Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Directorate Of Town Panchayats - DTP Tender
Civil And Construction
Building Construction
Eprocure
Opening Date3 Sep 2024
Closing Date10 Sep 2024
Tender Amount₹ 7,75,000
Costs
EMD
₹ 7,750Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Construction Of Busshelter At Infront Of Dr.mgr Fisheries College And Research Institute In Thalanayar Town Panchayat
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DTP_480395_1Bid Award Id
ViewTender No
442/2024/A1Tender Authority
Directorate Of Town Panchayats ViewPurchaser Address
-Website
http://https://www.tn.gov.in/dtp/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
9
-
-
Supplying & Erecting centering for sides & soffiots including necessary supports & strutting upto 3.29m height for plane surfaces in all floors with all cross bracings using mild steel sheets of size 90 x 60cm & 10 gauge stiffened, welded with steel angle of size 25 x 25 x 3mm for boarding laid over silver oak joists(Country wood) of size 10 x 6.5cm spaced @ about 90cm c/c and supported by casurina props of 10 - 13cm dia. spaced @ 75cm c/c etc., complete complying with standard specifications and as directed by the departmental officers. Rate for 10m2.for the following items.(RCC floor slab, roof slab, Rectangular/ square, Tee/ Ell beams, Lintels, staircase waist slabs, Landing slabs, Landing beam, Portico beam etc., ).
-
-
-
Without Strutting
13.5
-
-
Square Column
24
-
-
Plain Surface
54.5
-
-
Supplying and Fabrication of Steel and placing in position MS / Ribbed tor steel Grills for RCC works as per design given including cost of steel and GI binding wire in Floors etc,. Complete complying with standard specification in force and as directed by department officials.-
810
-
-
Brick work in Cement Mortar in 1:5 ( One cement and Five M-Sand ) using best quality of Country bricks of size 8¾x 4 ¼ x 2 ¾ including all cost of materials and labour charges including Curing charges etc., complete as per Standard Specificationand as directed by department officials.
12.5
-
-
Plastering walls with cement mortar 1:5 (One cement five P-Sand) 12mm thick in all floors and all exposed surfaces including cost and conveyance of materials to site and all labour charges,Curing etc completeand as directed by department officials..
129
-
-
Special Plastering with cement mortar 1:3 (One cement three P-Sand) 10mm thick including cost and conveyance of materials to site and including all labour charges etc complete.
46
-
-
Weathering course in Brick jelly and lime concrete using broken brick jelly of size 20 mm uniform gauge in pure slacked lime ( no sand to be used ) the proportion of brick jelly to lime being 32:12.5 by volume laid over the RCC roof slab in a single layer of required design , slope and finished thickness by beating the concrete with wooden and beaters of approved pattern keeping the surface constantly wet by springing lime Jaggery water etc complete as per standard specification.
1.5
-
-
Finishing the top of Roof with one course of machine pressed tiles of size ( 23x23x2 cm ) approved quality in C.M. 1:3 - 12 mm thick mixed with water proofing compound confirming to IS @ 2 % by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc complete as per standard specification.
18.7
-
-
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
30
-
-
Dadoing walls with the following types tiles of suitable size of approved quality and colour set in cement mortar 1:2 (one cement ,two P -sand); 10mm and pointing with colour cement neatly etc., complete in all floors.
36
-
-
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris, putty, wherever required etc., complete complying with standard specification
48
-
-
Supplying and fixing of M.S. steel grill using M.S. angle frames including cost of M.S. angles (50mm x 50 mm x 6mm) T , L angles, flats and square rods in proper position including labour charges for cutting, welding, and including labour charges for priming cost of red oxide painting and erection in a proper position etc. complete as per standard specification and Grill design , Thickness of square rod are approved by the departmental engineers.
180
-
-
Supply and Fixing of Stainless Steel Hand Rails proper position including labour charges for cutting, welding, and including labour charges for priming cost of red oxide painting and erection in a proper position etc. complete as per standard specification and Grill design , Thickness of square rod are approved by the departmental engineers.
4
-
-
Painting new iron works with two coats of approved quality and color of synthetic enamel paint over the existing red oxide primer in all floor etc., complete as per standard specification.
14.5
-
-
Wiring with 2 x 1.5 sqmm (22/0.3) PVC insulated SC. unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid Pipe on wall and ceiling with PVC accessories and with TW switch box and 5A F.T. switch with painting of suitable Colour for Consealed PVC light point / fan point (For electronic regulator. SD 24
8
-
-
Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15 A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire , and making good of the concealed portion, with suitable colour for concealed power plug point SD 40
2
-
-
Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. SD 89
6
-
-
Supply and fixng of TNEB Moter Board suitable for 3 Phases 100A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2" x 1 1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1 1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 100A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete SD 125
1
-
-
Service Pipe standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work
3
-
-
Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour SD 43
10
-
-
Supply and fixing of 32 Amps DP Switch of 500V with metal clad with fuse and neutral (Side Handle) on suitable TW Board with PWD Earthingincluding cost and conveyance of all materials to site and all labour charges etc complete asper std. specifications. (SD 143)
1
-
-
Supply and run of 2 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V on 7/20 GI bearer
wire for service connection mains of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification (SD 66)
15
-
-