Indian Institute Of Technology Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Indian Institute Of Technology - IIT Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Oct 2024
Closing Date5 Nov 2024
Tender Amount₹ 70,58,000
Costs
EMD
₹ 1,41,160Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IITM_212166_1Bid Award Id
ViewTender No
15/2024-25/ELDBTender Authority
Indian Institute Of Technology ViewPurchaser Address
-Website
http://https://www.iitm.ac.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
3/4/5.0/5.5 TR
155
-
-
7.5/8.3/8.5/11 TR
48
-
-
16.5 TR
9
-
-
AMC of Kitchen Exhaust System/Toilet ventilation systems
-
-
-
Non Comprehensive Maintenance of Kitchen exhaust system at roof top of the building of various capacities.This will include routine servicing/ regular maintenance, filter cleaning, preventive mainteanance of equipments and breakdown repairs as and when occurred, ensuring that system does not remain out of service for a period not less than 4 hours in case of major breakdowns and one hour in case of minor breakdowns due to any unforeseen breakdown. The rate shall include for consumables including belts required(2 Belts per contract can be considered) for satisfactory maintanace of the installation. In case of replacement of spares required for other than belts,oiling and greese will be paid extra.
-
-
-
Kitchen Exhaust System and fresh air system
24
-
-
Toilet ventilation System
25
-
-
Toilet ventilation System-Circular/Cabinet Inline fans
233
-
-
Special Allied works
-
-
-
Charges for removing the following rating /model air conditioners from the existing position including transport and safely handed over to store.
-
-
-
Upto 2.0 TR window model Acs
100
-
-
Upto 2.0 TR split model Acs(both indoor & Outdoor unit)
500
-
-
Upto 2.5 TR Cassette type Acs(both indoor& Outdoor unit)
50
-
-
Upto 8.5 TR ductable split/Packaged Acs(both indoor& Outdoor unit)
50
-
-
Installation charges for the following rating split/ductable split/packaged and cassette type air conditioners from one position to other position including the pump down, nitrogen pressure testing, vaccumising and refilling of gas and making the machine in good working condition. (ACs will be supplied from our stores at free of cost. The contractor should arrange for transport from stores to respective locations.
-
-
-
Upto 2.0 TR window model Acs
10
-
-
Upto 2.0 TR split model Acs(both indoor & Outdoor unit)
100
-
-
Upto 2.5 TR Cassette type Acs(both indoor& Outdoor unit)
10
-
-
Upto 8.5 TR ductable split/Packaged Acs(both indoor& Outdoor unit)
16
-
-
Gas charging for 1.5TR/2.0 TR compressor including pressure holding and leak testing.
100
-
-
Gas charging/top up for ductable/packaged type ACs of following rating including pressure holding and leak testing. The gas shall be as per the machine description(like R22/R 134A/R 402A/
100
-
-
Refrigerant soft copper piping(Suction & discharge) with power chord for split ductable split and cassette type air conditioners upto 3.0 TR.
300
-
-
Refrigerant Hard drawn copper piping(Suction & discharge) for ductable split /packaged type air conditioners upto 8.5 TR.
200
-
-
Thermal insulation for copper pipes using suitable foam insulation/Nitrile rubber insulation. (Necessary scafolding/ladder to be provided by the contractor).
300
-
-
Supplying & replacement of condensing/evoporator coil with copper tube with aluminium fins in place of aluminium tube with aluminium fins of the following Acs.
-
-
-
Upto 2.0 TR window AC/Split Acs
15
-
-
Supply and fixing of following accessories while attending shifting the Acs from one location to other location/not covered under the AMC/warranty.
