Chennai Metropolitan Water Supply And Sewerage Board Tender
... More
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Chennai Metropolitan Water Supply And Sewerage Board - CMWSSB Tender
Civil And Construction
Drainage Work
Eprocure
Opening Date2 Dec 2022
Closing Date3 Jan 2023
Tender Amount₹ 7,94,46,362 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 4,43,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Cnt/sew/ncb/amrut 2 Singara Chennai 2/007/22-23
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_CMWSS_269743_1Bid Award Id
ViewTender No
CNT/SEW/NCB/AMRUT2.0 Singara Chennai 2.0/007/22-23Tender Authority
Chennai Metropolitan Water Supply And Sewerage Board ViewPurchaser Address
-Website
http://https://chennaimetrowater.tn.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Labour for cutting open road for laying water mains or sewer - concrete roads
292.6
-
-
... More
Providing Iron Barricading of size 2.50 m width and 1.75 m height using 40x40x4 mm angle for outer frame supports, 25 x 25 x 3 mm angle for inner rame supports and 20 gauge thickness MS sheet for name board (as per drawing) including cutting, welding, fabrication charges and one coat of primer and 2 coats of enamel paint of approved quality, writing "METRO WATER" & work detail/ caution sign, providing necessary interlocking arrangements with adjoining units, fixing danger flags, danger lights, reflectors, fixing stickers etc, including watching during night and placing the barricading units as directed at the sites
3296
-
-
... More
Hire charges for diesel pump sets to divert sewer flow including cost of fuel and machinist for running the machine
-
-
-
... More
5 HP
8848
-
-
... More
7.5 HP
11360
-
-
... More
10 HP
7424
-
-
... More
Removal of existing RCC pipe and disposal of RCC pipes upto 10 km lead
-
-
-
... More
450 mm dia
806
-
-
... More
500 mm dia
658
-
-
... More
Carting of excavated earth from site to stacking yard up to 10 km lead
422.97
-
-
... More
Carting of excavated earth from stacking yard to site for refilling up to 10 km lead
436.98
-
-
... More
Supply of stone dust for filling
13.89
-
-
... More
Supplying, laying, jointing (with rubber gaskets) and testing of C.I. pipes including earthwork excavation for trenches in hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil, depositing the earth on banks with initial lead of 10m. and carting of pipes, lowering into trenches and aligning, refilling the trenches with excavated soil, watering and ramming to consolidation, disposal of surplus earth etc., complete (Timbering included for Depths 2.50m,3.0m,3.5m,..........upto 8.5m) (Including backfilling trenches and disposal of surplus earth) including backfilling of trenches and disposal of surplus earth
-
-
-
... More
400mm dia at 2.0m depth
64
-
-
... More
400mm dia at 2.5m depth
80
-
-
... More
400mm dia at 3.0m depth
48
-
-
... More
400mm dia at 3.5m depth
63
-
-
... More
400mm dia at 4.0m depth
242
-
-
... More
500mm dia at 3.5m depth
181
-
-
... More
500mm dia at 4.0m depth
227
-
-
... More
500mm dia at 4.5m depth
292
-
-
... More
500mm dia at 5.0m depth
47
-
-
... More
600mm dia at 4.5m depth
190
-
-
... More
700mm dia at 4.0m depth
30
-
-
... More
Reaming 300mm dia pilot bore to 400mm / 450mm bore as per site condition as directed by Engineer Incharge at site Upto 60m depth ending below ground level
288
-
-
... More
Provision for sub-soil dewatering using Filter point method for depth 5.0m and above
-
-
-
... More
Boring 150mm dia upto hard formation and boring 115mm dia below this in rock formation and inserting 125mm nominal dia PVC (140 mm OD) as per IS 12818/1992 casing pipe upto hard formation. The entire column to be cleaned at site as directed, including hire charges for the power rig for drilling the bores as directed above both upto hard formation and then in rock formation (including the cost of fuel charges, transporting to and from the power rig, etc., complete.) including flushing the bore using compressor,providing danger lights during night time, etc., complete.
288
-
-
... More
Reaming from 140/150mm dia pilot bore to 300mm dia bore as directed by the CMWSS Board Officers upto 60m Depth ending from ground level.
288
-
-
... More
Hire charges for diesel pumpset for 3 HP with fuel and crew charges
including transportation
705
-
-
... More
Cutting of CI main (Labour charges only)
-
-
-
... More
400 mm dia
30
-
-
... More
500 mm dia
50
-
-
... More
600 mm dia
10
-
-
... More
700 mm dia
2
-
-
... More
Cement concrete 1:3:6 using crushed stone sand (M-saned) and 40mm gauge hard broken stone jelly for PCC works including laying in layers of not more than 15cm thick,compacting, curing etc complete for encasing and end concrete.
31
-
-
... More
Rectification of damaged House Service Connection - Water -Supplying and laying of 20mm dia MDPE (PE80) Blue pipe (IS:4427) with necessary specials including earth work excavation laying jointing testing, refilling the trenches and disposal of surplus earth including Supply of PVC Couplers (Mould) BIS 7834/1975 Part VI, Boring and Tapping mains or Re- Boring and Tapping main and fixing brass screw plugs or ferrules of sizes etc.
348
-
-
... More
Providing and fixing dummies of the following size at 3.0-7.5m depth using diver with helmet with all safety measures including insurance cover for the diver and labours at various depths
-
-
-
... More
upto 400 mm dia
26
-
-
... More
450 mm dia
52
-
-
... More
500 mm dia
40
-
-
... More
Dismantling and removing dummies of following size at 3.0-7.5m depth using diver with helmet with all safety measures including insurance cover for the diver and labours at various depths
-
-
-
... More
upto 400 mm dia
26
-
-
... More
450 mm dia
52
-
-
... More
500 mm dia
40
-
-
... More
Insertion of machine holes -Construction of RCC manholes using sulphate resistant cement with M30 design mix concrete using Crushed stone sand (M sand) including earthwork excavation as per SS20B , providing point edge to well kerb using ISA 150x75x10mm weighing at 16.9kg/m,sinking well kerb below 2m from G.L.or by open excavation for various depth as per site condition with M30 mix for side wall, raft and roof slab,including cost of steel reinforcement ,including bailing and pumping out water, formwork, plugging the bottom with PCC 1:3:6 using 40mm hard broken granite jelly, laying plain cement concrete 1:3:6 using 12mm to 20mm hard broken granite jelly for fixing frame, fixing FRC manhole cover and frame, providing CI steps, ,benching and channelling including refilling the trenches with excavated earth and disposal of earth etc. Including testing the manhole with water for 48hours to check water tightness and rectifying the defects if any complete for the following size of machine holes.
-
-
-
... More
Upto 450 mm dia sewer pipe - Machine hole size 1.2m dia
-
-
-
... More
2.0 m depth (precast)
2
-
-
... More
2.5 m depth
2
-
-
... More
3.5 m depth
1
-
-
... More
4.0 m depth
6
-
-
... More
500 mm dia and above sewer pipe - Machine hole size 1.5m dia
-
-
-
... More
3.5 m depth
2
-
-
... More
4.0 m depth
2
-
-
... More
4.5 m depth
7
-
-
... More
Raising of 45 cm (18”) or 60 cm (24”) dia cast iron manhole frame and door using brick work in C.M. 1:3, grouting with C.C.1:2:4 using 20mm B.G. jelly rendering the top surface smooth with cement etc. complete for 1 Machine hole. -upto 30cm
40
-
-
... More
Supply of FRC 60 cm door and Frame heavy duty
40
-
-
... More
Supplying and fixing 150mm dia MS pipe ventilating column 6 m length with C.I.Base for Ventilating Column, Wire Cowl, Supplying, Laying, Jointing and Testing of 150mm dia Stoneware Pipe to a length of 6m for each column with 100mm S.W. stopper including cost of jointing materials such as cement, sand and spun yarn with necessary civil works for construction of Masonry Pillars, Earthwork excavation, refilling etc., complete.
4
-
-
... More
Lighting arrangements (maintenance works ) with genset: Hire charges for portable Genset 1.00 KVA with 2 Nos. of 150W flood light including all incidental charges, transportation, crew charges and fuel charges etc., complete.
