Chennai Petroleum Corporation Limited Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Chennai Petroleum Corporation Limited - CPCL Tender

Housekeeping Services
Eprocure
Opening Date7 May 2019
Closing Date13 May 2019
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Charges for operation of AC units in LEB/DHDS Control Room, LEB FPR Room, DHDS VFD Room, New LEB -SRU FPR, UPS room, New SRU VFD room. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC units in GT4 Control room, OPH DM FPR plant AC ,OPH UPS room, GT # 5 FPR, UPS rooms. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC unit in Refinery-1 Control room, Refinery-1 Field panel room, Optimization room and shift manager room ,OM&S Control room. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC units in QC Lab, fire station, CISF control room, IT server room and mounded bullet. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC unit in Euro-IV SRR1, SRR3, 110KV Yard, REF-III SRU FPR. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for Operation of AC units in HGU substation, HGU Field panel room, Euro-IV SRR-2. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC units in REF-III UPS Room -1, UPS room-2, N2 O2 FPR, SS#2 VFD room, Green canteen. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC units in GT-1,2 control room , GT-3 FPR, Co-gen DM, CPP DM , N2O2 plant FPR. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for Operation of Central and Package AC Units as per attached scope of work and SOQ for the first year 2019-20. BoQ Item Sl. No: 10.12 to 10.15 pertains to General shift area of operation

-

-

-

... More
Charges for operation of AC units in Workshop extension, Workshop Ground and first floor, and tech services building. UNIT OF MEASUREMENT- MANDAY One skilled operator per day + contribution of one supervisor per day per portfolio.

303

-

-

... More
Charges for operation of AC units in MM building Ground floor, first floor, second floor. UNIT OF MEASUREMENT- MANDAY ONE SKILLED OPERATOR PER DAY + CONTRIBUTION OF ONE SUPERVISOR PER DAY PER PORTFOLIO.

303

-

-

... More
Charges for operation of AC unit in New ADMIN, Old Training center( HRD-I), HRD-2 and Main canteen. UNIT OF MEASUREMENT- MANDAY ONE SKILLED OPERATOR PER DAY + CONTRIBUTION OF ONE SUPERVISOR PER DAY PER PORTFOLIO.

303

-

-

... More
Charges for operation of AC unit in R&D UNIT OF MEASUREMENT- MANDAY ONE SKILLED OPERATOR PER DAY + CONTRIBUTION OF ONE SUPERVISOR PER DAY PER PORTFOLIO.

303

-

-

... More
Charges for Operation of Central and Package AC Units as per attached scope of work and SOQ for SECOND YEAR 2020-21 NOTE: Shift (Round the clock) Operation Manpower to be maintainted during all 365 days in 9 portfolios. Payment shall be claimed based on Manpower attended per shift basis. No Manpower shall be allowed to continue to work more than 16 hours on any circumstance. General shift Operation and General shift Maintenance manpower to be provided 6 days week (Mon to Sat). BoQ Item Sl. No: 10.17 to 10.25 pertains to round the clock shift operation area.

-

-

-

... More
Charges for operation of AC units in Refinery-2 Control room, Refinery-2 First Floor, Refinery -2 Field panel room, Refinery-2 Maintenance room and WAX FPR. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC units in LEB/DHDS Control Room, LEB FPR Room, DHDS VFD Room, New LEB -SRU FPR, UPS room, New SRU VFD room. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC units in GT4 Control room, OPH DM FPR plant AC ,OPH UPS room, GT # 5 FPR, UPS rooms. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC unit in Refinery-1 Control room, Refinery-1 Field panel room, Optimization room and shift manager room ,OM&S Control room. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC units in QC Lab, fire station, CISF control room, IT server room and mounded bullet. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC unit in Euro-IV SRR1, SRR3, 110KV Yard, REF-III SRU FPR. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for Operation of AC units in HGU substation, HGU Field panel room, Euro-IV SRR-2. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC units in REF-III UPS Room -1, UPS room-2, N2 O2 FPR, SS#2 VFD room, Green canteen. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for operation of AC units in GT-1,2 control room , GT-3 FPR, Co-gen DM, CPP DM , N2O2 plant FPR. UNIT OF MEASUREMENT- EACH SHIFT ONE SKILLED OPERATOR PER SHIFT + CONTRIBUTION OF ONE SUPERVISOR PER SHIFT PER PORTFOLIO

1095

-

-

... More
Charges for Operation of Central and Package AC Units as per attached scope of work and SOQ for the SECOND YEAR 2020-21. BoQ Item Sl. No: 10.27 to 10.3 pertains to General shift area of operation.

-

-

-

... More
Charges for operation of AC units in Workshop extension, Workshop Ground and first floor, and tech services building. UNIT OF MEASUREMENT- MANDAY One skilled operator per day + contribution of one supervisor per day per portfolio.

303

-

-

... More
Charges for operation of AC units in MM building Ground floor, first floor, second floor. UNIT OF MEASUREMENT- MANDAY ONE SKILLED OPERATOR PER DAY + CONTRIBUTION OF ONE SUPERVISOR PER DAY PER PORTFOLIO.

303

-

-

... More
Charges for operation of AC unit in New ADMIN, Old Training center( HRD-I), HRD-2 and Main canteen. UNIT OF MEASUREMENT- MANDAY ONE SKILLED OPERATOR PER DAY + CONTRIBUTION OF ONE SUPERVISOR PER DAY PER PORTFOLIO.

303

-

-

... More
Charges for operation of AC unit in R&D. UNIT OF MEASUREMENT- MANDAY ONE SKILLED OPERATOR PER DAY + CONTRIBUTION OF ONE SUPERVISOR PER DAY PER PORTFOLIO.

303

-

-

... More
MAINTENANCE OF CENTRAL AC 2019-21:

-

-

-

... More
Charges for maintenance of central AC units for FIRST YEAR 2019-20 as per attached scope of work and SOR detailed below. Note: Areas mentioned below pertains to eight hours of operation (General Shift Area)

-

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN NEW ADMIN BLOCK. CAPACITY- 46 TR; QUANTITY- 3 UNITS; MODEL- 5H46 X 3; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN OLD TRAINING CENTER. CAPACITY- 60 TR; QUANTITY- 1 UNIT; MODEL- 5F60 X 1; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN NEW TRAINING CENTER. CAPACITY- 40 TR; QUANTITY- 2 UNITS; MODEL- 5F40 X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN WORKSHOP EXTENSION BUILDING. CAPACITY- 40 TR; QUANTITY- 1 UNIT; MODEL- 5H46 X 1; MAKE- Voltas; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN R&D MAIN BUILDING. CAPACITY- 40 TR; QUANTITY- 3 UNITS; MODEL- AC570 X3; MAKE- KIRLOSKAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
Charges for maintenance of central AC units for FIRST YEAR 2019-20 as per attached scope of work and SOR detailed below. Note: Areas mentioned below pertains to 24 hours of operation

-

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN REFINERY-1 CONTROL ROOM. CAPACITY- 46 TR; QUANTITY- 2 UNITS; MODEL- 5H-40 X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN REFINERY-1 OPTIMISATION ROOM. CAPACITY- 20 TR; QUANTITY- 2 UNITS; MODEL- 5F40X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN REFINERY-1 SHIFT MANAGER ROOM. CAPACITY- 20 TR; QUANTITY- 1 UNIT; MODEL- 5F40X 1; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN REFINERY-1 FIELD PANEL ROOM. CAPACITY- 66 TR; QUANTITY- 2 UNITS; MODEL- 5H66X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN LEB CONTROL ROOM. CAPACITY- 86 TR; QUANTITY- 2 UNITS; MODEL- 5H86X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN REFINERY-2 CONTROL ROOM. CAPACITY- 66, 80 TR; QUANTITY- 2 UNITS; MODEL- 5H-66X 1,KC4 X 1; MAKE- VOLTAS, KIRLOSKAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN REFINERY-2 FIRST FLOOR. CAPACITY- 40 TR; QUANTITY- 2 UNITS; MODEL- KC2 X1,5H46 X1; MAKE- KIRLOSKAR, VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN REFINERY-3 GT 1,2 CONTROL ROOM. CAPACITY- 48 TR; QUANTITY- 2 UNITS; MODEL- SMC4100 X 2; MAKE- Axcel; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN REFINERY- 3 SRU CONTROL ROOM. CAPACITY- 46 TR; QUANTITY- 2 UNITS; MODEL- 5H46 X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN TECHNICAL SERVICES BUILDING. CAPACITY- 40 TR; QUANTITY- 1 UNIT; MAKE- KIRLOSKAR; MODEL: AC570 X1 UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN GT4 CONTROL ROOM (SCREW CHILLER). CAPACITY- 90 TR; QUANTITY- 2 UNITS; MAKE- BLUESTAR; MODEL: HANDBELL RC-2-510AX2 UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN NEW SRU PLANT (SCREW CHILLER). CAPACITY- 50 TR; MAKE: VOLTAS MODEL: 5H86 X 2 QUANTITY- 2 UNITS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
Charges for maintenance of central AC units for SECOND YEAR 2020-21 as per attached scope of work and SOR detailed below. Note: Areas mentioned below pertains to eight hours of operation (General Shift Area)

-

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN NEW ADMIN BLOCK. CAPACITY- 46 TR; QUANTITY- 3 UNITS;,, MODEL- 5H46 X 3; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN OLD TRAINING CENTER. CAPACITY- 60 TR; QUANTITY- 1 UNIT; MODEL- 5F60 X 1; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN NEW TRAINING CENTER. CAPACITY- 40 TR; QUANTITY- 2 UNITS; MODEL- 5F40 X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN WORKSHOP EXTENSION BUILDING. CAPACITY- 40 TR; QUANTITY- 1 UNIT; MODEL- 5H46 X 1; MAKE- Voltas; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN R&D MAIN BUILDING. CAPACITY- 40 TR; QUANTITY- 3 UNITS; MODEL- AC570 X3; MAKE- KIRLOSKAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
Charges for maintenance of central AC units for SECOND YEAR 2020-21 as per attached scope of work and SOR detailed below. Note: Areas mentioned below pertains to 24 hours of operation

-

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN REFINERY-1 CONTROL ROOM. CAPACITY- 46 TR; QUANTITY- 2 UNITS; MODEL- 5H-40 X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN REFINERY-1 OPTIMISATION ROOM. CAPACITY- 20 TR; QUANTITY- 2 UNITS; MODEL- 5F40X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN REFINERY-1 SHIFT MANAGER ROOM. CAPACITY- 20 TR; QUANTITY- 1 UNIT; MODEL- 5F40X 1; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN REFINERY-1 FIELD PANEL ROOM. CAPACITY- 66 TR; QUANTITY- 2 UNITS; MODEL- 5H66X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNIT IN LEB CONTROL ROOM. CAPACITY- 86 TR; QUANTITY- 2 UNITS; MODEL- 5H86X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS.

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN REFINERY-2 CONTROL ROOM. CAPACITY- 66, 80 TR; QUANTITY- 2 UNITS; MODEL- 5H-66X 1,KC4 X 1; MAKE- VOLTAS, KIRLOSKAR; UNIT OF MEASUREMENT- MON MONTHS.

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN REFINERY-2 FIRST FLOOR. CAPACITY- 40 TR; QUANTITY- 2 UNITS; MODEL- KC2 X1,5H46 X1; MAKE- KIRLOSKAR, VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN REFINERY-3 GT 1,2 CONTROL ROOM. CAPACITY- 48 TR; QUANTITY- 2 UNITS; MODEL- SMC4100 X 2; MAKE- Axcel; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN REFINERY- 3 SRU CONTROL ROOM. CAPACITY- 46 TR; QUANTITY- 2 UNITS; MODEL- 5H46 X 2; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN TECHNICAL SERVICES BUILDING. CAPACITY- 40 TR; QUANTITY- 1 UNIT; MAKE- KIRLOSKAR; MODEL: AC570 X1 UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN GT4 CONTROL ROOM (SCREW CHILLER). CAPACITY- 90 TR; QUANTITY- 2 UNITS; MAKE- BLUESTAR; MODEL: HANDBELL RC-2-510AX2 UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF CENTRAL AC UNITS IN NEW SRU PLANT (SCREW CHILLER). CAPACITY- 50 TR; MAKE: VOLTAS MODEL: 5H86 X 2 QUANTITY- 2 UNITS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
MAINTENANCE OF PACKAGE AC 2019-21

-

-

-

... More
Charges for maintenance of package AC units for the FIRST YEAR 2019-20. SOR GIVEN BELOW PERTAINS TO EIGHT HOURS OF OPERATION (General Shift Area)

-

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING GROUND FLOOR CAPACITY- 22 TR; QUANTITY- 4 UNITS; MODEL- DPA2642S; MAKE- BLUESTAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING FIRST FLOOR (FRONT). CAPACITY- 5.5 TR; QUANTITY- 1 UNIT; MODEL- DPA2661S; MAKE- BLUESTAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING FIRST FLOOR (FRONT). CAPACITY- 11 TR; QUANTITY- 2 UNITS; MODEL- DPA1322S; MAKE- BLUESTAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING FIRST FLOOR (BACK). CAPACITY- 22 TR; QUANTITY- 2 UNITS; MODEL- DPA2642S; MAKE- BLUESTAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING FIRST FLOOR (BACK). CAPACITY- 16.5 TR; QUANTITY- 1 UNIT; MODEL- DPA1983S; MAKE- BLUESTAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING SECOND FLOOR (BACK). CAPACITY- 17 TR; QUANTITY- 5 UNITS; MODEL- SC211OYMRATU; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING SECOND FLOOR (FRONT). CAPACITY- 11 TR; QUANTITY- 3 UNITS; MODEL- DPUA-SC17OCDMRTU; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN WORKSHOP FIRST FLOOR. CAPACITY- 11 TR; QUANTITY- 2 UNITS; MODEL- DPVASC-110C; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN WORKSHOP GROUND FLOOR. CAPACITY- 11 TR; QUANTITY- 2 UNITS; MODEL- DPVASC-110C; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN NEW CANTEEN. CAPACITY- 22 TR; QUANTITY- 2 UNITS; MODEL- ACDPUASC220CDR407; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN WORKSHOP EXTENSION. CAPACITY- 15 TR; QUANTITY- 1 UNIT; MODEL- 50BAD16; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REFINERY-2 INSTRUMENT MAINTENANCE. CAPACITY- 16.5 TR QUANTITY- 1 UNIT; MODEL- ETA MAKE- ETA UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
Charges for maintenance of package AC units for FIRST YEAR 2019-20. SOR GIVEN BELOW PERTAINS TO 24 HOURS OF OPERATION

-

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN QC LAB FIRST FLOOR. CAPACITY- 22 TR; QUANTITY- 3 UNITS; MODEL- DPA2642 R-1 A , DPA2642 R-2 A MAKE- BLUE STAR UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN IT SERVER ROOM. CAPACITY- 17 TR; QUANTITY- 3 UNITS; MODEL- DPUASC170CD MAKE- VOLTAS. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN CPP/GT3/FPR. CAPACITY- 17 TR; QUANTITY- 2 UNITS; MODEL- PA1600A MAKE- ETA UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN CPP/GT3- DM PLANT. CAPACITY- 8.5 TR; QUANTITY- 3 UNITS; MODEL- DPA1052 R-10 MAKE- BLUESTAR UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN DHDS. CAPACITY- 8.5 TR; QUANTITY- 4 UNITS; MODEL- 50BB008N, DPA105121A MAKE- VOLTAS, BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN OMS CONTROL ROOM. CAPACITY- 22 TR; QUANTITY- 3 UNITS; MODEL- DPUASC220CD,DPA 2642R-2A MAKE- VOLTAS, BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN EURO-IV SRR-1 (RACK AND UPS). CAPACITY- 16.5 TR; QUANTITY- 3 UNITS; MODEL- DPW1983S MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN EURO-IV SRR- 2 RACK ROOM. CAPACITY- 16.5 TR; QUANTITY- 3 UNITS; MODEL- DPW1983S MAKE- BLUESTAR UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN EURO-IV FIRST FLOOR. CAPACITY- 16.5 TR; QUANTITY- 2 UNITS; MODEL- DPW1983S MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN FIRE STATION. CAPACITY- 5.5 TR; QUANTITY- 3 UNITS; MODEL- EADS0066CR MAKE- ETA. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN 110KV YARD RELAY ROOM. CAPACITY- 5.5 TR; QUANTITY- 2 UNITS; MODEL- DSA661R-2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN HGU SUBSTATION. CAPACITY- 11 TR; QUANTITY- 4 UNITS; MODEL- DPAP1322-R2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN HGU FPR AHU1 AND AHU-2. CAPACITY- 44 TR; QUANTITY- 2 UNITS; MODEL- EL342 MAKE- BLUESTAR UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN CO-GEN DM -FPR. CAPACITY- 11 TR; QUANTITY- 2 UNITS; MODEL- DPUASC110R407 MAKE- VOLTAS. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN N2O2 REFINERY-3 INSTRUMENT ANALYSERS ROOM. CAPACITY- 11 TR; QUANTITY- 2 UNITS; MODEL: DPW1322R-1 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REFINERY-2 DCS PANEL. CAPACITY- 11 TR; QUANTITY- 3 UNITS; MODEL- EAP0S132ER MAKE- ETA UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REF-3 GREEN CANTEEN. CAPACITY- 8.5 TR; QUANTITY- 2 UNIT; MODEL- 38LH-100SDR MAKE- CARRIER. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REF-3 GREEN CANTEEN. CAPACITY- 8.5 TR; QUANTITY- 1 UNIT; MODEL- 38LH-100SDR MAKE- CARRIER. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN CISF CONTROL ROOM BUILDING. CAPACITY- 26 TR; QUANTITY- 2 UNITS; MODEL- V-18HACV1180HX004A MAKE- VOLTAS. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN WAX PLANT. CAPACITY- 17 TR; MAKE:VOLTAS MODEL: ACDPUASC170CD QUANTITY- 2 UNITS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MOUNDED BULLET. CAPACITY- 22TR; QUANTITY- 3 UNITS; MAKE: BLUESTAR MODEL: DPA2642 R1A. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN OPH DM PLANT FPR. CAPACITY- 22 TR; QUANTITY- 3 UNITS; MODEL- DPA2642R2A MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN GT-5 FPR, UPS. CAPACITY- 88 TR; QUANTITY- 2 UNIT; MODEL- ACUS2Y090ER2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REF-3 CONTROL ROOM UPS -1. CAPACITY- 8.5 TR; QUANTITY- 6 UNIT; MODEL- DSA1021R2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REF-3 CONTROL ROOM UPS 2. CAPACITY- 8.5 TR; QUANTITY- 3 UNITS; MODEL- DSA1021R2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REF-3 SS2 VFD ROOM. CAPACITY- 8.5 TR; QUANTITY- 1 UNIT; MODEL- DSA1021R2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN OPH BM PLANT UPS ROOM. CAPACITY- 22TR; QUANTITY- 2 UNITS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
Charges for maintenance of package AC units for the SECOND YEAR 2020-21. SOR GIVEN BELOW PERTAINS TO EIGHT HOURS OF OPERATION (General Shift Area)

-

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING GROUND FLOOR. CAPACITY- 22 TR; QUANTITY- 4 UNITS; MODEL- DPA2642S; MAKE- BLUESTAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING FIRST FLOOR (FRONT). CAPACITY- 5.5 TR; QUANTITY- 1 UNIT; MODEL- DPA2661S; MAKE- BLUESTAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING FIRST FLOOR (FRONT). CAPACITY- 11 TR; QUANTITY- 2 UNITS; MODEL- DPA1322S; MAKE- BLUESTAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING FIRST FLOOR (BACK). CAPACITY- 22 TR; QUANTITY- 2 UNITS; MODEL- DPA2642S; MAKE- BLUESTAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING FIRST FLOOR (BACK). CAPACITY- 16.5 TR; QUANTITY- 1 UNIT; MODEL- DPA1983S; MAKE- BLUESTAR; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING SECOND FLOOR (BACK). CAPACITY- 17 TR; QUANTITY- 5 UNITS; MODEL- SC211OYMRATU; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MM BUILDING SECOND FLOOR (FRONT). CAPACITY- 11 TR; QUANTITY- 3 UNITS; MODEL- DPUA-SC17OCDMRTU; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN WORKSHOP FIRST FLOOR. CAPACITY- 11 TR; QUANTITY- 2 UNITS; MODEL- DPVASC-110C; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN WORKSHOP GROUND FLOOR. CAPACITY- 11 TR; QUANTITY- 2 UNITS; MODEL- DPVASC-110C; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN NEW CANTEEN. CAPACITY- 22 TR; QUANTITY- 2 UNITS; MODEL- ACDPUASC220CDR407; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN WORKSHOP EXTENSION. CAPACITY- 15 TR; QUANTITY- 1 UNIT; MODEL- 50BAD16; MAKE- VOLTAS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REFINERY-2 INSTRUMENT MAINTENANCE. CAPACITY- 16.5 TR QUANTITY- 1 UNIT; MODEL- ETA MAKE- ETA. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
Charges for maintenance of package AC units for SECOND YEAR 2020-21 SOR GIVEN BELOW PERTAINS TO 24 HOURS OF OPERATION

-

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN QC LAB FIRST FLOOR. CAPACITY- 22 TR; QUANTITY- 3 UNITS; MODEL- DPA2642 R-1 A , DPA2642 R-2 A MAKE- BLUE STAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN IT SERVER ROOM. CAPACITY- 17 TR; QUANTITY- 3 UNITS; MODEL- DPUASC170CD MAKE- VOLTAS. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN CPP/GT3/FPR. CAPACITY- 17 TR; QUANTITY- 2 UNITS; MODEL- PA1600A MAKE- ETA UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN CPP/GT3- DM PLANT. CAPACITY- 8.5 TR; QUANTITY- 3 UNITS; MODEL- DPA1052 R-10 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN DHDS. CAPACITY- 8.5 TR; QUANTITY- 4 UNITS; MODEL- 50BB008N, DPA105121A MAKE- VOLTAS, BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN OMS CONTROL ROOM. CAPACITY- 22 TR; QUANTITY- 3 UNITS; MODEL- DPUASC220CD,DPA 2642R-2A MAKE- VOLTAS, BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN EURO-IV SRR-1 (RACK AND UPS). CAPACITY- 16.5 TR; QUANTITY- 3 UNITS; MODEL- DPW1983S MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN EURO-IV SRR- 2 RACK ROOM. CAPACITY- 16.5 TR; QUANTITY- 3 UNITS; MODEL- DPW1983S MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN EURO-IV FIRST FLOOR. CAPACITY- 16.5 TR; QUANTITY- 2 UNITS; MODEL- DPW1983S MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN FIRE STATION. CAPACITY- 5.5 TR; QUANTITY- 3 UNITS; MODEL- EADS0066CR MAKE- ETA. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN 110KV YARD RELAY ROOM. CAPACITY- 5.5 TR; QUANTITY- 2 UNITS; MODEL- DSA661R-2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN HGU SUBSTATION. CAPACITY- 11 TR; QUANTITY- 4 UNITS; MODEL- DPAP1322-R2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN HGU FPR AHU1 AND AHU-2. CAPACITY- 44 TR; QUANTITY- 2 UNITS; MODEL- EL342 MAKE- BLUESTAR UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN CO-GEN DM -FPR. CAPACITY- 11 TR; QUANTITY- 2 UNITS; MODEL- DPUASC110R407 MAKE- VOLTAS. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN N2O2 REFINERY-3 INSTRUMENT ANALYSERS ROOM. CAPACITY- 11 TR; QUANTITY- 2 UNITS; MODEL: DPW1322R-1 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REFINERY-2 DCS PANEL. CAPACITY- 11 TR; QUANTITY- 3 UNITS; MODEL- EAP0S132ER MAKE- ETA UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REF-3 GREEN CANTEEN. CAPACITY- 8.5 TR; QUANTITY- 2 UNIT; MODEL- 38LH-100SDR MAKE- CARRIER. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REF-3 GREEN CANTEEN. CAPACITY- 8.5 TR; QUANTITY- 1 UNIT; MODEL- 38LH-100SDR MAKE- CARRIER. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN CISF CONTROL ROOM BUILDING. CAPACITY- 26 TR; QUANTITY- 2 UNITS; MODEL- V-18HACV1180HX004A MAKE- VOLTAS. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN WAX PLANT. CAPACITY- 17 TR; MAKE:VOLTAS MODEL: ACDPUASC170CD QUANTITY- 2 UNITS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN MOUNDED BULLET. CAPACITY- 22TR; QUANTITY- 3 UNITS; MAKE: BLUESTAR MODEL: DPA2642 R1A. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN OPH DM PLANT FPR. CAPACITY- 22 TR; QUANTITY- 3 UNITS; MODEL- DPA2642R2A MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN GT-5 FPR, UPS. CAPACITY- 88 TR; QUANTITY- 2 UNIT; MODEL- ACUS2Y090ER2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REF-3 CONTROL ROOM UPS -1. CAPACITY- 8.5 TR; QUANTITY- 6 UNIT; MODEL- DSA1021R2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REF-3 CONTROL ROOM UPS 2. CAPACITY- 8.5 TR; QUANTITY- 3 UNITS; MODEL- DSA1021R2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN REF-3 SS2 VFD ROOM. CAPACITY- 8.5 TR; QUANTITY- 1 UNIT; MODEL- DSA1021R2 MAKE- BLUESTAR. UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR MAINTENANCE OF PACKAGE AC UNIT IN OPH BM PLANT UPS ROOM. CAPACITY- 22TR; QUANTITY- 2 UNITS; UNIT OF MEASUREMENT- MON MONTHS

12

-

-

... More
CHARGES FOR ITC OF SPARES:

-

-

-

... More
Installation of Chilled water AHU Coil with copper tubes and Aluminium fins - 4 Row Deep Length - 2030 MM X Height - 1640 (2 Coils)  - 2 Set with required valve packages , blank off sheets etc ( Including , OLD AHU Coil Removing & Interconnection to Existing ).- GT#4 area ONLY LABOUR CHARGES

2

-

-

... More
Installation of 18 G GI ducts

100

-

-

... More
Installation of 20 G GI ducts

100

-

-

... More
Installation of 22 G GI ducts

100

-

-

... More
Installation of 24 G GI ducts

100

-

-

... More
Installation of Volume Control Damper

50

-

-

... More
Fixing of Canvass connection

50

-

-

... More
Charges for Insulation of Ducting Only labour charges

100

-

-

... More
Fixing of Powder coated Supply Air Grill with MS collar Damper

50

-

-

... More
Fixing of Powder coated Return Air Grill without MS collar Damper

50

-

-

... More
Fixing of acuostic materails ( 50 MM ) fiber glass wool covered with RP tissue & 28 aluminium perforated sheet for AHU room of CAC, PAK unit area

100

-

-

... More
Fixing of Under Deck insulation with 50 mm thick thermocol materials

100

-

-

... More
Carrying out Robotic cleaning of Airducts after inspection of ducts, report submissions

500

-

-

... More
Carrying out wall opening jobs of 4 inches size to lay to indoor to outdoor copper line, drain line, power cable in required during spare ac fixing jobs

10

-

-

... More
Replacement of corroded Base Frames of CW / Chilled water Booster pumps , Compressors, motors , AHU 's and their support fabrication in central , package plants

1000

-

-

... More
Socket welding -carbon steel above ground piping- socket/ fillet welding joint -without hydrotest

100

-

-

... More
Butt Welding- Carbon steel above ground piping- Butt welding joint -upto 8.8 mm thickness ,without hydrotest (Root E-6010/ Filling E6013/ E- 7018) UNIT OF MEASUREMENT- ID INCHDIA

100

-

-

... More
Replacement of Faulty all capacities existing capacity Compressors of package ac plants by performing leak testing, vaccumizing, gas charging, , commissioning, submission of reports & disposing of faulty compressor to CPCL scrap yard

20

-

-

... More
Replacement of Faulty all types of existing capacity of Mono block pumps along in central/ package ac plants by performing leak testing, commissioning, submission of reports & disposing of faulty pumps to CPCL scrap yard

8

-

-

... More
Replacement of Faulty Expansion valves in central plants ac plants by performing leak testing, commissioning, submission of reports & disposing of faulty expansion valve to CPCL scrap yard

35

-

-

... More
Replacement of Faulty Indoor air units in Package ac plants by performing leak testing, commissioning, submission of reports & disposing of faulty indoor units to CPCL scrap yard

9

-

-

... More
Replacement of Faulty Outdoor air cooled condenser unit in Package ac plants by performing leak testing, commissioning, submission of reports & disposing of faulty indoor coil to CPCL scrap yard

24

-

-

... More
Supply of Chilled water AHU Coil with copper tubes and Aluminium fins - 4 Row Deep Length - 2030 MM X Height - 1640 (2 Coils)  - 2 Set with required water & gas valve packages , blank off sheets etc.- GT#4 area.

2

-

-

... More
DUCTING 18GI

100

-

-

... More
DUCTING, 20GI

100

-

-

... More
DUCTING, 22GI

100

-

-

... More
DUCTING, 24GI

100

-

-

... More
VOLUME CONTROL DAMPER

50

-

-

... More
CANVASS CONNECTION FOR AIR DUCTS

50

-

-

... More
POWDER COATED SUPPLY AIR GRILL

50

-

-

... More
POWDER COATED RETURN AIR GRILL

50

-

-

... More
ACUOSTIC MATERIALS(50 MM)FIBER GLASSWOOL

100

-

-

... More
UNDERDECK INSULATION+ 50MM THK THERMOCOL

100

-

-

... More
MOTOR FOR PACKAGE UNIT 5.5 TR-0.5HP

5

-

-

... More
MOTOR FOR PACKAGE UNIT 8.5TR-0.5HP

5

-

-

... More
MOTOR FOR PACKAGE UNIT 11 TR-0.5HP

5

-

-

... More
BLOWER MOTOR FOR PKG UNITINDOOR 5.5TR1HP

5

-

-

... More
BLOWER MOTOR FOR PKG UNITINDOOR 8.5TR1.5

5

-

-

... More
BLOWER MOTOR FOR PKG UNIT INDOOR 11TR2HP

5

-

-

... More
FAN MOTOR FOR CENTRAL PLANT CT 7.5KW

2

-

-

... More
FAN MOTOR FOR CENTRAL PLANT CT 5.5KW

2

-

-

... More
FAN MOTOR FOR CENTRAL PLANT CT 3KW

2

-

-

... More
BLOWER MOTOR CENTRAL PLANT AHU 15KW

2

-

-

... More
BLOWER MOTOR CENTRAL PLANT AHU 7.5KW

2

-

-

... More
BLOWER MOTOR CENTRAL PLANT AHU 5.5KW

2

-

-

... More
BLOWER MOTOR CENTRAL PLANT AHU 3KW

2

-

-

... More
Supply of Package unit Outdoor air cooled condenser unit without compressor Suitable of Existing units make - ETA, Bluestar, Voltas 5.5TR

8

-

-

... More
Supply of Package unit Outdoor air cooled condenser unit without compressor Suitable of Existing units make - ETA, Bluestar, Voltas 8.5TR

8

-

-

... More
Supply of Package unit Outdoor air cooled condenser unit without compressor Suitable of Existing units make - ETA, Bluestar, Voltas 11 TR

8

-

-

... More
EXPANSION VALVE-AA5HV100

5

-

-

... More
EXPANSION VALVE-AAE8HV100

5

-

-

... More
EXPANSION VALVE-TDX11TR

5

-

-

... More
EXPANSION VALVE-HVE11

5

-

-

... More
EXPANSION VALVE-HVE16

5

-

-

... More
EXPANSION VALVE-HVE20

5

-

-

... More
EXPANSION VALVE-MVE26

2

-

-

... More
EXPANSION VALVE-MVE40

2

-

-

... More
Supply of Floor Mounted INDOOR PACKAGE AC SINGLE UNIT with SCROLL COMPRESSOR , R-407 C GAS with required indoor to outdoor copper pipes, cable, drain line( Average distance-10 meters). Suitable of existing units make - - Bluestar, voltas, carrier,ETA - 22 TR ( 2*11) -8800 CFM.

3

-

-

... More
Supply of Floor Mounted INDOOR PACKAGE AC SINGLE UNIT with SCROLL COMPRESSOR , R-407 C GAS with required indoor to outdoor copper pipes, cable, drain line( Average distance-10 meters). Suitable of existing units make - - Bluestar, voltas, carrier,ETA - 17 TR (2*8.5 ) - 6800 CFM.

3

-

-

... More
Supply of Floor Mounted INDOOR PACKAGE AC SINGLE UNIT with SCROLL COMPRESSOR , R-407 C GAS with required indoor to outdoor copper pipes, cable, drain line( Average distance-10 meters). Suitable of existing units make - - Bluestar, voltas, carrier,ETA- 11 TR ( 2*5.5 ) - 4400 CFM.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.