Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Department Of Atomic Energy - DAE Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Nov 2024
Closing Date24 Dec 2024
Tender Amount₹ 48,10,000 
Notes
Download

Costs

Summary

Maintenance Of 11kv Substation Equipment And Associated Works In Kalpakkam Township For The Year 2025-2026.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cubical Switchboards having number of vertical sections more than 12 and up to 19.

1

-

-

... More
Cubical Switchboards having number of vertical sections up to 2

1

-

-

... More
Maintenance of following 11 KV indoor Circuit Breaker as per detailed specification and as directed by the Engineer-In-Charge.

-

-

-

... More
Maintenance of 11 kV, Vacuum Circuit Breaker

32

-

-

... More
Vacuum integrity test for 11 kV Vacuum Circuit Breaker

25

-

-

... More
Testing of all types of Numerical and Electromagnetic protection relays using 3Phase Current injecting calibration kit, as per the detailed specification and as directed by the Engineer-in-Charge.

127

-

-

... More
Maintenance of following 11 kV / 433Volts Distribution Transformer as per detailed Specification and as directed by Engineer-in-charge

-

-

-

... More
Distribution Transformer of capacity 500 kVA to 7 MVA (Refer Sec VI (MNC), Clause No.18.1).

10

-

-

... More
Distribution Transformer of capacity 250 kVA up to 400 KVA (Refer Sec VI (MNC), Clause No.18.1).

18

-

-

... More
Overhauling and Maintenance of Distribution Transformer at Site, including draining of oil, opening of transformer top cover, supply, replacement of all gaskets, oil seals, 'O' rings, Oil filtration, arrangement of all required special tools & equipment as per the detailed specification and as directed by the Engineer-in-Charge.

-

-

-

... More
11KV/433V Up to 500KVA, ONAN, Distribution Transformer

1

-

-

... More
11KV/433V above 500kVA and up to 1500KVA, ONAN, Distribution Transformer

1

-

-

... More
Supply and replacement of 1 Kg Silica gel breather container made out of Aluminium top and bottom, transparent tubular container with clear view oil cup including silica gel and necessary coupling arrangement as per the detailed specification and as directed by the Engineer in Charge.

6

-

-

... More
Supply and replacement of Silica gel in Breathers of Transformers/Bus ducts/Storage Tanks as per the detailed Specification and as directed by the Engineer-in-charge.

10

-

-

... More
Reconditioning of Silica gel in Breathers of working Transformers and Bus ducts (Refer Sec VI (MNC), Clause No.20).

200

-

-

... More
Transformer oil sample collection at site, Transporting to NABL Accredited testing laboratory, Carrying out the tests mentioned as per the detailed Specification, submission of test reports and as directed by Engineer-in-charge.

24

-

-

... More
Collection of Transformer oil samples and Conducting Break Down Voltage test at Site. (Refer Sec VI (MNC), Clause No.20.3).

5

-

-

... More
Collection of Transformer Oil in 20 litre container from sub-store electrical, transportation to various substations within a range of up to 3kms and topping up of into the Transformers as per the detailed Specification and as directed by the Engineer-in-Charge. (Oil will be issued as a free issue item by the Department)

5

-

-

... More
Operation of filtration plant for Reconditioning of Transformer oil in Transformers / storage Tank / Drums / BOCBs. (Refer Sec VI (MNC), Clause No. 20.1).

100

-

-

... More
Maintenance of 415 Volts Power control centres / LT panels, Busducts, TPN switch Fuse Units and ACBs (Refer Sec VI (MNC), Clause No.17.2).

-

-

-

... More
415 Volts PCC Panel consisting of 3 Nos of ACBs and Cubical Switchboards having number of vertical sections up to 10.

2

-

-

... More
415 Volts PCC Panel consisting of 5 Nos of ACBs and Cubical Switchboards having number of vertical sections up to 11 and 2 Nos Bus Ducts.

1

-

-

... More
415 Volts PCC Panel consisting of 7 Nos ACBs, Cubical Switchboards having number of vertical sections up to 15 and 2 Nos Bus Ducts.

1

-

-

... More
415 Volts PCC Panel consisting of 8 Nos ACBs, Cubical Switchboards having number of vertical sections up to 12.

1

-

-

... More
415 Volts PCC Panel of Tower Blocks consisting of 2 Nos of ACBs and Cubical Switchboards having number of vertical sections up to 5.

2

-

-

... More
Maintenance of 415 Volts Distribution Centres, LT panels / TPN switch Fuse Units (Refer Sec VI (MNC), Clause No.17.2).

-

-

-

... More
Cubicle switch boards having number of vertical sections up to 3

11

-

-

... More
Cubicle switch boards having number of vertical sections more than 3

5

-

-

... More
Maintenance of 415 Volts DG AMF Panel as per detailed Specification. (Refer Sec VI (MNC), Clause No.17.2).

-

-

-

... More
320 / 380 kVA, AMF Panel with 3 Nos ACBs and Cubical Switchboards having number of vertical sections up to 7.

4

-

-

... More
140 / 250 kVA AMF Panel with 2 Nos Contactors and Cubical Switchboards having number of vertical sections up to 5.

4

-

-

... More
Maintenance of 415 Volts Feeder Pillar (Refer Sec VI (MNC), Clause No.17.2).

-

-

-

... More
Maintenance of Feeder Pillar (Type-A)

67

-

-

... More
Maintenance of Feeder Pillar (Type-B)

25

-

-

... More
Maintenance of Feeder Pillar (Type-C)

90

-

-

... More
Top up of Diesel to the DG Set diesel tanks using the available empty Diesel drums (200 Litre capacity) including transportation of empty drums to the fuel filling station (Petrol bunk), filling diesel to the empty drums and toping up the same to the diesel tanks of the DG sets, located at various places within the range of 10 kms inside the Township as per specification and as directed by the Engineer-in Charge.

6

-

-

... More
Maintenance of 2.2 kVA Portable Genset as per the detailed specification and as directed by Engineer-in-charge

12

-

-

... More
Supply, replacement of 12 Volts, Heavy duty DG Starting Batteries including supply of 2 Nos Copper terminal clamps and Installation, Testing as per the detailed specification and as directed by Engineer-in-charge

2

-

-

... More
Maintenance of Batteries, Battery banks & Battery Charger etc.,

-

-

-

... More
Curative discharge and charge on VRLA Battery Banks of voltage more than 48 V & up to 110 V. (Including hourly recording of all cell voltages) (Refer Section VI (MNC), Clause No. 8.0.)

12

-

-

... More
Maintenance of Battery chargers as per the detailed specification and as directed by the Engineer-In-Charge. (Refer Sec VI (MNC), Clause No. 8.0).

13

-

-

... More
Maintenance of Lead Acid Batteries including Supply of distilled water and top up, cleaning and recording of readings as per detailed Specification. 

240

-

-

... More
Maintenance of 110 Volt, VRLA type sealed maintenance free Lead Acid Battery bank as per the detailed specification.

156

-

-

... More
Supply, Replacement of Panel board components including removal of faulty components, as per the detailed specification and as directed by the Engineer-in-Charge.

-

-

-

... More
Panel LED Indication Lamp Dia '22.5' mm, of colour Red / Yellow / Green / Amber suitable for operating to 24V to 240V AC/DC.

75

-

-

... More
Panel LED Indication Lamp Dia '22.5' mm, of colour Blue / White suitable for operating to 24V to 240V AC/DC.

50

-

-

... More
Providing set of 3 Nos of LED Indication lamp (Red, Yellow, Blue) with inscription plate on lamp, required 1.5 Sq.mm FRLS Copper wire, Din rail and copper lugs etc, as per the detailed specification.

1

-

-

... More
230Volts, 60 / 80 watts Panel mounting Space Heater.

15

-

-

... More
Thermostat 25-85 deg suitable for panel mounting

5

-

-

... More
Panel door lock suitable for existing panel door.

200

-

-

... More
Supply, installation, testing and commissioning of the following SDFU with factory made enclosure with 3Nos Fuse links on MS frame work as per the scope of work. (MS item will be measured separately). (Refer Sec VI, Clause No.14.1).

