Directorate Of Town Panchayats Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Directorate Of Town Panchayats Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date2 Dec 2024
Closing Date12 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Roc No 131/2024 Improvement Of Water Supply System To Pandamangalam Town Panchayat Namakkal Dis

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SDR - (Not Requiring Blasting) Earth work excavating and depositing on bank with initial lead of 10 m & initial lift of 2m in Soft disintegrated rock, laterite, soft rock or kankar, not requiring blasting with standard specification.

229

-

-

... More
For 2nd depth of 2 m to 3 m

1

-

-

... More
In soft disintegrated rock,laterite,soft rock or kankar not requiring blasting.

95

-

-

... More
Sand Filling with clean river sand complying with standard specification including watering ramming and consolidation etc.,complete and as directed by TWAD BOARD Officers.

9

-

-

... More
Sinking of infiltration well of 4.50m internal dia and 5.5m external dia below water level including ali incidental charges in light or sandy soil.

1

-

-

... More
1st Depth of 2m

2

-

-

... More
2nd Depth of 2m

4

-

-

... More
3rd Depth of 2m

4

-

-

... More
4th Depth of 2m

4

-

-

... More
5th Depth of 2m

4

-

-

... More
6th Depth of 2m

1.6

-

-

... More
Porous concrete in CC 1:4 (One cement and four hard broken granite jelly of a size 20mm) for steining of infiltration well excluding cost of centering but including curing etc., complete and as directed by the Engineers @ well curb including all labour charges etc, complete.

96

-

-

... More
R.R. masonry in CM 1:5 mix for foundation and basement as per specification and as directed by the Departmental Officers.

20

-

-

... More
Brick work in CM 1:5 mix using country bricks of size 22cm x 11cm x 7cm for the following works including curing etc., complete complying with standard specification and as directed by the Departmental Officers.

1

-

-

... More
Upto basement:

0.4

-

-

... More
Upto 4.50 m height above basement

13

-

-

... More
Above 4.5m height from basement

4

-

-

... More
Plain cement concrete 1:1.5:3 (One cement, one and a half sand and three hard granite broken stone of 20mm size ISS gauge) including mixing, placing, ramming, finishing, curing etc., complete in accordance with specifications and as directed by TWAD Board Officers.

7

-

-

... More
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -

4.4

-

-

... More
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials)

1

-

-

... More
Beyond 1.5 m below GL

72.3

-

-

... More
Upto 1.5 m below G.L.

98.8

-

-

... More
Upto 4.50 m ht. Above G.L.

34.7

-

-

... More
From 4.50 m to 7.32 m ht. From G.L.

12.4

-

-

... More
From 7.32 m to 10.98 m ht. From G.L.

20.6

-

-

... More
From 10.98 m to 14.64 m ht. From G.L.

20.8

-

-

... More
From 14.64 m to 18.30m

115.9

-

-

... More
From 18.3 m to 21.96m

44.8

-

-

... More
Centering for sides and soffits for RCC members (plane surface) for the following works including shuttering, strutting to the centering and providing supports etc. complete using M.S. sheets of size 90mm x60mm and BG 10 gauge stiffened with MS angles of size 25mm x25mm x3mm laid over country wood joists of size 10cm x63mm spaced at about 90cm c/c and supported by casurina props of size 10cm to 13cm dia. spacing at 75cm c/c and as directed by the Departmental Officers The centering materials should be supplied by the contractor and centering removal after the specified stripping time of the concrete as per IS 456-1978

