Hindu Religious Institutions And Charitable Endowments Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Hindu Religious Institutions And Charitable Endowments - HRICE Tender
Civil And Construction
Building Construction
Eprocure
Opening Date15 Nov 2024
Closing Date3 Dec 2024
Tender Amount₹ 1,10,70,150
Costs
EMD
₹ 65,351Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HRCE_501404_1Tender No
04/2024-2025Tender Authority
Hindu Religious Institutions And Charitable Endowments ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and filling in foundation and basement with Gravel in layers of not more than 15cm thick well rammed watered and consolidated etc.,
70
-
-
Supplying and filling in foundation, basement with M Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
62
-
-
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
247
-
-
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) a)For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
466
-
-
b)For rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
335
-
-
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
345
-
-
Providing and laying in position, standardised concrete Mix M25 grade in accordance with IS 456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of work with minimum cement content of 325 Kg/m3 and maximum water cement ratio of 0.55 including admixyure (Plasticiser / super plasticiser ) in recommended proportions as per : 9103 to accelerate retard setting of concrete, improve workability without impairing strength and durability with about (5Cum) 7730kg. og 0mm machine crushed stone jelly and with about (3.3cu.m.) 5156kg. of 10-12 mm machine crushed stone jelly with about 4.79Cu.m. )7670kg. of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering and also including laying , vabricating with mechical vibrators, finishing curing etc., and providing fixtures like fan clamps in the RCC floor/ roof slab where ever necessary without claiming extra ,etc., complete.complying with standarde specification and as directed by departmental officers.The coarse and fine aggregates to be used should compling with the requirements of IS Standards. ( No separete payment will be made by the department for excess usage of materials) Foundation and basement
69
-
-
Ground Floor
80
-
-
Firtst Floor
3
-
-
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
19.2
-
-
Cement Concrete 1:3:6 (One Cement, Three CS sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three Sand and Six hard broken stone jelly). Dummy columns should be at least 1 metre height)
3
-
-
Brick work in following Cement Mortar 1:5 (One cement Five CS sand ) using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-1/4" for foundation and basement including curing, etc., complete complying with standard specifiction. Foundation and basement
74
-
-
Brick work in following Cement Mortar 1:6 (One cement six CS sand ) using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-1/4" for foundation and basement including curing, etc., complete complying with standard specifiction. Super structure in Ground Floor
98
-
-
Super structure in First Floor
20
-
-
Brick partition walls of 10.80cm thickness using best quality country bricks of size 8-3/4" x 4-1/4" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) Ground Floor
13
-
-
First Floor
48
-
-
Supplying nad fixing terra kotta jally 20x20x0.75mm including cost of materials nad labour charges cement mortat etc., complete as directed by departmental officer
4
-
-
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three CS Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
490
-
-
Plastering with Cement Mortar 1:5 (One cement and Five CS sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
1340
-
-
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
1830
-
-
Paving the floor with best quality Vertified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
230
-
-
Supply and fixing mild steel grills for windows, ventilator, gate, ladder etc including priming coat.including cost of matrerials and labour charges etc., complete as directed by departmental officer
357
-
-
Supply and fixing Rolling shutter etc including priming coat.including cost of matrerials and labour charges etc., complete as directed by departmental officer
155
-
-
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
340
-
-
Supply & fixing colour Galvalume sheet roof of .47mm thick including primeing coat fixing in position with all accessary complete complying with standard specification and as directed by departmental officers etc., complete.
31
-
-
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
22
-
-
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
286
-
-
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
30
-
-
Expansion Joint filling with Polysulphide sealant upto 20mm width - Vertical
Providing and laying with two-part lastomeric UV resistant, non-toxic gun grade liquid polysulphide sealant to fill the expansion joint, sealing joints in water retaining structure. The sealant shall have Elongation min. 500% onfirms to ASTM D 412, movement accommodation for butt joint 25% & for lap joints 50%. The sealant should meets the requirement of BS 4254 & ISO:12118. Ensure that apply a coat of polysulphide sealant primer @0.5L/m2 to get better adhesion on prepared urface before placing the sealant. The finished cost including surface preparation, filling foam backer rod, applying masking tape on both sides of the joint & polysulphide sealant filling on gap completely as per specification.