-
-
-
45/50 MFD capacitor
10
-
-
Reconditioning of Outdoor fan motor suitable for split Acs upto 2.0TR
6
-
-
Reconditioning Indoor fan motor suitable for split Acs upto 2.0TR
6
-
-
25 mm water line drain pipe
300
-
-
38/40 mm water line drain pipe
100
-
-
50mm dia water line drain pipe
60
-
-
75mm dia water line drain pipe
60
-
-
3 core 2.5 sq.mm copper Chord wire
100
-
-
out door fan blade
6
-
-
Mounting angle for outdoor AC unit
25
-
-
PCB serving for Acs upto 2.0 TR
20
-
-
Strainer capilliary tube
25
-
-
Fan capacitor
20
-
-
SS Glycerine filled Pressure gauges(100mm dia)
20
-
-
1.5 TR indoor unit with copper heat exchanger to match with existing unit
12
-
-
Hand held remote for split/window Acs
6
-
-
Prefilters for Fresh air fans
12
-
-
25mm /Brass Gun metal Ball valve
6
-
-
Sequential timer to control the 2 ACs alternatively
4
-
-
V-Belt-SPA-3150
4
-
-
V-Belt-SPA-3350
4
-
-
V-Belt-A26/A-29
8
-
-
V-Belt-A-60
4
-
-
V-Belt-B 112
4
-
-
Fan motor for circular/cabinet type inline fans(100-850CFM)
20
-
-
Charges for dismatling of existing GI duct work without damaging the wall/ceilig/false ceiling and other items in the location including loading,unloading safely transport the same to IIT identified location within a range of 1km.
300
-
-
Supply, installation of factory fabricated completely finished and boxed ducts (including the duct flange). All sheet shall be Class VIII – light coating of zinc, nominal 120 gsm / sqmt surface area including two sides and Lock Forming Quality prime material along with mill test certificates. TDF type flanges with rubber gaskets of thickness to match the dimensions of the ducts shall be used for connecting two ducts complete with necessary Hitech supports. The duct sealing requirement shall be of class 'B' to ensure the duct leakage shall not to exceed as per SMACNA leakage class 12. The Duct to be manufactured and tested as per SMACNA standard for Class-500 pascals.
-
-
-
Thickness 1.00 mm sheet
120
-
-
Thickness 0.80 mm sheet
120
-
-
Supply, installation, testing and balancing of air distribution system consists of factory fabricated GI sheet Flat Oval and powder coating duct with factory made fittings like bends, tees, hanging support - gripple make cable (#3 type) with crimp arrangement supports, spacing and fixing as per SMACNA standards. The rate shall be inclusive of powder coating (Mat finish) for the ducts. The colour shade shall be approved by the Institute
-
-
-
0.6mm thick GSS ducting (upto 600mm dia)
120
-
-
Supply and installation of Aluminium foil faced cross linked polyethylence insulation on SA duct & RA duct as per specifications.
-
-
-
9mm thick
120
-
-
19mm thick
60
-
-
25mm thick
60
-
-
Supply and installation of Accoustic insulation for ducting with with open cell nitrile rubber insulation material with 10mm thick & density 140-180kg/m3
150
-
-
Supply and installation of aluminium volume control dampers for SA grills/diffusers
3
-
-
Supply,installation,testing & commissioning of Powder coated extruded Aluminium Supply/Return air grille
3
-
-
Supplying, fixing testing commissioning of supply/return air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core
3
-
-
Supplying & fixing of Fresh air intake louvers bird screen type with prefilter and aluminium wire mesh (Aluminium extruded only) as per specification and sizes.
2
-
-
Supply, laying, terminating, testing and commissioning of PVC insulated, PVC sheathed steel armoured copper 1100V grade power\ control cable as required with terminations.
-
-
-
4C X 6 sqmm
200
-
-
6C X 1.5 Sqmm Copper cable for control
120
-
-
Charges for engaging skilled labour to carry out the HVAC related work//operation of AC machines in large halls/Class rooms such as AHUs/DX units as required/as instructed.(Every 4 hours will be taken as 1/2 day of work)
60
-
-
Painting with one coat on the MS pipe/MS angle and other steel structure using rubberised MRF paint as required.
100
-
-
Supplying and fixing of AI frame work of required size and dimention to suit to install outdoor/indoor units as required.
200
-
-
Excavation for cable/pipe trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
100
-
-
Excavation of the cable trenches in hard rock like roads not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
30
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements