Higher And Technical Education Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Higher And Technical Education Department - DHTE Tender
Civil And Construction
Building Construction
Eprocure
Opening Date24 Dec 2024
Closing Soon6 Jan 2025
Tender AmountRefer Documents
Costs
EMD
₹ 22,14,000Document Cost
₹ 1,575Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DHTE_17202_1Tender No
PTU/BD/65/2024-25Tender Authority
Higher And Technical Education Department ViewPurchaser Address
-Website
http://pudutenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Code No:2.27 Supplying and filling in plinth with river sand under floors, including watering ,ramming consolidating and dressing complete.
290
-
-
... More
Code No:2.27A.1 Supplying and filling with gravel (excluding rock) in trenches , plinth, sides of foundations etc . In layers not exceeding 20 cm in depth consolidating each deposited layers by ramming and watering etc .complete including all lead and lift.
1264
-
-
... More
Code No:2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
19500
-
-
... More
Code No:2.33.1 Felling trees of the girth (measured at a height of 1m above ground level) including cutting of trunks and branches , removing the roots and stacking of serviceable material and disposal of un serviceable material beyond 30cm girth upto and including 60cm girth.
150
-
-
... More
Code No:2.33.2 Felling trees of the girth (measured at a height of 1m above ground level) including cutting of trunks and branches , removing the roots and stacking of serviceable material and disposal of unserviceable material - beyond 60cm girth upto and including120cm girth.
60
-
-
... More
Code No:2.34.1 Supplying chemical emulsion in sealed containers including delivery as specified - Chlorpyriphos / lindane emulsifiable concentrate of 20%
70
-
-
... More
Code No:2.35.1.1 Diluting and injecting chemical emulsion for POST - CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) - along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall and rodding etc.complete - with chlorpyriphos / lindane E.C. 20% with 1% concentration
305
-
-
... More
Code No:2.35.2.1 Diluting and injecting chemical emulsion for POST - CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) - along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. - with chlorpyriphosl lindane E.C.20% with 1%concentration.
305
-
-
... More
Code No : 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
186
-
-
... More
Code No :4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size).
290
-
-
... More
Code No:4.12 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacture's specification.
9.3
-
-
... More
Code No:4.13 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
62
-
-
... More
Code No :5.9.1 Centering and shuttering including strutting , propping etc and removal of form for - foundations, footings, bases of columns etc for mass concrete.
1538
-
-
... More
Code No :5.9.3 Centering and shuttering including strutting , propping etc and removal of form for - Suspended floors , roofs , landings , balconies and access platform.
2592
-
-
... More
Code No :5.9.5 Centering and shuttering including sqm strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and catilevers.
2026
-
-
... More
Code No :5.9.6 Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars , Piers , Abutments , Posts and Struts.
2863
-
-
... More
Code No :5.9.7 Centering and shuttering including strutting , propping etc and removal of Reinforced Concrete Work form for - Stairs , (excluding landings) except spiral -staircases .
180
-
-
... More
Code No :5.9.13 Centering and shuttering including strutting , propping etc and removal of form for - Vertical and horizontal fins individually or forming box louvers band, facias,and eaves boards.
470
-
-
... More
Code No :5.9.19 Centering and shuttering including strutting , propping etc and removal of form for -Weather shade , Chajjas, corbels etc., including edges.
59
-
-
... More
Code . No.5.11.1 Extra for additional height in centering , shuttering where ever required width adequate bracing , propping etc. including cost of de - shuttering and ecentering at all levels , over a height of 3.5m, for every additional height of 1metre or part thereof (plan area to be measured) - Suspended floors, roofs, landing , beams and balconies (Plan area to be measured).
2592
-
-
... More
Code No :5.22.6 Steel reinforcement for R.C.C.work kg including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more.
168670
-
-
... More
Code No:5.22A.6 Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo - Mechanically Treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more.
195957
-
-
... More
Code No:5.25 Providing and fixing in position copper plate as per design for expansion joints.
612
-
-
... More
Code No:5.28 Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS : 1838 , including cost of m primer , sealing compound in expansion joints.
131
-
-
... More
Code No:5.29.2.2 Providing and fixing sheet covering over expansion joints with iron screws as per design - Aluminium fluted strips 3.15mm thick - 200 mm wide
148.2
-
-
... More
Code No:5.33.1.2 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work: using coarse aggregate and fine aggregate,Portand Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelarate / retard setting of oncrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of ntering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge.- all works upto plinth level - Concrete of M30 grade with minimum cement content of 350 kg / cum - Note: Extra cement upto 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
808
-
-
... More
Code No:5.33.1.3 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work: using coarse aggregate and fine aggregate,Portand Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelarate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge.- all works upto plinth level - Concrete of M35 grade with minimum cement content of 370 kg / cum - Note: Extra cement upto 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
96
-
-
... More
Code No:5.33.2.2 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work: using coarse aggregate and fine aggregate,Portand Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelarate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge.- all works above plinth level upto floor V level- Concrete of M30 grade with minimum cement content of 350 kg / cum - Note: Extra cement upto 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
731
-
-
... More
Code No:5.33.2.3 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work: using coarse aggregate and fine aggregate,Portand Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelarate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge.- all works above plinth level upto floor V level- Concrete of M35 grade with minimum cement content of 370 kg / cum - Note: Extra cement upto 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
496
-
-
... More
Code No :6.1.1 Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 3.5 in foundation and plinth in - cement mortar 1:4 (1 cement : 4 coarse sand).
179
-
-
... More
Code No:6.38 Provding and laying autoclaved aerated concrete (AAC) blocks masonry with 100mm /125 mm thick with grade - 1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3 ) in superstructure above plinth level upto floor five level in cement mortar 1:4 (1 cement : 4 fine aggregate) . The rate includes providing and placing in position 2 nos 6 mm dia M.S.bars at every third course of masonry work.
55
-
-
... More
Code No:6.47Providing and laying autoclaved aerated oncrete blocks masonry with 150mm to 300mm thick grade -1 AAC blocks of density 551 to 650 kg /cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-charge.(The ayment of RCC band and reinforcement shall be made for seperately)
1030
-
-
... More
Code No:8.2.2.2 Providing and fixing 18mm thick gang saw cut, mirror polished premoulded and prepolished machine cut for kitchen platforms,vanity counters,window sills,facias and similar locations , of required size, approved shade,colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels - Raj nagar plain white marble / Udaipur green marble / Zebra black marble - area of slab over 0.50 sqm
230
-
-
... More
Code No:8.3.2 Providing edge moulding to 18mm thick marble stone counters ,vanities etc., including machine polishing to edge to give high gloss finish etc. complete - Granite work
275
-
-
... More
Code No:8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 fine aggregate) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
525
-
-
... More
Code No:9.1.2V Providing wood work in frames of doors , windows, clerestory windows and other frames , wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) -Vengai wood
2.4
-
-
... More
Code No:9.5.1.1V Providing and fixing panelled or panelled and glazed shutters for doors, windows, and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately , all complete as per direction of Engineer-in-charge -(Note:- Butt hinges and necessary screws shall be paid separately) - Vengai wood - 35 mm thick shutter
184
-
-
... More
Code No:9.7.2V Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors , windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick - Kiln seasoned and chemically treated Vengai wood
92
-
-
... More
Code No:9.48.2 Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S. flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to openings / wooden frames with rawl plugs screws etc
5360
-
-
... More
Code No:9.53 Providing 40 X 5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bots, nuts and wooden plugs and embeddings in cement concrete block 300 x100 x 150 mm 1:3:6 mix (1 cement : 3 fine aggregate : 6 graded stone aggregate 20mm nominal size)
120
-
-
... More
Code No:9.70.3 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc.complete - 75 x 47 x 1.80 mm
460
-
-
... More
Code No: 9.72.1 Providing and fixing bright finished brass butt hinges with necessary screws etc complete - 125 X 85 X 5.5 mm (heavy type).
204
-
-
... More
Code No:9.74.1 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc complete - 250 x 10 mm .
64
-
-
... More
Code No:9.75.1 Providing and fixing bright finished brass door latch with necessary screws etc complete - 300 x 16 x 5 mm.
6
-
-
... More
Code No:9.81.1 Providing and fixing bright finished brass handles with screws etc complete - 125 mm.
64
-
-
... More
Code No:9.121 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness . The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S.stay shall be provided at the bottom to steady the frame
380
-
-
... More
Code No:9.122.1 Providing and fixing to existing door frames - 30mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture , made with fire - retardant grade unsaturated polyester resin , moulded to 3 mm thick FRP laminate for forming hollow rails and styles , with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings , cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856 , including fixing to frames
120
-
-
... More
Code No:9.147D.4 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50m in height dimension comprising of uPVC multi - chambered frame with in-built roller track..... window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels ) made of (bigl series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3+ or - 0.2 mm and single glazing bead / double glazinf bead of appropriate dimension.(Area of window above 1.75 sqm) - sliding window size 1.80x1.35 m
76
-
-
... More
Code No:9.147A.6 Providing and fixing factory made uPVC white colour casement /casement cum fixed glazed windows comprising of uPVC multi-chambered frame , sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 + or - 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile),.... (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm , & mullion 67 x 80 mm all having wall thickness of 2.3 + or - 0.2mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm)
27
-
-
... More
Code No:9.165.1B Providing and fixing of 65 mm Godrej Navatal lock of 7 levers with 3 keys etc complete
33
-
-
... More
Code No:9.165.2 Providing and fixing bright / matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete - 100 mm
155
-
-
... More
Code No:10.28 Providing and fixing stainless steel (grade 304) railing made of hollow tubes, channels, plates etc., including welding ,grinding. Buffing, polishing and making curvature (whereever required) and fitting the same with necessary stainless steel nuts and bolts complte. i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab withsuitable arrangement (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.,)
466
-
-
... More
Code No:11.40 Providing and laying rectified glazed ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in all colours , shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 fine aggregate) jointing with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complet
254
-
-
... More
Code No:11.41.3 Providing and laying vitrified floor tiles of size 800 x 800 mm (thickeness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make , in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) , including grouting the joints with white cement and matching pigments etc., complete - size of tile 800x800mm
2085
-
-
... More
Code No:11.55.1 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as per direction of Engineer-in-charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
1085
-
-
... More
Code No:12.15.1 Painting top of roofs with bitumen of approved quality @ 17kg per 10 sq.m impregnated with a coat of coarse sand at 60cudm per 10 sq.m including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete - with residual type petroleum bitumen of grade VG-10
1731
-
-
... More
Code No:12.20 Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound , laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete
1731
-
-
... More
Code No:12.20L Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with Parapet wall complete
174
-
-
... More
Code No:12.22 Making khurras 45x45cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm nominal size) over P.V.C. sheet 1m x1m x 400 micron , finished with 12 mm cement plaster 1:3 ( 1cement : 3 coarse sand) and a coat of neat cement , rounding the edges, making and finishing the outlet complete
32
-
-
... More
Code No:12.41.2 Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter
290
-
-
... More
Code No:12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110 mm bend
34
-
-
... More
Code No:12.42.6.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) - 110mm shoe
34
-
-
... More
Code No:12.43.2 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete - 110mm
320
-
-
... More
Code No:12.46 Providing and fixing to the inlet mouth of rain water pipe PTMT (an engineering thermoplastic ) grating square (Slit) 150mm square with a height of 8mm and weighing not less than 100 gms
34
-
-
... More
Code No:13.1.1 12mm cement plaster of mix -1:4 ( 1 cement sqm 5.47 : 4 fine sand)
5092
-
-
... More
Code No:13.2.1 15mm cement plaster on the rough side of single or half brick wall of mix - 1:4 (1cement : 4 fine sand).
2834
-
-
... More
Code No:13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand)
8400
-
-
... More
Code No:13.22 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof
1914
-
-
... More
Code No:13.46.1 Finishing walls with acrylic smooth exterior paint of required shade - New work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm.
16326
-
-
... More
Code No:13.61.1 Painting with synthetic enamel paint of approved brand and manufacutre to give an even shade - Two or more coats on new work.
62
-
-
... More
Code No:13.68.1 French spirit polishing - Two or more coats on new works including a coat of wood filler
95
-
-
... More
Code No:14.34 Providing and fixng 150mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete
26
-
-
... More
Code No:14.40.3 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc.complete - 75x65x4mm (heavy type)
81
-
-
... More
Code No:17.1.1 Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C flusing cistren, including flush pipe , manually controlled device (handle lever) conforming to IS : 7231 , with all fittings and fixtures complete , including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C.pan of size 580x440mm with integral type foot rests.
64
-
-
... More
Code No:17.2.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C.pan) with seat and lid, 10 litre low level white P.V.C. flusing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231,with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required - W.C. pan with ISI marked black solid plastic seat and lid
8
-
-
... More
Code No:17.7.4 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps ,32 mm C.P.brass waste of standard pattern , including painting of fittings and brackets ,cutting and making good the walls wherever required - white vitreous china flat back wash basin size 550x400 mm with single 15mm C.P. brass pillar tap
28
-
-
... More
Code No:17.18.1 Providing and fixing P.V.C.low level flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete - 10 litre capacity -white
116
-
-
... More
Code No:17.28.2.1 Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete - flexible pipe - 32mm dia
28
-
-
... More
Code No:17.32.2 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing - rectangular shape 453 x 357 mm
36
-
-
... More
Code No:17.78.1 Providing and fixing CP brass health faucet of approved quality - 15 mm nominal bore.
8
-
-
... More
Code No:18.9.14 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 40mm nominal outer dia pipes
58
-
-
... More
Code No:18.9.21 Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and the cost of cutting chases and making good the same including testing of joints complete (Concealed work including cutting chases and making good the walls etc.) - 20 mm nominal outer dia pipes
220
-
-
... More
Code No:18.9.35 Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings this included jointing of pipes & fittings with one step ASTM solvent cement , trenching refilling & testing of joints complete (External work) - 50 mm nominal outer dia pipes
60
-
-
... More
Code No:18.17.1A Providing and fixing gun metal gate valve with C.I.wheel of approved quality (screwed end) - 20 mm nominal bore
4
-
-
... More
Code No:18.17.3 Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 40mm nominal bore
4
-
-
... More
Code No:18.17.4 Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 50 mm nominal bore
2
-
-
... More
Code No:18.18.2 Providing and fixing ball valve (brass) of approved quality , high or low pressure , with plastic floats complete - 20mm nominal bore
2
-
-
... More
Code No:18.21.2.1 Providing and fixing unplasticised PVC connection pipe with brass unions - 45 cm length - 15mm nominal bore
100
-
-
... More
Code No:18.48AProviding and fixing rectangular high density polyethylene water storage loft tank with cover ISI: 12701 marked, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support including fittings and fixtures for tank shall be paid separately
4000
-
-
... More
Code No: 18.49.1 Providing and fixing C.P.brass bib cock of approved quality conforming to IS: 8931 - 15 mm nominal bore
72
-
-
... More
Code No:18.53.1 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931- 15 mm nominal bore
100
-
-
... More
Code No:19.7.1.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : -Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :-With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
8
-
-
... More
Code No:19.8.1.1 Extra for depth for manholes - size 90x80 cm - with common burnt clay F.P.S (non modular) bricks of class designation 7.5
8
-
-
... More
Code No:19.32.1A Making soak pit 2.5 m diameter 3 m deep with 45 x 45 cm dry brick honeycomb shaft with bricks of class designation 75 and 110mm dia UPVC pipe (type B) 1.8 m long complete as per stadard design with F.P.S.bricks
2
-
-
... More
Code No: 19.33.1 Providing and fixing on wall / column face unplasticed - PVC soil and waste pipes (type - B) conforming to IS : 13592- 1992 including jointing with seal ring conformation to IS : 5382 leaving 10mm gap for thermal expansion - single socked pipes -110mm diametre.
245
-
-
... More
Code No:19.33.1B Providing and fixing on wall face / column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 - 1999 including jointing with seal ring conforming to IS :5382 leaving 10mm gap for thermal expansion - Single tee without door - 110 x110x110mm.
70
-
-
... More
Code No:19.33.1D Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend with door 110 mm.
35
-
-
... More
Code No:19.33.2 Providing and fixing on wall / column face unplasticised - PVC soil and waste pipes (type B) conforming to IS :13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter
220
-
-
... More
Code No:19.33.2B Providing and fixing on wall / column face unplasticisd - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS :14735 -1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single tee without door - 75x75x75mm
30
-
-
... More
Code No: 19.33.2C Providing and fixing on wall / column face unplasticisd - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS :14735 -1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Bend 75 mm
35
-
-
... More
Code No:19.33.2F Providing and fixing on wall / column face unplasticisd - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS :4985 - including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Bend with door 50 mm
35
-
-
... More
NON PSR Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Sigle Y Junction with door 110 mm.
24
-
-
... More
NON PSR Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion -Elbow 110 mm.
35
-
-
... More
NON PSR Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Reducer Bush 110mm x 75mm
30
-
-
... More
NON PSR Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Reducer Bush 75mm x 50mm
30
-
-
... More
NON PSR : Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete,including cost of cutting and making good the walls and floors: inlet of 110 mm x 110mm outlet - dia
60
-
-
... More
NON PSR Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion -Elbow 75 mm.
35
-
-
... More
NON PSR Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Reducer Bush 75mm x 50mm
30
-
-
... More
Code No:21.1.2.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS:733 and IS: 1285, fixing with dash fasteners of required ....architectural drawings (Glazing, paneling and dash fasteners to be paid for separately) - for shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (fittings shall be paid for separately) - Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15)
210
-
-
... More
Code No:21.3.1 Providing and fixing glazing in aluminium door, window , ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings ( cost of aluminium snap beading shall be paid in basic item) - with float glass panes of 4.0 mm thickness
136
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%