404
-
-
... More
Disjointing and relaying DI main of various sizes including cutting of CI/DI mains and Supply and fixing of MJ Collars (Including stacking and storing the material at safe location for relaying)
-
-
-
... More
100 mm dia Pipe
431
-
-
... More
150 mm dia pipe
68
-
-
... More
200 mm dia pipe
219
-
-
... More
300 mm dia pipe
609
-
-
... More
Supply of HDPE pipes & specials of class PN6 and Lowering HDPE pipes and specials to trench and laying to proper alignment for depth upto 2.0m and removing - for temporary supply of water
-
-
-
... More
100 mm dia Pipe
431
-
-
... More
150 mm dia pipe
68
-
-
... More
200 mm dia pipe
219
-
-
... More
Replacing the existing damaged stoneware sewer main by Supplying salt glazed stoneware pipes as per IS 651-2007 of 0.6m length and laying, jointing SW pipes with cement joint, testing including earthwork excavation and laying SW pipe at various size and depths and Cement concrete 1:2:4 using Crushed stone sand (Msand) and 20mm gauge hard broken stone jelly for plain concrete works including laying ramming curing, etc.complete., End concrete
-
-
-
... More
200mm dia at 1.5m depth
26
-
-
... More
200mm dia at 2.0m depth
26
-
-
... More
200mm dia at 2.5m depth
26
-
-
... More
300mm dia at 1.5m depth
26
-
-
... More
300mm dia at 2.0m depth
26
-
-
... More
300mm dia at 2.5m depth
26
-
-
... More
Rectification of culvert crossing - Cement concrete 1:4:8 using Crushed stone sand (Msand) and 40mm gauge hard broken stone jelly for Plain cement concrete works including laying in layers of not more than 15cm thick including ramming, curing, etc. complete for Base Concrete; Cement concrete 1:1 ½:3 using Crushed stone sand (Msand) and 20mm gauge hard broken stone jelly for reinforced cement concrete works including cost of steel, centering, shuttering and cost of steel reinforcement, laying in position,compacting, curing, finishing, etc., complete for Raft slab, Wall concrete, Cover Slab and Including supply and fixing of FRC 60 cm door and Frame heavy duty including disposal of debris and finishing to gradient
10
-
-
... More
Rectification of Stormwater drain - Cement concrete 1:4:8 using Crushed stone sand (Msand) and 40mm gauge hard broken stone jelly for Plain cement concrete works including laying in layers of not more than 15cm thick including ramming, curing, etc. complete for Base Concrete; Cement concrete 1:1 ½:3 using Crushed stone sand (Msand) and 20mm gauge hard broken stone jelly for reinforced cement concrete works including cost of steel, centering, shuttering and cost of steel reinforcement, laying in position,compacting, curing, finishing, etc., complete for Raft slab, Wall concrete, Cover Slab and Including supply and fixing of FRC 60 cm door and Frame heavy duty including disposal of debris and finishing to gradient
140
-
-
... More
Replacing the existing 200mm stoneware sewer main by laying 250mm DWC pipe at 2m depth - Supply and Delivery and Laying of DWC Structured Wall Polyethylene Piping Systems (Pipe with online/offline coupler and elastomeric sealing ring) with required specials non-smooth external annular corrugated and smooth internal surface (Double wall) (SN 8 Class) for non-pressure underground sewerage, drainage application generally as per IS-16098 (Part-2) type B. including refilling and disposal of surplus earth
1853
-
-
... More
Providing New House Sewer Service Connections - Supply and laying of 6 KSC PVC rigid pipes and specials to trench and laying to proper grade and alignment, jointing with PVC couplers with cement paste.
-
-
-
... More
For sewer-110mm dia PVC pipe
122
-
-
... More
For sewer-140mm dia PVC pipe
47
-
-
... More
For interior plastering of circular Machine hole - Plastering with cement mortar1:3 (SRC) (Crushedstonesand (M-sand)) for 12mm thick including curing,etc., complete at various depths including benching and channelling wherever required
-
-
-
... More
upto 3m depth
56.4
-
-
... More
At 3.5 m depth
34.05
-
-
... More
At 4.0 m depth
108
-
-
... More
At 4.5 m depth
109.55
-
-
... More
At 7.0 m depth
74.88
-
-
... More
For exterior plastering of circular Machine hole - Plastering with cement mortar1:3 (SRC) (Crushedstonesand (M-sand)) for 20mm thick including curing,etc., complete at various depths
-
-
-
... More
upto 3m depth
96
-
-
... More
At 3.5 m depth
57.15
-
-
... More
At 4.0 m depth
177.2
-
-
... More
At 4.5 m depth
180.25
-
-
... More
At 7.0 m depth
121.05
-
-
... More
Bill No 2. ESTIMATE OF PUMPING MAIN - Rerouting of sewer pumping main of Meenambakkam collection from MKN road to Kannan Colony Lift station
-
-
-
... More
Cutting of asphaltic road surface - Bus Route
720
-
-
... More
Providing Iron Barricading of size 2.50 m width and 1.75 m height using 40x40x4 mm angle for outer frame supports, 25 x 25 x 3 mm angle for inner frame supports and 20 gauge thickness MS sheet for name board (as per drawing) including cutting, welding, fabrication charges and one coat of primer and 2 coats of enamel paint of approved quality, writing "METRO WATER" & work detail/ caution sign, providing necessary interlocking arrangements with adjoining units, fixing danger flags, danger lights, reflectors, fixing stickers etc, including watching during night and placing the barricading units as directed at the sites
720
-
-
... More
Supply, delivery and laying C.I. Pipes LA Class of the following sizes of socket @ spigot end in standard lengths conforming to thelatest revisionof IS 1536 withISI marking on it. including Labour charges for loading, unloading and stacking at the site etc., including earthwork excavation for trenches in hard stiff clay, blackcotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil depositing the earth on banks with initial lead of 10m and initial lift of 2m conveying to the site of work, lowering into the trenches, and aligning, jointing, refilling the trenches with excavated soil, watering and ramming to consolidation, disposal of surplus earth etc., complete for the pipes of following diametres at the following depths.