1

-

-

... More
Plain surface

1

-

-

... More
Below GL upto 3.3m above GL

291

-

-

... More
3.3 m to 4.3m ht from GL

342

-

-

... More
6.3 m to 7.3m ht from GL

26.71

-

-

... More
7.3 m to 8.3m ht from GL

75

-

-

... More
10.30 m to 11.30m ht from GL

50.99

-

-

... More
11.3 m to 12.3m ht from GL

49.88

-

-

... More
14.3 m to 15.3 m from GL

180

-

-

... More
15.3 m to 16.3 m from GL

315

-

-

... More
Square Column

1

-

-

... More
0 to 3.3m ht above GL and below GL

159

-

-

... More
3.3m to 4.3m ht from GL

29

-

-

... More
4.3 m to 5.3m ht from GL

33

-

-

... More
5.3 m to 6.3m ht from GL

33

-

-

... More
6.3 m to 7.3m ht from GL

32

-

-

... More
7.3m to 8.3m ht from GL

29

-

-

... More
8.3 m to 9.3m ht from GL

33

-

-

... More
9.3 m to 10.3m ht from GL

33

-

-

... More
10.3 m to 11.3m ht from GL

30

-

-

... More
11.3 m to 12.3m ht from GL

31

-

-

... More
12.3 m to 13.3m ht from GL

33

-

-

... More
13.3 m to 14.3m ht from GL

33

-

-

... More
14.3 m to 15.3m ht from GL

23

-

-

... More
15.3 m to 16.3m ht from GL

1.03

-

-

... More
Curved surface

1

-

-

... More
From 0 to 3.3m from floor level

1344

-

-

... More
from 3.3m to 4.3 m ht from floor level

87

-

-

... More
Circular Column

1

-

-

... More
For 0.00 to 3.30 M (FOR ROUND COLUMN)

1.48

-

-

... More
Supply, fabrication,placing in position of steel rods cutting, tying etc., complete including cost of reinforcements

55753

-

-

... More
Supply and fabrication charges for making clampset sitable for Connecting main including cost of bending drilling holes suitable for bolts, painting one coat of red oxide etc complete and as directed by TWAD Board officers. )

1215.1

-

-

... More
Supply and delivery of bolts and nuts 20mm dia and above x 90mm etc.,

37.58

-

-

... More
Plastering with CM 1:5 ,12mm thick for outside walls complying with standard specification and as directed by the Departmental Officers.

135.06

-

-

... More
Special ceiling plastering with CM 1:3 mix 10mm thick complying with standard specification and as directed by the Departmental Officers.

30.71

-

-

... More
Damp proof course in CM 1:3 mix, 20 mm thick using 5% crude oil over basement.

7.11

-

-

... More
Providing granolithic floor finish of 25mm thickness with plain cement concrete 1:2:4 (One Cement, Two crushed sand (M-Sand) and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification

24

-

-

... More
Weathering course with concrete broken brick jelly of 20mm size in pure slaked lime (No sand to be used) over roof slab the proportion of brick jelly to lime being 32:12.5 for required depth of 80mm for giving required slope and thickness to roof as required will beaten with wooden beaters etc., complete complying with standard specification and as directed by the Departmental Officers.

1.92

-

-

... More
Finishing the top of roof (weathering course) with one course of pressed tiles of size 20cm x 20cm x 2cm using CM 1:3 mixed with crude oil 10% by weight of cement painted with same oiled mortar complying with standard specification and as directed by the Departmental Officers.

24

-

-

... More
Supplying and fixing of cutstones size 0.45x 0.45x0.15m in CM 1:3 below the inlet pipe

0.1

-

-

... More
Supply, delivery and fixing in position of CI manhole of size 0.60 m x 0.60 m including locking arrangement, cost of materials etc. complete and as directed by the officers.( with frame , heavy duty)

10

-

-

... More
Providing RCC Ventilator of 0.30 m dia using 20mm HBG stone including cost of all materials, centering, shuttering,strutting,reinforcement, placing of concrete, finishing, curing and fixing in position on the roof slab with mosquito proof net arrangement and etc., complete and as directed by TWAD Board officers.

8

-

-

... More
Supply and Delivery Fabrication of MS doors and windows with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete

1

-

-

... More
Fully panelled Double leaf - Door (1 x 2.1 m)

1

-

-

... More
Fully panelled Double leaf - Window (without Ventilator) ( 0.6 x 0.9 m )

1

-

-

... More
Supply delivery and fixing of CI steps in position at 30cm centre to centre in staggered manner and as directed by departmental officers.

42

-

-

... More
Construction of RCC spiral staircase in RCC 1:1.5:3 (1 Cement : 1.5 Sand : 3 Coarse Aggregate) using 20 mm HBGS of 1.80 m diameter of required height for approach to the roof of Service Reservoir with RCC Handrails including earthwork excavation, providing CC 1:4:8 mix, RCC footing 1:1.5:3 mix, GL platform etc., and also including cost of steel reinforcement, fabrication charges, scaffolding, centering, precasting charges, cement, painting etc. complete as per standard specifications and as directed by Engineer. The staircase shall be braced to the column of service reservoir at suitable interval. (in the BOQ, quantity column the exact height to be mentioned from GL to roof slab bottom to get total value of work to be done.

