the required line, level and grades in both dry and wet conditions including shoring, strutting, bailing out of water if necessary, levelling and ramming the bottom of trenches, dressing of sides, stacking the excavated materials away from the edge of trenches, refilling the sides of foundation as required with selected excavated earth and depositing / disposing the surplus earth (Disposed soil to be levelled by breaking clods, if any and neatly dressed and levelled) with an lead specified below and stacking the soft rock boulders in a neatly levelled ground for measurement to departmental gauge all complete as per specifications and as directed by the Engineer-in-charge.
-
-
-
All kinds of soft rock with depth upto 1.5m below average Ground level and disposing surplus excavated earth upto a lead of 50 metres.
2
-
-
All kinds of soft rock with depth exceeding 1.5m but not exceeding 3m below average Ground level and disposing surplus excavated earth upto a lead of 50 metres.
2
-
-
Supplying and filling in basement with Quarry dust, filling in layers of not more than 150mm thick, each layer well rammed and consolidated by hand/mechanical roller including watering, levelling, dressing the top surface to the required level complete all as per specification and as directed by the Engineer-in-charge.
50
-
-
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete in all respects as per clause 406 of MoRT&H specifications for road and bridge works (4th Revision or latest) and as directed by the Engineer-in-charge.
50
-
-
Supplying and injecting with approved quality chemical emulsion at the rate 1:29 ratio (1 part of chemical and 29 parts of water) and concentrations as per IS 6313-2001 Part II for preconstructional anti termite treatment and creating a chemical barrier under and alround the masonry pits, masonry foundations, wall trenches, plinth filling, junctions of wall and floor, expansion joints, surfaces of RCC works for a depth of min. 500mm from the finished ground level, surrounding of pipes, conduits etc., walls retaining soil above floor level, apron and drain along the perimeter of the building including all complete as per specification / IS 6313:2001 and direction of Engineer-in-charge. Only ground floor plinth area of the building will be measured for the payment in the following three stages. i) 20% after completion of the foundations ii) 50% after completion of the ground floor flooring iii) 30% after completion of all treatment works including ground floor doors & windows. Work to be executed by M/s Pest Control (India) or any other approved agency and specified guarantee for 10 (Ten) years shall be furnished by the tenderer. Payment will be cleared only after submission of Guarantee.
100
-
-
Providing and laying plain cement concrete 1:3:6 using 40mm maximum size graded aggregates and crushed stone sand including mechanical mixing, transporting and placing in required position, ramming, compaction, levelling, curing, shuttering, dewatering if any, complete all as per specification for levelling courses in foundation for walls, footings, floor drains etc., encasing pipes and other required works directed by Engineer-in-charge complete all as per specifications.
15
-
-
Supplying, fabricating, erecting and fixing in position at all levels, centering and shuttering to correct line and levels including strutting, propping, etc., with necessary bracings in all axes to give a stable assembly with provision for making the joints in the shuttering fully leak proof and with provision for fixing coil nuts with tie rods along with suitable channel for lateral supports and for inserts, projecting dowels, anchor bolts or any other fixture, including staging, access and working platforms etc., all complete as specified and directed including dismantling and removing the aforesaid assembly after the concrete attains the sufficient strength to self-support itself without cracking and distortion all as per specification, including all materials and labour complete in all respects at all lifts. The measurement for the formwork will be the actual area of forms in contact with concrete surfaces. Shuttering with plywood panels alone will be permitted.
250
-
-
Supplying, fabricating, erecting and fixing in position at all levels, centering and shuttering for curved surface to correct line and levels including strutting, propping, etc., with necessary bracings in all axes to give a stable assembly with provision for making the joints in the shuttering fully leak proof and with provision for fixing coil nuts with tie rods along with suitable channel for lateral supports and for inserts, projecting dowels, anchor bolts or any other fixture, including staging, access and working platforms etc., all complete as specified and directed including dismantling and removing the aforesaid assembly after the concrete attains the sufficient strength to self-support itself without cracking and distortion all as per specification, including all materials and labour complete in all respects at all lifts. The measurement for the formwork will be the actual area of forms in contact with concrete surfaces. Shuttering with plywood panels alone will be permitted.
