Directorate Of Town Panchayats Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Directorate Of Town Panchayats - DTP Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date23 Feb 2024
Closing Date29 Feb 2024
Tender Amount₹ 1,47,49,157 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 1,89,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Cgf 2023-2024 In Sivagiri Town Panchayat
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DTP_429771_1Bid Award Id
ViewTender No
343/2023Tender Authority
Directorate Of Town Panchayats ViewPurchaser Address
-Website
http://https://www.tn.gov.in/dtp/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Earth work open well excavation complying with relevant clauses of T.N.D.S.S well sinking and with lead upto 10 metre in soft disintegrated rock, soft rock or kankar not requiring blasting. (TNBP No.17,23,24).P First Depth of ( 1.00 m to 2.00 m)
95
-
-
Open well excavation complying with relevant clauses of T.N.D.S.S well sinking and with lead upto 10 metre in medium rock and dense medium rock requiring blasting. (TNBP No.17,23,24).P 2nd depth of 2 metre ( 2.00 m to 4.00 m )
190
-
-
3rd depth of 2 metre.( 4.00 m to 6.00 m )
190
-
-
4th depth of 2 metre.( 6.00 m to 8.00 m )
190
-
-
Open well excavation complying with relevant clauses of T.N.D.S.S well sinking and with lead upto 10 metre in medium rock and dense medium rock requiring blasting. (TNBP No.17,23,24).P 5th depth of 1 meter.( 8.00 m to 9.00 m )
95
-
-
Open well excavation complying with relevant clauses of T.N.D.S.S well sinking and with lead upto 10 metre in Hard grante measured in solid including blasting and stacking .(TNBP No.17,23,24).P 5th depth of 1 meter.( 9.00 m to 10.00 m )
95
-
-
6th depth of 2 metre.( 10.00 m to 12.00 m )
128
-
-
Seventh Depth of 2 metre ( 12.00 m to 14.00 m )
128
-
-
Eighth Depth of 2 metre ( 14.00 m to 16.00 m )
128
-
-
9th depth of 2 metre ( 16.00 m to 18.00 m )
128
-
-
Plain Cement Concrete 1:4:8 mix (One Cement, FourFine Aggregate and eight Coarse Aggregate) Using 40mm ISS HBG metal for foundation and basement including dewatering if found necessary and laid in layer of not more than 15cm thick and consolidated including all cost conveyance of materials and labour charges etc. complete as per standard specifications and as directed by departmental Engineers(TNBP No.28).
12
-
-
Refilling the pipeline trench with loose soil including all accidental charges etc..complete as per twad linear measurements etc..complete
4400
-
-
Brick Work in Cement Mortor 1:5 Mix (one cement, five M.Sand ) using new best country Bricks of size 8 ¾” x 4 ¼” x 2 ¾” from approved quarry including cost and conveyance of all materials to site. loading and unloading charges and labour charges for mixing, laying and curing etc. complete. complying with std. specifications.
10.5
-
-
Supplying, fabricating and placing in position mild steel or TMT rods for all reinforced cement concrete works as per design given including cost of steel and binding wire with all conveyance and lead charges in all floors etc.complete complying with standard specifications and as directed by the deparmental engineers.TNDSS NO: 97 V,VI (S6) VII (S6) VII-3 P
16100
-
-
Supplying and erecting centering for sides and soffits including supports and strutting up to a height of 3.05 metre high for plain surfaces such as RCC slabs, beams TEE or ELL beams, lintels staircase beams etc., in all floors with all cross bracings using mild steel B.G. 10 sheets of size 90 cm X 60 cm stiff ended with welded mild steel angles laid over silver oak(Country wood) joists of size 10 X 6.5 cm spaced at about 90 cm centre to centre and supported by casurina props of 10 cm to 13 cm dia spaced at 75 cm centre to centre complete complying eith standard specification in all floors. . TNDSS NO : 30 & 86.P shuttering
28
-
-
For 0.00 to 3.30m (Plane surface)
59
-
-
For 0.00 to 3.30m (Curved Surface)
729
-
-
Square column
15
-
-
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) From 0 m to 4.5m above GL
31
-
-
Up to 1.5m below GL
32
-
-
1.50 m to 4.50 m Below GL
44
-
-
4.50 m to 9.00 m Below GL
54
-
-
Supplying and fixing of Mild steel door,grill gate,window including cost and conveyance charges to site fixing in its position and all labour charges etc complete.
2082
-
-
Plastering with CM 1:5 (One part of cement & five parts of sand) mix for 12mm thick including cost and conveyance of all materials to work site and including all labour charges for mixing, laying, curing,finishing etc., complete as per standard specifications and as directed by departmental Engineers – TNDSS NO: 61 V,VI (S4)
115
-
-
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. TNBP No:66-A (Sl.No.358) P
115
-
-
Painting with two coats of Approved colour of best quality synthetic enamel paint, painting over new iron work including cost and conveyance of all materials and all labour charges etc. complete as per Standard specification and as directed by the departmental officers. (New Iron Surface).TNBP No:66&66-A
5
-
-
Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC.unsheathed Cu. Conductor of 1100 V grade in suitable PVC rigidpipe on wall and ceiling with PVC accessories and with TW switch box and 5A F.T. switch with painting of suitableColourfor open PVC light point / fan point (For electronic regulator)SD 18 ISI make with standard specification
5
-
-
Supply and run of 4 of 4sqmm (56 / 0.3) insulated SC unsheathed Cu.Cconductor of 1100V grade on 7/20 GI bearer wire for service connection mains. SD 61 ISI make with standard specification.
15
-
-
Supply and run of 4 x 4 sqmm (56/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in 25mm dia GI Pipe ( Class ‘B’) suitably bent at both ends with necessary angle iron upright and end supports for mains. SD 72 ISI make with standard specification.
2
-
-
Supply and fixing of 32 Amps DPIC switch of 500 V with metal clad with fuse and netural TW Board with earth connection only. SD 143 ISI make with standard specification.
1
-
-
Supply and fixing of 4’ x 40 watts single street light fitting etc., complete ISI make with standard specification.SD93
2
-
-
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. (600 Lpmx 40 m Head)
2
-
-
Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). (7.5 HP)
2
-
-
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable withproper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.SL.NO 17C-2 above 5HP
2
-
-
Supply and delivery the following HDPE PIPES / GI pipes and specials including cost and conveyance of materials to site etc complete. HDPE PIPES PN 10 140 mm
4400
-
-
150mm DI Pipe K7 Class
330
-
-
150 mm DI specials
50
-
-
150mm dia sluice valve
8
-
-
80 mm GI coupling
10
-
-
80mm GI Elbow
10
-
-
80mm MS clampset
2
-
-
80mm GI flangest
10
-
-
150 MM Non return valve
3
-
-
80 mm GI pipe
36
-
-
HDPE 140 degree bend
30
-
-
Lowering of DI pipes and specials in to the trenches carefully laying to proper grade and alignment with simplex joints and testing to the required pressure etc, complete and as directed by officers GI Pipes 150mm DI Pipe K7 Class
330
-
-
Lowering HDPE pipes and specials to trench and laying to proper grade and alignment and asdirected by the Officers HDPE PIPES PN 10 140 mm
4404
-
-
Dewatering using 7.5hp t diesel engine pumpsetincluding Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete
300
-
-
Conducting geophysical survey for selecting open well point / yield list etc.. Complete
1
-
-
Supply and delivery of pvc insuated and sheathed 3 core 4.00 sqmm flat type copper cable conforming to IS 694/1990 etc..complete
160
-
-
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Officers
734
-
-
Weathering course with concrete brocken brick jelly 20mm size in pure slacked lime (no sand to be added) over roof slab the proportion of brick jelly to lime being 32 to 12.5 well beaten with wooden beaters for giving required slope and thickness as directed by the departmental officers.
1
-
-
Terrace flooring with Hydraulic pressed tiles of size 20*20*2cm laid in c.m 1:3 (one cement three sand) mixed with crude oil 10 %, by weight of cement and pointed with same oiled mortor etc complete as per SS
11.2
-
-
Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia and 1.80m height) vertical with horizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm dia reflectors including earth work excavation for fixing vertical posts and finallyremoving and stacking the materials safely for further use etc., complete and as directed by TWAD Board officers.
3000
-
-
Testing of pipes for water supply with hydraulic testing equipment by filling with water (including cost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete for the following diametres of pipes.140 mm hdpe pipe
4400
-
-
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. 125 LPM x 25 m head
1
-
-
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). For 3HP
1
-
-
Labour Charges for erection of Horizontal shaft, centrifugal pumpset (Coupled/Monoblock) in bore well/Open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPIC switches starter, Voltmeter, Ammeter, Capacitor single phasing preventor and laying and jointing the cables and twin earthing as per IE rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by EB authorities. upto 3HP
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements