Directorate Of Town Panchayats Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Directorate Of Town Panchayats - DTP Tender
Civil And Construction
Building Construction
Eprocure
Opening Date14 Aug 2024
Closing Date22 Aug 2024
Tender Amount₹ 1,20,00,000
Costs
EMD
₹ 1,20,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
School Building-new Construction-6th Sfc-2024-2025
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DTP_472257_1Bid Award Id
ViewTender No
229/2024/A1Tender Authority
Directorate Of Town Panchayats ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Filling in basement with excavated soil (other than sand) in layers of not more than 15cm thick, watered rammed and well consolidated etc completed , complying with standard specifications.
132.66
-
-
Supplying and filling in basement with Garvel in layers of not more than 15cm.thick well rammed watered and consolidated etc., complete complying with standard specification.
31.79
-
-
Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9" X 43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT
31.79
-
-
For Foundation & Basement
1
-
-
For Super Structure in Ground Floor
66.33
-
-
For Super Structure in First Floor
31.79
-
-
For Super Structure in Second Floor
1
-
-
Damp proof course in cement mortar 1:4 (One cement and four sand) 12mm thick mixed with water proofing compound conforming to I.S. at 2% by weight of cement used., complete complying with standard specifications.
63.58
-
-
Supplying and erecting Steel shuttering including necessary supports for Plane Surfaces in foundation and basement for reinforced cement concrete works such column footings, plinth beam, Grade beam, Stair Case steps, bed blocks etc., which requires only nominal strutting using stiffened with mild steel sheets of suitable size 90cm x60cm and BG 10 stiffened with mild steel angles of size mm of 25mm x 25mm x 3 mm for boardinglaid over silver oak joists of size 10cm x 6.50 cm spaced at about 60 cm centre to centre and supported by the casurina props of 10 cm to 13 cm dia paced at 75 cm centre to centre or at suitable intervals etc., complete complying with standard specifications. -The payment for centering shall be made only after the concrete laid. The retrieved materials should be taken back by the contractor-.
6
-
-
Supplying and Erecting, Centering for sides and soffits including supports and strutting upto 3.29m height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90cm X 60cm and BG 10 gauge stiffened with welded mild steel angles of size 25mm X 25mm X 3mm for boarding laid over silver oak joists of size 10cm X 6.50cm spaced at about 90cm centre to centre and supported by Casurina props of 10cm to 13cm dia spaced at not less than 75cm centre to centre at sutiable intervals etc., complete in all floors for complying with standard specifications. and as directed. The payment for centering shall be made only after the concrete laid. The retrieved materials should be taken back by the contractor.-
1
-
-
Plane surfaces such as RCC floor slab, roof slab, rectangular, square, Tee or Ell beam, lintels, bed blocks staircase waist slab, landing slab, landing beams, portico beams, portico slab etc.,
13.56
-
-
Plane surface such as RCC square or rectangular columns, top and bottom slab of sunshade, boxing sill slabs, etc.,
22.61
-
-
Providing and laying in position, standardised concrete Mix M-2o Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers
10.26
-
-
For Foundation & Basement
1
-
-
For Super Structure in Ground Floor
1
-
-
For Super Structure in First Floor
198.95
-
-
For Super Structure in Second Floor
42.2
-
-
Cement Concrete 1:8:16 (One Cement, Three crushed stone sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete.
42.48
-
-
For Super Structure in Second Floor
10.8
-
-
Supplying, fabricating and placing in position of steel reinforcement using mild steel/ribbed tor steel bars for all RCC works as per the design given including cost of steel and binding wire in all floors complying with standard specifications.
17.75
-
-
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
74
-
-
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
95.22
-
-
Brick Partition Walls using II class ground moulded chamber bricks of size 9"X43/8"X 23/4" in C.M 1:3 (One part of Cement and Three part of Crushed Stone Sand (M- Sand)) using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification - 10 sqm
40.84
-
-
In Ground Floor 10.80 cm thick
159.32
-
-
In First Floor 10.80 cm thick
3.2
-
-
Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.25mm thick
12
-
-
Supplying and fixing in position best approved ISI quality PVC Rainwater Downfall pipes of 110mm diameter having working pressure of 4kg/cm2 including cost of PVC pipe, with necessary shoes, bends, nails, teakwood plugs, screws etc, and fixing of cast iron gratings of required dia metre and special clamps at junction of parapet and the RCC roof slab including finshing neatly etc., complete. The rate shall be inclusive of cost of removable cast iron gratings. The size of teak wood plugs to be used shall be 150mm x 25mm in front and 200mm x 75mm in rear and all other sides to a depth of 100mm. The PVC pipe shall be fixed with teakwood plugs by means of "U" Clamps using brass screws. Special types of "U" clamp at the centre of the pipeline shall be fixed in addition to those for more than 3 metre pipe length complying with standard specifications.
1
-
-
Paving the floor with pre-polished Concrete Anti-Skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg/sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.
4
-
-
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
1
-
-
Manufacturing, supplying and fixing in position of STEEL WINDOWS with the following specifications. Outer frames of windows made of ‘Z’ section F7D of size 33 x 25 x 3mm at 1.419 Kg / m and mullion ‘J’ Section (F4B) of size 46 x 25 x 3mm at 2.28 Kg / m and shutter section of made of F7D of 33 x 25 x 3mm at 1.419 Kg / m as specified in IS 7452 / 1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18 x 5mm MS Flat at 0.70 Kg / m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS Flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly.