205
-
-
Providing and laying cast insitu controlled reinforced cement concrete of specified grade at all levels and lifts mentioned below using 20mm maximum size hard granite machine crushed graded stone aggregates and crushed stone sand including weigh batching, charges for mixing & cost of admixture, mechanical mixing, transporting and placing at all lifts, vibrating, consolidating, curing and finishing smooth of all exposed faces complete for column footings, columns, lintels, sunshades, gutter slabs, beams, slabs, water tank, machine foundation and all other structural elements including dewatering wherever necessary (Formwork and reinforcement will be paid for separately) all as per specification and all as shown in drawings and as directed by the Engineer-in-charge for all insitu item.
Note: 1. The rate of concrete shall include all labour, equipment, charges for mixing & cost of admixture. Chemical admixture confirming to IS 9103 shall be mixed in fresh concrete and prior permission from Engineer-in-charge shall be obtained for dosage and compatibility. 2. Test certificate of cement, procured from dealer/company to be submitted for all cement related works by the Contractor. 3. The rate shall be quoted on the basis of using minimum cement per cu.m. of concrete mentioned below for relevant grade of concrete. Any upward/downward variation required to obtain the specified strength will be paid for or deducted at the rate of cement specified in Schedule F.
-
-
-
M30 grade with 370 kg. of cement per cu.m. of concrete upto plinth level
80
-
-
M30 grade with 370 kg. of cement per cu.m. of concrete for all floors
30
-
-
Providing, straightening, decoiling wherever necessary bending, cutting, binding and fixing in position steel reinforcement TMT bars of Fe500D grade steel conforming to IS:1786 'SAIL or VIZAG or approved equivalent make' and tying with approved annealed binding wire of 1.6mm dia in all reinforced cement concrete work at all lifts, including cost of supplying and fixing the spacer/cover blocks in cement mortar 1:2 and binding wire complete all as per specification and as directed by the Engineer-in-charge at all lifts.
Note: The rate shall be including the cost of reinforcement steel. The reinforcement steel will be procured from dealers with a test certificate as approved by the department. For further details please see point 7 of Section VIII, General Information for Guidance of Tenderers.
13
-
-
Manufacturing, supplying, hoisting and fixing in position at all lifts, precast units of various patterns and sizes for precast plain solid units, slabs, exhaust fan moulds etc., in reinforced cement concrete of 1:2:4, using 20mm and below machine crushed graded stone aggregate and crushed stone sand including weigh batching, mechanical mixing, casting, vibrating, finishing of exposed faces, curing, necessary formwork & moulds, transporting and placing at all lifts, preparation of connections, grouting with cement mortar/cement grout wherever needed excluding steel reinforcement complete all as per drawing, specification and as directed by the Engineer-in-charge.
3
-
-
Providing and constructing brick masonry at all lifts using well burnt stock bricks in cement mortar 1:6 using crushed stone sand including scaffolding, raking out joints, curing complete as per specifications and drawings for foundation, superstructure, etc. for the following floors.
-
-
-
for Basement and Ground Floor
20
-
-
Providing and fixing anodized aluminium (Anodised transparent or dyed to required shade according to IS:1868 Minimum Anodic coating of grade AC 15) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z Sections and other sections of approved make confirming to IS:733 and IS:1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per architectural drawings and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required. (fittings, Glazing and panelling shall be paid for separately)
Note : 1) The rates for aluminium is inclusive of all fasteners required for fabrication and fixing in the walls. 2) All joints shall be of mittered Joints. 3) A long M.S rod threaded at both ends to be provided in all aluminium door shutters in Top & bottom Horizontal members internally connecting Vertical members and fixed with M.S washers & nuts. 4) Only Aluminium members alone shall be measured and paid for.
260
-
-
Providing, supplying, cutting, bending to shape, welding, fabricating, hoisting, placing and fixing in position structural steel members like MS structural embedment’s/pipe and sleeves/penetration etc. using MS angles, channels, I-sections, plates, tees, flats, rounds, square sections etc. including chamfering and rounding off the edges, applying a coat of Red lead paint primer / Zinc chromate primer of approved make and 2 coats of flat oil paint / synthetic enamel paint of approved colour and make, scaffolding and staging required for fabrication as well as erection complete all as per specifications, drawings and as directed by the Engineer-in-charge.
Note: Lifting device arrangements if any required shall also be arranged by the contractor at his own cost.
