Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Department Of Atomic Energy - DAE Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Nov 2024
Closing Date24 Dec 2024
Tender Amount₹ 49,00,000
Costs
EMD
₹ 98,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Maintenance Of Electrical Installations In Residential And Non-residential Buildings In Anupuram Township For The Year 2025-2026.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GSO_837260_1Tender No
GSO/CTC/ESD/129/2024Tender Authority
Department Of Atomic Energy ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
General Specification and requirements for Electrical Works Section VI
General Specification and requirements for Electrical Works MAINTENANCE Section VI MNC
Annexure 2 to 4 to be signed and uploaded
Form of Agreement to be signed and uploaded
Technical Bid and Forms ACDFGH to be filled and uploaded
BOQ Items
40-63Amps, FP MCB (TYPE-C)
10
-
-
125 Amps FP MCB (Type-C)
2
-
-
RCCB DP 25A sensitivity 30mA, TYPE Hpi
15
-
-
RCCB DP 40A sensitivity 30mA, TYPE Hpi
30
-
-
RCCB FP 40A sensitivity 30mA, TYPE AC
8
-
-
RCCB FP 63A, 300 mA sensitivity Type AC
2
-
-
Supply, replacement and testing of following Switches /Bell push / Sockets / Plug top etc. as per the detailed specification and as directed by Engineer-in-charge.(Refer Sec VI (MNC), Clause No.5).
-
-
-
1 No 10A One Way Switch on modular plate and termination of wires to the switches.
800
-
-
1 No 10A Two Way Switch on modular plate and termination of wires to the switches
80
-
-
1 No 10A Bell Push Switch on modular plate and termination of wires to the switches
80
-
-
1 No 16A One Way Switch on modular plate and termination of wires to the switches.
300
-
-
1 No 16A Two Way Switch on modular plate and termination of wires to the switches.
30
-
-
1 No 6A 3 Pin Shuttered Type Socket heavy duty on modular plate and termination of wires to the switches.
200
-
-
1 No 6/16A 3 Pin combined shuttered type Socket heavy duty on modular plate and termination of wires to the switches
200
-
-
1 No 20 Amp Motor starter Switch on modular plate and termination of wires to the switches.
5
-
-
1 No 16A 3Pin heavy duty plug top with indicator and termination of wires to the switches
5
-
-
1 Modular dummy plate
50
-
-
One/Two module Modular front cover plate
80
-
-
3 Module Modular front cover plate
300
-
-
4 Module Modular front cover plate
150
-
-
6 Module Modular front cover plate
30
-
-
8 Module Modular front cover plate
5
-
-
12 Module Modular front cover plate
10
-
-
1No Geyser Indicator and termination of wires to the switches.
15
-
-
1No 20 Amps SP C MINI MCB suitable in modular plate and termination of wires to the MCB.
10
-
-
1No 30 Amps Electronic Key Tag + Key card in modular plate and termination of wires to the key control tag.
10
-
-
Supply, replacement and testing of following Lamp holders suitable for various type of luminaries as per the detailed specification and as directed by Engineer-in-charge
-
-
-
Fancy Type Angle / Batten Holder
300
-
-
Supply, replacement and testing of the following electrical accessories / control gears as per the detailed specification and as directed by Engineer-in-charge.(Refer Sec VI (MNC), Clause No.12).
-
-
-
Bi-Pin Twist Lock Lamp Holder suitable for 28/36/40 Watts Fluorescent Lamps.
400
-
-
Universal Starter for 20/40 Watts Fluorescent Lamp as per Cat. No.S-10.
150
-
-
Electronic ballast Suitable for 1 X 36 Watts Fluorescent fitting.
250
-
-
Electronic ballast Suitable for 1 X 18 Watts Fluorescent fitting.
50
-
-
Supply, replacement and testing of 18 W Ultra violet lamp (ACTINIC) suitable for flying insect controller equipment and working voltage is 240V AC as per the detailed specification and as directed by Engineer-in-charge.
10
-
-
Supply and replacement of following Calling bells as per the detailed specification and as directed by Engineer-in-charge.
-
-
-
Calling bell - Ding Dong type
150
-
-
calling bel - Musical chime type
10
-
-
Supply, replacement and testing of 9 inches Gong Bell as per the detailed specification and as directed by Engineer-in-charge.
