Fisheries And Fishermen Welfare Department Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Fisheries And Fishermen Welfare Department Tender
Civil And Construction
Excavation
Eprocure
Opening Date5 May 2023
Closing Date30 May 2023
Tender Amount₹ 6,47,50,000
Costs
EMD
₹ 3,33,750Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_AHDF_311192_1Bid Award Id
ViewTender No
03- 02 /DB/F.114 N/2023Tender Authority
Fisheries And Fishermen Welfare Department ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Earthwork Excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth with in the compound in places shown by the departmental officers with an initial lead of 10mts and initial lift of 2mts and clearing and levelling the site etc., Complete complying with standard specifications.
1332
-
-
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
510
-
-
Supplying and filling in foundation, basement, etc with filling M.sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
349
-
-
Cement concrete of mix 1:4:8 ( One cement four sand and eight aggregate) using 40 mm gauge HBG Jelly for foundation and flooring including cost and conveyance of all material and labour charges for laying land in layer of not more than 15 cm thick well rammed and curing etc., complete as per standard specifications
547
-
-
Supplying and erecting steel centering including necessary supports for plane surfaces, for all RCC works including strutting upto 3.29m in all floors using mild steel shutters of size 90cmx60cm of BG 10 stiffened with mild steel angles of size 25mmx 25mmx3mm laid over silver oak (Country wood) Joists of size 10cmx6.5cm spaced at about 90cm c/c and supported by casurina props of 10cm to 13cm dia. (spaced at 75cm c/c) etc., complete complying with standard specification and as directed by the departmental officers. (The centering will be removed after specified period of concrete without damaging the concrete)
-
-
-
Without strutting
990
-
-
Centering for beams and Slabs
500
-
-
Centering for Columns
521
-
-
For Vertical surfaces such as sunshade boxing, vertical drops, facia for sunshade, canopy facia and other vertical walls etc.,
1425
-
-
Supplying and erecting centering for water basin area using I Girder of size 250x125mm over MS flat of size 100x12mm to support on pile area and I Girder of section 150x80mm supported on cross directions and spreading of MS sheet of thickness 12 mm for Pile muff including cost of all materials and labour charges for fabrication, welding charges etc complete as per standard specifications
215
-
-
Providing and placing insitu design mix reinforced cement concrete of M35 (RMC) by weight basis using ordinary port land cement (OPC) 43 grade of as per ISI code and graded aggregate using 20mm gauge and below HBG stone jelly with maximum water cement ratio of 0.40 and using Super plasticizer but the rate excluding cost of the steel reinforcement and form work etc. complete complying with standard specification. The rate is inclusive of cost and conveyance of all ingredient materials, labour charges for weighing batching mixing laying tamping, neat finishing with suitable cement mortar if necessary and casting concrete sample standard cube and conducting test to ascertain their compressive strength, including hire charges of all machineries etc complete using Tremmie method as directed by the Engineer - For Deck slab
785
-
-
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
-
-
-
For Foundation and Basement
624
-
-
For Ground Floor upto 4.50m height
176
-
-
For First Floor
9
-
-
Reinforcement cement concrete 1:3:6 (One cement, three sand and six aggregates) using 20mm size HBG stone jelly excluding centering shuttering and also cost of reinforcement - grill --- including casting, vibrating, curing etc., complete
60
-
-
Supplying, fabricating and placing in position Corrosion Resistance Mild Steel/ ribbed Tor steel for all RCC works including binding wire, cutting, bending, tying etc.,. The rate is inclusive of coat of binding wires etc., and conveyance of steel from plant to site of work
932
-
-
Supplying fabricating and welding at random parts and placing of corrosion resistant steel reinforced bars for diaphragm wall inclusive of welding lowering the mesh etc complete
94
-
-
Brick work in following Cement Mortar using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.
-
-
-
For Foundation and Basement
145
-
-
For Ground Floor upto 4.50M height
100
-
-
Brick partition walls of 11.50cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7 cm in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
60
-
-
Special Plastering with cement mortar 1:3 (One cement and three P.sand) 10mm thick in all floors using fine river sand and water proofing compound of approved quality at 2% by weight of cement used including finishing and curing etc., complete complying with standard specification and as directed by the department officers
2132
-
-
Plastering with cement mortar 1:5 - 12mm thick in all floors using fine river sand including neat finishing, curing, etc., complete complying with standard specification and as directed by the department officers.
1794.99
-
-
Painting two coats of newly plastered wall surface with ready mixed Plastic emulsion paint of first class quality and of approved colour over a priming coat including preparing the surface clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on work).
3489.99
-
-
Weathering course using best quality of broken brick jelly of 20mm gauge in pure slacked lime (no sand to be added) the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer and consolidated to the required finished thickness and slope by beating the concrete with wooden beater of approved pattern and keeping the surface constantly wet by sprinkling lime jaggery water etc., complete complying with standard specification and as directed by the departmental officers.
60
-
-
Finishing the top of roof with one course of pressed tiles of size 23×23×2cm of approved quality laid in cement mortar 1:3 (One cement and three sand) 12mm thick mixed with water proofing compound (confirming to Indian standard specification) 2% by weight of cement used and pointed with the same mortar including mixing of red oxide etc., complete complying with standard specification and as directed by thedepartmental officers.
720
-
-
Paving the floor with pre polished granite slab (Ruby Red/Raw Silk) of thickness 18mm to 20mm of best quality and approved variety and size not less than 1200x600mm confirming to ISI specification, in cement mortar 1:1 (One cement and one P.sand) 20mm thick and pointed with same coloured cement neatly etc., complete complying with standard specification.
715
-
-
Rough Plastering the surface of walls with Cement Mortar 1:4 (One cement and Three sand), 20mm thick in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
100
-
-
Flooring with ceramic tiles (colour and shade as directed) of size 305x305x6mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand) 20mm thick laid in-situ and pointed with same coloured cement (white cement mixed with colouring pigment) neatly and fixed in position so as to make it perfectly smooth and shining to the alignment etc., complete as per standard specifications
62
-
-
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / Sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
355
-
-
Supplying and fixing in position best approved of ISI quality PVC rain water down fall pipes of 110mm dia having a working pressure of 4 kg / sq.cm including cost of necessary PVC shoe, PVC bend, C.I. gratings of required dia. and special clamps, brass screws, nails etc., and fixing of cast iron gratings at juction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cost of removable iron grating. The PVC pipe shall be fixed on wall with special type of clamps. Special type "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0M pipe length complying with standard specification. ( Above Ground Level)
96
-
-
supplying and fixing in position Glazed steel ventilator with Side/Central hung shutters (Three Leaves) frames and made shutter frame made out of steel section conforming to IS 7452 /1990.The outer frame made out of z section (F7D) of size 33 x22 x3 mm conforming to IS 7452/1990.The mullions are made out of (F4B) section of size 46x25x3 mm and conforming to IS7452/1990.The shutters are individual and each of them can be operated separately.Sash bars are made of T section (T2) of size 25 x 22 x 3mm 2 nos of sturdy hinges and one number of handle cum latch of special type are fixed are each openable shutter with suitable opening in left for its easy operation, one member of adjustable strings with fixing brackets of sufficient length are provided for each shutter 4 nos of 40 x 40 x 3 mm angle hold fast 230mm length are welded with the frame at appropriate point M.S Square bars of 12 mm dia is welded to the inner face of the ventilator at equal intervals not exceeding 10 cm spacing 3mm pin headed glass is used for Glazing with good quality anf fixed with 15 x 12 mm teak wood beadings with screws for fixing .The shutters are to open outside.All the section are given with one coat of red oxide primer etc. complete complying with standard specification
3
-
-
Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutters using 5mm thick PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mmx30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mmx30mm. The over all size of frames shall be 50mmx45mm with suitable rebate for housing the shutter.
18
-
-
Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x6mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete.