3.8
-
-
Supplying and laying water proofing treatment of Polymer modified water proofing membrane treatment for vertical surface & inclined surface of underground surfaces and basement inclusive of surface penetration, labour, tools, equipment materials etc all complete as per manufactures specification, drawing and as directed by the engineer consisting of following 1. First coat of acrylic based polymer modified cementicious composite mortar 2. First layer of fibre glass cloth reinforcement.
3. Second coat of acrylic based polymer modified cementious composite mortar
4. 20mm thick protective layer of 1:5 cement sand using crushed stone sand with approved water proofing compound.
300
-
-
Providing plastering to the internal surfaces of brickwork/concrete at all elevations in cement mortar 1:5 using crushed stone sand, 12mm thick finished with a floating coat of neat cement including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, forming grooves wherever necessary, all as per specifications.
75
-
-
Providing plastering to the external surfaces of brickwork/concrete at all elevations in cement mortar 1:5 using crushed stone sand, 12mm thick including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, forming grooves wherever necessary, all as per specifications.
175
-
-
Providing and fixing glazing with 5mm thick clear Float glass pane in aluminium doors, window, ventilator shutters and partitions etc. with Neoprene gasket including cost of neoprene gasket complete as per the drawings and directions of the Engineer-in-charge.
10
-
-
Providing and fixing IS:12817 marked stainless steel butt hinges of size 125 x 64 x 2.5mm (heavy weight) "GARG" or equivalent approved make with suitable stainless steel screws etc. complete all as per specifications and as directed by the Engineer-in-Charge.
16
-
-
Providing and fixing Stainless Steel tower bolts of size 250 x 12mm "GARG" or equivalent approved make with necessary screws etc. all as per specifications and as directed by the Engineer-in-charge.
4
-
-
Providing and fixing Anodised Aluminium handles 75mm with plate 125 x 32mm including fitting with necessary screws complete all as per specification and as directed by the Engineer-in-charge. Sample to be approved by the Engineer-in-charge.
4
-
-
Providing and fixing approved quality Stainless steel body Roller wheels of approved make for Sliding door shutters all as directed by the Engineer-in-Charge.
6
-
-
Providing and laying 20mm thick Indian patent stone flooring and skirting with cement concrete 1:2:4, using 10mm and below size hard broken granite stone jelly and crushed stone sand including dividing strips, laying in panels, consolidating, curing, rubbing the surface smooth, cleaning the surface neatly at the time of handing over the area complete all as per specifications and as directed by the Engineer-in-Charge.
30
-
-
Providing and applying painting Two coats at all levels with Acrylic emulsion paint (Asian or Equivalent approved brand, colour and manufacturer) to give an even shade including one under coat of suitable primer, applying putty, preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-charge.
175
-
-
Providing and applying painting Two coats at all levels with premium Plastic emulsion paint (Asian or Equivalent approved brand, colour and manufacturer) to give an even shade including one under coat of cement primer, applying putty, preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-Charge.
60
-
-
Providing and Painting with Epoxy paint (two or more coats) using APCODUR-CF-641 finishing coat at all locations prepared and applied as per manufacturer' specifications including a priming coat if specified by the manufacturer, preparation of surface and etching with 10% commercial Hydrochloric acid wherever necessary and neutralizing the acid etched areas by washing with 5% solution of soda ash neatly and washing with sufficient water, after first coat Epoxy based trowelling compound if required, including preparation of the surface by scrapping, applying sand paper, filling the holes, joints, cracks if any, etc. complete all as per manufacturers Technical Data and as directed at site to achieve 200micron Dry film thickness (50 Micron Primer coat and 150micron finishing Coat). (Contractor has to provide Elcometer sampling sheets etc. at his cost for testing film thickness)
70
-
-
Providing, Laying, jointing, fixing and testing for following diameter of Exposed on wall plumping lines Heavy quality (C-Class) Galvanized Iron pipes of TATA or approved equivalent make and ISI marked fittings like, tees, elbows, bends, unions, nipples, reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.cm hydraulic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing Teflon tape, fixing in walls / trenches using clamps etc. including 2 coats of Synthetic enamel paint over a coat of primer, complete all as per specifications and drawings, all as directed at site. Pipes with exclusive use of ISI marked of approved make C-Class pipes.
