Chennai Metropolitan Water Supply And Sewerage Board Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Chennai Metropolitan Water Supply And Sewerage Board - CMWSSB Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date3 Jan 2024
Closing Date23 Jan 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
a) 150 mm Ø Pipes at 2m depth

130

329914

2537.8

... More
6) 100 mm Ø Pipes at 2m depth

12

23048

1920.7

... More
Barrication work along one side of the trench for laying the pipe line with casurina post 1.52m centre to centre (8 to 10 cm dia. And 1.52m height) verticals, painting the verticals, painting the vertical posts in different colours, tieing with coir rope, fixing danger flags, danger lights, reflectors including watching during night for 1metre.

284

23572

83

... More
Supplying of specials

-

-

-

... More
a) 150 mm dia M.J Collar

4

17908

4477

... More
b) 150 x 100 mm taper

1

1520

1520.2

... More
c) 150 mm 90 degree bend

2

4975

2487.6

... More
d) 150 mm 22 1/2 degree bend

1

1796

1796.6

... More
e) 150 mm dia Sluice valve

1

9634

9634

... More
f) 150 mm dia DI Spi. Flange tail piece

1

2431

2431

... More
g) 150 mm dia DI Soc. Flange tail piece

1

2002

2002

... More
h) 100 mm dia Sluice valve

1

6510

6510

... More
i) 100 mm dia DI Spi. Flange tail piece

1

1573

1573

... More
j) 100 mm dia DI Soc. Flange tail piece

1

1287

1287

... More
k) 100 mm dia MJ Collars

1

2815

2815

... More
l) 150 mm dia EDPM Rubber Gasket

22

3334

151.58

... More
m) 100 mm dia EDPM Rubber Gasket

2

214

107.06

... More
Conveying and fixing specials

-

-

-

... More
a) 150 mm dia M.J Collar

4

1360

340

... More
b) 150 x 100 mm taper

1

693

693

... More
c) 150 mm 90 degree bend

2

1386

693

... More
d) 150 mm 22 1/2 degree bend

1

693

693

... More
e) 150 mm dia Sluice valve

1

959

959

... More
f) 150 mm dia DI Spi. Flange tail piece

1

340

340

... More
g) 150 mm dia DI Soc. Flange tail piece

1

340

340

... More
h) 100 mm dia Sluice valve

1

869

869

... More
i) 100 mm dia DI Spi. Flange tail piece

1

268

268

... More
j) 100 mm dia DI Soc. Flange tail piece

1

268

268

... More
k) 100 mm dia MJ Collars

1

268

268

... More
Cutting D.I. mains - Labour only

-

-

-

... More
a)150 mm Ø Pipes

15

4620

308

... More
b)100 mm Ø Pipes

2

462

231

... More
Making Rubber joints - Labour only

-

-

-

... More
a)150 mm Ø Pipes

22

5764

262

... More
b)100 mm Ø Pipes

2

374

187

... More
Construction of thrust blocks using Cement Concrete 1:3:6 ,40mm B.G.jelly for Plain Cement Concrete for

-

-

-

... More
a) 150 mm Ø 90 degree bend

2

17020

8510

... More
c) 150 mm Ø 22 1/2 degree bend

1

3290

3290

... More
Connection work to existing main including cutting existing pipe, fixing branches, collars, lead jointing and bailing out water, etc., excluding excavation.

-

-

-

... More
Interconnection from existing 450mm DI water main to 150mm DI water main

1

20041

20041

... More
Hire charges for diesel pumpset above 3HP to 7.5HP with fuel and operator charges including transportation.

240

76644

319.35

... More
Testing of D.I.pipes with hydrulic testing equipment by fillling with water (including cost of water @ Rs.77/KL) and testing to recommended pressure in convenient sretches and attending the bursts if any occurred during the test, excluding the cost of pipes, including other incidental and operational charges,etc., complete.

-

-

-

... More
a) 150mm Ø Pipes

130

15730

121

... More
b) 100mm Ø Pipes

12

1092

91

... More
Construction of chamber for 100mm to 250mm dia. sluice valve including providing and fixing FRC cover and frame of size 60 x 60cm for size 1.35 x 1.2 x 1.55 m

3

168000

56000

... More
Earthwork excavation and deposting on bank with initial lead of 10 meteres and initial lift 2.00m in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel, stoney earth and earth mixed with small size boulders S.S. 20-B.(excluding timbering and bailing out sub-soil water) as per P.W.D. standard schedule of rates for chennai city for IC work.

10

2338

233.8

... More
Supplying, laying jointing and testing 100mm dia SW pipe including earthwork excavation for trenches in hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil, depositing the earth on banks with initial lead of 10m. lowering the pipes into the trenches, aligning,refilling the trenches with excavated earth in layers of not more than 23cm thick watering, ramming to consolidation and disposal of surplus earth etc., complete at an average depth of 2.0m. For damaging the House Service Connection

5

3555

711

... More
Providing Wet mix macadam including premixing the material with water at OMC in mechanical mix plant carriage and laying in uniform layers and compacting etc.Complete as per clause 406 of MORT&H specifications

21.3

51326

2409.7

... More
Cement concrete 1:2:4 using Crushed stone sand (M sand) and 12 to 20mm gauge hard broken stone jelly for plain concrete work including laying compacting curing, etc., complete.

15.98

101808

6371

... More
Disposal of surplus excavated earth

37.28

5433

145.75

... More
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type,microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing.

1

100345

100345

... More
The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished.

-

-

-

... More
Sub Total

1

-

10

... More
GST @ 18%

1

204580

10



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.