2
-
-
Supply, replacement and testing of 63 Amps, 3 Pole MCCB as per the detailed specification and as directed by Engineer-in-charge.
2
-
-
Supply and Embedment of 50mm Deep, Square/Rectangular Concealed type and GI double earthed modular metal boxes of the following types and as specified in RCC/Brick/Concrete Block Masonry with finishing and making good as per the detailed specification. (Refer Sec VI, Clause No.15.12).
-
-
-
ONE/TWO Module
10
-
-
THREE Module
40
-
-
FOUR Module
20
-
-
SIX Module
10
-
-
Supply and Installation of following sizes of Surface Mounting Plastic Boxes as per the detailed specification. (Refer Sec VI, Clause No.15.6).
-
-
-
Surface Mounting Plastic Boxes 1/2 Module
5
-
-
Surface Mounting Plastic Boxes 3 Module
15
-
-
Surface Mounting Plastic Boxes 4 Module
10
-
-
Surface Mounting Plastic Boxes 6 Module
10
-
-
Surface Mounting Plastic Boxes 12 Module
10
-
-
Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18)
-
-
-
Wiring with 1 Run of 1.5 Sq.mm Copper wire
180
-
-
Wiring with 1 Run of 2.5 Sq.mm Copper wire
180
-
-
Wiring with 1 Run of 4 Sq.mm Copper wire
90
-
-
Wiring with 1 Run of 6 Sq.mm Copper wire
90
-
-
Supply, transportation, replacement, testing and commissioning of the following LED Luminaires of suitable wattage as per the detailed specification and as directed by the Engineer-in-charge. (Refer Sec VI, Clause No.16.0).
-
-
-
6W (Max), 700 lm output, 6500K, IP 66 Protection LED Bulkhead with Aluminium die cast housing and polycarbonate diffused cover suitable for surface mounting.
50
-
-
12W (Max), 1200 lm output, 6500 K, 600 mm long, LED batten with extruded Aluminium housing, suitable for Ceiling and Wall mounting.
150
-
-
18W (Max), 2000 Im output, 6500K, 150mm dia size, recess mounting LED Luminaires with aluminium dia cast housing.
50
-
-
15W (Max), 1600 lumen output, 6500K, square /round type, LED Luminaires with polycarbonate material housing, suitable for surface mounting.
30
-
-
36W (Max), 3600 lm output, 6500 K, 600mm x 600mm Recessed mounting type LED Light with CRCA housing suitable for 2 x 2 grid false ceiling.
30
-
-
31W (Max), 3200 lm output, 6500 K, 600mm x 600mm surface mounting type LED Light with CRCA housingsurface mounting.
4
-
-
29W (Max), 4000 lm output, 6500 K, 1200 mm long, LED batten with CRCA housing, suitable for Ceiling, Wall and Downrod mounting.
30
-
-
17W (Max), 2000 lm output, 6500 K, 1200 mm long, LED Battern with CRCA housing, suitable for ceiling, wall and downrod mounting.
20
-
-
20W (Max), 2000 lm output, 6500 K, 1200 mm long, LED Battern with Polycarbonate housing, suitable for ceiling and wall mounting.
400
-
-
Replacement of fluorescent lamps with LED Lamps including supply of 20W, 4 feet, 25mm dia, LED tube with built-in ballast (CG) or Equivalent and required rewiring inside the luminaires as per the detailed specification enclosed. (Refer Sec VI (MNC), Clause No.12.0).
30
-
-
Tracing and rectification of defects in the Electrical installation in residential and public buildings as per the detailed specification and as directed by Engineer-in-charge. (Refer Sec VI (MNC), Clause No.4.0).
3500
-
-
Replacement, testing and commissioning of electrical components such as switch /socket / Ballast / Holder / Modular plates and Lamps etc, as per the detailed specification and as directed by Engineer-in-charge.
Note:- Required Electrical component will be issued at free of cost cited above as applicable by the Department.
400
-
-
Preventive Maintenance of Bus bar trunking systems as per the detailed specification and as directed by Engineer-in-charge.