-
-
-
20mm n/b G.I pipe
30
-
-
25mm n/b G.I pipe
10
-
-
32mm n/b G.I pipe
10
-
-
40mm n/b G.I pipe
50
-
-
Providing and constructing Random Rubble masonry in cement mortar 1:6 using crushed stone sand and using hard granite stones obtained from approved quarry with bond stones at 2.00 metres apart for foundation, basement and in superstructure, compound/boundary walls, including sizing of stones if required, raking out joints, scaffolding, curing etc., complete all as per drawing, specifications and as directed by the Engineer-in-charge at all lifts.
30
-
-
Providing Flush pointing over the random rubble masonry wall with cement mortar 1:3 using crushed stone sand at all levels including scaffolding, curing, forming grooves wherever necessary all as per specifications, drawings and as directed by the Engineer-in-charge.
150
-
-
Providing and fixing G.I. chain link fencing conforming to IS:2721 of required width in mesh size 50x50mm, made of G.I. wire 3.15mm diametre including strengthening with top and bottom line wire 4mm diametre, (4mm diametre line wire at top, bottom & middle to be provided incase fencing height exceeds 2m) cutting of chain link & wires to required length, spreading, fixing & binding chain link to fencing post with 18 gauge binding wire including cost of GI bolts and washers and wire etc., complete in all respects all as per specifications & directed by the Engineer-in-charge.
200
-
-
Supplying and fixing in position of heavy quality Cast Iron manhole frame and cover, steps etc. of specified weight for the inspection chamber, valve chamber etc. all as per specifications and as directed by the Engineer-in-charge.
150
-
-
Demolishing Stone rubble masonry in cement mortar at all levels by manually / by mechanical means, carefully without damaging adjacent structures including stacking of serviceable materials and disposal of unserviceable materials within 50m lead as per direction of the Engineer-in-charge.
20
-
-
Dismantling of RCC works at all levels by manually / by mechanical means, including cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 50m lead as per specifications and directed by the Engineer-in-charge.
5
-
-
Dismantling Brick work in cement mortar at all levels by manually / by mechanical means, carefully without damaging adjacent structures including stacking of serviceable materials and disposal of unserviceable materials within 50m lead all as per specifications and directed by the Engineer-in-charge.
7
-
-
Providing and fixing roofing sheet, cladding with 0.47mm thick colour coated concelled system profile corrugated/semi corrugated/plain zincalume sheets of 55mpa yield stress (AS 1397 – Zincalume AZ 150) with coating class AS/NZS 2728 (minimum 150 grams per relevant standard) having a total coating thickness of 35 micron. The sheet should be rolled over specially designed concealed fixing clip manufactured from hi-tensile Aluminium Zinc alloy Zincalumen steel based and galvanized hooks. The clip should be fastened with minimum 40micron Zinc coated / minimum 25micron Zinc-Tin alloy coated. The rate is inclusive of all fixtures required for fixing the side roof, cladding on all sides, ridges etc. complete all as per specification and as directed by the Engineer-in-charge.
60
-
-
Conveying the surplus excavated earth & debris, boulders and spoil by mechanical means and depositing at places inside DAE installation identified as Dumping yard as per requirement with a lead specified below including loading, unloading, breaking clods, levelling all complete as per specification and as directed by the Engineer-in-charge.
Note: 1) The rates in respect of this Item are applicable for the NET Quantities arrived at after making deductions for voids @ 20% in respect of soil and @ 50% in respect of Rock from the corresponding Stack / Truck measurements. 2) The earth shall be dumped well inside the Dumping yard and not over approach pathway road. - Lead charges for lead Exceeding 4 kilometre but not exceeding 5 kilometre
250
-
-
Providing and laying non pressure NP2 class RCC Hume pipes conforming to IS:458, with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 using crushed stone sand, laying to the levels, slopes including testing of joints etc. complete all as per the drawings and specifications and as directed by the Engineer-in-charge.
-
-
-
150mm dia NP2 class RCC Hume pipe
50
-
-
225mm dia NP2 class RCC Hume pipe
30
-
-
Supplying, fabricating, installing, placing and securing in position steel grills for windows comprising of square bars / MS flats as per detailed drawing including cutting, bending to shape, welding, painting with two coats of synthetic enamel paint of approved colour over one coat of primer complete all as per specification and drawings and as directed by Engineer-in-charge.
200
-
-
Levelling, bull-dozing the heeped/ dumped loosened earth/ debris etc., by hiring JCB/Bull-dozer etc., including labour if any required as directed by Engineer-in-Charge.
20
-
-
Supplying and fixing of waste mixer / grinder for grinding of the food waste and mixing with the water before feeding to the digester of grinding capacity 500 kgs/hr with motor rating 2 HP of make sharp or other approved equivalent make with motor and accessories suitable for Bio gas plant made up of ss 304 grade shredder plate with sink (hopper) mounting on ss free standing.
1
-
-
Supplying and fixing of heavy duty slow speed portable Air compressor suitable for Bio gas plant of lubricated, air colled and belt driven type with 1/1 cylinder/stage, 8 kg/cm2 maximum pressure, 9 PD (CFM), 800 COMP RPM, having 2 HP motor and 150 litre tank capacity including standard accessories like Intake filter, Non return valve, Drain cock, V.Belt, belt guards, fly wheel, pulley set pressure switch & gauge, safety and delivery valve motor and starter, special accessories like mounted on 2 axles and 4 wheels for portability of approved make.
1
-
-
Supply, installation and commissioning of submersible pump with solids handling capacity specially designed to withstand wide voltage fluctuations in 3 phases supply, motor is water cooled and fitted with good quality oil seal, Total Head is 12meters (min),capacity is 10KL/hr ( min ),motor capacity is 3 phases, 2 H.P, Temperature is Ambient, pipe size is 65 X 50mm, speed is 2900 RPM (approx),Rotation is clockwise when viewed from motor end, Motor is totally enclosed water filled squirrel cage induction motor suitable for 415 V/3 phase,50Hz,AC supply, Suitable control panel and 5 metres PVC insulated 2.5 SQ MM Copper Conductor of Kirloskar or other approved make and as directed by Engineer-in-Charge.
1
-
-
Supply and installation of Centrifugal Monoblock self priming nonclog pump (Slurry pump) of make Kirloskar (model SP1HM+) or other approved equivalent make with following specification including installation, testing and commissioning, etc., as directed by Engineer-In-Charge. Prime mover Specification:Power Rating: - 2HP (1.5kW). ; Type of Current: - AC (Alternate Current). ; Number of Phase: - Three Phase. ; Voltage: - 415V. ; Frequency: - 50Hz. ; No of Pole: - 2Poles. ; Type of Duty: - S1. ; Type of Rotor: - Squirrel Cage Induction Rotor. ; Ingress Protection: - IP55. ; Class of Insulation: - ‘F`. ; Type of mounting of motor: Horizontal, Foot Mounting. Pump Specification: Type of Liquid: - cold water with solids of size up to 8.5mm. ; Specific gravity of Liquid to Handled: - 1.1. ; Head Range: - 10 - 18 Meters. ; Discharge Range: - 5.75 (at 10m Head) to 1.5 (at 18m Head) LPS (Liters Per Second) at 2870 RPM (Revolution Per Minute). ; No of stages: - 1. ; Suction Size: 40mm. ; Delivery Size: - 40mm. ; Direction of Rotation: - counter-clockwise when viewed from suction side. ; Type of Flange: - Flanges are to be drilled as per IS 1538 Standard. ; Material of Construction: Motor Body: - Cast Iron (FG 200), ; Rotor Shaft: Stainless Steel. ; Pump Casing – Cast Iron (FG 200), ; Impeller: - Cast iron, ; Shaft Sleeve: - Stainless Steel. ; Type of Pump Seal: - Mechanical Seal.
1
-
-
Supplying and fixing of Air blower (twin lobe) of 25m3/hour capacity with 2 HP motor of 1440 RPM and 40mm NB inlet / outlet size of make Airvac or other approved equivalent make including Supply of common base frame for Blower and motor, suction filter and silencer, discharge cum interconnecting pipe, set of V.Belt and belt guards, set of drive and driven pulleys, pressure gauge, Non return valve and safety valve, etc. complete.
