Department Of Atomic Energy Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Department Of Atomic Energy - DAE Tender
Security and Emergency Services
Eprocure
Opening Date21 Aug 2024
Closing Date17 Sep 2024
Tender Amount₹ 74,28,000
Costs
EMD
₹ 1,48,560Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GSO_822071_1Bid Award Id
ViewTender No
GSO/CTC/MSD/79/2024Tender Authority
Department Of Atomic Energy ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Form of Agreement to be signed and uploaded
Annexure 2 to 4 to be signed and uploaded
Technical Bid to be filled and uploaded and Forms ACDFG to be filled and Uploaded
BOQ Items
... More
Supply Installation Testing and Commissioning of UL listed and FM approved (or) any equivalent standard Intelligent Addressable microprocessor based Multicriteria detector, Provides enhanced detection having two optical and two thermal sensors or two Optical One Thermal or equivalent multi criteria detector having Differentiates between deceptive phenomena and an actual fire (nuisance-alarm avoidance) and complying with NFPA as 'VEWFD' high-sensitivity detector. Shall have Up to 22 application profiles. with five (5) possible field-selectable temperatures combined with four (4) rate-of-rise options.Tri color LED, Green for Normal, Amber /yellow for trouble and Red for alarm. Shall be Polarity Insensitive; all as per specification and as directed by Engineer In Charge
2
-
-
... More
Supply Installation Testing and Commissioning of Conventional Sounder cum strobe having 2 different tone settings with range of 90 dbA and 95 dbA and field selectable 15/30/75/110 candelas; providing separte output module and 24 V DC power supply] with control module; all as per specification and as directed by Engineer In Charge
30
-
-
... More
Supply Installation Testing and Commissioning of UL listed Intelligent addressable Class X type (Style 7) Manual Call Point, Single Action, Shock and Vibration Resistant, with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal,Yellow for Faulty and RED for activation), T-45 Key Reset lockset for easy maintenance, Operating Temp and RH: 0-49degC and =95%. MCP shall have in-built isolator for better reliability; all as per specification and as directed by Engineer In Charge
26
-
-
... More
Supply and Installation of micro controller based Auto Dialer (GSM) based module to alert to mobile numbers through speech and SMS dialer; The Auto Dialer shall be capable of communicating to15 different mobile number during emergency call and shall capable of 20 secounds recorded message to the each number shall be communicated for each message; all as per specification and as directed by Engineer In Charge
22
-
-
... More
Supply and Installation of 2Cx1.5 Sq mm Armoured Cable; as per specification and as directed by Engineer In Charge
1500
-
-
... More
Removal of old 2C x 1.5 Sq mm armoured cables installed in various location, which includes removing of saddle support present in the cable, filling the removed portion of saddle with putty cement matching to the wall paint; the scope of work also includes removing of detector, Manual Call Point (MCP), sounder present in the loop etc... all complete as per directions and approval of Engineer-in-charge.
150
-
-
... More
Providing Telescopic pole of 4.5 m + 1.13 m along with Detector Removal Tool Kit; Dispenser Kit and Aerosol A10S (Non Flammable) of total 10 Nos; all complete as per directions and approval of Engineer-in-charge.
1
-
-
... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side at all height made with 40mm diameter M.S. tube spaced @ 1.5 m centre to centre at both horizontal and vertical tubes, joining with cup and lock system with M.S.tube, M.S.tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners connection with the building, etc., Wherever required for the inspection of work at required location with essential safety features for the workmen, etc., complete as per directions and approval of Engineer-in-charge. (Note: The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.)
1000
-
-
... More
Carryingout IR testing for all the armourced cables installed in the locations irespective of the length of the loop not more than 200 m or 25 detectors; Testing of cables which includes removing the old detector/Manual Call Point/Sounder etc... present in the loop; interconnecting the cable between the detector to ensure the continuity in the cable; measuring the IR values in the loop by using insulation tester resistance meter, all complete as per directions of Engineer-in-charge.
30
-
-
... More
Supply and fixing of 20 mm Cassing and Capping; as per specification and as directed by Engineer In Charge
50
-
-
... More
Supply and Fixing of Glanding on the Panel, Detector, Sounder, MCP along with proper termination; as per specification and as directed by Engineer In Charge
720
-
-
... More
Supply and Laying of 3 core X 2.5 Sq.mm armoured cable; as per specification and as directed by Engineer In Charge
60
-
-
... More
Supply and Installation of 10A 2 pole MCB with back box along with enclosure along with proper termination; all complete as per directions of Engineer-in-charge.
22
-
-
... More
Removal of old existing panel installed in the substation; which includes dismantling of base frame, cables and other accessories; all as per directions and approval of Engineer-in-charge.
12
-
-