33
-
-
Preventive Maintenance of G+2 Stair case / Tower building Energy Meter Distribution Board (EMDB) as per the detailed specification and as directed by Engineer-in-charge.
515
-
-
Preventive Maintenance of 3 Phase Energy Meter Distribution Board (EMDB) in Residential building (Type V E) as per the detailed specification and as directed by Engineer-in-charge.
136
-
-
Preventive Maintenance of 8/12 Way 16/32/63 Amps MCB Power and Lighting Distribution Boards located in various public buildings as per the detailed specification and as directed by Engineer-in-charge. (Refer Sec VI (MNC), Clause No.17.3).
300
-
-
Carrying out healthiness check of RCCB, MCB in TPN/SPN 12/8/6 way DB including checking of earth continuity of the distribution system at following type of residential quarters as per the detailed specification and as directed by the Engineer-in-charge. (Refer Sec VI (MNC), Clause No.17.3).
-
-
-
Type B / C / SA type Residential Quarters
850
-
-
Type D / E Residential Quarters
850
-
-
Carrying out Full House Maintenance in various types of Residential buildings as per the detailed specification and as directed by Engineer-in-charge.
-
-
-
Full House Maintenance of Type B / C / SA type Residential Quarters (Entire House)
100
-
-
Full House Maintenance of Type D / E Residential Quarters (Entire House)
80
-
-
Cleaning of Stair Case/Tower Panel (EMDB) as per the specification in the scope of work and as directed by the Engineer-in-charge.
515
-
-
Cleaning of 3 Phase EMDB in Residential building (Type VE) as per the specification in the scope of work and as directed by the Engineer-in-charge.
100
-
-
Cleaning of ceiling mounted, fluorescent fittings, CFL and LED luminaries in Residential and Public Buildings like Office rooms, class rooms, Lobbys, Rest rooms etc. as per detailed specification and as directed by Engineer-in-charge.
1000
-
-
Identification and rectification of shunt or series fault in lighting or power circuit wiring in building as per scope of work (Refer Sec VI (MNC), Clause No.4).
-
-
-
Minor fault
30
-
-
Major fault
15
-
-
Supply and Installation of 25 X 12 mm size of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29)
150
-
-
Supply, installation, testing and commissioning of 4 module plate with 20 A starter, 16 A socket heavy duty and 16 A plug top with indicator on already embedded metal box as per detailed specification and as directed by Engineer-in-charge.
15
-
-
Wiring for AC point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits or Trunking as per the detailed scope of work, including supply of 2 Runs of 4Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18)
150
-
-
Painting of 415V Switchboards, Cubicle switch boards having number of vertical sections up to 3, with One coat of synthetic enamel Paint including supply of paints and required consumables as per detailed specification and as directed by Engineer-in-charge.(Refer Sec VI (MNC), Clause No.3).
5
-
-
Supply and Installation of laminated Hylam sheet of 3mm thickness over the boxes and as per the detailed specification.
3
-
-
Excavation in hard soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)
5
-
-
Supply and Installation of 6 levers long shackle brass lock with master key as per detailed specification and as directed by Engineer-in-charge.
170
-
-
Supply and replacement of following heater coils / thermostat as per the detailed specification and as directed by the Engineer-in-charge. (Refer Sec VI (MNC), Clause No.13).
-
-
-
230V, 1/2 kW, Single phase Heater coil suitable for BAIN MARIE/Geyser.
3
-
-
230V, 3kW, Single phase, Heater coil suitable for DOSA TAWA / IDLI BOILER / Instant water heater etc.
3
-
-
240 Volts, 16 Amps, 50 Hz. Thermostat with adjustable Temperature Range 20 - 80 degree Centigrade.
3
-
-
Maintenance and Servicing of Rice/Idly boiler, Bain maries and Hot Plates, including contacts installed in kitchen as per the detailed scope of work and as directed by the Engineer-in-charge. (Refer Sec VI (MNC), Clause No.13).
6
-
-
Supply and fixing of DO's & DONT's display board at side wall of lift car. The board made up of 2mm thick, A3 (11.7'' X 16.5'') size Acrylic sheet with colour print and affixing white background sheet including 6 Nos. of stainless steel screws for fixing as directed by Engineer-in-Charge.
120
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%