1
-
-
Providing Electronic weighing scales of Crown CRPS - 300K Electronic platform weighing Scale Heavy Duty of accuracy 20gm of Stainless Steel material, Pan size 600X600mm. Rugged Structure suitable for tough uses, Stainless steel, high precision loadcell, Metal body compact indicator, overload protection, 0.5 LED red display battery backup facility. maximum 120kg and minimum 500gm capacity of approved make conforming standard of weights of measures Act - 1985 of Rule made through under 1987 (GEN) rules etc., and as directed by Engineer-in-Charge.
1
-
-
Providing and fixing single burner confirming to IS 8749:2002 as directed by Engineer- in-Charge. Each burner assembly under separate "ON/OFF" control shall give within ± 8 percent of the manufacturer's specified gas consumption in l/h at STP when tested with compressed air at inlet pressure of 747 N/m² ( 7.62 gf/cm²)
4
-
-
Providing and fixing 1000 Litres capacity black colour PVC water tank including necessary fittings of make " sintex".
1
-
-
Supplying, stacking wet cow dung as directed by Engineer in charge.
10
-
-
Operation and maintenance of biogas plant with a capacity of 500kg including initial feeding with fresh cow dung, mixing with hot water an subsequent feeding with organic waste including mixing and grinding as per schedule of operation etc., all as per specification and as directed by Engineer in charge.
Note: 1) Stabilization period upto 2 months included in construction period from date of commissioning and maintenance period for another 6 months for bio gas production. 2) The Rate quoted shall be unit operation of biogas plant 6 Months for operation and maintenance. 3) The Contractor should engage one unskilled labour at 8.30 Hours per unit operation.
312
-
-
Supplying and fixing of Bio Gas ballon of size 3.0 x 3.0 x 3.0 M with PVC coated polysester yarn based flexible type prefabricated with inlet pipe along with moisture trap, outlet pipe, drain pipe and accessories and MOC of PVC coated 1100 GSM etc. complete as per the Instruction of Engineer-in-Charge.
1
-
-
Providing and applying Two coats of Polyurethane paint on steel surface and other required internal surface at all levels with Apcothane CF 675 PU 240 Nickel Grey paint of ‘Asian’ or approved equivalent brand, colour and manufacturer, to give an even shade including one under coat of suitable Epoxy/PU primer, preparation of the surfaces complete all as per specification and as directed by the Engineer-in-Charge.
130
-
-
Supply installation and testing of Maintenance free earthing system (1x10feetx5/8inch copper bonded steel rod, 22 kg Ground Enhancing Material (GEM) ) as per IS: 3043 including RCC Chamber and RCC cover slab as per Drawing No.IGC/ESD/5060/1008/1 enclosed. (Refer Sec VI, Clause No.12.12).
2
-
-
Supply, fabrication and installation of the following size of Copper Flats including excavation and refilling as per the detailed specification. (Refer Sec VI, Clause No.12.7). - 25X3 mm Copper flat
20
-
-
Supply, fabrication and installation of the following size of Copper Flats in Built in trenches on walls, poles, RCC Concrete and through embedded pipes as per the detailed specification. (Refer Sec VI, Clause No.12.7). - 25X3 mm Copper flat
10
-
-
Supply and installation of the following sizes of copper wires including excavation and refilling as per the detailed specification. (Refer Sec VI, Clause No.12.8). - 8 SWG copper wire
20
-
-
Supply and installation of the following sizes of copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8) - 8SWG copper wire
50
-
-
Supply and Installation of following sizes of Surface Mounting Plastic Boxes as per the detailed specification. (Refer Sec VI, Clause No.15.6).
-
-
-
Surface Mounting Plastic Boxes 1/2 Module
10
-
-
Surface Mounting Plastic Boxes 6 Module
4
-
-
Supply and fixing following Modular front cover plate on existing modular metal/plastic boxes etc. as required. (Refer Sec VI, Clause No.15.7). - 2 Module
3
-
-
Supply, embedment and flush mounting of following sizes of Metal Clad Socket in sheet steel enclosure with Plugs and Socket including chipping and finishing as per the detailed specification.(Refer Sec VI, Clause No.15.4). - 20 AMPS DP Metra Plug and Socket DBs with 20Amps MCB
2
-
-
Supply and open installation of following Sizes of MS boxes as per the detailed specification. (Refer Sec VI, Clause No.15.10).