2

-

-

... More
Providing and fixing in position of precast RCC (1:11/2:3) Hand rails of approvced design for one meter height by using 20mm HBG stone including cost of all materials, centering, shuttering, strutting, reinforcement, placing of concrete, finishing, curing and fixing in position on the roof slab etc.,complete and as directed by dept officers.

68

-

-

... More
Supplying and fixing in position of RCC in side access lader of following size using 20mm size HBS jelly including cost of all materials,centring, shuttering,strutting,fabrication and placing in position of reinforcement, finishing, curing etc.,complete and as directed by TWAD Board Officers. - 3.40 M HT

5

-

-

... More
Provision for supply & fixing of MS ladder including Painting etc. complete. - 2 M HT

1

-

-

... More
Exterior Emulsion paint Two coats with good quality of approved Emulsion paint including cost of all materials to site and all labour charges for mixing applying and proper curring etc., Complete as per Standard Specifications for 10 sqm

1647

-

-

... More
White washing two coats for walls inside with fine screened shell lime complying with standard specification and as directed by the Departmental Officers.

135.06

-

-

... More
Labour for filling the coarse sand passing through a sieve of 10 meshes to 2.5 cm and retained in 20 meshes to 2.5 cm well washed and cleaned to be free from impurities including stacking.Plugging the bottom of the well with coarse sand of approved sizes and grade as directed by the Board officers.

14.31

-

-

... More
Refilling the foundation with excavated Soil (other than sand) in layers of not more than 15cm thick, watering, well ramming, consolidating, complying with standard specification and as directed by TWAD Board Officers.

1007

-

-

... More
Labour charges for Painting TWAD Board Emblem in accordance with the size and specifications as approved by the Board on the Service Reservoirs including cost of all consumables, one coat of base paint, scaffolding charges including painting NRDWPLogoon theService Reservoirs.

10

-

-

... More
Supply, delivery and fixing of pipes for OHT connections including civil works 150MM CI PIPEfor inlet,outlet,overflow and 100mm CI pipe for scour including construction of valve pit(vide separate estimate)

1

-

-

... More
Oht 2.50LL - 1 No , Oht 3.00LL - 1 No

1

-

-

... More
Inlet- 150mm CI Pipe (Length - 20.60m , Kg- 11.01 Kg )

2

-

-

... More
Outlet - 150mm CI Pipe (Length - 17.55m , Kg- 9.65 Kg )

2

-

-

... More
Scour- 100mm CI Pipe (Length - 16.95 m , Kg- 5.73 Kg )

2

-

-

... More
Overflow - 100mm CI Pipe (Length - 20.2 m , Kg- 6.83Kg )

2

-

-

... More
Providing pipe connection work for SR .Rate including supply & laying of pipes, specials and valves etc.,complete and as directed by Departmental Board Officers.For Sump

1

-

-

... More
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation.

1

-

-

... More
1500 lpm against a total head of 70m

2

-

-

... More
900 lpm against a total head of 20m

2

-

-

... More
900 lpm against a total head of 20m

2

-

-

... More
Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button. - 40HP or SuitableFor sump

2

-

-

... More
Supply and delivery of Star-Delta starter where panel boards are available confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature Circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). -

1

-

-

... More
7.5 HP or Suitable

2

-

-

... More
10 HP or Suitable

2

-

-

... More
Supply, delivery, erection, testing and commissioning of following sizes of power shunt capacitor for power factor improvement, suitable to operate on 415V, 3Ph,50Hz A/C supply, on suitable angle iron frame-works (37.5 mm x 37.5 mm x 6.24mm ) at a height of 0.25m from the ground, including earthing and incidental civil works etc., complete.

1

-

-

... More
12 kVAR

2

-

-

... More
3 kVAR

4

-

-

... More
Supplying and fixing of LT/LTCT METERING BOX as per IE rules and TANGEDCO norms per 75HP/56 KW (which includes LT meter panel board, 6 Nos. suitable fuse carriers

1

-

-

... More
160 Amps

1

-

-

... More
Supplying and fixing of 200A TPN Switch Disconnector Fuse Units in Sheet Steel Enclosure with HRC fuses Double Break

1

-

-

... More
160 Amps

1

-

-

... More
Supply, delivery, erection, testing and commiossioning of floor mounted M.V.panel(SCADA Compatible) with aluminium bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters,ammeters with selectorswitches, energy meter,phase indicating lamps, Mechanical Interlock, etc., complete with incidental civil works and comprising of following and as per specifications & drawings; The panel shall be powder coated as per specification.

1

-

-

... More
Capacity of M.V. Panel - 160 Amps

1

-

-

... More
Supplying and laying following LTUG cables in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed. 2 Runs Each

1

-

-

... More
DO - 3 ½ core 95 sq.mm. for PS(Incomer)

30

-

-

... More
DO - 3.5 core 25 sq.mm - Panel to Starter (PS) - Sump

20

-

-

... More
DO - 3 core 25 sq.mm - Starter to Motor - Sump

30

-

-

... More
DO - 4 core 4 sq.mm - Panel to Starter (IFW)

40

-

-

... More
DO - 3 core 4 sq.mm - Starter to Motor

600

-

-

... More
DO - 4 core 4 sq.mm. for Aux.supply

50

-

-

... More
Supplying and fixing of cable gland and termination with Aluminium cable lugs for following PVC UG cable and with earth connection

1

-

-

... More
DO - 3 ½ core 95 sq.mm.

5

-

-

... More
DO - 3 ½ core 25 sq.mm.

3

-

-

... More
DO - 3 core 25 sq.mm

5

-

-

... More
DO - 3 core 4 sq.mm

21

-

-

... More
DO - 4 core 4 sq.mm

5

-

-

... More
Supply, delivery and erection of Three Phase 4 way 32 Amps, 10kA LDB with the following:1 No of 40 A FP isolator for incoming supply3 Nos. of 16A, DP RCCB3 Nos. of 16A, SP MCB1 No of 16A, DP MCB3 Nos of 6A, DP MCBin sheet steel enclosure fitted with busbars and neutral links and suitable angle iron frame works with provision for earthing etc. complete.

1

-

-

... More
Run of 2 of 2.5 sq mm PVC unsheathed copper single core cable in PVC pipe for mains with continuous earth connection by 14 SWG wire From the MCB DB to the Switch boards in office, store,and 16A power socket.

100

-

-

... More
Wiring with 2.5 sq mm PVC insulated single core copper cables of 650 V Grade on suitable rigid PVC pipe on wall and ceiling with PVC accessories, with MS switch box covered with 3 mm thick hylam sheet with continous earth wire connection of 14 SWG TC wire.

1

-

-

... More
Light points

6

-

-

... More
Fan Points

1

-

-

... More
Supply and installation of 240 V - 1 x 20 W LED TL fitting box type with enamelled reflector complete with all accessories - choke, starter, tube, etc. suitable for wall mounting or roof mounting on conduit tube.

4

-

-

... More
Supplying and fixing of 18" sweep AC exhaust fan complete including providing necessary opening in the wall.

1

-

-

... More
Supply and fixing of 48" sweep AC ceiling fan complete with regulator with lm down rod (stem pipe) including supplying and fixing of fan clamp with side plates and cross arms

1

-

-

... More
Earthing as per ISI specifications with necessary masonary work.

1

-

-

... More
Supply and connection of earthing conductor including two coats of approved painting and laying between earth pit and equipment.

1

-

-

... More
40 x 6 mm GI Flat

40

-

-

... More
25 x 6 mm GI Flat

20

-

-

... More
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.

1

-

-

... More
Above 30HP to 40HP

2

-

-

... More
5HP to 10HP

4

-

-

... More
Supply, conveying and fixing CI/DI specials as per the latest revision of IS 1538 including with ISI markings on it including earthwork excavation, lowering into the trenches, aligning, refilling the trenches with excavated soil, watering and ramming to consolidation, etc.

1

-

-

... More
150 x 200mm Taper

6

-

-

... More
200 x 200mm Flange tee

6

-

-

... More
200 mm dia CI blank flange

3

-

-

... More
Supply, conveying and fixing following CI pipes as per latest revision of IS 1536 with ISI markings on it excluding earthwork excavation

1

-

-

... More
200 mm D/F C.I cut pipe - 0.5m long

10

-

-

... More
200 mm D/F C.I cut pipe - 1.0m long

12

-

-

... More
Drilling of borewells of size 6” to 8” dia. in sedimentary formation using hand boresets including insertion of casing pipes and removal of casing pipes etc., including collection of samples as directed by the Departmental Officers..