-
-
-
... More
250mm dia at a depth of 2m depth
720
-
-
... More
Supply, delivery, conveying and fixing following sizes of CI specials as mentioned below conforming to the latest revision of IS 1536 with ISI marking on it including loading, unloading and stacking at the site etc as directed by the engineer at site, and including earthwork excavation, refilling with excavated soil, watering and ramming to consolidation and disposal of surplus earth etc complete.
-
-
-
... More
Bends
-
-
-
... More
250mm d/soc 45 deg bend
8
-
-
... More
250mm d/soc 90 deg bend
20
-
-
... More
250mm dia MJ collar
25
-
-
... More
Specials for Air valves
-
-
-
... More
250x250x80 D.Soc./Fl. Tee
1
-
-
... More
80mm dia Cut Pipe
1
-
-
... More
Specials for Discharge Chamber
-
-
-
... More
250mm dia D/f duckfoot bend
1
-
-
... More
250mm dia D/f pipe-0.5m long
2
-
-
... More
250mm dia D/f pipe-1.0m long
2
-
-
... More
250mm dia 90 deg D/F bend
2
-
-
... More
250mm dia CI bell mouth
1
-
-
... More
Specials for Valve
-
-
-
... More
250mm dia Spigot tail piece
2
-
-
... More
250mm dia socket tail piece
2
-
-
... More
Making rubber jonts for CI pipes- Labour only
-
-
-
... More
250 mm
244
-
-
... More
80 mm
4
-
-
... More
Construction of Thrust Blocks using cement concrete 1:3:6, 40mm BG jelly for plain cement concrete.
-
-
-
... More
90 degree
23
-
-
... More
45 degree
8
-
-
... More
Supplying and delivery at site, conveying and fixing of CI double air valves including loading, unloading and stacking at site etc as directed by the engineer at site etc complete as per specifications.
-
-
-
... More
80mm CI Double air valve
1
-
-
... More
Cutting of CI Pipes true to axis and finishing the ends complete.
-
-
-
... More
250mm
40
-
-
... More
Construction of 80mm dia Double air valve chamber for 100mm to 350mm dia pipeline inluding providng and fixing FRC cover and frame of size 60 x 60cm for size 1.20 x 0.9 x 1.8 m
1
-
-
... More
Testing of CI pipes with hydraulic testing equipment by filling with water ( including cost of Water) and testing to recommended pressure in convenient stretches and attending the bursts if any occurred during the test, excluding the cost of pipes, including other incidental and operational charges, etc., complete for the following diametres of pipes.
-
-
-
... More
250mm
720
-
-
... More
Supply of CI D/F Sluice valve with cap/ wheel as per IS 14846/2000 PN 1 with ISI marking
-
-
-
... More
250mm dia
2
-
-
... More
Conveying and fixing sluice valves with tail pieces including fixing the surface boxes/valves, covers.
2
-
-
... More
Construction of chamber for 100mm to 250mm dia. Sluice valve including providing and fixing FRC cover and frame of size 60 x 60cm for size1.35x1.2x 1.55 m
2
-
-
... More
Rectification of culvert crossing - Cement concrete 1:4:8 using Crushed stone sand (Msand) and 40mm gauge hard broken stone jelly for Plain cement concrete works including laying in layers of not more than 15cm thick including ramming, curing, etc. complete for Base Concrete; Cement concrete 1:1 ½:3 using Crushed stone sand (Msand) and 20mm gauge hard broken stone jelly for reinforced cement concrete works including cost of steel, centering, shuttering and cost of steel reinforcement, laying in position,compacting, curing, finishing, etc., complete for Raft slab, Wall concrete, Cover Slab and Including supply and fixing of FRC 60 cm door and Frame heavy duty including disposal of debris and finishing to gradient
2
-
-
... More
Rectification of Stormwater drain - Cement concrete 1:4:8 using Crushed stone sand (Msand) and 40mm gauge hard broken stone jelly for Plain cement concrete works including laying in layers of not more than 15cm thick including ramming, curing, etc. complete for Base Concrete; Cement concrete 1:1 ½:3 using Crushed stone sand (Msand) and 20mm gauge hard broken stone jelly for reinforced cement concrete works including cost of steel, centering, shuttering and cost of steel reinforcement, laying in position,compacting, curing, finishing, etc., complete for Raft slab, Wall concrete, Cover Slab and Including supply and fixing of FRC 60 cm door and Frame heavy duty including disposal of debris and finishing to gradient
25
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements