Directorate Of Town Panchayats Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Directorate Of Town Panchayats Tender

Works
Finance And Insurance Sectors
Eprocure
Opening Date24 Jan 2024
Closing Date29 Jan 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

15th Finance Commission - (tied And Un Tied) 1nd And Installment 2023-24 In Needamangalam Town Panchayat Thiruvarur District

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Brickwork in Cement Mortor 1:5 (One cement five M-sand) mix using country burnt bricks of standard size 8 3/4"x4 1/4"x2 1/4" including cost and conveyance of all materials and labour etc complete as per standard specification

3

-

-

... More
Cement concrete 1:2:4 using the following sizes of hard broken stone jelly for RCC pre-cast slabs of 75mm thickness excluding cost of reinforcement grill in position but including moulding finishing, curing, and fixing them in position etc., complete complying with standard specification.

1

-

-

... More
Supplying and delivery of Brick jelly all labour charges and all other incidential charges etc,. complete as per Standard Specification

1

-

-

... More
Supply of the following casing pipes of ISI approved quality with wall thickness not less than 7.5mm to 8.5mm with PVC couplers and cement Paste etc. Complete and including packing the annular space with pebbles quality and size of pebbles and the PVC pipe should be approved by the departmental officer.

3

-

-

... More
Plastering with cement mortar 1:5 ;12 mm thick in all floors etc., complete complying with standard specifications (S.I.306)

13

-

-

... More
Painting the newly plastered wall surface with two coats of Emulsion paint of approved quality and colour over one coat of cement primer including cleaning the surface etc complete as per standard specification.

5

-

-

... More
Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 150mm dia and then enlarging to 300mm dia bore by direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling benonite and water required for drilling at site. Site will be shown by the Departmental officers including construction of mud pit..upto 60m depth ending below ground level Upto 60 mt. Depth ending below ground level

39

-

-

... More
Reaming 200/350mm dia pilot bore to 300mm dia bore as directed by the Departmental officers. Upto 60 mt. Depth ending below ground level

39

-

-

... More
Supply of the following casing pipes of ISI approved quality with wall thickness not less than 7.5mm to 8.5mm with PVC couplers and cement Paste etc. Complete and including packing the annular space with pebbles quality and size of pebbles and the PVC pipe should be approved by the departmental officer. 150mm dia OD PVC Plain casing Pipe (CS)

24

-

-

... More
150mm dia OD PVC slot casing Pipe (RS)

15

-

-

... More
150mm dia OD PVC end cap

1

-

-

... More
Labour charges for inserting150 mm dia OD PVC casing pipes assembly. (with slots and without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste including supplying and packing of pebbles in anular spaces as approved by the Asst.Exe.Engineer.

39

-

-

... More
Charges for developing the borewell with air compressor of 300CFM. Capacity (minimum 8 hours ) including transportation labour and fuel charges for compressor as directed by the Departmental Officers and conducting yield test by 'V' notch methods.

4

-

-

... More
supply and delivery of 1HP single phase Submersible pumpset of duty condition 15lpm x 100 m as per IS 8034 without panel board etc complete as per standard specification.

1

-

-

... More
Supply of single phase Pannel board suitable for 2HP with two level guard and auto start etc complete as per standard specification.

1

-

-

... More
Supplying and delivery of 2.5Sq.mm of PVC insulated and sheathed 3 core flat type copper cable confirming to IS694/ 1990 etc complete as per standard specification.

18

-

-

... More
Labour charges for the errection of 1HP submersible pumpset in the Borewell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth walls errection clamps pressure gauges up to the exterior wall of pumping room and errection of panel board consisting of DPICN switches starter volt meter ammeter, Three Pilot ( Indicating ) lamps capacitor single phasing preventer water level guard and laying and jointing the cable s and twin earthing as per IE rules etc complete and testing to the pumpset and trial run for 10 Days.

1

-

-

... More
Supply and run of 2 of 1.5 sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade on heavrar of 7/20 Gi wire for service conuction SD 65

20

-

-

... More
Supply and fixing of 100 Amps DPIC Switch of 500 V with metal clad with fuse and neutral (Side Handle) on suitable TW Board , with earth connection only SD 144

1

-

-

... More
Earthing as per P.W.D standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work SD 234

1

-

-

... More
Supply and fixing of TNEB meter Board suitable for 32A Single Phase service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1" x 1/8" Copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit. SD 125

1

-

-

... More
Supply and delivery and fixing of HDPE tank 1000 litres capacity as per IS 12701/ 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges as directed by departmetal officers.

1

-

-

... More
Supply and delivery and fixing of M.S Kisok of size 0.75mx0.45mx0.75m made up of m.s angle size 50mmx50mmx4mm allround covered with 16 gauge M.S sheet and kisok door made up of this M.S plate of size 25mmx3mm Including cutting ,welding grinding locking arrangements

1

-

-

... More
Supplying and fixing of pvc pipe and accessories ISI make including cutting and threading cost and conveyance of all charges etc complete as per standard specification. 50mm upvc pipe

18

-

-

... More
50mm pvc Elbow

2

-

-

... More
Earthwork excavation for foundation in all soils and sub soils in hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders and to full depth as may be directed,except in hard rock,requiring blasting including shoring and shuttering and bailing out of water wherever necessary,refilling the sides of foundation with excavated earth or sand in layer of not more than 15cm thick.well rammed and consolidated and depositing on bank with initial lead and lift of 10m & initial lift of 2m and depositing the surplusr earth within the compound in places shown by the departmental officers with iniital lead and lifts,clearing and levelling the site etc., complete as per SS20B and as directed by departmental Engineers(TNBP No.17,23,24). - 1 M3 90mm PVC Pipe

330

-

-

... More
Supply and Delivery of PVC Portable water supply pipe K6 as per IS 8329/2000 etc. Complete as per standard specifications. 90mm PVC Pipe

330

-

-

... More
Supply and Delivery of PVC Pipes and Specials etc. Complete as per standard specifications. 90mm PVC Coupler

5

-

-

... More
90mm PVC Bend

5

-

-

... More
90mm PVC Tee

3

-

-

... More
90mm PVC End Cap

2

-

-

... More
Conveying the PVC pipes and specials to trench, lowering into the trenches, laying to proper grade and alignment, jointing with PVC coupler and specials fixing with neat cement paste and testing to the required pressure as per IS including conveyance of water from 1Km lead for filling during testing. 90mm PVC Pipe

330

-

-

... More
Refilling with excavated sand complying with standard specification for filling in foundation and basement. etc ., complete complying with standard specifications. 90mm PVC Pipe

330

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.