4
-
-
Four Leaves
2
-
-
Manufacturing supplying and fixing of MILD STEEL DOOR made out of 50 x 50 x 6 mm M.S angle for outer frame,35 X 35 X 5mm M.S.Angle for outer frame of shutter. The entire shutter area shall be covered with CRC sheets (18 G) with 5Nos, of stiffners using M.S.Flats of size 25 X 6mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash butt welding or any other suitable method. Provision towards 3Nos, of Hinges incase of single shutters / 6Nos,of Hinges incase of Double shutters of 125 X 31 X 1.25mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop 1No. The frame shall be provided with 6Nos,of Hold fast of 200mm length using 50 X 6mm M.S.Flat. The entire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemental officers.
1
-
-
Double leaf
120
-
-
Single leaf
360
-
-
Supplying and fixing of Mild steel window Double Leaves cum emergency door for emrgency exist with top window position covered with MS sheet using section of 32x29x5mm thick of door frame. The shutter shall be made out of FX6 section of size 29x29x5mm with necessary stiffners shall be 25x25x5mm outer frame covered with MS sheet shutter will be fixed to the frame of means hinges with necessary towerbolt, aldrops etc., bottom 1/3rd of door covered with Hinges of MS sheet shall be welded upto sill level of outer frame. The emergency door will given one coat of zinc ornamental yellow primer etc., complete complying with standard specification.
1
-
-
Painting two coats over new iron works such as steel doors, windows, ventilators, window bar balustrades etc., with best approved first quality synthetic enamel paint of approved colour over the existing red oxide priming coat in all floors. The rate is inclusive of all materials, brushes and scaffolding charges etc., complete complying with standard specification -Paint should be got approved by the Executive Engineer before use on work-.
4
-
-
Supplying and fixing in position steel balustrade using 20mm size square bars at 15cm centre to centre and two balusters in single step centrally located and top shall be welded to 40mm X 6mm mild steel flat to fix the handrail having a groove 40 x 6mm and bottom fixed in the step concrete fixing M.S. Flats of size 50mm X 6mm to be provided at the centre of the balustrade connecting all the square bars to the entire length of the balustrade and the square bars well anchord in the floor / step concrete through fish tail splay at bottom including painting the steel member of the balustrade with one coat of red oxide primer etc., complete complying with standard specifications.
1
-
-
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing,
conveyance, electrical charges, etc.complete
8
-
-
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
2
-
-
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
2
-
-
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
1
-
-
Manufacturing, supplying and fixing of Entrance steel door Single leaf coverd with the following specification. M.S angles of a size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32x6mm M.S. flat is provided at required intervals in the shutter frames 18 gauge C.R. sheet is laid as panel in the shutter and welded intact for 1/3 bottom portion of the shutter. M.S. flat 18x5mm is welded over the 32x6mm M.S. flat sand witching the CR sheet in between. Additional stiffener with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter.
2
-
-
Supplying and Fixing M.S grill to opening corridor sides, ladder Entrance gate and Name board angles etc., Using necessary M.S flat for inner members and outer members which should be fixed to window members frames as directed by departmental officers inclusive of cost of providing one coat of best quality red oxide primer. -The design of M.S. grill should be got approved from departmental officers before use on works.-
4
-
-
Supplying and fixing colour galvanum sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.
1
-
-
Supplying and Fixing of Aluminium Dye Cast letters of following size to suit the Architectural elevation drawings given for the including Cost ,conveyance and all other materials and Labours involved etc., complete and as directed by the Department Officers
4
-
-
Aluminium Dyecast letters 25cm size
SOR 23-24, UC-M-0694
2
-
-
Emblem SOR23-24, UC- M-0703
6
-
-
Painting two coats of newly plastered wall surface with ready mixed Cement paint of first quality and of approved colour over a priming coat including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required etc., complete complying with standard specification.
2
-
-
Providing Polymer Coating (Water Proof Coating) for sunken Portion of toilet with following specification and the surface shall be cleaned to remove all dust, foreign, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred throughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.
Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. SOR 23-24, UC- M-0625
2
-
-
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitablePVC rigid pipe on wall and ceiling with PVC accessories with TW switch box inflush with wall with 5A FT switch covered with hylum sheet of 3mm thick with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / fan point (for electronic regulator)
4
-
-
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box for 5A 3 pin non interlocking flush type CS plug wfth painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open plug point SD 11
2
-
-
Supply and Run of 2x4 sq.mm(84/0.3) PVC insulated Sc unsheathed Cu.Conductor of 1100V grade in 25mm dia G.I pipe (Bclass) suitable bend at both ends with necessary angle iron up right and end supports for mains. SD 365
1
-
-
Supply and Run of 2x4 sq.mm(84/0.3) PVC insulated Sc unsheathed Cu.Conductor of 1100V on 7/20 Gibearer wire for service connection mains.SD 66
1
-
-
Supply and Fixing of 20W LED Tube Light for T8 Fitting (Single Side) including all labour Charges M-1278
1
-
-
Supply and Fixing of AC Ceiling Fan complete 1200mm (48") Sweep with 300mm Down Rod (without Regulator) (Higher End) SD 108
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements