Fisheries And Fishermen Welfare Department Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Fisheries And Fishermen Welfare Department Tender

Works
Agriculture or Forestry Works
Eprocure
Opening Date6 Feb 2024
Closing Date20 Feb 2024
Tender Amount₹ 39,50,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

1959.04

-

-

... More
Supplying and Filling the basement with Gravel earth in layers of not exceeding 15cm thick well rammed and consolidated etc.

12025

-

-

... More
Cement Concrete 1:4:8 (One Cement, Four crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification

1617

-

-

... More
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.

355

-

-

... More
Supplying and filling with 40 to 80mm aggregate including cost of materials conveyance and labour charges etc. complete .

13

-

-

... More
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)

5485

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)

-

-

-

... More
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.

2826.98

-

-

... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.

1552

-

-

... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.

2832.01

-

-

... More
Centering for curved surfaces of all RCC items of work

2065

-

-

... More
Plane Surfaces

-

-

-

... More
0 to 3.30m

110

-

-

... More
3.31 to 4.30m

32

-

-

... More
11.31 to 12.30m

140

-

-

... More
Curved Surface

-

-

-

... More
0 - 3.30m

290

-

-

... More
3.31 - 4.30m

5

-

-

... More
7.31 to 8.30m

5

-

-

... More
11.31 to 12.30m

70

-

-

... More
Square Column

-

-

-

... More
0 to 3.30m

28

-

-

... More
3.31 - 4.30m

7

-

-

... More
4.31 - 5.30 m

9

-

-

... More
5.31 - 6.30 m

9

-

-

... More
6.31 - 7.30 m

9

-

-

... More
7.31 - 8.30 m

7

-

-

... More
8.31 - 9.30 m

9

-

-

... More
9.31 - 10.30 m

9

-

-

... More
10.31 - 11.30 m

9

-

-

... More
11.31 - 12.30 m

4

-

-

... More
Circular Column

-

-

-

... More
Below G.L

2

-

-

... More
0 to 3.30m

6

-

-

... More
3.31 - 4.30m

2

-

-

... More
4.31 - 5.30 m

2

-

-

... More
5.31 - 6.30 m

2

-

-

... More
6.31 - 7.30 m

2

-

-

... More
7.31 - 8.30 m

2

-

-

... More
8.31 - 9.30 m

2

-

-

... More
9.31 - 10.30 m

1.75

-

-

... More
10.31 - 11.30 m

2

-

-

... More
11.31 - 12.30 m

1

-

-

... More
Cement Concrete 1:1-1/2:3 (One Cement, One and a half crushed stone sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers

-

-

-

... More
Foundation and Basement

2342.02

-

-

... More
For Ground floor

962.02

-

-

... More
In First Floor

9

-

-

... More
In Second Floor

3

-

-

... More
In Third Floor

8

-

-

... More
In Fourth Floor

24

-

-

... More
In Fifth Floor

13

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)

3911

-

-

... More
Brick work in following Cement Mortar 1:5 using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.

-

-

-

... More
For foundation and Basement

526.99

-

-

... More
Ground Floor

6

-

-

... More
Brick work in following Cement Mortar 1:6 using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.

-

-

-

... More
Ground Floor

539.98

-

-

... More
First floor

53

-

-

... More
Brick partition walls of 11.50cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7 cm in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)

-

-

-

... More
Ground Floor

159

-

-

... More
Vacum dewatering on freshly laid and thoroughly vibrated concrete surface to produce a homogeneous and smooth concrete surface .Suction matshall be spread over the levelled fresh concrete surface and shall be connected by the suction hose to the vaccum

2950

-

-

... More
Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two crushed stone sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)

-

-

-

... More
25mm thickness

5028

-

-

... More
Paving the floor with best quality Double charged Vertified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

932

-

-

... More
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

130

-

-

... More
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. Dadooing with printed design colour glazed tiles of size 300 x 200 x 6mm

420

-

-

... More
Paving the Top of roof with Solar refelective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works)

1302

-

-

... More
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

172

-

-

... More
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.

105

-

-

... More
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.

2045

-

-

... More
Plastering with Cement Mortar 1:5 (One cement and Five P-sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.

9972.99

-

-

... More
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P-Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers

6912.01

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

16846.99

-

-

... More
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

317

-

-

... More
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed. (c) 75mm thick slab (using 20mm HBGS Jelly)

1

-

-

... More
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work

94

-

-

... More
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work

152.2

-

-

... More
Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc.,

105

-

-

... More
Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete.

2

-

-

... More
Supplying and fixing Teakwood frame with scantling above 2m for doors including labour charges for wrought and putup in possible and for fixing holdfast in frame and necessary etc., complete.

1.75

-

-

... More
Supplying and fixing Teakwood fully panelled shutters for using Teakwood scantlings upto 4m length and teakwood 40mm thick for styles and rails and 22mm thick for planks and panels including cost of wind appliances and labour charges for fixing the furniture fittings in position but excluding cost of furniture fittings complete as directed by the Departmental officers.

37

-

-

... More
Supplying and fixing solid core particle board flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround commercial ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 150x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers.

45

-

-

... More
Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. (a) Solid panel PVC door with frame

28

-

-

... More
Fabricating Supplying and fixing in position of Aluminium anodised Powder Coated of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section Vertical & Top rail: 50x44.45x2.50mm@1.292 kg/m and Bottom rail: 100x44.45x2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m,Alu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 1 Nos., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bushincluding cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete. All the Alu. Section are to be anodised with matt finish under electricaly controlled conditions in accordance with IS 1868/1962 for an average anatic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge.

32

-

-

... More
Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition. The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 5.5mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes in RCC column,masonry wherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing as directed by the departmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineer before use.

370

-

-

... More
Supplying and fixing of M.S.grill of approved design for open courtyard, grill, grill work to doors and window openings etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.

185459

-

-

... More
Supplying and Erecting Pull and Push Type Rolling Shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc Electrically Operated Type (exceeding 12 sqm. Area)

76

-

-

... More
Supplying, fabricating, erecting and fixing Hilux (or) equivalent board false ceiling upto a ceiling height of 4.5m from floor level. (b) Using perforated sheets (10mm thick)

219

-

-

... More
Providing Cornice Work for Gyp Board False Ceiling

150

-

-

... More
Manufacturing, supplying and fixing in positon of RCC Jally of 5cm thick in cement concrete 1:2:4 using 20mm machine crushed stone jelly (excluding cost of reinforcement steel) including cost of mould, finishing, curing, lifting, fixing in position etc., complete complying with standard specification and as directed

1

-

-

... More
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).

18

-

-

... More
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings..... (h) Colour glazed European Water Closet with 12.5 litre capacity procelin flushing tank fixed with CI brackets

8

-

-

... More
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).

4

-

-

... More
Supplying and fixing of White Glazed Porcelain Oval Shape Special Type Urinal of size 382 x 398 x 601mm

7

-

-

... More
Supplying and fixing best quality and make of ready mixed HDPE water storage tanks having 1000 litres capacity made of PVC materials including necessary provision for conveying, jointing delivery lilne, scour pipe, over flow pipe et c., and lifting the tank to the top of the building placing in position etc., complete as directed by the departmentaal officers. etc complete.

10000

-

-

... More
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)

11

-

-

... More
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)

17

-

-

... More
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 100mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).

12

-

-

... More
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).

14

-

-

... More
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)

28

-

-

... More
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.

111

-

-

... More
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

122

-

-

... More
Supplying and fixing in position best quality cuddapah sink of following sizes including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Executive Engineer before use on works] (b) Cuddapha sink of 600 x 600 x 200mm

9

-

-

... More
Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The wall putty shall be got approved by the Executive Engineer before use of work).

3709.4

-

-

... More
Pre construction Antitermite treatment for the Construction of building all chemicals as per standard specification including building all chemicals as per standard specification including labour charges for preparing the area for treatment spraying chemicals and other incidental charges etc., complete. The rate quoted shall be giving antitermite treatment to the building for the following four stages including breaking the termitemounds making holes with crowbars and pouring chemicals etc., complete as per IS 6313 - 1981 and as directed by the departmental officers etc., complete including cost of chemicals labour transport storing etc., The termite chemicals should have 0.5% concentration for entire operation

4318

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete

186

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing.The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete

109

-

-

... More
Supplying and fixing colour galvalume sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.

4087

-

-

... More
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. (External Electrification)

-

-

-

... More
50mm dia

1830

-

-

... More
25mm dia

323

-

-

... More
20mm dia

224

-

-

... More
Supplying UPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements

-

-

-

... More
50mm Elbow

388

-

-

... More
50mm tee

236

-

-

... More
50mm coupler

353

-

-

... More
50mm bend

252

-

-

... More
50mm union

403

-

-

... More
25mm Elbow

76

-

-

... More
25mm tee

64

-

-

... More
25mm coupler

76

-

-

... More
25mm bend

76

-

-

... More
Reducer 25x20mm

76

-

-

... More
25mm hex nipple

140

-

-

... More
20mm Elbow

66

-

-

... More
20mm tee

66

-

-

... More
20mm coupler

66

-

-

... More
20mm bend

66

-

-

... More
20mm hex nipple

110

-

-

... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level

-

-

-

... More
75mm dia

146

-

-

... More
160mm dia

612

-

-

... More
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).

-

-

-

... More
75mm dia PVC Elbow

62

-

-

... More
75mm dia PVC Elbow with door

56

-

-

... More
75mm dia PVC Tee

52

-

-

... More
160mm dia PVC Elbow

52

-

-

... More
160mm dia PVC Elbow with door

46

-

-

... More
160mm dia PVC Tee

48

-

-

... More
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.

-

-

-

... More
50mm dia Gate valve

90

-

-

... More
25mm dia gate valve

30

-

-

... More
Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications. (The PVC cowl should be got approved by the Executive Engineer before use on works).

-

-

-

... More
For 110mm dia

1

-

-

... More
Construction of Inspection Chamber following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality fly ash bricks with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.

-

-

-

... More
0.60x0.60m size

56

-

-

... More
Drilling of 6" dia (150mm) vertical bore of hard rock areas to any required depth as directed by the departmental officers rate is inclusive of labour charges for inserting casing pipe assembling the equipment in piont as selected welding the casing pipe if necessary and also tranportation charges for the rig and supporting vehicle from one place to another etc., complete complying with standard specifications.

100

-

-

... More
Supplying suitable size casing pipe for 6" dia borewell ( 6kg/sqcm) of best quality with ISI mark with necessary PVC coupling with socket end, The PVC should got approved by the departmental officers before execution.

40

-

-

... More
Labour charges for inserting PVC casing pipe assembly (with slots or without slots) in the drilled hole including jointing the pipes with Pvc couplers.

40

-

-

... More
Supplying and fixing of suitable PVC endcap (6 Kg/cm) for 160mm dia borewell of best quality with ISI mark (The PVC endcap should be got approved by departmental officer before execution). etc., complete.

1

-

-

... More
Supplying and fixing ISI make submersible pump of 5.00 HP/ 5.00 Kw model CSM-9 with outer dia 50mm of IS 14220 specification with submersible S/D starter of 8.9 - 13.50 A rekat range with 13.5 A rating and 380-415 V AC coil voltage as per specification. Providing necessary panel board with DOL bush button starter with over load relay three phase preventer indicating lamps ON/OFF switches-1 No automanual selection switch complete as directed etc, complete.

5

-

-

... More
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and Jointing.

1

-

-

... More
Supply and laying of 2 core 1.5 sq.mm armoured copper cable for control wiring to the Terrace Pump Motor with runs of 14 SWG TC wire for earthing, providing in wall with suitable size GI clamps, screws, wooden plug, end termination by using suitable size cable glands, copper sockets and etc., as directed by the Departmental Officers. complete as directed by the departmental officers

100

-

-

... More
Supply and fixing three phase panel board with necessary DOL starter - 1 No, Indicater-1 No, 32Amps fuse unit -1 No etc.,complete.The rate is inclusive cost of panel board and all other accessories, exeise duty and taxes, VAT & conveyance charges, etc., complete.,

1

-

-

... More
Supplying, laying and jointing UPVC Pipe (Un-Plasticized Polyvinyl Chloride) UPVC used for commercial applications operate and designed to handle higher water pressure (Schedule-40) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works.

-

-

-

... More
50mm dia UPVC pipe

200

-

-

... More
Supplying of best and approved quality of Nylon rope of the following size including laying in the bore well and tying with copper wire it etc commplete complying with standard specification.

100

-

-

... More
Supplying and erecting 1H.P monoblock with ISI mark with necessary accessories (motor should be got approved by Executive Engineer before use on works) complete complying with standard specification.

1

-

-

... More
Supplying and fixinng of Pre cast RCC POST to asize of 0.15x0.15x2.10m using RCC 1:11/2:3, blue granite HBG 20mm metal includingn cost of materials and cost of mould, finishing etc., comlete including of reinforcement etc.,

400

-

-

... More
Supplying and fixing barbed GI wire complying with standard specification and as directed by the departmental officers etc., complete.

6245

-

-

... More
Construction of sub-grade and earthen shoulders with approved material Gravel /Murrum with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement complete as per specifications (including cost of earth, watering charges & compaction by vibratory roller)

220

-

-

... More
Construction of granular sub-base by providing 40mm coarse graded material, spreading in uniform layers on prepared surface, and compacting with vibratory roller to achieve the desired density, complete as per specifications. For Grading II Material

150

-

-

... More
Providing WBM For 75mm thick in Bottom layer laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per Specifications.

81

-

-

... More
Providing WBM For 75mm thick in top layer laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per Specifications.

80

-

-

... More
Providing and applying tack coat on granular surface treated with primer at 7.5kg per 10 sqm heating bitumen in boiler fitted with spray set (excluding cleaning of road surface) including of cost of all materials, labour, HOM of machineries complete as per specifications. .

1001.4

-

-

... More
Providing and laying bituminous macadam on prepared surface with crushed coarse aggregates as per design mix formula for base / binding course including of aggregates with F.E loader, hot mixing of stone sggregates and bitumen in hot mix plant 40 tonne capacity, transporting the mixed material in tipper to paver and laying mixed materials with paver finisher to the required level and grade, rolling by power roller to achieve the desired density, 75 mm compacted thickness with 3.3% bitumen but excluding cost of primer/ tack coat with lead upto 1 km including cost of materials, labour, HOM of machineries complete as per specifications.

50

-

-

... More
Providing and laying wearing coat of semi dense bituminous concrete 20 mm thick with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder at 4.5 to 5% of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor conrol to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per specification etc complete in all respects complete as per specifications. with 80/100 grade bitumen using 40-60 HMP

1000

-

-

... More
Supplying and Fixing in position of Chain Link fencing using 2" x 2" using 10 Gauge Galvanised Iron Wire (of all sizes) complete

2160

-

-

... More
Supplying and Fixing 110mm PVC 6kg/cm2 pipe as directed by the Departmental officers

96

-

-

... More
Supplying and laying interlocking hydraulic pressed cement concrete blocks 63mm thick and compacting the same using paver to the required level and slope etc. complete as directed by the Engineer

200

-

-

... More
Supplying and laying of HDPE Geomembrane 750 microns thickness of smooth surfaces on both sides/ only one face textured. The width of geomembrane roll shall not be less than 4.5m at easily accessible location including top and bottom width all leads and lifts manpower and machinery, material labours etc, complete and as directed by Engineer-in-charge as per MORTH.

44011

-

-

... More
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / fan point (for electronic regulator) (SD 16)

285

-

-

... More
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box inflush with wall with 5A FT switch covered with hylum sheet of 3mm thick with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / fan point (for electronic regulator) (SD 19)

1113

-

-

... More
Wiring with 3 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylem sheet covered TW switch box and 5A FT switch (two way) with continuous earth wire connection by 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed staircase light point (SD 31)

18

-

-

... More
Supply and fixing of 4'40W single industrial type fluorescent fitting complete with copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from the terminals to the fitting with fluorescent Tube (SD 92)

283

-

-

... More
Supply and fixing of 4'40W twin industrial type fluorescent fitting cornplete copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from the terminals to the fitting with fluorescent Tubes (SD 93)

420

-

-

... More
Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp (SD 110)

105

-

-

... More
Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp (SD 107)

54

-

-

... More
48W LED Street light fitting - SD-535

122

-

-

... More
Supply and fixing of WT bulk head fitting with guard suitable for 11W CFL lamp with CFL (SD 83)

31

-

-

... More
Supply and fixing of 300mm (12") sweep (High duty) AC exhaust fan complete with necessary wall opening and making good of the wall (SD 114)

196

-

-

... More
Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) (SD 140)

176

-

-

... More
Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch concealed in suitable MS box flush with wall with painting (SD 137)

315

-

-

... More
Supply and fixing of 3 Nos. 5A (3 pin and 2 pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) (SD 139)

293

-

-

... More
Supply and fixing of horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door (metal) with 40A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make) (SD 179)

20

-

-

... More
Supply and fixing of horizontal type 8 way triple pole neutral MCB distribution board in sheet steel enclosure double door (metal) with 63A 4 pole MCB isolater as incoming and 24 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make) (SD 167)

39

-

-

... More
Supply and fixing of 8 way SP DB of 16A / way with 32A DP switch with metal clad of 500V with fuse and neutral (side handle) on suitable angle iron frame work with trunking box with earth connection only (SD 160)

23

-

-

... More
Supply and fixing of 12 way SP DB of 40A / way with 32A DP MCB as incomer and 10 nos SP MCB 6A-32A as outgoing including all labour charges with suitable angle iron frame work with trunking box with earth connection only

14

-

-

... More
6 metre length single bracket pole with base plate (250x250x6mm) 76.10mm OD x 3.65mm thick x 6000mm length

60

-

-

... More
6 metre length Double bracket pole with base plate (250x250x6mm) 76.10mm OD x 3.65mm thick x 6000mm length

20

-

-

... More
Supply and erection of 2 pole 11 KV H.T structure of 33 feet RS Joist pole with 10 feet centre to centre on either side with MS angle cross bracing and mass concreting of poles to a depth of 6' and with masonry pedestal to a height of 2 feet and providing HT Strain disc insulator and O SWG size copper conductor from supply authority 2 pole structure to consumer pole with painting of all metal parts complete with supply and erection of the following HT accessories as per IE and CEIG rules and regulations: 1) 2 Nos. of 33 feet length RS Joist pole with pole caps and base plate 450x450x6mm with RCC with concrete foundation. 2) 1 set of 3 Nos. 11 KV strain disc insulators with metal parts on suitable top channel made out of 4" x 2" x 1/2" iron channel to receive E.B supply and to feed HT supply to 6 Pole structure and suitable clamps. 3) 3 sets of gang operated 11 KV horizontally / vertically operated pin insulator type AB switch complete with guide operating handle at 1.1 to 1.2m above ground level with lock on suitable double channel and angle iron cross arm with channel size 4" x 2" x 1/4" complete with suitable clamps. 4) one sets of ( 3 Nos per set) 11 KV lightning arrestors mounted an suitable channel iron of size 4" x 2" x 1/4" complete with suitable clamps . 5) One sets of (3 Nos per set) 11 KV drop out fuses with operating rod on suitable double channel and angle iron of size 2" x 1/4" complete with cross arm channel and suitable clamps with clearance of 2m from the live part of AB switch to the channel. 6) 2 sets of (3 Nos per set) 11 KV pin insulator etc. fixed on suitable channel iron frame work for supporting to the copper jumper. 7) Supply and fixing of required cross bracings made of suitable M.S Angles of size not less than 2 1/2" x 2 1/2" x 1/4" and other supports to keep the strucuture in balance. 8) Providing necessary HT connections and jumper connections from the E.B, H.T Structure to consumer 2 pole HT Structure, Zero SWG HD Bare copper conductor for giving necessary connection and jumper connection from 11 KV strain disc insulator to HT AB Switch ,AB Switch to lightning a arrester, lightning arrester to D.O fuses through pin insulator complete with colour coding. 9) Supply and fixing of 11 KV Metal Danger Board with letters and figures and conventional skull and bones in signal red in white background - 2 Nos 10)Painting the complete strcuture with a primary coat of red oxide and then by two coats of approved aluminium paint. 11) 2 Nos of stranded stay wire arrangements with guy shackle insulators at not less than 10' from ground stay rod protected at ground level by concreting

1

-

-

... More
Supply, erection, testing and commissioning of 1000 KVA, 11KV, 433V, HV - Delta, LV Star off load tap changing, copper wound, outdoor type, distribution transformer ON AN cooled, confirming to relevant IS 1180 / IEC 60076, Class A Insulation and mounted on 300 x 90 x 6mm base channel bolted to a suitable RCC plinth of height 5' and RCC foundation to a depth of 2' with reinforcement by suitable MS rods 150Kg / m3 capable of bearing 2 ton weight and connected works fitted with the following: 1) LT Cable end box suitable for connection of 3 run of 3 1/2 x 400 sq.mm LTUG cables. 2) Bucholtz relay with shut off valve, alarm and trip contacts. 3) Dehydrating silicagel breather. 4) Conservator with oil filling pipe, cap and drain plug valve. 5) Tank drain cum bottom filter valve with plug. 6) 4 Nos. plain rollers uni and bi-directional under base channels with skid. 7) Dial type thermometer with pocket to measure oil tempterature stem type. 8) Tank top filter valve with plug. 9) Explosion vent with diaphragm. 10) Oil level gauge with marking. 11) Two body earthing terminal and additional neutral bushings for solid earthing. 12 Rating and terminal marking diagram plate. 13) Lifting hooks/ Lifting eyes/ Jacking pad to facilitate easy movement of Transformer to ground level, cover lifting lugs. 14) Off load hand operated tap changing switch at standby height from ground level. 15) Tapping on primary winding for voltage variation +5% to -5% in steps of 2.5%. 16) Welded and detachable radiators. 17) Air release device. 18) The transformer should be supplied with first filling of oil as per IS 335 with high dielectric strength, BDV and flash point. 19) Monogram plate. 20) Shut off valve for surge relay 21) Oil surge relay 22) All removable covers shall be provided with weather proof hot oil resistant, resistance gaskets to prevent leakage of water into core, and oil from the tank with low no load loss and full load loss impendance with temperature rise oil /winding as per IS 1180 (Level 1) (Make: Kirloskar electric company / Indotech / CREL or Rowson ).

1

-

-

... More
Supply and fixing of Three Phases 8 way Vertical type MCCB DB with IP 42 protection Doubledoor type DB (legrand) with 1 No 160A 4P MCCB 16 KA as incoming and 8 Nos 32A TPMCB as outgoing with cable entry boxes on suitable angle iron frame work with earth connection only .(The MCCB DB ,and MCCB's and MCB's should be Like legrand/Hagger make)

2

-

-

... More
Supply and fixing earth leakage circuit breaker 63A(ELCB) to the existing seven segment MCB DB with inter connection and earth connection only.

23

-

-

... More
Supply and laying of 3 1/2 X 50 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with the bricks and sand refilling the earth to make good.

125

-

-

... More
Supply and clamping of run of 31/2 x 50sq mm PVC LTUG armourded LTUG Cable on wall with MS clamps.

80

-

-

... More
Supply and fixing of cable gland for 31/2 x 50sq mm PVC LTUG armourded Cable on wall with earth connection

4

-

-

... More
Supply and Providing cable end Termination of 31/2 x 50 Sqmm PVC LTUG aluminium armoured cable with necessary alluminium cable sockets by crimping etc. with electrical connection complete.

4

-

-

... More
Supply and clamping of run of 31/2 x 120sq mm PVC LTUG armourded LTUG Cable on wall with MS clamps.

50

-

-

... More
Supply and fixing of cable gland for 31/2 x 120sq mm PVC LTUG armourded Cable on wall with earth connection

4

-

-

... More
Supply and Providing cable end Termination of 31/2 x 120 Sqmm PVC LTUG aluminium armoured cable with necessary alluminium cable sockets by crimping etc. with electrical connection complete.

4

-

-

... More
Supply and laying of 3 runs of 3 ½ x 240 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.

21

-

-

... More
Supply and clamping of 3 runs of 3 ½ x 240 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.

10

-

-

... More
Supply and fixing of brass cable gland for 3½ x 240 sqmm PVC armoured LTUG cable with earth connection

6

-

-

... More
Supply and providing cable end termination of 3 1/2 x 240 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete

6

-

-

... More
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry

15

-

-

... More
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.

125

-

-

... More
Supply and run of 2 run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.

117

-

-

... More
Preparation of 10 copies of Electrical drawings for physical and schematic layout for HT and MV installations preparation submission of completion report to CEIG , paying all the documentation charges to CEIG arranginging inspection andavailing safety certificate CEIG for the new HT MV installation and rectification report and arranging CEIG Inspection and obtaining safety certificate from CEIG, preparation of 1set of approved drawing and a copy of safety certificate in a neat frame work to be fixed in Generator room and payment of CEIG documentation charges and Lift License: Preparation of drawing , payment of charges to CEIG and insurance policy if any and obtaining CEIG safety certificate and lift license as per lift act should be done by the lift contractor.

1

-

-

... More
Supply and erection of following Safety items: 1. 2 m x 1 m x 20 mm thick 11KV grade rubber mat-8 Nos 2.9 litre fire bucket 4 Nos with Stand - 1Set 3.5 Kg Capacity dry powder type fire extingusiher - 4 Nos 4. Rubber Hand glove 11KV - Set 5.First aid box with medicine -1Set 6 Earth discharge rod with 20 mt. long 7/20 sheathed cu.wire -1No 7.Dropout fuse operating rod -1 No 8. Megger 500V - 1No 9.Clamp meter 0-1000A - 1No

1

-

-

... More
Supply and fixing of HT /LT cable route inducator with suitable angle not less than 38mm x 38mm x6 mm and 0.6 mtr long excavation of earth to a depth of 0.6 mtr and concreting and ground level and making good of the ground as directed by the departmental officers.

25

-

-

... More
Supply & Installation of Air-Conditioner with copper coil

-

-

-

... More
2.0 TR Split type AC unit

40

-

-

... More
Supply and Installation of 4KVA capacity Automatic Voltage stabilizer with time delay relay

40

-

-

... More
Supply and Installation of 5KVA capacity Automatic Voltage stabilizer with time delay relay

40

-

-

... More
Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit)

40

-

-

... More
Supply and Fixing of MS Stand for fixing outdoor unit.

40

-

-

... More
Supply and run of 2 of 2.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 14 SWG TC wire with painting of suitable colour

13010

-

-

... More
Supply and run of 2 of 4.00 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 14 SWG TC wire with painting of suitable colour

7460

-

-

... More
Supply and run of 2 of 6.00 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 14 SWG TC wire with painting of suitable colour

3921

-

-

... More
Supply and fixing of 3 phase 4 way vertical type MCCB DB with IP 42 protection double door type DB (Legrand) with 1 No. 100A FP MCCB 16 KA as incoming and 4 Nos 63A TP MCB 10 KA outgoing with 2 nos.cable entry boxes with suitable angle iron frame work with earth connection only. (The MCCB DB and MCCBs and MCBs like (Legrand (MDS)/Hager (L&T) make)

11

-

-

... More
Supply and fixing of 3 phase 4 way vertical type MCB DB with IP 42 protection double door type DB (Legrand) with 1 No. 63A FP MCB 10 KA as incoming and 3 Nos 32A TP MCB 10 KA & 3 Nos. 32A SP MCB 10 KA outgoing in flush with wall andmaking good of the concealed portion with earth connection only. (The MCCB DB and MCBs like (Legrand (MDS)/Hager (L&T)make) (DATA -25)

11

-

-

... More
Supply and Fixing of 36W 2x2 LED square type recessed fitting (Philips/Havells/Eq) on wall of ceiling with PVC unsheathed copper leads

54

-

-

... More
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan

196

-

-

... More
Supply and run of 25mm x 6mm copper flat with necessary clamps / supports on wall / floor / ground for earth connection

450

-

-

... More
Supply and run of 1 of 14 SWG TC wire for earth connection

9000

-

-

... More
Supply and Laying of 240 sq.mm. 3 core HT XLPE 11KV (UE)

30

-

-

... More
240 sq.mm. 3 core HT Cable Indoor Terminations XLPE 11KV (E) - EPKT 3121

4

-

-

... More
AC Chargeable Emergency Lamp 2 x 11W PL Lamp with all connected accessories

1

-

-

... More
2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS

4

-

-

... More
First Aid Box complete with all First Aid Medicines

1

-

-

... More
Shock Treatment Chart fixed in glass frame

1

-

-

... More
4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle

1

-

-

... More
Hand Gloves 11KV Grade

1

-

-

... More
Danger Board as required by the Electrical Authorities

2

-

-

... More
Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms

1

-

-

... More
Earth Discharge Rod

1

-

-

... More
250A Capacitor panel (Power Factor)

1

-

-

... More
800 A MV panel

1

-

-

... More
31/2 x 400 sq.mm cable (SD 214)

750

-

-

... More
3-1/2 x 240 sq.mm cable (SD 212)

750

-

-

... More
3-1/2 x 120 sq.mm cable (SD 209)

700

-

-

... More
Supply and fixing of 16A DP switch with metal clad of 500V with fuse and neutral (side handle) on suitable TW box PWD earthing (SD 141)

40

-

-

... More
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry (SD 233)

40

-

-

... More
2 x 10 sq.mm LTUG cable (SD 198)

800

-

-

... More
4 x 16 sq.mm LTUG cable (SD 203)

1200

-

-

... More
3-1/2 x 25 sq.mm LTUG cable (SD 204)

1000

-

-

... More
SLICE B (Spoke Level Infrastructure 2)

-

-

-

... More
Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.

6021

-

-

... More
Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

135

-

-

... More
Supplying and filling gravel in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with

1155

-

-

... More
Cement Concrete 1:4:8 (One Cement, Four crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification

2100

-

-

... More
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.

303

-

-

... More
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)

8124

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)

-

-

-

... More
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.

657

-

-

... More
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.

1377

-

-

... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.

2430

-

-

... More
Cement Concrete 1:1-1/2:3 (One Cement, One and a half crushed stone sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers

-

-

-

... More
For Foundation & Basement

2525.89

-

-

... More
Ground floor

213

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)

2480.09

-

-

... More
Brick work in following Cement Mortar 1:5 using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.

-

-

-

... More
For Foundation & Basement

300.3

-

-

... More
Brick work in following Cement Mortar 1:6 using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.

-

-

-

... More
In Ground floor

228

-

-

... More
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.

240

-

-

... More
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P-Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers

4464

-

-

... More
Plastering with Cement Mortar 1:5 (One cement and Five P-sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.

2096.61

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

6576.96

-

-

... More
Fabricating and supplying and erecting the required number of trusses with structural steel members like angle iron MS plates for all truss members including cleats to receive the purlines all cutting drilling holes welding and fixing of members with necessaryThe welding should be done with submerged arc welding to full length. The rate inclusive of the cost of painting the memebers with one coat of primer of Zinc chromite and enamel paint etc., complete

109800

-

-

... More
Supplying and fixing colour galvalume sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.

3030

-

-

... More
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / fan point (for electronic regulator)-SD1

240

-

-

... More
Supply and fixing of 4'40W single industrial type fluorescent fitting complete with copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from the terminals to the fitting with fluorescent Tube -SD 89

240

-

-

... More
Supply and fixing of 3 Nos. 5A (3 pin and 2 pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) SD-139

90

-

-

... More
Supply and fixing of horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door (metal) with 40A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make) SD-179

30

-

-

... More
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry - SD -233

30

-

-

... More
Supplying and Erecting Bamboo Large (10cm dia and above) including fixing with nails and tying with ropes including labour and material charges (Frame For Temporary Drying Platform) etc complying with standard specifications and as directed by departmental officers

24300

-

-

... More
Supplying and Erecting Bamboo Large Bamboo (7.5cm-10cm dia) including fixing with nails and tying with ropes including labour and material charges (Frame For Temporary Drying Platform) etc complying with standard specifications and as directed by departmental officers

96098.4

-

-

... More
Supplying and attaching PVC coated mesh beneath the raft for entire area of the wooden drying platfrom (10m x 2m) each etc and as directed by departmental officers.

18630

-

-

... More
Sub Total Amount for above all items (excluding GST)

1

-

-

... More
GST 18% for above SubTotal Amount

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.