324

-

-

... More
Supply of the following UPVC Pipe 6 KSc Pipe as per IS specifications 4985/2000.160 MM PIPE

324

-

-

... More
Supply of the following UPVC Pipe 6 KSc Pipe as per IS specifications 4985/2000.50 MM PIPE

400

-

-

... More
Supply and Laying of 400 mm Dia RCC NON PRESSURE SPUN PIPE AS per IS 458/2003

135

-

-

... More
Supply and delivery of RUBBER GASKETS AS PER IS 5382/1985 (Reaffirmed 1998)

54

-

-

... More
Earth work excavation and depositing on bank withinitial lead of 10 m and lift of 2 M in narrow trencheshaving bed width 1.25m & below for laying of pipes forwater supply and sewerage works in the following typeof soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales,murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B

1

-

-

... More
Pumping Main - HDPE PN8

1

-

-

... More
110 mm HDPE PE100PN8

425

-

-

... More
160 mm HDPE PE100PN8

541

-

-

... More
200 mm HDPE PE100PN8

1790

-

-

... More
Distribution System - HDPE PN6

1

-

-

... More
90 mm HDPE PE100PN6

8261

-

-

... More
110 mm HDPE PE100PN6

670

-

-

... More
125 mm HDPE PE100PN6

533

-

-

... More
140 mm HDPE PE100PN6

425

-

-

... More
160 mm HDPE PE100PN6

178

-

-

... More
180 mm HDPE PE100PN6

289

-

-

... More
200 mm HDPE PE100PN6

93

-

-

... More
225 mm HDPE PE100PN6

308

-

-

... More
250 mm HDPE PE100PN6

878

-

-

... More
280 mm HDPE PE100PN6

20

-

-

... More
Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016

1

-

-

... More
Pumping Main - HDPE PN8

1

-

-

... More
110 mm HDPE PE100PN8

425

-

-

... More
160 mm HDPE PE100PN8

541

-

-

... More
200 mm HDPE PE100PN8

1790

-

-

... More
Distribution System - HDPE PN6

1

-

-

... More
90 mm HDPE PE100PN6

8261

-

-

... More
110 mm HDPE PE100PN6

670

-

-

... More
125 mm HDPE PE100PN6

533

-

-

... More
140 mm HDPE PE100PN6

425

-

-

... More
160 mm HDPE PE100PN6

178

-

-

... More
180 mm HDPE PE100PN6

289

-

-

... More
200 mm HDPE PE100PN6

93

-

-

... More
225 mm HDPE PE100PN6

308

-

-

... More
250 mm HDPE PE100PN6

878

-

-

... More
280 mm HDPE PE100PN6

20

-

-

... More
Supplying and conveying of following sizes of DI Class K7 flanged pipes Pipes to site, confirming to specification as per IS:8329-2000 for standard length including cost of pipes, testing charges at factory, labour charges for loading, unloading and stacking at site etc..

1

-

-

... More
150mm Dia - Connecting main DI/DF

47

-

-

... More
DI Specials Per IS 9523/2000 Bund crossing Pipe arrangements for transmission Main.

1

-

-

... More
150mm Duck foot Bend 90deg

216

-

-

... More
150mm Bends 90 deg

168

-

-

... More
150 mm DI K7 flanged Pipes 4m

8

-

-

... More
150 mm DI K7 flanged Pipes 2m

6

-

-

... More
Lowering HDPE PE100 PN6 & PN8 pipes and specials to trench and laying to proper grade and alignment and as directed by the Departmental Engineer

1

-

-

... More
Pumping Main - HDPE PN8

1

-

-

... More
110 mm HDPE PE100PN8

425

-

-

... More
160 mm HDPE PE100PN8

541

-

-

... More
200 mm HDPE PE100PN8

1790

-

-

... More
Distribution System - HDPE PN6

1

-

-

... More
90 mm HDPE PE100PN6

8261

-

-

... More
110 mm HDPE PE100PN6

670

-

-

... More
125 mm HDPE PE100PN6

533

-

-

... More
140 mm HDPE PE100PN6

425

-

-

... More
160 mm HDPE PE100PN6

178

-

-

... More
180 mm HDPE PE100PN6

289

-

-

... More
200 mm HDPE PE100PN6

93

-

-

... More
225 mm HDPE PE100PN6

308

-

-

... More
250 mm HDPE PE100PN6

878

-

-

... More
280 mm HDPE PE100PN6

20

-

-

... More
Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers.

1

-

-

... More
150mm diameter

225

-

-

... More
Lowering RCC pipes and specials into the trenches and laying to proper grade and alignment

1

-

-

... More
400 mm diameter

135

-

-

... More
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Departmental Engineer

1

-

-

... More
Pumping Main - HDPE PN8

1

-

-

... More
110 mm HDPE PE100PN8

71

-

-

... More
160 mm HDPE PE100PN8

90

-

-

... More
200 mm HDPE PE100PN8

298

-

-

... More
Distribution System - HDPE PN6

1

-

-

... More
90 mm HDPE PE100PN6

165

-

-

... More
110 mm HDPE PE100PN6

112

-

-

... More
125 mm HDPE PE100PN6

89

-

-

... More
140 mm HDPE PE100PN6

71

-

-

... More
160 mm HDPE PE100PN6

30

-

-

... More
180 mm HDPE PE100PN6

48

-

-

... More
200 mm HDPE PE100PN6

16

-

-

... More
225 mm HDPE PE100PN6

51

-

-

... More
250 mm HDPE PE100PN6

146

-

-

... More
280 mm HDPE PE100PN6

3

-

-

... More
Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS638(1979) and M.S. bolts and nuts of IS 1364-1(2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labourcharges etc., complete.

1

-

-

... More
150mm diameter

51

-

-

... More
Jointing RCC pipes with cement using necessary collars including the cost of jointing materials and Jointing Rubber gaskets as per IS 5382/1985 (Reaffirmed 1998).

1

-

-

... More
400 mm diameter

54

-

-

... More
Cutting the HDPE pipes true to axis and finishing the ends complete.

1

-

-

... More
Pumping Main - HDPE PN8

1

-

-

... More
110 mm HDPE PE100PN8

11

-

-

... More
160 mm HDPE PE100PN8

14

-

-

... More
200 mm HDPE PE100PN8

45

-

-

... More
Distribution System - HDPE PN6

1

-

-

... More
90 mm HDPE PE100PN6

207

-

-

... More
110 mm HDPE PE100PN6

17

-

-

... More
125 mm HDPE PE100PN6

13

-

-

... More
140 mm HDPE PE100PN6

11

-

-

... More
160 mm HDPE PE100PN6

4

-

-

... More
180 mm HDPE PE100PN6

7

-

-

... More
200 mm HDPE PE100PN6

2

-

-

... More
225 mm HDPE PE100PN6

8

-

-

... More
250 mm HDPE PE100PN6

22

-

-

... More
280 mm HDPE PE100PN6

1

-

-

... More
Testing of DI/HDPE pipes with hydraulic testing equipment by filling with water ( including cost of water ) and testing to recommended pressure in convenient strectches and attending the burst if any occurred during the test , excluding the cost of pipes , including other incidental and operational charges etc . complete for following diameters of pipes

1

-

-

... More
Pumping Main - HDPE PN8

1

-

-

... More
110 mm HDPE PE100PN8

425

-

-

... More
160 mm HDPE PE100PN8

541

-

-

... More
200 mm HDPE PE100PN8

1790

-

-

... More
Distribution System - HDPE PN6

1

-

-

... More
90 mm HDPE PE100PN6

8261

-

-

... More
110 mm HDPE PE100PN6

670

-

-

... More
125 mm HDPE PE100PN6

533

-

-

... More
140 mm HDPE PE100PN6

425

-

-

... More
160 mm HDPE PE100PN6

178

-

-

... More
180 mm HDPE PE100PN6

289

-

-

... More
200 mm HDPE PE100PN6

93

-

-

... More
225 mm HDPE PE100PN6

308

-

-

... More
250 mm HDPE PE100PN6

878

-

-

... More
280 mm HDPE PE100PN6

20

-

-

... More
Testing of DI pipes with hydraulic testing equipment by filling with water (including cost of water Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occurred during the test, excluding the cost of pipes, including other incidental and operational charges etc. complete and as directed by Departmental Officer for the following diametre of pipes

1

-

-

... More
150mm diameter

225

-

-

... More
Barricading work (Where there is less traffic and lines are in narrow width of town panchayat area, busy streets like Market, Bus-stand and in the Highways etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia. and 1.80m height) vertical with horizontal poles in two rows, painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including supplying, delivery and fixing of GI sheet (0.90m x 0.8mm thick) in the horizontal poles and fixing 75mm dia. reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further useetc., complete and as directed by Departmental Engineers.

11528.8

-

-

... More
Refilling with excavated sand complying with standard specification for filling in foundation and basement

1

-

-

... More
Pumping Main - HDPE PN8

1

-

-

... More
110 mm HDPE PE100PN8

425

-

-

... More
160 mm HDPE PE100PN8

541

-

-

... More
200 mm HDPE PE100PN8

1790

-

-

... More
Distribution System - HDPE PN6

1

-

-

... More
90 mm HDPE PE100PN6

8261

-

-

... More
110 mm HDPE PE100PN6

670

-

-

... More
125 mm HDPE PE100PN6

533

-

-

... More
140 mm HDPE PE100PN6

425

-

-

... More
160 mm HDPE PE100PN6

178

-

-

... More
180 mm HDPE PE100PN6

289

-

-

... More
200 mm HDPE PE100PN6

93

-

-

... More
225 mm HDPE PE100PN6

308

-

-

... More
250 mm HDPE PE100PN6

878

-

-

... More
280 mm HDPE PE100PN6

20

-

-

... More
Labour for cutting open road for laying water mains or sewer

1

-

-

... More
BT Cutting

284.66

-

-

... More
CC Cutting

783.87

-

-

... More
Deduct

1068.54

-

-

... More
Plain Cement Concrete 1:4:8 Mix (one part cement, Four part sand and Eight part of aggrigate) using 40mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.

635.6

-

-

... More
Plain Cement Concrete 1:2:4 Mix (one part cement, two part sand and four part of aggrigate) using 20mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.

798.49

-

-

... More
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.6 with ISI mark, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes

1

-

-

... More
Connecting main - DI/DF K7

1

-

-

... More
100mm Dia

2

-

-

... More
Pumping Main - HDPE PN8

1

-

-

... More
80mm Dia

1

-

-

... More
100mm Dia

2

-

-

... More
Distribution System - HDPE PN6

1

-

-

... More
80mm Dia

11

-

-

... More
100mm Dia

4

-

-

... More
150mm Dia

4

-

-

... More
200mm Dia

1

-

-

... More
Electrical

1

-

-

... More
200mm Dia

4

-

-

... More
Supplying, delivery and installation at site, conveying and fixing the CI D/F Reflux valves as per IS 5312/Part I /84 with Bye-pass arrangements with ISI marking including loading, transportation charges and stacking etc complete as per specifications

1

-

-

... More
150mm NRV

4

-

-

... More
200mm NRV

2

-

-

... More
Supplying, delivery and installation at site, conveying and fixing the CI double air valve as per IS14845/2000 with ISI marking including loading, transportation charges and stacking etc complete as per specifications

1

-

-

... More
50mm Double Air valve

3

-

-

... More
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type , microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure,manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils,electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accredited lab to be furnished

1

-

-

... More
150 mm Diameter

1

-

-

... More
SI NO12.14.6 DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.”Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing

1

-

-

... More
100mm Diameter

1

-

-

... More
Constructing masonry chamber of inside dimensions as mentioned below with Class 1 designation, brick work in cement mortar 1:5 (1 cement : 5 coarse sand) for sluice valve, with CI Surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep.

1

-

-

... More
100mm diameter - (0.90x0.75x1.20)

2

-

-

... More
Construction of chamber for sluice valve & scour valve using second class chamber bricks in cement mortar 1:4 and necessary plastering with cement mortar 1:3 for 12 mm both inside and outside, precast concrete covers as per drawing , as per IS specifications and as directed by the engineers for the following sizes in metres,as per drawing.

1

-

-

... More
Valve pit of size -(1.0 m x 1.0 m x 1.5 m)

14

-

-

... More
HSC Connection - 20 mm - Providing House service connection with MDPE 20mm pipe (supply, lowering, jointing & testing), electrofusion tapping saddle PE 80 blue, PN 12.5 with female threaded metal insert of SS 304, Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded to suit the corresponding bore sizes of 15mm dia size (1/2"), Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304, Poly propylene 90 Degree Compression elbow with compression joint at both ends, Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 and protection box of size 20cm x 30cm for fixing of without Water Meter all as per standard including road cutting, replacement of utilities providing house service connection, refilling, retoration of roads/drains testing etc complete with materials and specification as instructed by department officers

470

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.