Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Fisheries And Fishermen Welfare Department Tender

Works
Civil And Construction
Eprocure
Opening Date26 Sep 2024
Closing Date14 Oct 2024
Tender Amount₹ 9,20,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Handling, Transporting and Placing of Precast Blocks of various sizes in position as specified in the drawing and as directed including all labour for operation, tools, tackles, plants and equipments, fuel etc complete as directed by the departmental officers

1010

-

-

... More
Providing and placing insitu design mix reinforcement cement concrete of M30 (M.Thirty only) by weight basis using ordinary port land cement (OPC) 43 grade confirming to IS 8112 and as per table 5 of BIS-456-2000 with minimum cement concrete of 380 Kg/M3 (Three hundred and Eighty kilogram) and graded course aggregate using 20mm and 12mm gauge HBG stone jelly in the ratio of 70:30 (Seventy part of 20mm and thirty part of 12mm stone jelly) with maximum water cement ratio of 0.45 and using Superplasticizer 250 ml per 50Kg of cement but the rate excluding cost of steel reinforcement and form work etc. complete complying with standard specification. The rate is inclusive of cost and conveyance of all ingradient materials labour charges for weighing batching mixing laying tamping, vibrating finishing, curing and conducting sample standard cube test to ascertain compressive strength of concrete and including hire charges.

970

-

-

... More
Supplying factory fusion bonded epoxy coated with minimum 175 microns thickness H.Y.S.D. steel ( Cold, Twisted ) reinforcement for R.C.C work including cost and conveyance from point of purchase to reputed company and to site after coated straightening, cutting, bending, hooking, placing in position, lappeing and / or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design etc., complete as per specification.

1392.8

-

-

... More
Formation of Back filling of Quay wall with a layer of rubble, with Quarry stones (rough angular) weighing 1Kg to 100 Kg including quarrying, loading at quarry, grading, conveying in contractors transporting by tippers / lorries including weighing in the electronic weigh bridge for the purpose of measurement and dumping into the sea with required with necessay equipment and devices as per the drawings and specifications etc., complete in between Quay wall and Breakwaters as directed by the departmental Officers. The payment shall be made by weigh basis (i.e.,) ladden weight minus unladden weight). The contractor has to make his own arrangement for weighing the materials by weight bridge in the presence of Department Officers. (Back Filling Quay)

6500

-

-

... More
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)

-

-

-

... More
For Plain surfaces such as RCC slab, Beam, Bed Block, waist slab, landing slab, lintel etc.,

1854

-

-

... More
For column footing plinth beam staircase steps, piers raft beam raft slab etc.,

588

-

-

... More
For square or rectangular column, boxing, sunshade etc.,

783

-

-

... More
For Vertical surfaces such as sunshade boxing, vertical drops, facia for sunshade, canopy facia and other vertical walls etc.,

778

-

-

... More
Reinforced Cement Concrete 1:1½:3(One cement,one and half sand and three stone jelley) using 12mm HBG metal for wearing coat 100mm . thick with water proof compound.including cost and conveyance of all materials to site excluding centering strutting but including laying curing etc., complete.

186

-

-

... More
Formation of Embankment with gravel with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement etc., complete as per specifications which includes of cost and conveyance of gravel watering charges & campacion by vibratory roller

372

-

-

... More
Earthwork Excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth with in the compound in places shown by the departmental officers with an initial lead of 10mts and initial lift of 2mts and clearing and levelling the site etc., Complete complying with standard specifications.

1366

-

-

... More
Refilling basement with excavated earth in layers of not more than 15cm thick well rammed, watered and consolidated etc.,

725

-

-

... More
Supplying and filling in foundation, basement, etc with filling M.sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

466

-

-

... More
Cement Concrete 1:4:8 (One cement, Four sand and Eight hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers

470

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
For Foundation and Basement

472

-

-

... More
For Ground Floor up to 4.50 M height

252.5

-

-

... More
For First floor

0.6

-

-

... More
Brick work in following Cement Mortar using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.

-

-

-

... More
For Foundation and Basement

248

-

-

... More
For Ground Floor up to 4.50 M height

41

-

-

... More
In first floor

5

-

-

... More
Special ceiling plastering CM 1:3 (One cement and Three sand), 10mm thick all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.

2930

-

-

... More
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.

1705

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putt

4270

-

-

... More
Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 10-12mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.

82

-

-

... More
Paving the Top of roof with Solar refelective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works)

1015

-

-

... More
Paving the floor with Granite slab of size 1200 X 600mm and above (8 X20mm thick) in all floors in CM 1:3, 20mm thick Granite slab (Ruby Red/Raw Silk/Jet Black) 20mm thick for flooring

1120

-

-

... More
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.

60

-

-

... More
Supplying and fixing in position best approved of ISI quality of 110mm diameters of PVC RAIN WATER DOWN FALL PIPES having a working pressure of 4 kg / sq.cm

120

-

-

... More
Stoneware Gully Trap of size 150mm x 100m with CastIron Double Gratings

9

-

-

... More
Supplying and fixing of PVC Water Tank

2000

-

-

... More
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.

-

-

-

... More
upvc 20 mm dia

50

-

-

... More
upvc 25 mm dia

75

-

-

... More
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)

5

-

-

... More
Supplying, laying and jointing UPVC specials of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials

-

-

-

... More
Elbow 25 mm

12

-

-

... More
Elbow 20 mm

13

-

-

... More
Tee 25 mm

15

-

-

... More
Tee 20 mm

12

-

-

... More
Coupler 25 mm

15

-

-

... More
Wiring with 2x1.5 sqm (22/0.3) PVC insulated unsheathed SC.Cu Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.T. switch inflush with wall, covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (For electronic regulator) (5 Points per Coil) -SD 22

66

-

-

... More
Supplying and fixing of twin box type 4" 40W flu fitting complete with copper choke and condensor, with TW round block on wall or ceiling with tubes and PVC unsheathed Copper leads from terminals to the fitting.-SD-90

51

-

-

... More
Supply and laying of 4 x 6 Sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling good. SD No. 201

450

-

-

... More
Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete. SD No. 129

1

-

-

... More
Supply and fixing of 5A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch on suitable TW box connection complete. SD No. 136

30

-

-

... More
Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch on suitable TW box connection complete. SD No. 139

15

-

-

... More
PLUG AND SOCKETS IN SHEET STEEL ENCLOSURE WITHOUT MCBs (BWD SOR - Page No.132

-

-

-

... More
20A Single Pole

54

-

-

... More
20A Double Pole

42

-

-

... More
VERTICAL THREE PHASE DISTRIBUTION BOARD WITH MCBS 4 way / 8 way / 12 way vertical TPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating One No. 4 pole incoming MCB / Isolator and another separate 4 way provision for accommodating One No. 4 pole ELCB / RCD with label holder and provisions (4 ways 3 phase DB No. of ways incomer MCB / Isolator - 4 No. of ways incomer ELCB / RCD - 4 No. of outgoings ways - 12)

3

-

-

... More
Supplying and Fixing of Steel I Section At A Height Of 4.0 m ISHB250 With bottom Base plate welding Top Suitable hole for fixing roof truss etc complete as per standard specification

1344

-

-

... More
Supplying and Fixing of Roof angle truss with members of ISA Section. Bracings should adopted in ISA 65x65x6 and Tie runners and rafters ISA 70x70x6, with suitable purling, Gusset plate, cap plate, shoe angle, and bolts etc. to maintain a slope of 1 in 3 as per Standard Specification.

4480

-

-

... More
Supplying and fixing colour galvalume sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.

234

-

-

... More
Supplying and fixing of Wall mound high pressure cleaner including conveyance, labour for fixing. Complete complying with standard specification etc.

2

-

-

... More
Sub Total Amount for above all items (excluding GST)

1

-

-

... More
GST 18% for above SubTotal Amount

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.