13
-
-
Supplying and Fixing of Aluminium Dye Cast Letters of approved size and colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the size Aluminium Dye Cast Letters 9’’ size the following letters Tamil "சங்கரன்கோவில் அருள்மிகு சங்கரநாராயணசுவாமி திருக்கோவில் வணிக வளாகம்" as directed by departmental officer
45
-
-
Expansion Joint filling with Polysulphide sealant upto 20mm width - Horizontal
Providing and laying with two-part elastomeric fuel resistance, UV resistant, Non-toxic once cured, resistant to flame, pouring grade liquid polysulphide sealant to fill the expansion joint, Control joints in parking area, construction joint in airport runway, Tanks, bridges & oncrete roads. The sealant shall have Elongation min. 450% confirms to ASTM D 412, movement accommodation for butt joint 25% & for lap joints 50%. The sealant should meets the requirement of BS 5212, BS 4254 & ISO:11600. Ensure that apply a coat of olysulphide sealant primer @0.5L/m2 to get
better adhesion on prepared surface before placing the sealant. The finished cost ncluding surface preparation, filling foam acker rod, applying masking tape on both sides of the joint & polysulphide sealant filling on gap completely as per specification
7
-
-
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with GI Flush mounting box ,plastic combined cover plate and 6A One way modular type (one module) switch with light / fan marking and making good of the concealed portion with suitable color for PVC light point (All switches ,cover plate and GI mounting box should be higher end company make (For light points) (Data-1)
70
-
-
Wiring with 3 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End (SD-298)
2
-
-
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with GI Flush mounting box ,plastic combined cover plate and 6A One way modular type fan marking (one module) switch with fan step regulator (2 module) making good of the concealed portion with suitable color for PVC fan point (All switches ,cover plate and GI mounting box and fan step regulator should be higher end company make (For Fan points) (Data-3)
28
-
-
Supply and fixing of 9W LED Bulb for BH point (Data - 4)
16
-
-
Supply and fixing of single box type 4'20W LED fitting with TW round blocks on wall or ceiling with with PVC unsheathed copper leads from terminals to the fitting (LED fittings should be of Higherend company make like philips/ cromption etc) (Data -5)
48
-
-
Supply and fixing of 48W LED street light fitting with LED higher end with 32mm dia GI pipe class 1 No 32mm GI bend wall with PVC unsheathed copper leads MS clamps and painting SD-448
8
-
-
Supply and fixing of 1200 mm (48") sweep A.C ceiling fan 5 star rated without regulator with 300 mm downrod on the existing clamp with connections of suitable PVC copper wire. (Fan should be of Higher end company like Cromption/orient/ Havels) (Data-7)
28
-
-
Supply and fixing of 3 nos 6 Amps 5 pin universed wall socket 2 module with module over plate plastic on suitable module concealed box GI in flush with wall inter connection (Higher end) SD-389
28
-
-
Supply and fixing of 1 no 16 Amps 3 pin socket (2 module) with 1 No 16A switch 1 way - 1 module concealed in suitable G.I. flush mounting box, plastic combined cover plate with connections complete (All accessories like G.I. boxes, corned sheet and switches should be of higher end company make) (Data - 9)
14
-
-
Supply and fixing of 40A doule pole MCB Switch in a sheet steel enclosure suitale for 2 pole MCB . Including wall cutting flushing and making good of the wall with earth connection (Data - 10)
15
-
-
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board of double door type with metal door with IP43 protection with 1 No. 32A DP MCB as incoming and 6 Nos. 6A to 32A SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISI mark (Legrand or higherend make) (SD-514)
15
-
-
Supply and run of 2 of 2.5 sqmm (36/0.3) PVC insulated single core unsheathed Copper conductor of 1100V grade in Suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1 of 2.5 sq.mm (22/0.3) PVC copper wire and making good of the concealed portion with suitable colour (SD-337)
300
-
-
Supply and run of 2 of 4 sq.mm (56 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1 of 4 sq.mm (22/0.3) PVC copper wire and making good of the concealed portion with suitable colour (SD-351)
200
-
-
Supply and run of 2 of 6 sq.mm. (84 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed on wall and ceiling with continuous earth wire connection of 1 of 6 sq.mm (22/0.3) PVC copper wire with painting of suitable colour(SD-353)
220
-
-
Supply and laying of 31/2 x 120 sq.mm PVC LTUG aluminium armoured cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good (SD-187)
60
-
-
Supply and clamping of 31/2 x 120 sq.mm PVC LTUG aluminium armoured cable in a HDPE Pipe of suitale size as per PWD Standard ( Data - 15)
30
-
-
Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with earth connection (SD 169)
2
-
-
Supply and providing cable end termination of 3-1/2 x 185 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (SD-218)
2
-
-
Supply , Farication, erection and commisioning of 200Amps dust vermin proof floor mounting cuical type metering panel oard size 11ft x 7.5ft x 1.5ft made up of 16SWG CRCA sheet steel for outer ody on suitale angle frame work 2'' x 2'' x 1/4'' with copper us of size 25mm x 6mm for 3phases and neutral on sythetic moulded compound us support with hylam sheet seperation with The following MCB switches and fuse units to e mounted in side the cuical panel oard in the seperate spaces Incoming 250Amps 4 pole MCCB (L&T or Legrand make) - 1No 300Amps porceilein fuse units-3nos Outgoing 40Amps 4 pole Isolators(L&T or Legrand make) - 15nos 32A porceilin fuse units - 15 nos (Data - 18)
1
-
-
Supply and fixing of 3 phase 300 Amps aerial fuse unit for 3nos 300 Amps fuse units (500V) on suitale MS Sheett covered with thick hylam sheet on suital angle iron work on the tapping pole with necessary clamps (Data - 16)
1
-
-
Supply and run of copper flat of size 25mm x 3mm on wall or in ground for earth connection (Panel board to ISI earthing) (Data - 17)
30
-
-
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry (SD 211)
2
-
-
GST 18 %
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%