-

-

-

... More
SDFU TPN 63A, DIN FUSES with 3Nos 63A HRC fuse links, Sheet steel enclosure FN Cat No:SK90484

1

-

-

... More
SDFU TPN 125A, DIN FUSES with 3Nos 125A HRC fuse links, Open Execution FN Sheet steel enclosure FN Cat No:SK90486

1

-

-

... More
SDFU TPN 250A, DIN FUSES with 3Nos 250A HRC fuse links, Sheet steel enclosure FN Cat No:SK90489

1

-

-

... More
Supply, installation, testing and commissioning of the following manual on load Change over Switch - disconnector with factory made sheet steel enclosure mounted on MS frame work as per the scope of work. (MS item will be measured separately).

-

-

-

... More
FP 63A, 415V, AC 23A mounted in a Sheet steel enclosure

2

-

-

... More
FP 125A, 415V, AC 23A mounted in a Sheet steel enclosure

1

-

-

... More
FP 250A, 415V, AC 23A mounted in a Sheet steel enclosure

1

-

-

... More
Replacement of 415 Volts SDFU/MCCBs in the existing LT Panel, including removal of existing SDFU/MCCB, suitable modification of Aluminium busbars, fasteners, FRP partitioning, Testing and Commissioning as per the detailed specification. Note: Required 415 Volts SDFU / MCCB will be supplied by department as Free Issue, all other consumables will be supply and installation.

-

-

-

... More
400/250 Amps TPN/4 Pole SDFU/MCCBs

2

-

-

... More
125/63 Amps TPN/4 Pole SDFU/MCCBs

2

-

-

... More
Supply, replacement of following components including removal of existing components etc. as per the detailed specification and as directed by Engineer-in-charge.

-

-

-

... More
2 A to 10 A, 415 V, HRC Fuse Links (Offset / Staggered Fixing Type)

5

-

-

... More
Push Button Flush Head (Cat. No: HD15C), Green/Black/Yellow/White/ Blue/Orange) with 2 Nos Auxiliary block.

1

-

-

... More
Push Button Mushroom Head (Push Turn, Colour Red, Cat. No: HH55C1) with 2 Nos Auxiliary block.

2

-

-

... More
Surveillance visit for Switchgear rooms, Transformer bays and DG rooms etc., including recording load parameters, abnormalities, etc., as per the detailed specification and as directed by the Engineer-In-Charge.

48

-

-

... More
Maintenance of Earth Pits including supply of Sodium Bentonite, and measurement of Earth Pit Resistance as per the specification and as directed by the Engineer in Charge. (Refer Sec VI (MNC), Clause No.2).

120

-

-

... More
Maintenance of Earth Pits and measurement of Earth Pit Resistance as per the specification. (Refer Sec VI (MNC), Clause No.2).

250

-

-

... More
Demolition of Earth Pit chamber, transporting and storage of masonry debris in specific location with a maximum lead of 3 Kms. approximately including excavation and re-filling and as directed by Engineer-in-charge.

20

-

-

... More
Supply and replacing following earth pit chamber parts after removing and disposing off old/damaged part as per drawing No. IGC/ESD/5060/1008/1. (Refer Sec VI (MNC), Clause No.2.0).

-

-

-

... More
RCC Top Cover alone

50

-

-

... More
RCC Ring Collar alone

30

-

-

... More
RCC Ring with Cover

10

-

-

... More
Supply and replacing of RCC Cable Identification marker for HT Cable / LT Cable / Cable Joint as per drawing and inscription as directed by Engineer-in-Charge and as per detailed specification.

50

-

-

... More
Supply and installation of 8 SWG copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8)

25

-

-

... More
Supply and replacement of 7/11 SWG (7 strand 11SWG) G.I Stay wire on HT Structures and Poles of 11KV Feeder No. 1 and 2, including removal of existing stay wire, fasteners etc., as per detailed specification and as directed by the Engineer-in-Charge.

5

-

-

... More
Cleaning and water washing of Solar Photo Voltaic Panel, cleaning with solvent and removal of vegetation growth, dry leaves all around the Solar PV panel system as per the detailed specification.

12288

-

-

... More
Removal of existing blue metal stones from the transformer bay, cleaning using suitable oil removing agent followed by water washing, drying and refilling back into the transformer bay as per the detailed Specification and as directed by the Engineer-in-Charge

40

-

-

... More
Supply and Painting with One coat of Synthetic enamel paint on metallic surfaces of electrical equipment, and other required surface at all levels with primer and following paint (Asian or approved brand, colour and manufacturer) to give an even shade including preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-Charge. (Refer Sec VI (MNC), Clause No.3).

200

-

-

... More
Painting of 415V Switchboards with Two coats of synthetic enamel Paint including supply of paints and required consumables (Refer Sec VI (MNC), Clause No.3).

-

-

-

... More
Cubicle switch boards having number of vertical sections up to 3 (Refer Sec VI (MNC), Clause No.3)

2

-

-

... More
Cubicle switch boards having number of vertical sections above 3 and up to 6 (Refer Sec VI (MNC), Clause No.3).

2

-

-

... More
Cubicle switch boards having number of vertical sections above 6 (Refer Sec VI (MNC), Clause No.3).

1

-

-

... More
Painting of Distribution Equipment with ONE Coat of Primer, TWO Coat of Synthetic Enamel Paint including supply of paint & primer and required consumables .(Refer Sec VI (MNC), Clause No.3).

-

-

-

... More
Up to 750 kVA Transformer

4

-

-

... More
Above 750 kVA and up to 1500 kVA Transformer

2

-

-

... More
Feeder Pillars - Type - A

8

-

-

... More
Feeder Pillars - Type-B

4

-

-

... More
Feeder Pillars - Type-C

15

-

-

... More
Lettering the Substation/Feeder pillar etc., in following size and shape with synthetic enamel paint of different background colours, letter colour & size of letter as directed by Engineer in Charge. (Refer Sec VI (MNC), Clause No.10.3).

-

-

-

... More
With in 200 mm dia/ (225x100mm area) Single letter of approved font and colour. (Measurement shall be paid for each letter as 1 No).

170

-

-

... More
300 mm size single letter of approved font and colour. (Measurement shall be paid for each letter as 1 No).

50

-

-

... More
Lettering on electrical equipment with in the area of 500 x 100mm without background colour, multiple letters, size and colour as directed by Engineer in Charge. (Refer Sec VI (MNC), Clause No.10.3).

140

-

-

... More
Supply and Installation of following general electrical items as per the detailed specification (Refer Sec VI (MNC), Clause No.5).

-

-

-

... More
water proof stickers of 250 x 50 mm size with messages as directed by Engineer in charge

100

-

-

... More
Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11).

-

-

-

... More
MS fabrication 1 coat primer & 2 coats synthetic enamel paint.

150

-

-

... More
Trimming Tree Branches near & around the Street Light Luminaries / ABC Spun Poles including disposal of removed branches to location within 3 kms, as specified by Engineer-in-Charge. Each street light pole will be considered as 1 No. for measurement. (Refer Sec VI (MNC), Clause No.7.1).

25

-

-

... More
Replacing of old worn out / Damaged Substation Lock and keys with new 6 lever lock and Keys set including supply of new locks with 3 keys for each lock and Key tags on Aluminium anodised plate as per the detailed Specification

24

-

-

... More
Carrying out Tap changing operations in distribution Transformer including measurement of winding resistance before and after tap changing as per detailed Specification and as directed by the Engineer-In-Charge.

2

-

-

... More
Carrying out Breakdown Maintenance /Trouble shooting /Renovation & Modification works in 11 kV / 415 V Distribution System as per detailed Specification and as directed by the Engineer-In-Charge. 

200

-

-

... More
Shifting of following Heavy Electrical equipment including safe loading, transportation and unloading. (Refer Sec VI (MNC), Clause No.31).

-

-

-

... More
Equipment weighing up to 100 kgs within a distance of 500 meters

10

-

-

... More
Equipment weighing up to 100 kgs for a distance more than 500 meters and up to a distance of 5 kms

10

-

-

... More
Equipment weighing more than 100 kgs and up to 500 kg within a distance of 500 mtrs.

8

-

-

... More
Heavy Electrical equipment (more than 500 kgs and up to 5 Tons) within a distance of 1 kms

4

-

-

... More
Heavy Electrical equipment (more than 500 kg and up to 5 Tons) within a distance of 5 kms.

2

-

-

... More
Shifting of oil filtering machine/transformers of capacity more than 100 kVA within a distance of 500 m.

8

-

-

... More
Shifting of oil filtering machine/ transformers of capacity more than 100 kVA distance of more than 500m and up to 5Km.

4

-

-

... More
Supply, replacement of Rewireable Porcelain Fuse Unit complete set in the existing feeder pillar as per the detailed specification and as directed by the Engineer in Charge.

-

-

-

... More
415 Volts, 63Amps

3

-

-

... More
415 Volts, 100Amps

6

-

-

... More
Loading, Transportation, Unloading at site, installation, Testing and Commissioning of one number PVC/HRPVC/XLPE insulated, PVC sheathed armoured power cable of 11kV grade, the following sizes of cable direct in ground including excavation, sand cushioning, protective covering, with two sides with chamber burnt/cement brick & top PCC slab, RCC route marker and refilling the trench etc as required. (Note: Cable will be issued free of cost by the department). (Refer Sec VI, Clause No.3)

-

-

-

... More
Above 3C x 120 sq.mm but not exceeding 3C x 240 sq. mm

50

-

-

... More
Up to 3C x 120 sq. mm

50

-

-

... More
Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 11kVolts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)

-

-

-

... More
3 Core x above 120 to up to 240 Sq.mm

25

-

-

... More
Up to 3C x 120 sq. mm

25

-

-

... More
Loading, Transportation, Unloading at site, Laying, Testing and Commissioning of one number PVC/HRPVC/XLPE insulated and PVC sheathed Stranded Aluminium/copper conductor power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)

-

-

-

... More
3/3.5/4 Core x up to 25 Sq.mm

75

-

-

... More
3/3.5/4 Core x above 25 to 3/3.5/4 Core X up to 120 Sq.mm

75

-

-

... More
3/3.5/4C x Above 120 Sq.mm but not exceeding 3.5/4CX 240 Sq.mm

50

-

-

... More
3/3.5/4 Core x Above 240 Sq.mm to 3/3.5/4Core X 400 Sq.mm

50

-

-

... More
Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)

-

-

-

... More
3/3.5/4core x Up to 25 Sq.mm

25

-

-

... More
3/3.5/4Core x above 25 & up to 120 Sq.mm

25

-

-

... More
3/3.5/4Core x above 120 & up to 240 Sq.mm

25

-

-

... More
3/3.5/4Core x above 240 & up to 400 Sq.mm

25

-

-

... More
Retrieval of the already laid one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 11 KV grade of following sizes laid direct in ground including retrieval of end termination, excavation of trenches, retrieving of bricks, back filling and Re - laying the same cable direct in ground by using retrieved bricks including transportation of cables, excavation and backfilling of soil, supply of sand, shortage bricks etc as per the detailed specification. (Refer Sec VI, Clause No.7)

-

-

-

... More
3 Core Above 120 & Up to 240 Sq.mm

50

-

-

... More
3 Core Up to 120 Sq.mm

50

-

-

... More
Retrieval of the already laid one number 11kV (E), 3 Core, Aluminium Conductor, XLPE insulated Power cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of GI spacer, clamps etc and relaying the same cable in built-in trenches, on walls, poles and through embedded pipes using the retrieved Spacer & clamp & supplying the shortage Spacer & clamp if any as per the detailed specification. (Refer Sec VI, Clause No.7)

-

-

-

... More
3 Core Above 120 & up to 240 Sq.mm

20

-

-

... More
3 Core Up to 120 Sq.mm

20

-

-

... More
Retrieval of the already laid one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes laid direct in ground including removal of end termination, excavation of trenches, retrieving of bricks, back filling and Re - laying the same cable direct in ground by using retrieved bricks including transportation of cables, excavation and backfilling of soil, supply of sand & shortage bricks etc as per the detailed specification. (Refer Sec VI, Clause No.7)

-

-

-

... More
3/3.5/4 Core up to 25 sq.mm

50

-

-

... More
3/3.5/4 Core Above 25sqmm & up to 120 Sq.mm

50

-

-

... More
3/3.5/4 Core Above 120sqmm & up to 240 Sq.mm

50

-

-

... More
3/3.5/4 Core Above 240sqmm & up to 400 Sq.mm

50

-

-

... More
Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of GI spacer, clamps etc and relaying the same cable in built-in trenches, on walls, poles and through embedded pipes using the retrieved spacer & clamp & supplying the shortage spacer & clamp if any as per the detailed specification. (Refer Sec VI, Clause No.7)

-

-

-

... More
Up to 3/3.5/4 C X 25 Sq.mm

25

-

-

... More
3/3.5/4 Core Above 25 & up to 120 Sq.mm

25

-

-

... More
3/3.5/4 Core Above 120 & up to 240 Sq.mm

20

-

-

... More
3/3.5/4 Core Above 240 & up to 400 Sq.mm

20

-

-

... More
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).

-

-

-

... More
4 C x 10 Sq.mm

5

-

-

... More
4 C x 16 Sq.mm

4

-

-

... More
3.5 C / 4 C x 25 Sq.mm

4

-

-

... More
3.5 C / 4 C x 35 Sq.mm

4

-

-

... More
3.5/4 C x 50/70 Sq.mm

2

-

-

... More
3.5/4 C x 95 / 120 Sq.mm

4

-

-

... More
3.5 C x 185 Sq.mm

2

-

-

... More
3.5 C x 240 sq.mm

2

-

-

... More
3.5 C x 400 Sq.mm

2

-

-

... More
Removal of termination of armoured cables of following sizes from electrical equipment or reconnecting of removed termination as per the detailed specification and as directed by Engineer-in-Charge. (Refer Sec VI, MNC, Clause No.27.0)

-

-

-

... More
Sizes up to 4C x 25 Sq.mm

4

-

-

... More
Sizes above 3.5/4C x 25 Sq.mm and up to 3.5/4C X 70 Sq.mm.

2

-

-

... More
Sizes above 3.5/4C x 70 Sq.mm and up to 3.5/4C X 95/120 Sq.mm

2

-

-

... More
Sizes above 3.5/4C x 120 Sq.mm and up to 3.5/4C X 185 Sq.mm

2

-

-

... More
Sizes above 3.5/4C x 185 Sq.mm and up to 3.5/4C X 240 Sq.mm

2

-

-

... More
Sizes above 3.5/4C x 240 Sq.mm and up to 3.5/4C X 400 Sq.mm

2

-

-

... More
Assisting in cable straight through or transition jointing of following size of cables by providing minor excavation, transportation of gas cylinder, jointing materials & tools, dressing the cable wherever required after job completion etc as per site condition and as directed by the Engineer-in-charge. (Refer Sec VI, Clause No.10.4)

-

-

-

... More
Voltage grade up to 1.1 kV & size up to 120 Sq.mm

8

-

-

... More
Voltage grade up to 1.1 kV of size exceeding 120 Sq.mm and up to 240 Sq.mm

3

-

-

... More
Voltage grade up to 1.1 kV of size exceeding 240 Sq.mm and up to 400 Sq.mm

2

-

-

... More
Assisting in cable straight through or transition jointing of following size of cables by providing temporary shelter, minor excavation, transportation of gas cylinder, jointing materials & tools, dressing the cable wherever required after job completion etc as per site condition and as directed by the Engineer-in-charge. (Refer Sec VI, Clause No.10.4)

-

-

-

... More
Voltage grade up to 11 kV of size exceeding 120 Sq.mm and up to 240 Sq.mm

1

-

-

... More
Voltage grade up to 11 kV of size up to 120 Sq.mm

1

-

-

... More
Supply, installation, testing and commissioning of the following Raychem make Heat Shrinkable Cable Straight Through Jointing Kits (Crimping type) for 3.5 Core Aluminium Conductor, 1.1 kV (E), PVC/XLPE insulated cables of following sizes as specified. Excavation will be measured separately (Refer Sec VI, Clause No.10.6).

-

-

-

... More
Straight Through Joint (Crimping type) for 4 Core, 10 - 16 Sq. mm

2

-

-

... More
Straight Through Joint (Crimping type) for 3.5 Core, 25- 50 Sq. mm

2

-

-

... More
Straight Through Joint (Crimping type) for 3.5 Core, 70-95 Sq. mm

2

-

-

... More
Straight Through Joint (Crimping type) for 3.5 Core, 120 - 185 Sq. mm

4

-

-

... More
Straight Through Joint (Crimping type) for 3.5 Core, 240 Sq. mm

1

-

-

... More
Straight Through Joint (Crimping type) for 3.5 Core, 400 Sq. mm

2

-

-

... More
Supply, installation, testing and commissioning of the following Raychem make Heat Shrinkable Cable Straight Through Jointing Kits (Mechanical Connector type/Crimping type) Rayfit tubing for 3 Core Aluminium Conductor, 11 kV (E), XLPE insulated cables of following sizes including excavation of soil, backfilling etc as specified. (Refer Sec VI, Clause No.10.6).

-

-

-

... More
Straight Through Joint (Crimping type) for 3 Core x 185 Sq. mm

1

-

-

... More
Straight Through Joint (Crimping type) for 3 Core x 50/95 Sq. mm

1

-

-

... More
Supply, installation, testing and commissioning of Raychem make the following Heat Shrinkable Cable End Termination without gland for 3 Core Aluminium Conductor, 11 kV, XLPE insulated cables of following sizes. (Refer Sec VI, Clause No.10.5).

-

-

-

... More
3 Core x 185 Sq.mm XLPE (Indoor)

1

-

-

... More
3 Core x 50/95 Sq.mm XLPE (Indoor)

1

-

-

... More
HT / LT Cable Fault Tracing and Locating by using TNEB Cable Fault Identification Kit including HT/LT Cable Route Tracing, Transportation from Chennai to Kalpakkam / Anupuram Township and back to Chennai and Transporting the kit within Kalpakkam / Anupuram Township

1

-

-

... More
Cutting, Grinding, painting the grinded edges and positioning of 6 mm thick chequered plates including transportation of chequered plates with in townships including supply of gas cylinder, consumables etc, as per the detailed specification and as directed by Engineer In Charge.

50

-

-

... More
Excavation in hard soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift up to 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)

20

-

-

... More
Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift up to 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)

80

-

-

... More
Supply and Installation of following Raychem make Heat Shrinkable, Insulating, CABLE REPAIR SLEEVE (wraparound sleeve) of various sizes suitable for 1.1KV XLPE/PVC insulated cables of following sizes as specified. Excavation will be measured separately.

-

-

-

... More
Cable repair sleeve for cable size up to 3.5/4C x 35 sq.mm, having Length of minimum 500mm

3

-

-

... More
Cable repair sleeve for cable sizes above 3.5/4C x 35 sq.mm and up to 3.5/4C x 120 sq.mm, having Length of minimum 700mm

2

-

-

... More
Cable repair sleeve for cable sizes above 3.5/4C x 120 sq.mm and up to 3.5/4C x 400 sq.mm, having Length of minimum 910mm

2

-

-

... More
Supply and open installation of following Sizes of MS boxes as per the detailed specification. (Refer Sec VI, Clause No.15.10).

-

-

-

... More
150(W)x150(H)x80(D)mm, 1.6mm thick sheet MS Box

12

-

-

... More
200(W)x200(H)x120(D)mm,1.6mm thick sheet MS Box

10

-

-

... More
300(W)x300(H)x120(D)mm,1.8mm thick sheet MS Box

6

-

-

... More
400(W)x300(H)x200(D)mm, 1.8mm thick sheet MS Box

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.