-
-
-
150(W)X150(H)X80(D)mm, 1.6mm thick sheet MS Box
5
-
-
300(W)X300(H)X120(D)mm,1.8mm thick sheet MS Box
1
-
-
Supply and Embedment of following sizes of flush mounting POWDER COATED TPN/SPN DB Enclosures with Double Door and per Phase isolation DBs consisting of Phase, Neutral and Earth Bus and interconnecting wires etc. at suitable depth in brick work as per the detailed specification and as directed by the Engineer-in-charge.(Refer Sec VI, Clause No.15.2). - 6 WAY Cat No:DBTPI006DD (Vertical) or equivalent make TPN TIER Per Phase Isolation (PPI) DB
1
-
-
Supply fixing testing and commissioning of the following RCBOs on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2). - RCBO DP 40A sensitivity 30mA 4Module
3
-
-
Supply Installation testing and commissioning of the following MCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).
-
-
-
40-63Amps, FP MCB (TYPE-C)
1
-
-
6-32 Amps FP MCB (TYPE-C)
1
-
-
6-32 Amps SP MCB (Type-C)
18
-
-
6-32 Amps DP MCB (TYPE-C)
1
-
-
Supply, embedment and flush mounting following sizes of Metal one way enclosures for MCBs, RCCBs, RCBOs including chipping and finishing as per the detailed specification. .(Refer Sec VI, Clause No.15.5). - DP Cat No:607882/TP Cat No:607883/ FP Cat No:607884 Metal one way enclosure (M/s Legrand/BCH or equivalent make)
1
-
-
Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)
-
-
-
3/3.5/4core X Upto 25 sqmm
300
-
-
3/3.5/4Core X above 25 & up to 120 sqmm
80
-
-
Loading, Transportation, Unloading at site, Laying, Testing and Commissioning of one number PVC/HRPVC/XLPE insulated and PVC sheathed Stranded Aluminium/copper conductor power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)
-
-
-
3/3.5/4 Core X upto 25 Sqmm
250
-
-
3/3.5/4 Core X above 25 to 3/3.5/4 Core X up to 120 sqmm
80
-
-
End Termination of the following size Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).
-
-
-
4C x 2.5 Sq.mm including cable gland earthing
28
-
-
4C x 10 Sq.mm including cable gland earthing
4
-
-
Wiring for lights / fans /sensors/ Timer /Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, switches/ sockets, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18)
-
-
-
Wiring for Power Points with 2 Runs of 4.0 Sq.mm Copper wires for Phase, Neutral and 1 Run of 2.5 Sq.mm Copper wires for Earth from MCB Distribution Board to Single Phase Metal Clad Socket.
2
-
-
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from MCB Distribution Board to Power point through Control Switch Box including 16A modular switch, 6/16 Amps combined shuttered type Socket and 10A modular switch & 3 pin, 6A shuttered type Socket, Modular Plate.
4
-
-
Wiring for Exhaust fan point up to 3Mtr height with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from MCB Distribution Board to Power point through Control Switch Box including supply of 3 pin 6A shuttered type Socket, 2Nos. 2 Modular plate and 1 No 10A modular switch.
3
-
-
Wiring for Light/Sensor/Fan Points with 2 Runs of 1.5 Sq.mm copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm copper wire for Earth from MCB Distribution Board to Primary light/sensor/fan point through Control Switch Box including 10Amps modular switch.
2
-
-
Wiring for Light point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Switch box to Light point/Ceiling fan including 1 No 10A modular switch
3
-
-
Wiring for Light point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Light point to Light point /sensor/contactor
2
-
-
Wiring for Power Points with 4 Runs of 6.0 Sq.mm Copper wires for Phase, Neutral and 2 Runs of 2.5 Sq.mm Copper wires for Earth from MCB
1
-
-
Supply, installation, testing and commissioning of following sizes of Wall Mounting Exhaust Fans including supply of Aluminium grill bracket with Stainless Steel Bolts for mounting of Exhaust Fan & Aluminium grill bracket and 3 Core, 1.5 Sq.mm (14/0.3) PVC insulated & FRLS sheathed copper flexible cable of required length as per the detailed specification. (Refer Sec VI, Clause No.17.2). - 300 mm Dia Turbo Heavy Duty Exhaust Fan
1
-
-
Supply, installation, testing and commissioning of following sizes of Wall Mounting Fans as per the detailed specification.. (Refer Sec VI, Clause No.17.4). - 450 mm Dia Industrial wall Mounting fan
1
-
-
Supply, transportation, installation, testing and Commissioning of the following type of Surface mounted luminaires. (Refer Sec VI, Clause No.16.1). - Catalogue No : WAND K 30W 5700K 4Feet Batten or equivalent and Lamp Type LED
4
-
-
Supply, transportation, installation, testing and Commissioning of the following type of Wall (surface) mounted luminaires. (Refer Sec VI, Clause No.16.1). - Catalogue No : WT202W LED6S CW PSU S2 PC or equivalent and Lamp Type LED
4
-
-
Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11). - MS fabrication 1 coat primer & 2 coats synthetic enamel paint
100
-
-
Supply and external installation of following sizes of Heavy Duty, Hot Dip Galvanised MS ERW Conduits for Electrical & Communication System with all the required accessories like round JBs, Solid Long Bends, Check Nuts, Nipples, Couplings, Reducers, Copper Clips, Copper Conductor, GI Wire etc. as per the detailed specification. .(Refer Sec VI, Clause No.27).
-
-
-
25mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes.
40
-
-
32mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes.
15
-
-
40mm dia 2mm wall thickness Heavy Duty, Hot Dip Galvanised/ ERW Conduits with 50mm deep junction boxes.
10
-
-
Supply and installation of following sizes of Heavy Duty, Hot Dip Galvanised GI pipes with required accessories on Floor, column, beams etc including chasing and replastering as per the detailed specification.(Refer Sec VI, Clause No.28). - 80 mm NB, 4.8mm, wall thickness Heavy Duty GI pipe
3
-
-
Supply and Installation of 3.75 Area lighting poles with Hammer tone finishing (Pedestal type). (Refer Sec VI, Clause No.13.3 & 13.4). - Supply and embedment Post top Lantern pole including Cast Aluminium Junction Box with FRP cover as per the drawing No: IGC/ESD/2021/6001/1-R1. 3.75mtr 50NB GI pole with Hammer tone painting, cable entry pipe, cable termination arrangements etc. including providing of 1:4:8 mudmat and 1:3:6 foundation PCC conforming to the detailed specification 1mtr 16mmDia SS rod with SS wire (2 runs) equivalent to 8SWG and as per Drawing No. IGC/ESD/2021/6001/P2-R1.
7
-
-
Supply, Installation, Testing and Commissioning of following area lighting luminaries on Metalic poles of height from 2.5 M to 4 M as per per the detailed specification. (Refer Sec VI, Clause No.16.1). - Catalogue No : LPTO-40-CDL and Lamp Type LED
7
-
-
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).
-
-
-
4 Core X 16 Sqmm
14
-
-
3.5/4 C x 35 sq.mm
1
-
-
Supply and Installation of Cast aluminium Junction box with FRP cover. (Refer Sec VI, Clause No.13.6). - Supply and Installation of Cast aluminium Junction box for PTL as per the drawing no: IGC/ESD/2021/6001/1-R1, for street light pole as per the drawing no: IGC/ESD/2021/6001/3, and as per the detailed specification.
1
-
-
Supply, transportation, installation, testing and Commissioning of the 25 litre capacity Storage Water Heater as per the detailed Specification.
1
-
-
Supply, transportation, installation, testing and Commissioning of the 415V, Three Phase Wall mounted fabricated DB as per the detailed Specification and Single line Daigram
1
-
-
Supply, transportation, installation, testing and Commissioning of the 5HP DOL Starter Box as per the detailed Specification.
1
-
-
Supply, transportation, installation, testing and Commissioning of the 2HP DOL Starter Box as per the detailed Specification.
4
-
-
Supply, transportation, installation, testing and Commissioning of the FRP Box with motor ON & OFF Push Button .
3
-
-
Supply, embedment and flush mounting of following sizes of Metal Clad Socket in sheet steel enclosure with Plugs and Socket including chipping and finishing as per the detailed specification.(Refer Sec VI, Clause No.15.4). - 32A 3P+N+E-FP Tempra plug and socket DBs
1
-
-
Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)
10
-
-
Overall rebate (Optional)
-
-
-
INR Zero Only
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements