Engineering Projects India Limited Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Engineering Projects India Limited Tender

Works
Civil And Construction
Eprocure
Opening Date10 Oct 2024
Closing Date23 Oct 2024
Tender Amount₹ 4,81,10,920 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.2.2) Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 500 m.

-

-

-

... More
2.2.2.1) All kinds of soil

300

-

-

... More
2.2.3) Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.

-

-

-

... More
2.2.3.1) All kinds of soil.

570

-

-

... More
2.2.5) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 500 m and lift upto 1.5 m.

222

-

-

... More
2.2.7) Providing and laying minimum 230 mm thick dry rubble (soling) packing for foundation with approved hard stone set in regular lines, hand packed, filling the interstices with small stone chips and sand, ramming, watering and compacting, etc. complete as directed by Engineer-In-Charge.

125

-

-

... More
2.2.8) Filling in Plinth with approved CNS (cohesive non expansive soil) free from vegetations, brought from outside including supply in layers not exceeding 20 cms in thickness, confining the fill, and consolidating / compacting the deposited layer by mechanical means / compactors, plate vibrators and watering etc., to achieve desired density as specified complete as per specification and as directed by Engineer-In-Charge. (Quoted rate to include cost of compaction to achieve at least 95% modified Proctor Density of refilled excavated earth.)

900

-

-

... More
2.2.10) Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :

-

-

-

... More
2.2.10.1) All kinds of soil

-

-

-

... More
2.2.10.1.1) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

1898.4

-

-

... More
2.2.10.1.2) Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia

31.6

-

-

... More
2.2.11) Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m.

-

-

-

... More
2.2.11.1) All kinds of soil

-

-

-

... More
2.2.11.1.1) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

172

-

-

... More
2.2.11.1.2) Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia

70.4

-

-

... More
2.2.12) Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :

-

-

-

... More
2.2.12.1) Ordinary rock :

-

-

-

... More
2.2.12.1.1) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

20

-

-

... More
2.2.13) Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (including dewatering)

-

-

-

... More
2.2.13.1) Ordinary rock :

-

-

-

... More
2.2.13.1.1) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

20

-

-

... More
2.3) PLAIN CEMENT CONCRETE WORK

-

-

-

... More
2.3.1) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
2.3.1.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).

95

-

-

... More
2.3.1.2) 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).

15

-

-

... More
FORMWORK

-

-

-

... More
2.4.1) Centering and shuttering including strutting, propping etc. and removal of form for all heights :

-

-

-

... More
2.4.1.1) Foundations, footings, bases of columns, etc. for mass concrete.

200

-

-

... More
2.4.1.2) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

950

-

-

... More
2.4.1.3) Suspended floors, roofs, landings, balconies and access platform

155

-

-

... More
Reinforcement Note:- 1) Thereinforcement consumed shall be measured as per client approved measurements.

-

-

-

... More
2.4.2) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.

-

-

-

... More
2.4.2.1) Thermo-Mechanically Treated bars HYSD Fe500D or more (Including Supply)

16700

-

-

... More
2.4.2.1 a) Thermo-Mechanically Treated bars HYSD Fe500D or more (Excluding Supply)

10000

-

-

... More
2.4.4) Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of cantering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Minimum Cement content shall be 350 kg/cum)

-

-

-

... More
2.4.4.1) All works upto plinth level

250

-

-

... More
2.4.4.2) All works above plinth level upto floor V level

15

-

-

... More
2.4.5) Extra for providing richer mixes at all floor levels.

-

-

-

... More
2.4.5.1) Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Minimum Cement content shall be 360 kg/cum)

-

-

-

... More
2.4.5.1.1) All works upto plinth level

250

-

-

... More
2.4.5.1.2) All works above plinth level upto floor V level

15

-

-

... More
2.4.12) Providing and applying water swellable-bar at starter & all construction joints, of c/section 20mmX5mm, it shall have unrestrained volumetric expansion more than 200% in 30 days, Hydrostatic pressure resistance of 50 meters. It shall be fixed to the concrete using a gun grade hydrophilic adhesive / or mechanically fixed by non corrosive nailing as recommended by manufacturer complete as directed by engineer in charge.

140

-

-

... More
2.6.4.1) Providing & Applying 2 coats of CFTRI approved, waterproof coating with high performance two component pre-packed cementitious waterproofing, with a mix ratio of (liquid: Powder), parts by wt. - 1:1.4 @ 2.2 Kg/sqm to achieve DFT of 1.5mm over the wall & floor surface as per the manufacturers’ specification & drawing with the turnkey execution to be done by the manufacturer through its in house subsidiary execution company and with 10 years composite warranty against leakages, to be provided by the principal manufacturer / civil contractor. All the coats to be applied in right angle to each other. The coating shall have following properties: Tensile strength : 2.6 N/mm2 as per ASTM D 412, Elongation at break, % : 120 as per ASTM D 412, Adhesion strength : 1 N/mm2 as per ASTM D 4541, crack bridging : 2mm as per ASTM C 836, Water penetration (5 bar pressure) : 1% as per BS EN 12390, Hardness, Shore A : 60 as per ASTM D 2240, RCPT permeability : 92% as per ASTM C 1202-97, including proper surface preparation as per manufacturers' specification, cleaning work, removal of loose concrete and filling cracks with polymer modified mortar using SBR Latex, URP. All the honeycombed areas & construction joints shall be identified and injected with cement slurry admixed with expansive additive, AM @ 225gms / bag of cement.

450

-

-

... More
Making of angle fillets all around the periphery of the wall with polymer modified mortar using SBR Latex, URP, etc, complete. Protection Cum Hygiene Coat: Providing & applying 2 coats of two component, water-based epoxy resin with additive fillers, anti-algae, anti-fungal, Non-flamable, Non-toxic, hygiene cum damp-proof coating @ 4 sqm / Kg, as directed by the manufacturer with the turnkey execution to be done by the manufacturer through its in house subsidiary execution company and with 10 years composite warranty against leakages, to be provided by the principal manufacturer / civil contractor. The coating shall be Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA. Mixing Ratio (Base: Hardner: Water) – 1:1:1, Specific Gravity : 1.2, Water vapour permeance : 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2.5 N/mm2 as per ASTM D 4541 : 02, as per manufacturers' specification, etc, complete as directed by engineer in charge.

-

-

-

... More
2.6.5) UG TANK EXTERNAL AREAS

-

-

-

... More
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be included in this item). Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.

-

-

-

... More
2.6.5.1) Using rough kota stone.

70

-

-

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :

-

-

-

... More
2.6.5.2) Using rough kota stone.

600

-

-

... More
2.6.6) Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :

-

-

-

... More
2.6.6.1) Serrated with central bulb (225mm wide, 8-11mm thick).

140

-

-

... More
2.6.7) WATERPROOF SEALING AROUND THE UTILITIES/ PIPES PASSING THROUGH RCC WALL ETC

50

-

-

... More
Supplying & sealing the pipe inserts, etc provided in the floor & walls with 1.5 mm thick two sided non-reinforced polymerized bituminous self adhesive Tape, to seal the joint between pipes/inserts and the core cuts. The Tape shall have Softening point (R&B) 60⁰C as per ASTM D 36, Elongation, (Compound) 500% as per ASTM D 412, Water absorption at 24 hrs 0.3 as per ASTM D 570, Water permeability @ 5bar : Nil as per BS EN 12390, Adhesion strength : 1.0 N/mm as per ASTM D 1000, Cold temperature flexibility -6⁰C as per UEAtc, followed by grouting the gaps around the pipe / inserts with a non shrink cementitious waterproof grout, 10M, shall conform to ASTM C 109 - 1999 18, ASTM C 1107, Grade C,all followed by sealing with Liquid Applied PU flashing of Flexi PU with reinforcing polyester mesh embedded between the two coats of Flexi PU, at the junction of the pipes and slab / wall area, including proper cleaning of the junctions and sealing the junction with PU sealant conforming to ASTM C-920-S, NS, 25 & BS EN ISO—11600: 2003 Type F & G as per manufacturers' specification, etc, complete as directed by engineer in charge.

-

-

-

... More
2.7.2) Drilling with core cutting machine in RCC slabs, walls etc. wherever required in buildings, manholes,ducts etc. for laying pipes, and making good the same to give an even finish . The rate shall include the cost of drilling core, providing water proofing compound for sealing the joints around the pipes, nominal reinforcement wherever required, scaffolding and labour charges for working at all levels, leads and heights. (Maximum thickness of RCC members shall be 300mm) and as directed by Engineer-In-Charge.

-

-

-

... More
2.7.2.1) Upto 200mm dia

5

-

-

... More
2.7.17) Providing granular bedding with carefully compacted backfill at all level using graded hard crusher broken stone 100% passing through 20 m sieve,20-50% passing through 10 mm sieve and 100% retained on 6 mm sieve,laying in layers not more than 15 cm thick including ramming,watering,compaction etc.complete for pipe bedding and surrounding as per drawing and as directed by the engineer in charge.(Width of bedding=OD+400 mm)

800

-

-

... More
2.7.18) Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete

-

-

-

... More
2.7.18.1) 150 mm dia RCC pipes.

448.8

-

-

... More
2.7.18.2) 300 mm dia RCC pipes.

1074.8

-

-

... More
2.7.18.3) 450 mm dia RCC pipes.

88

-

-

... More
2.7.18.4) 600 mm dia RCC pipes.

9.6

-

-

... More
3.5.8) Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

200

-

-

... More
10.0) EXTERNAL SERVICES WORKS

-

-

-

... More
10.1) Sewerage system

-

-

-

... More
10.1.1) Manholes

-

-

-

... More
10.1.1.1) Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg):

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

28

-

-

... More
10.1.1.2) Extra for depth for manhole

-

-

-

... More
size 90 X 80 cm

-

-

-

... More
10.1.1.2.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

10

-

-

... More
10.1.1.3) Constructing brick masonry circular type manhole 0.91 M. internal dia at bottom and 0.56 M. dia at top with F.P.S. bricks in cement mortar 1:4 (1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size ) finished with a floating coat of neat cement all complete as per standard design

-

-

-

... More
0.91 M deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS : 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 gradded stone aggregate of 20 mm nominal size) including centering shuttering all complete with excavation, footrest and 12 mm thick cement plaster at the external surface.

-

-

-

... More
10.1.1.3.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

96

-

-

... More
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m

-

-

-

... More
10.1.1.3.2) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

42

-

-

... More
10.1.1.4) Constructing brick masonry circular manhole 1.22 M. internal dia at bottom and 0.56 M. dia at top with F.P.S. bricks in cement mortar 1:4 (1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size ) finished with a floating coat of neat cement all complete as per standard design

-

-

-

... More
1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete with excavation, foot rests and 12 mm thick cement plaster at the external surface.

-

-

-

... More
10.1.1.4.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

18

-

-

... More
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m

-

-

-

... More
10.1.1.4.2) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

5

-

-

... More
10.1.1.5) Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :

-

-

-

... More
2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete with excavation, foot rests and 12 mm thick cement plaster at the external surface.

-

-

-

... More
10.1.1.5.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

19

-

-

... More
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m :

-

-

-

... More
10.1.1.5.2) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

10

-

-

... More
10.1.1.6) Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS:10910, on 12 mm dia. Steel bar conforming to IS:1786, having minimum cross section as 23mm x 25 mm and overall minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded leg having 2 mm tread on top surface by ribbing or chequering besides necessary and adequated anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per spaecifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

911

-

-

... More
Cement Plaster 1:3 (1cement:3 coarse sand) finished with a floating coat of neat cement

-

-

-

... More
10.1.1.7) 12mm thick cement plaster

812

-

-

... More
10.1.1.8) Providing sand cast iron drop connection externally for 60cm drop from branch sewer line to main sewer manhole including inspection & cleaning eye with chain & lid , sand cast iron drop pipe and bend encased all round with cement concrete 1:5:10( 1cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size) with all centering and shuttering required , cutting holes in walls and making good with brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand) plastered with cement mortar 1:3 ( 1cement : 3 coarse sand) on inside of the manhole wall, lead caulked joints between sand cast iron pipes and fittings , stiff cement mortar 1:1 ( 1 cement : 1 fine sand) joints between sand cast iron tee and S.W. pipe, making required channels complete as per standard design and specifications:

-

-

-

... More
10.1.1.8.1) 150mm dia. sand cast iron drop connection

4

-

-

... More
10.1.1.9) Extra for depths beyond 60cm of sand cast iron drop connection complete:

-

-

-

... More
10.1.1.9.1) For 150mm dia. sand cast iron drop connection

4

-

-

... More
10.1.1.10) Providing and fixing square mouth S. W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:

-

-

-

... More
150x100mm size P type

-

-

-

... More
10.1.1.10.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

28

-

-

... More
Making soak pit 2.5m diameter 3.0metre deep with 45x45cm dry brick honey comb shaft with bricks and S.W. drain pipe 100mm diameter, 1.8m long complete as per standard design.

-

-

-

... More
10.1.1.10.2) with common burnt clay F.P.S.(non modular) bricks of class designation 7.5

4

-

-

... More
10.1.1.11) Providing, installing and commissioning readymade type RCC Septic tank 1200mm Dia, 2500 mm long with covers for 50 users as per drawings / details etc including making connections to inlet, outlet, dewatering, complete, as directed by Engineer In Charge.

4

-

-

... More
10.1.1.12) Providing , supplying Prefab Grease separator plant for 600 meals per day and operation hours 8 hrs. for  under ground installation with suitable top sections. Emptying & cleaning via. Shaft manhole cover with connections for inlet & outlet.  Make : Nihva Aco 

1

-

-

... More
10.5) POTABLE, RECYCLED / NON-POTABLE WATER SUPPLY SYSTEM

-

-

-

... More
10.5.1) Supplying, laying, jointing, testing and commissioning of UPVC pipes conforming to ASTM D-1785 for pipes schedule 80 and ASTM D-2467fittings of schedule 80 with all fittings like tees, elbows, bends, unions, coupling, reducer tees, collars etc. solvent cement of medium body IPS brand or equivalent including supporting on walls complete Pipe to be laid below ground level in trenches/direct buried up to required depth as per drawing. including excavation in all kind of soil, dewatering, making sand bed as per specification and PWD standards, backfilling, dewatering, ramming & removing the surplus excavated material and making good the same complete as required. Cost shall be inclusive of providing protection to pipe all round / haunches for road crossing as per specification and disposal of surplus soil from site. (Pipe dia mention in this section are clear internal pipe diameter and contractor has to select the pipe with dia nearest diameter to this) including excavation in ground and making Soil backfilling as per previous condition. pipes shall be run confirming to CPWD norms. complete as per Technical specification, approved method statement and drawings. (External water Supply : Domestic, Drinking,Flushing, Irrigation tapping)

-

-

-

... More
10.5.1.1) 80 mm OD. (upto the depth of 1.5 mtr)

1407

-

-

... More
10.5.1.2) 100 mm OD. (upto the depth of 1.5 mtr)

988

-

-

... More
10.5.2) Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :

-

-

-

... More
10.5.2.1) 100 mm dia Ductile Iron Class K-7 pipes

52

-

-

... More
10.5.3) Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket :

-

-

-

... More
10.5.3.1) 100 mm dia pipes

10

-

-

... More
10.5.4) Providing and laying S&S CI standard specials such as tees bends collars tapers and caps etc suitable for flanged jointing as per IS : 1538.

-

-

-

... More
10.5.4.1) Upto 300mm dia

1

-

-

... More
10.5.5) Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
10.5.5.1) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

26

-

-

... More
10.5.6) BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified

-

-

-

... More
10.5.6.1) 65 mm dia

12

-

-

... More
10.5.6.2) 80 mm dia

4

-

-

... More
10.5.6.3) 100 mm dia

10

-

-

... More
10.5.7) Providing and laying non-pressure NP3 class socketed R.C.C. pipes (heavy duty) jointed with EPDM gasket (ISI marked) including testing of joints and checking and making good leakages wherever required complete as per directions of the Engineer.

-

-

-

... More
10.5.7.1) 200 mm dia (ID)

150

-

-

... More
10.5.7.2) 300 mm dia (ID)

100

-

-

... More
10.5.8) Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
10.5.8.1) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

4

-

-

... More
10.5.9) Providing and fixing enclosed type water meter (bulk type) confirming to IS:2373 and tested by Municipal Board complete with bolts,nuts, rubber insertions etc. (The tail piece if reuired will be paid seperately)

-

-

-

... More
10.5.9.1) 100 mm dia nominal bore

4

-

-

... More
10.5.10) Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.

-

-

-

... More
10.5.10.1) 100mm dia

4

-

-

... More
11.0) ROAD WORKS

-

-

-

... More
11.1) Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.

16201

-

-

... More
11.2) Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).

3646

-

-

... More
11.3) Construction of granular sub-base by providing close graded Material conforming to pecifications, mixing in a mechanical mix plant at OMC,carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineerin- Charge.

-

-

-

... More
11.3.1) With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30.

3106

-

-

... More
11.4) Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.

3389

-

-

... More
11.5) Providing and applying tack coat using bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.

-

-

-

... More
11.5.1) With medium setting bitumen emulsion

-

-

-

... More
11.5.1.1) On W.B.M / W.M.M. @ 0.4kg/sqm

8900

-

-

... More
11.6) Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge.

-

-

-

... More
11.6.1) 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.

445

-

-

... More
11.7) Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.

-

-

-

... More
11.7.1) 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.

267

-

-

... More
11.8) Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete.

-

-

-

... More
11.8.1) New work (Two or more coats)

614

-

-

... More
11.9) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
11.9.1) 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

174

-

-

... More
11.1) Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

223

-

-

... More
11.11) Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete as per direction of Engineer In Charge- On concrete kerb

1485

-

-

... More
12.0) Landscaping

-

-

-

... More
12.1) Landscape Works : Softscape

-

-

-

... More
12.1.1) Excavation,Site Dressing and Land Modulation

-

-

-

... More
12.1.1.1) Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

23900

-

-

... More
12.1.2) Site Cleaning & Soil Restoration

-

-

-

... More
12.1.2.1) Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.

40387

-

-

... More
12.1.2.2) Removing good quality shrubs and trees and storing them in dry cement bags by utilising the excavated soil. Excavated shrubs and trees shall be stored till further instructions in an area stated as the nursery zone. Watering the same to achieve 100% survival.

1

-

-

... More
12.1.2.3) Existing Topsoil to be excavated for restoration to a depth of 200 mm (not more than 400 mm) and separated from subsoil debris and stones larger than 50 mm diameter to be stockpiled to a height of 400 mm in designated area. Stockpiled topsoil to be protected from erosion during storage by installing earthen berms/solid walls/temporary grass plantation/covering with mulch/ plastic sheets. Stockpiled topsoil to be protected with sand bags/solid walled enclosures (2 feet high) on all sides for containment. Appropriate drainage channels to be dug around the storage area to prevent flooding of the top soil storage area as instructed by engineer incharge.

7900

-

-

... More
12.1.3) Rough Dressing

-

-

-

... More
12.1.3.1) Rough dressing the trenched ground including breaking clods.

29511

-

-

... More
12.1.4) Fine Dressing

-

-

-

... More
12.1.4.1) Fine dressing of the ground.

29511

-

-

... More
12.1.4.2) Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge.

10

-

-

... More
12.1.5) Mixing and Spreading of Good Soil and Manure

-

-

-

... More
12.1.5.1) Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately).

6663

-

-

... More
12.1.5.2) Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in- charge

6663

-

-

... More
12.1.5.3) Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :

-

-

-

... More
12.1.5.4) Holes 90 cm dia, and 90 cm deep

631

-

-

... More
12.1.5.5) Holes 60 cm dia, and 60 cm deep

750

-

-

... More
12.1.5.6) Holes 45 cm dia, and 45 cm deep.

630

-

-

... More
12.1.5.7) Excavation for raising Lawn on Soft surface: Excavating the ground to the depth of 30 cm removing excavated material from the site.

3820

-

-

... More
12.1.5.8) Excavation for planting Hedges/ Edges/ Flower Beds on Soft surface: Excavating the ground to the depth of 30 cm removing excavated material from the site.

3440

-

-

... More
12.1.5.9) Excavation for preparing Shrubbery on Soft surface: Excavating the ground for preparing Shrubbery in the earth / murum/ sand for a depth of 0.60 m

440

-

-

... More
12.1.5.10) Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).

6663

-

-

... More
12.1.6) Weeding

-

-

-

... More
12.1.6.1) Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.

10151

-

-

... More
12.2) Softscape Works and Plantation

-

-

-

... More
12.2.1) Good Garden Soil

-

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage complete (earth measured in stacks will be reduced by 20% for payment).

2400

-

-

... More
12.2.2) Cow Dung Manure

-

-

-

... More
Supplying and stacking of well decayed cow dung manure at site including and carriage complete (Cow dung manure measured in stacks will reduced by 8% for Payment).

1200

-

-

... More
12.2.3) Grassing

-

-

-

... More
12.2.3.1) Grassing with selection No. 1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately).

-

-

-

... More
12.2.3.3) With grass Turf / Carpet Grass

1277

-

-

... More
12.2.3.4) Planting Doob grass, Cynadon dactylon at 50mm c/c

2330

-

-

... More
12.2.3.5) Planting Jumping / Korian / Zoycia grass at 25mm c/c

210

-

-

... More
12.2.3.6) Planting Cynadon dactylon in Grass Pavers

1720

-

-

... More
12.2.3.7) Providing and planting good quality lawn suckers of Cynodon dactylon with necessary bed preparation over the restored soil beds on site and apply water to the mix for the period of two weeks, sowing the lawn suckers at 75mm c/c in staggered fashion wherever required, rolling the surface to have a uniform level to avoid water stagnancy and then maintaining the same till well established until the site is ready for soil reuse.

10151

-

-

... More
12.2.3.8) Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (the good earth shall be paid for separately).

5540

-

-

... More
12.2.4) Shrubs, Hedges, Shrubbery and Groundcover Plantation

-

-

-

... More
12.2.4.1) Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).

2859

-

-

... More
12.2.4.2) Planting Shrubs (Labour, transport and unloading) (Excluding cost of plant)

440

-

-

... More
12.2.4.3) Planting Hedges, Shrubbery and Groundcovers (Labour, transport and unloading) (Excluding cost of plant)

3440

-

-

... More
12.2.4.4) Duranta varigated

370

-

-

... More
12.2.4.5) Lantana camara depressa

290

-

-

... More
12.2.4.6) Lantana Yellow

750

-

-

... More
12.2.4.7) Ixora parviflora

70

-

-

... More
12.2.4.8) Wadelia trilobata

2400

-

-

... More
12.2.4.9) Bougainvillea glabra

630

-

-

... More
12.2.4.10) Nerium oleander dwarf

630

-

-

... More
12.2.4.11) Thevetia nerifolia

120

-

-

... More
12.2.4) Trees Plantation

-

-

-

... More
12.2.4.1) Providing well grown trees with minimum average girth of 5 cm and minimum height of 1.5 M above finished level after plantation of specified variety , at desired location & at specified distances. Achieving finished grade level. Planting the tree with appropriate anchoring, leveling the top soil surface as specified after plantation, staking to balance the tree. Including transport to the site & planting , preparation of tree basin, watering & maintaining for 1 month after completion of plantation and replacement of casualties till 1 month.

-

-

-

... More
12.2.4.2) Planting Tree (Labour, transport and unloading) (Excluding cost of plant)

688

-

-

... More
12.2.4.3) Tree List: (Ht. At time of plantation: 1M-1.5M)

-

-

-

... More
12.2.4.4) Albizia odoratissima

30

-

-

... More
12.2.4.5) Bauhinia purpurea

50

-

-

... More
12.2.4.6) Erythrina indica varigated

55

-

-

... More
12.2.4.7) Grevillea robusta

67

-

-

... More
12.2.4.8) Mimusops elengi

65

-

-

... More
12.2.4.9) Plumeria alba

116

-

-

... More
12.2.4.10) Crataeva religiosa

75

-

-

... More
12.2.4.11) Millingtonia hortensis

55

-

-

... More
12.2.4.12) Roystonea regia

5

-

-

... More
12.2.4.13) Cycas Revoluta

73

-

-

... More
12.2.4.14) Dypsis lutescens

19

-

-

... More
12.2.4.15) Peltophorum pterocarpum

8

-

-

... More
12.2.4.16) Cassia nodosa

20

-

-

... More
12.2.4.17) Tabebuia rosea

4

-

-

... More
12.2.4.18) Cassia siamea

4

-

-

... More
12.2.4.19) Plumeria rubra

10

-

-

... More
12.2.4.20) Nyctanthes arbor tristis

12

-

-

... More
12.2.4.21) Saraca indica

9

-

-

... More
12.2.4.22) Michelia champa

11

-

-

... More
12.3) Irrigation System

-

-

-

... More
12.3.1) Manual Irrigation

-

-

-

... More
Providing, Fixing,Testing & Commissioning of Manual pipe irrigation system with all necessary fittings, pumps and related civil works, including all labours, all complete

11100

-

-

... More
12.4) Landscape Works : Hardscape

-

-

-

... More
12.4.1) Leather finish Kota stone slab in various dimensions for outdoor flooring 25 mm thk

-

-

-

... More
Leather finish Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) (Slab thickness 25mm)

290

-

-

... More
12.4.2) Mirror Polished Kota stone slab in various dimensions for outdoor flooring 25 mm thk

-

-

-

... More
Mirror Polished Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) (Slab thickness 25mm)

300

-

-

... More
12.4.3) Unpolished Kota stone tiles for tile edging between plantation 25 mm thk

-

-

-

... More
Unpolished Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) (Slab thickness 25mm)

2000

-

-

... More
12.4.4) Mirror Polished Kota stone slab in various dimensions for outdoor Seating 40 mm thk

-

-

-

... More
Mirror Polished Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) (Slab thickness 40mm)

50

-

-

... More
12.4.5) Cement concrete interlocking pavers with Gravel joint 60mm thk

-

-

-

... More
Providing & Fixing 60 mm thick unishape cement concrete interlocking pavers (monolithic-single layer precast concrete blocks manufactured in gray cement only) in red ( Terra Cotta) Black, Brown or any colour having average crusting strength 40 N/mm² with pigment @ 3% by weight of cement in the footpath, placed on uniformly graded river sand cushioning of average compacted thickness 25 mm properly compacted with mechanical compactor with required level. Filling crushed gravel (gravel dia not bigger than 10mm)in the cavity as per the paver design post complete installation and compation. complete as specified and as directed by the Engineer.

-

-

-

... More
12.4.5.1) Paver with Ash Grey colour

1000

-

-

... More
12.4.5.2) Paver with Terracotta colour

2100

-

-

... More
12.4.5.3) Paver with Brown colour

2110

-

-

... More
12.4.6) Pre-cast cement concrete Grass pavers 60mm thk

-

-

-

... More
Providing and fixing at ground levels, pre cast cement concrete grass pavers as per drawing with M30 grade concrete (Min cement content 380 kg/cum) including providing, laying and fixing HYSD reinforcement of dia. 8 mm and spacing max 200 mm and setting in position over 50 mm thick sand layer etc complete as directed by Engineer.

1706

-

-

... More
12.4.7) Providing & Fixing of stainless steel 304 grade matt finish 3mm Flag pole of 6m height from FGL with pulley Cleat mounted on base plate complete as per directions of engineer in charge ( excluding the cost of RCC foundation. Material Specifiaction Bottom Pipe -220mm 2nd Pipe -150mm 3rd Pipe- 100mm Base plate Dimension 500x50020mm

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.