16.8
-
-
Supplying and fixing of aluminium welded mesh required size etc., complete with complying with standard specifications as directed by the departmental officers.
80
-
-
Supplying and fixing grills to doors, windows and ventilators etc. using necessary MS flats (or) square rods for inner members and outer members which should be fixed to window frames as directed and design given by the departmental officers inclusive of cost of providing one coat of best quality red oxide primer etc., complete complying with standard specification and as directed by the departmental officers .
10
-
-
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
10
-
-
Supplying and fixing in position 150 x 100mm "P" or "S" stoneware gully trap 'A' grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works.
245
-
-
Supplying and fixing PVC Nahini trap with PVC gratings. Fixed over a bed of brickjelly; lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
10
-
-
Supplying and fixing in position white glazed European water closet with PVC low level flushing tank of best quality and approved make with 100 mm P or S trap with double flapped rigid PVC cover with C.P brass hinges, 15mm dia brass nipple - 2 Nos, 15mm dia PVC brass connection, 15mm dia wheel valve, 16mm dia nylon connection and giving necessary water supply connection etc., as per standard specifications
2
-
-
Supplying and fixing in position Indian water closet oriya type of size 580x440mm white glazed earthernware of approved quality with 'P" trap or 'S' trap conforming to IS 2556-Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to PVC. pipes by dismantling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specification and as directed by the departmental officers.(The Oriya type Water Closet and all accessories should be got approved by the departmental officers before use on work)
6
-
-
Supplying and fixing in position best quality approved make Lipped mouth flat back Urinal of size 550x400mm with a pair of cast iron brackets including cost of 15mm dia chromium plated pillar tap, 32m dia C.P waste pipe, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm dia brass nipple, 15mm nylon connection etc., including fixing the wash hand basin in the wall in position with a pair of CI brackets with teak wood plugs and screws and giving necessary water supply connection and painting the brackets with two coats of paint over a priming coat of anticorrosive paint including testing for leakage etc., complete as per standard specifications
4
-
-
White marble slab (Adanga) for Urinal partition (4'x2') including cost of fixing nosing the edges, polishing clamps, bolt and nuts etc complete
3
-
-
Supplying and fixing best approved quality Brass Chromium Plated Towel Rail 600 mm Long and 20mm Diametre with brackets of same materials including cost teakwood plug and CP Screws etc.,complete complying with standard specifications.
8
-
-
Supplying and Fixing of PVC ready made water tank of approved quality with standard specification and best brand including testing for leakages after making installations and connections. The cost inclusive of lid and lock with bolt and nuts for PVC tank, transportation, loading, unloading ,lifting, installation and necessary connections etc., complete complying with standard specifications and as directed by the departmental officers.(The PVC Water Tank should be got approved by the Executive Engineer before use on works).
4000
-
-
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.
-
-
-
upvc 20 mm dia
100
-
-
upvc 25 mm dia
175
-
-
upvc 32 mm dia
250
-
-
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
20
-
-
Supplying and fixing in position by pasting new UPVC specials like Finolex or equivalent such as plain bend, door bend, plain tee, door tee off sets, 'Y' junction plain or with door of various sizes of best approved quality conforming to ISS.and providing leak proof joints including fixing to walls and giving connection to the UPVC soil stacks,dismantling the brick masonry/RCC.floor or roof slab and redoing the disturbed portion to original condition etc., complete complying with standard specification as directed by the Departmental Officers.
-
-
-
Elbow 32 mm
31
-
-
Elbow 25 mm
30
-
-
Elbow 20 mm
35
-
-
Tee 32 mm
50
-
-
Tee 25 mm
41
-
-
Tee 20 mm
24
-
-
Union 32 mm
35
-
-
Coupler 32 mm
20
-
-
Coupler 25 mm
25
-
-
Wiring with 2x1.5 sqm (22/0.3) PVC insulated unsheathed SC.Cu Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.T. switch inflush with wall, covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (For electronic regulator) (5 Points per Coil)
84
-
-
Supplying and fixing of twin box type 4" 40W flu fitting complete with copper choke and condensor, with TW round block on wall or ceiling with tubes and PVC unsheathed Copper leads from terminals to the fitting.
54
-
-
Supply and fixing of 1200 mm (48") sweep AC ceiling fan complete with stepped electronic 300W regulator, with 1 metre down rod with fan clamp with side plates and cross arm of size 450 mm (18")
24
-
-
Supply and laying of 4 x 6 Sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling good.
450
-
-
Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete.
1
-
-
Supply and fixing of 5A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch on suitable TW box connection complete.
20
-
-
Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch on suitable TW box connection complete.
10
-
-
PLUG AND SOCKETS IN SHEET STEEL ENCLOSURE WITHOUT MCBs
-
-
-
20A Single Pole
36
-
-
20A Double Pole
28
-
-
VERTICAL THREE PHASE DISTRIBUTION BOARD WITH MCBS 4 way / 8 way / 12 way vertical TPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating One No. 4 pole incoming MCB / Isolator and another separate 4 way provision for accommodating One No. 4 pole ELCB / RCD with label holder and provisions (4 ways 3 phase DB No. of ways incomer MCB / Isolator - 4 No. of ways incomer ELCB / RCD - 4 No. of outgoings ways - 12)
2
-
-
Supplying and Fixing of Steel I Section At A Height Of 4.0 m ISHB250 With bottom Base plate welding Top Suitable hole for fixing roof truss etc complete as per standard specification
1344
-
-
Supplying and fixing colour galvalume sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.
234
-
-
Supplying and fixing of Wall mound high pressure cleaner including conveyance, labour for fixing. Complete complying with standard specification etc.
2
-
-
Supplying and Filling graded HBG Stone jelly of size 63 to 40mm including compaction etc complete as directed by departmental Officers
120
-
-
Providing weep holes using PVC pipes of 75mm dia 6kg/sq.cm, including cost of pipe and fixing in diaphragm wall at appr0oriate height etc complete
50
-
-
Supplying and Fixing in position pipe bollard of 300mm dia as per drawing and as directed at site including materials, transporting, handling, cutting, mixing, placing wherever necessary including filling the hollow portion of pipe bollard with RCC 1:1.5:3 proportion, painting the exposed surface area of steel members with one coat of zinc rich epoxy primer with a minimum dry film thickness of 25 microns followed by two coats of coal tar epoxy paint with a total dry film thickness of 2 coats of 200 microns etc including all labour, materials, tools, transport etc complete as directed by department officers
20
-
-
Supplying and fixing of GI mooring ring with hook & eye 20mm gauge galvanized M.S. rods fixed at regular interval as with suitable bolts and nuts as specified in drawing including labour charges etc., complete as directed by the Departmental Officers.
19
-
-
Supplying and fixing Tyre fender of size 1.10m dia using old tyres of lorries at a spacing of 1.25m c/c including cost of tyres and fixing in position using 30mm bolts to brackets embedded in facia beam of the wharf and jetty, as per the drawing enclosed, as per standard specification and as directed by the departmental officers - Tyre fenders
56
-
-
Dredging in front of existing, proposed quay and in the entire harbour basin, entrance channel/inlet from creek to sea from existing levels to specified levels and slopes in the area marked in the drawing in all types of soils, pebbles, soft rock etc. dredgable by suction cutter/ grab/ backhoe or any other suitable method, carrying/ transporting in hopper barges/pipelines and disposing by depositing either in the marked reclamation area and/ or in the dumping area located at an average distance of 6 to 8 Kms as per the directions and to the complete satisfaction of EIC including all charges of mobilisation, demobilisation of machineries / equipments, men, materials etc. complete with all lead and lift.
2100
-
-
Supplying and laying of Impregnated Bitumen pad 20mm thick 75mm depth for expansion joints as per standard specifications and as directed including all labour for operations, tools, plants and equipments, fuel etc complete as directed by department officers
21
-
-
Sub Total Amount for above all items (excluding GST)
1
-
-
GST 18% for above SubTotal Amount
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements