Chennai Metropolitan Water Supply And Sewerage Board Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Chennai Metropolitan Water Supply And Sewerage Board - CMWSSB Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date13 Mar 2024
Closing Date3 Jul 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Cnt/wss/icb/jica/desal/ Cp2/022/2023-24construction, Testing And Commissioning Of Reservoir At Porur And Pumping Stations, Ancillary Works At Perur And Porur Including Operation And Maintenance (o Andm) For Twenty (20) Years.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stony earth and earth mixed with small size boulders as per SS 20B with initial lead of 10m and lift of 2.0metc. complete.

-

-

-

... More
0 – 2m

-

-

-

... More
IN INR

4049

-

-

... More
IN USD

4049

-

-

... More
IN JPY

4049

-

-

... More
Extra for every additional one-meter lift or part thereof over initial liftetc. complete.

-

-

-

... More
2 – 3m

-

-

-

... More
IN INR

1725

-

-

... More
IN USD

1725

-

-

... More
IN JPY

1725

-

-

... More
3 – 4m

-

-

-

... More
IN INR

1725

-

-

... More
IN USD

1725

-

-

... More
IN JPY

1725

-

-

... More
4 – 5m

-

-

-

... More
IN INR

1725

-

-

... More
IN USD

1725

-

-

... More
IN JPY

1725

-

-

... More
5 – 6m

-

-

-

... More
IN INR

1725

-

-

... More
IN USD

1725

-

-

... More
IN JPY

1725

-

-

... More
6 – 7m

-

-

-

... More
IN INR

1665

-

-

... More
IN USD

1665

-

-

... More
IN JPY

1665

-

-

... More
7 – 8m

-

-

-

... More
IN INR

1475

-

-

... More
IN USD

1475

-

-

... More
IN JPY

1475

-

-

... More
8 – 9m

-

-

-

... More
IN INR

580

-

-

... More
IN USD

580

-

-

... More
IN JPY

580

-

-

... More
Driving sheet piles for one meter length of gallery each side in sandy soil.

-

-

-

... More
0 – 2m

-

-

-

... More
IN INR

165

-

-

... More
IN USD

165

-

-

... More
IN JPY

165

-

-

... More
2 – 4m

-

-

-

... More
IN INR

165

-

-

... More
IN USD

165

-

-

... More
IN JPY

165

-

-

... More
4 – 6m

-

-

-

... More
IN INR

165

-

-

... More
IN USD

165

-

-

... More
IN JPY

165

-

-

... More
6 – 8m

-

-

-

... More
IN INR

165

-

-

... More
IN USD

165

-

-

... More
IN JPY

165

-

-

... More
8 – 10m

-

-

-

... More
IN INR

165

-

-

... More
IN USD

165

-

-

... More
IN JPY

165

-

-

... More
Removing sheet piles from one meter length of gallery on each side including stacking the sheet piles properly.

-

-

-

... More
0 – 2 m

-

-

-

... More
IN INR

165

-

-

... More
IN USD

165

-

-

... More
IN JPY

165

-

-

... More
2 – 4 m

-

-

-

... More
IN INR

165

-

-

... More
IN USD

165

-

-

... More
IN JPY

165

-

-

... More
4 – 6 m

-

-

-

... More
IN INR

165

-

-

... More
IN USD

165

-

-

... More
IN JPY

165

-

-

... More
6 – 8 m

-

-

-

... More
IN INR

165

-

-

... More
IN USD

165

-

-

... More
IN JPY

165

-

-

... More
8 – 10 m

-

-

-

... More
IN INR

165

-

-

... More
IN USD

165

-

-

... More
IN JPY

165

-

-

... More
Refilling with excavated soil (other than sand) complying with standard specifications for filling in foundations and basement.

-

-

-

... More
IN INR

2102

-

-

... More
IN USD

2102

-

-

... More
IN JPY

2102

-

-

... More
Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.

-

-

-

... More
IN INR

12568

-

-

... More
IN USD

12568

-

-

... More
IN JPY

12568

-

-

... More
CONCRETE AND ALLIED WORKS 

-

-

-

... More
Cement concrete 1:2:4 (M15) using Crushed stone sand (M sand) and 12 to 20 mm gauge hard broken stone jelly for plain concrete work including laying, compacting, curing, etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 1.5 m depth

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
1.5 – 4.5 m depth

-

-

-

... More
IN INR

21

-

-

... More
IN USD

21

-

-

... More
IN JPY

21

-

-

... More
4.5 - 9.0 m depth

-

-

-

... More
IN INR

149

-

-

... More
IN USD

149

-

-

... More
IN JPY

149

-

-

... More
Above GL

-

-

-

... More
0 - 1.5 m height

-

-

-

... More
IN INR

18

-

-

... More
IN USD

18

-

-

... More
IN JPY

18

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade for reinforced cement concrete using SRC/OPC (43 grade) for structural elements under controlled water cement ratio with plasticizer using 20mm and downgraded machine broken granite stone jelly excluding the cost of Centering and shuttering and reinforcement, but including curing, fixing, fan clamps, as per standard specification etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 1.5 m depth

-

-

-

... More
IN INR

99

-

-

... More
IN USD

99

-

-

... More
IN JPY

99

-

-

... More
1.5 – 4.5 m depth

-

-

-

... More
IN INR

328

-

-

... More
IN USD

328

-

-

... More
IN JPY

328

-

-

... More
4.5 - 9.0 m depth

-

-

-

... More
IN INR

2372

-

-

... More
IN USD

2372

-

-

... More
IN JPY

2372

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

480

-

-

... More
IN USD

480

-

-

... More
IN JPY

480

-

-

... More
4.5 - 9.0 m height

-

-

-

... More
IN INR

537

-

-

... More
IN USD

537

-

-

... More
IN JPY

537

-

-

... More
FORM WORK 

-

-

-

... More
Providing form work with Centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting for raft, wall, beam, slab, column & stair, etc. complete.

-

-

-

... More
Above GL

-

-

-

... More
0 – 3 m

-

-

-

... More
IN INR

7748

-

-

... More
IN USD

7748

-

-

... More
IN JPY

7748

-

-

... More
3 - 4 m

-

-

-

... More
IN INR

172

-

-

... More
IN USD

172

-

-

... More
IN JPY

172

-

-

... More
4 - 5 m

-

-

-

... More
IN INR

173

-

-

... More
IN USD

173

-

-

... More
IN JPY

173

-

-

... More
5 – 6 m

-

-

-

... More
IN INR

2153

-

-

... More
IN USD

2153

-

-

... More
IN JPY

2153

-

-

... More
6 – 7 m

-

-

-

... More
IN INR

471

-

-

... More
IN USD

471

-

-

... More
IN JPY

471

-

-

... More
7 – 8 m

-

-

-

... More
IN INR

1385

-

-

... More
IN USD

1385

-

-

... More
IN JPY

1385

-

-

... More
PILING WORK

-

-

-

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M30 using SRC/OPC (43 grade) of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).

-

-

-

... More
600 mm dia. Piles

-

-

-

... More
IN INR

3040

-

-

... More
IN USD

3040

-

-

... More
IN JPY

3040

-

-

... More
450 mm dia. piles

-

-

-

... More
IN INR

720

-

-

... More
IN USD

720

-

-

... More
IN JPY

720

-

-

... More
Pile Load Test

-

-

-

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 ton and up to 100 ton Safe capacity.

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity) by Maintained load method on test pile.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Routine test (Test Load 1.5 times the Safe capacity) by Maintained load method on test pile.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Lateral load testing of single pile in accordance with IS Code of practice IS: 2911 (Part IV) for determining safe allowable lateral load on pile: Above 50 ton and up to 100 ton capacity pile.

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity)

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Routine test (Test Load 1.5 times the Safe capacity)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerized equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.

-

-

-

... More
IN INR

188

-

-

... More
IN USD

188

-

-

... More
IN JPY

188

-

-

... More
REINFORCEMENT & STRUCTURAL STEEL WORKS

-

-

-

... More
Supplying and fabricating Thermo Mechanically Treated High Corrosion Resistance (CRS) bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008, including fixing with binding wires, assembling, and laying in position for all RCC works as follows.

-

-

-

... More
8 mm dia. rod (Fe-500 D Grade with CRS material)

-

-

-

... More
IN INR

91079

-

-

... More
IN USD

91079

-

-

... More
IN JPY

91079

-

-

... More
10 mm – 32 mm dia. rod (Fe-500D grade with CRS material)

-

-

-

... More
IN INR

516115

-

-

... More
IN USD

516115

-

-

... More
IN JPY

516115

-

-

... More
Structural steel work in single section/built up section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying two coats of approved primer and two coats of approved epoxy paint all complete.

-

-

-

... More
IN INR

17320

-

-

... More
IN USD

17320

-

-

... More
IN JPY

17320

-

-

... More
FINISHING WORKS

-

-

-

... More
Masonry works

-

-

-

... More
Stock brick work with II class bricks in cement mortar 1:5 (Crushed stone sand (M sand)) for over 23cm thick wall including curing etc. complete.

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

238

-

-

... More
IN USD

238

-

-

... More
IN JPY

238

-

-

... More
4.5 - 9.0 m height

-

-

-

... More
IN INR

117

-

-

... More
IN USD

117

-

-

... More
IN JPY

117

-

-

... More
Extra labour for 11cm thick wall

-

-

-

... More
IN INR

13

-

-

... More
IN USD

13

-

-

... More
IN JPY

13

-

-

... More
Plastering work

-

-

-

... More
Plastering (Internal) with cement mortar 1:3 (Crushed stone sand (M-sand)) for 12mm thick including curing, etc., complete.

-

-

-

... More
IN INR

3661

-

-

... More
IN USD

3661

-

-

... More
IN JPY

3661

-

-

... More
Plastering (External) with cement mortar 1:4 (Crushed stone sand (M-sand)) for 20mm thick including curing, etc., complete.

-

-

-

... More
IN INR

1222

-

-

... More
IN USD

1222

-

-

... More
IN JPY

1222

-

-

... More
Special ceiling plastering for RCC slabs, and beams in CM 1:3 using Crushed stone sand (M-sand) – 10mm thick including hacking and curing, etc., complete.

-

-

-

... More
IN INR

1576

-

-

... More
IN USD

1576

-

-

... More
IN JPY

1576

-

-

... More
Flooring works

-

-

-

... More
Flooring with 100mm thick base cement concrete 1:4:10 using 40mm gauge, hard broken stone jelly including laying, ramming, curing, etc., complete.

-

-

-

... More
IN INR

260

-

-

... More
IN USD

260

-

-

... More
IN JPY

260

-

-

... More
Flooring with Macrona Marble slabs, of size 1200 x 1800 x 20mm free from all defects in all floors over a base layer of CM 1:3, 20mm thick. The marble slab shall be laid over the cement mortar by applying white cement slurry in between base mortar and marble slab. The marble slabs are to be laid that there shall be in line with another joint and uniform by using marble cutting machine without any damage to the sides of corners of the marble slab. The entire area at the marble flooring so laid shall be pointed with white cement neatly including polishing with polishing stone of grade 80 for rough grade, 200 for medium, and grade 360 for nice using necessary oxalic acid etc. so as to glassy and smooth and including hire charges for polishing machine and power consumption charges etc. The Macrona marble slabs, polishing stones, oxalic acid, tin oxide etc., proposed for the work shall be shown to the Engineer and got approved by them before use in the work etc., complete.

-

-

-

... More
IN INR

105.64

-

-

... More
IN USD

105.64

-

-

... More
IN JPY

105.64

-

-

... More
Supplying and fixing in position Cement based hydraulically pressed Anti-Skid tiles (pattern design) 20 mm thick in cement mortar 1:3, 20 mm thick & pointed with same colour of cement etc., complete.

-

-

-

... More
IN INR

17.73

-

-

... More
IN USD

17.73

-

-

... More
IN JPY

17.73

-

-

... More
Granolithic flooring 40 mm thick with cement concrete 1:2:4 mix using 3-10 mm chips and top surface rendered smooth with cement including thread lining and 25 mm dia. G.I. pipe of necessary length for water outlet curing, etc., complete.

-

-

-

... More
IN INR

1372

-

-

... More
IN USD

1372

-

-

... More
IN JPY

1372

-

-

... More
Painting

-

-

-

... More
Painting of white washing of two coats including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

6458

-

-

... More
IN USD

6458

-

-

... More
IN JPY

6458

-

-

... More
Painting two coats with approved cement paint over one coat of primer over cement plastered wall surface, including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

4882

-

-

... More
IN USD

4882

-

-

... More
IN JPY

4882

-

-

... More
JOINERY WORKS

-

-

-

... More
uPVC Doors

-

-

-

... More
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking.

-

-

-

... More
Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door up to 2.00 sqm)

-

-

-

... More
IN INR

5.04

-

-

... More
IN USD

5.04

-

-

... More
IN JPY

5.04

-

-

... More
Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm)

-

-

-

... More
IN INR

21

-

-

... More
IN USD

21

-

-

... More
IN JPY

21

-

-

... More
Fire Door

-

-

-

... More
Providing and fixing fire-resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermiculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge.

-

-

-

... More
IN INR

11.4

-

-

... More
IN USD

11.4

-

-

... More
IN JPY

11.4

-

-

... More
Providing and fixing 50mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermiculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10 x 4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc., consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge.

-

-

-

... More
IN INR

6.3

-

-

... More
IN USD

6.3

-

-

... More
IN JPY

6.3

-

-

... More
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
uPVC Casement (openable) type window

-

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window up to 2.50 sqm).

-

-

-

... More
IN INR

52.2

-

-

... More
IN USD

52.2

-

-

... More
IN JPY

52.2

-

-

... More
uPVC Ventilator

-

-

-

... More
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc., profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between the frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension.

-

-

-

... More
IN INR

49.68

-

-

... More
IN USD

49.68

-

-

... More
IN JPY

49.68

-

-

... More
Rolling Shutter

-

-

-

... More
Supplying and erecting rolling shutters of 76mm 18 gauge of galvanized steel sheet with push and pull or self-coiling type operated by pulling hook with top cover including locking arrangements and fixed in position inside or outside, etc., complete and painting with priming coat of red oxide without lock. (Payment will be made by only for the actual opening of the shutters are rolled up wherever the shutters are to be fixed)

-

-

-

... More
IN INR

115.5

-

-

... More
IN USD

115.5

-

-

... More
IN JPY

115.5

-

-

... More
PLUMBING FOR WATER SUPPLY AND SANITARY WORKS

-

-

-

... More
Supplying CPVC pipes and specials of the following sizes including cutting threading and jointing with necessary specials including carting the materials, fixing to wall with necessary clamps and screws, making holes in roof, repacking the same with necessary brick work and plastering wherever necessary with scaffolding, etc., complete.

-

-

-

... More
20 mm dia.

-

-

-

... More
IN INR

60

-

-

... More
IN USD

60

-

-

... More
IN JPY

60

-

-

... More
Supplying and fixing gate valve of the following sizes

-

-

-

... More
20 mm dia.

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Supplying and fixing C.P. Towel rails 45 cm x 20 mm

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying and fixing C.P. Screw down tap of size 20 mm dia.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Supplying and fixing C.P. flush cock of size 20 mm

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying and fixing chromium plated brass soap dish

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Providing and fixing 75 mm dia. Nahini trap (floor trap) with brass gratings.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Supplying and fixing best mirror of size 60 cm x 45 cm of 6mm thick with plywood back including necessary fittings, etc., complete.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Providing and fixing 15 x 10cm S.W. gully trap with C.I. gratings in B.J. concrete in C.M. 1:4:10 with silt pit diaphragm arrangements etc., complete.

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Providing and fixing 110mm dia. PVC pipe with pipe bend for disposal of wastewater from toilet in pumping station.

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
Supplying and fixing flat back white glazed tipped or tongued urinals of 46.50 x 35.5 x 26.5 cm with 32 mm dia. lead waste pipe with Bell mouth opening of 75cm long 15mm dia. wheel valve with lead and brass connection, etc. complete.

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Providing and fixing colour glazed European water closet with rose wood seating (Black) low level flushing tank with fittings, etc., complete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying and fixing 55cm x 40cm water glazed wash basin with lead and brass connections, C.P. Pillar Tap, and other fittings, etc., complete.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Construction of inspection chambers of following sizes with earth work excavation for foundation, 23 cm thick concrete bed using 40 mm brick jelly concrete in CM 1:4:10 for foundation, brick work in CM 1:6 for chamber, plastering with CM 1:3, 12 mm thick, benching, channelling, supplying, and fixing 45 x 45 cm FRC heavy duty cover and frame, etc., complete.

-

-

-

... More
60 x 60 x 150 cm

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
MISCELLANEOUS WORKS

-

-

-

... More
FRP handrail & Chequered plate

-

-

-

... More
Supplying and fixing of pultruded FRP handrail of 1000 mm height with material confirming to IS 6746-1994 and ASTM standards for mechanical properties. The work shall include all the materials, anchor fasteners and accessories required to fix the handrail and all the materials should be got approved by the Engineer before fixing in position as directed.

-

-

-

... More
IN INR

422

-

-

... More
IN USD

422

-

-

... More
IN JPY

422

-

-

... More
Supplying and fixing of pultruded FRP chequered plate of 8 mm thickness of required size with material confirming to IS 6746-1994 and ASTM standards for mechanical properties. The work shall include all the materials and accessories required to fix the chequered plate and all the materials should be got approved by the Engineer before fixing in position as directed.

-

-

-

... More
IN INR

32

-

-

... More
IN USD

32

-

-

... More
IN JPY

32

-

-

... More
Supplying and fixing of pultruded FRP platform and Staircase tread of height 38 mm of required size with material confirming to IS 6746-1994 and ASTM standards for mechanical properties. The work shall include all the materials and accessories required to install, and all the materials should be got approved by the Engineer before fixing in position as directed.

-

-

-

... More
IN INR

150

-

-

... More
IN USD

150

-

-

... More
IN JPY

150

-

-

... More
Steel ladder

-

-

-

... More
Supply and fixing of stainless-steel ladder consisting of side support and footrest at every 200 mm all member of ladder made up of 18 SWG, 304 Grade stainless steel with stainless steel welded joints. The width of ladder is 500 mm.

-

-

-

... More
IN INR

14

-

-

... More
IN USD

14

-

-

... More
IN JPY

14

-

-

... More
Water Proofing

-

-

-

... More
Providing and applying fiber reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, in all respect etc., complete.

-

-

-

... More
IN INR

1632

-

-

... More
IN USD

1632

-

-

... More
IN JPY

1632

-

-

... More
Concrete with broken brick jelly 20mm gauge in pure slacked lime over R.C.C. roof slab in the proportion of 32:12 ½ (No sand to be used) well beaten with wooden beaters to the required depth of 80mm thick and giving required slope and thickness to roof as required, etc., complete.

-

-

-

... More
IN INR

115.14

-

-

... More
IN USD

115.14

-

-

... More
IN JPY

115.14

-

-

... More
Terrace flooring with two course of flat tiles of 15cmx15cmx12mm using CM 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar.

-

-

-

... More
IN INR

1439.3

-

-

... More
IN USD

1439.3

-

-

... More
IN JPY

1439.3

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels/subway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI212-3R-10 i.e., by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification etc., complete. The product performance shall carry guarantee for 10 years against any leakage.

-

-

-

... More
For vertical surface two coats @ 0.70 kg per sqm

-

-

-

... More
IN INR

1112

-

-

... More
IN USD

1112

-

-

... More
IN JPY

1112

-

-

... More
For horizontal surface one coat @ 1.10 kg per sqm.

-

-

-

... More
IN INR

3496

-

-

... More
IN USD

3496

-

-

... More
IN JPY

3496

-

-

... More
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade.

-

-

-

... More
Two or more coats

-

-

-

... More
IN INR

1651

-

-

... More
IN USD

1651

-

-

... More
IN JPY

1651

-

-

... More
Construction joints of concrete - GI sheets 30 cm wide and 1.6 mm thick.

-

-

-

... More
IN INR

223

-

-

... More
IN USD

223

-

-

... More
IN JPY

223

-

-

... More
Expansion Joint

-

-

-

... More
Providing and fixing in position 12 mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints.

-

-

-

... More
IN INR

94

-

-

... More
IN USD

94

-

-

... More
IN JPY

94

-

-

... More
Providing and fixing in position Stainless steel Grade 304 plate - 1.0 mm thick as per design for expansion joins – 200 mm wide.

-

-

-

... More
IN INR

94

-

-

... More
IN USD

94

-

-

... More
IN JPY

94

-

-

... More
Providing and fixing 160 mm dia. PVC Rainwater downfall pipe from roof to the RWH chamber for collecting the rainwater.

-

-

-

... More
IN INR

96

-

-

... More
IN USD

96

-

-

... More
IN JPY

96

-

-

... More
Providing and fixing of heavy duty FRC cover and frame of size 90 x 90 cm including necessary masonry work and plastering, etc., complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS:10910, on 12 mm dia. steel bar conforming to IS:1786, having minimum cross section as 23mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.

-

-

-

... More
IN INR

25

-

-

... More
IN USD

25

-

-

... More
IN JPY

25

-

-

... More
SCHEDULE2:B.CONSTRUCTION OF PUMPING STATION AT PORUR (350 MLD) – CIVIL WORKS

-

-

-

... More
EARTH WORKS

-

-

-

... More
All kinds of soil

-

-

-

... More
Earth work excavation for foundation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stony earth and earth mixed with small size boulders as per SS 20B with initial lead of 10 m and lift of 2.0 m etc. complete.

-

-

-

... More
0 – 2m

-

-

-

... More
IN INR

4170.7

-

-

... More
IN USD

4170.7

-

-

... More
IN JPY

4170.7

-

-

... More
Extra for every additional one-meter lift or part thereof over initial lift etc. complete.

-

-

-

... More
2 – 3m

-

-

-

... More
IN INR

1081.9

-

-

... More
IN USD

1081.9

-

-

... More
IN JPY

1081.9

-

-

... More
3 – 4m

-

-

-

... More
IN INR

1081.9

-

-

... More
IN USD

1081.9

-

-

... More
IN JPY

1081.9

-

-

... More
4 – 5m

-

-

-

... More
IN INR

1051.9

-

-

... More
IN USD

1051.9

-

-

... More
IN JPY

1051.9

-

-

... More
5 – 6m

-

-

-

... More
IN INR

745.5

-

-

... More
IN USD

745.5

-

-

... More
IN JPY

745.5

-

-

... More
Driving sheet piles for one meter length of gallery each side in sandy soil.

-

-

-

... More
0 – 2m

-

-

-

... More
IN INR

309.3

-

-

... More
IN USD

309.3

-

-

... More
IN JPY

309.3

-

-

... More
2 – 4m

-

-

-

... More
IN INR

309.3

-

-

... More
IN USD

309.3

-

-

... More
IN JPY

309.3

-

-

... More
4 – 6m

-

-

-

... More
IN INR

139.3

-

-

... More
IN USD

139.3

-

-

... More
IN JPY

139.3

-

-

... More
6 – 8m

-

-

-

... More
IN INR

139.3

-

-

... More
IN USD

139.3

-

-

... More
IN JPY

139.3

-

-

... More
Removing sheet piles from one meter length of gallery on each side including stacking the sheet piles properly.

-

-

-

... More
0 – 2 m

-

-

-

... More
IN INR

309.3

-

-

... More
IN USD

309.3

-

-

... More
IN JPY

309.3

-

-

... More
2 – 4 m

-

-

-

... More
IN INR

309.3

-

-

... More
IN USD

309.3

-

-

... More
IN JPY

309.3

-

-

... More
4 – 6 m

-

-

-

... More
IN INR

139.3

-

-

... More
IN USD

139.3

-

-

... More
IN JPY

139.3

-

-

... More
6 – 8 m

-

-

-

... More
IN INR

139.3

-

-

... More
IN USD

139.3

-

-

... More
IN JPY

139.3

-

-

... More
Supplying and filling crushed stone sand (M-sand) for foundations and basement including watering, consolidating, ramming, etc., complete.

-

-

-

... More
IN INR

1561.3

-

-

... More
IN USD

1561.3

-

-

... More
IN JPY

1561.3

-

-

... More
Disposal of surplus earth

-

-

-

... More
IN INR

8131.9

-

-

... More
IN USD

8131.9

-

-

... More
IN JPY

8131.9

-

-

... More
CONCRETE AND ALLIED WORKS

-

-

-

... More
Cement concrete 1:2:4 using crushed stone sand (M-sand) and 12mm to 20mm gauge hard broken stone jelly for plain cement concrete works including laying, ramming, curing, etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
1.5 - 4.5 m depth

-

-

-

... More
IN INR

82.3

-

-

... More
IN USD

82.3

-

-

... More
IN JPY

82.3

-

-

... More
above 4.5 m depth

-

-

-

... More
IN INR

89

-

-

... More
IN USD

89

-

-

... More
IN JPY

89

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

38.8

-

-

... More
IN USD

38.8

-

-

... More
IN JPY

38.8

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade SRC/OPC (43 grade) for reinforced cement concrete structural elements under controlled water cement ratio with plasticizer using 20mm and downgraded machine broken granite stone jelly excluding the cost of Centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 1.5 m depth

-

-

-

... More
IN INR

234.7

-

-

... More
IN USD

234.7

-

-

... More
IN JPY

234.7

-

-

... More
1.5 - 4.5 m depth

-

-

-

... More
IN INR

453.5

-

-

... More
IN USD

453.5

-

-

... More
IN JPY

453.5

-

-

... More
above 4.5 m depth

-

-

-

... More
IN INR

1095.4

-

-

... More
IN USD

1095.4

-

-

... More
IN JPY

1095.4

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

466.2

-

-

... More
IN USD

466.2

-

-

... More
IN JPY

466.2

-

-

... More
4.5 - 9.0 m height

-

-

-

... More
IN INR

807.2

-

-

... More
IN USD

807.2

-

-

... More
IN JPY

807.2

-

-

... More
9.0 - 13.5 m height

-

-

-

... More
IN INR

46.4

-

-

... More
IN USD

46.4

-

-

... More
IN JPY

46.4

-

-

... More
FORM WORK

-

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete slabs or plain surfaces including strutting for raft, wall, column, etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 3 m depth

-

-

-

... More
IN INR

2451.4

-

-

... More
IN USD

2451.4

-

-

... More
IN JPY

2451.4

-

-

... More
3 – 4 m depth

-

-

-

... More
IN INR

226.2

-

-

... More
IN USD

226.2

-

-

... More
IN JPY

226.2

-

-

... More
4 – 5 m depth

-

-

-

... More
IN INR

226.2

-

-

... More
IN USD

226.2

-

-

... More
IN JPY

226.2

-

-

... More
5 – 6 m depth

-

-

-

... More
IN INR

121.1

-

-

... More
IN USD

121.1

-

-

... More
IN JPY

121.1

-

-

... More
6 – 7 m depth

-

-

-

... More
IN INR

185.4

-

-

... More
IN USD

185.4

-

-

... More
IN JPY

185.4

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete for plain surfaces for beams, slabs, columns, stairs & walls, etc., complete.

-

-

-

... More
Above G.L

-

-

-

... More
0 – 3.0 m

-

-

-

... More
IN INR

1276

-

-

... More
IN USD

1276

-

-

... More
IN JPY

1276

-

-

... More
3.0 - 4.0 m

-

-

-

... More
IN INR

846

-

-

... More
IN USD

846

-

-

... More
IN JPY

846

-

-

... More
4.0 - 5.0 m

-

-

-

... More
IN INR

449.3

-

-

... More
IN USD

449.3

-

-

... More
IN JPY

449.3

-

-

... More
5.0 - 6.0 m

-

-

-

... More
IN INR

2208.2

-

-

... More
IN USD

2208.2

-

-

... More
IN JPY

2208.2

-

-

... More
6.0 - 7.0 m

-

-

-

... More
IN INR

1258.3

-

-

... More
IN USD

1258.3

-

-

... More
IN JPY

1258.3

-

-

... More
7.0 - 8.0 m

-

-

-

... More
IN INR

1808.3

-

-

... More
IN USD

1808.3

-

-

... More
IN JPY

1808.3

-

-

... More
8.0 - 9.0 m

-

-

-

... More
IN INR

1432.3

-

-

... More
IN USD

1432.3

-

-

... More
IN JPY

1432.3

-

-

... More
9.0 - 10.0 m

-

-

-

... More
IN INR

324

-

-

... More
IN USD

324

-

-

... More
IN JPY

324

-

-

... More
PILING WORKS

-

-

-

... More
Boring, providing and installation of bored cast-in-situ reinforced cement concrete piles of grade M30 of using SRC/OPC (43 grade) of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical winch machine all complete, including chipping of pile head and disposal, removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).

-

-

-

... More
600 mm dia piles

-

-

-

... More
IN INR

1500

-

-

... More
IN USD

1500

-

-

... More
IN JPY

1500

-

-

... More
450 mm dia piles

-

-

-

... More
IN INR

720

-

-

... More
IN USD

720

-

-

... More
IN JPY

720

-

-

... More
Pile Load Test

-

-

-

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 MT and up to 100 MT Safe capacity.

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity) by Maintained load method on test pile.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Routine test (Test Load 1.5 times the Safe capacity) by Maintained load method on working pile.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Lateral load testing of single pile in accordance with IS Code of practice IS: 2911 (Part IV) for determining safe allowable lateral load on pile. Above 50 MT and up to 100 MT capacity pile.

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity).

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Routine test (Test Load 1.5 times the Safe capacity).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerized equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.

-

-

-

... More
IN INR

111

-

-

... More
IN USD

111

-

-

... More
IN JPY

111

-

-

... More
REINFORCEMENT & STRUCTURAL STEEL WORKS

-

-

-

... More
Supplying and fabricating Thermo Mechanically Treated High Corrosion Resistance (CRS) bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008, including fixing with binding wires, assembling, and laying in position for all RCC works as follows,

-

-

-

... More
8 mm dia. rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

70746.2

-

-

... More
IN USD

70746.2

-

-

... More
IN JPY

70746.2

-

-

... More
10 mm – 32 mm dia. rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

400895.2

-

-

... More
IN USD

400895.2

-

-

... More
IN JPY

400895.2

-

-

... More
Structural steel work in single section / built up section, fixed with or without connecting plate including cutting, hoisting, fixing in position, including applying two coats of approved primer and two coats of approved epoxy paint all complete.

-

-

-

... More
IN INR

34083.5

-

-

... More
IN USD

34083.5

-

-

... More
IN JPY

34083.5

-

-

... More
FINISHING WORKS

-

-

-

... More
Masonry Work

-

-

-

... More
Stock brick work with II class bricks in cement mortar 1:5 (Crushed stone sand (M-sand)) for over 23 cm thick wall including curing etc. complete.

-

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

342.9

-

-

... More
IN USD

342.9

-

-

... More
IN JPY

342.9

-

-

... More
Above 4.5 m height

-

-

-

... More
IN INR

160.8

-

-

... More
IN USD

160.8

-

-

... More
IN JPY

160.8

-

-

... More
Extra labour for 11cm thick wall

-

-

-

... More
IN INR

7

-

-

... More
IN USD

7

-

-

... More
IN JPY

7

-

-

... More
Plastering Work

-

-

-

... More
Special ceiling plastering for RCC slabs, and beams in CM 1:3 using Crushed stone sand (M-sand) – 10mm thick including hacking and curing, etc., complete.

-

-

-

... More
IN INR

2377

-

-

... More
IN USD

2377

-

-

... More
IN JPY

2377

-

-

... More
Plastering (Internal) with cement mortar 1:3 (Crushed stone sand (M-sand)) for 12 mm thick including curing, etc., complete.

-

-

-

... More
IN INR

3372

-

-

... More
IN USD

3372

-

-

... More
IN JPY

3372

-

-

... More
Plastering (External) with cement mortar 1:4 (Crushed stone sand (M-sand)) for 20 mm thick including curing, etc., complete.

-

-

-

... More
IN INR

1320.9

-

-

... More
IN USD

1320.9

-

-

... More
IN JPY

1320.9

-

-

... More
Flooring Work

-

-

-

... More
Granolithic flooring 50 mm thick with cement concrete 1:2:4 using 3-10 mm chips and top surface rendered smooth with cement including thread lining and 25 mm dia. G.I. pipe of necessary length for water outlet curing, etc., complete.

-

-

-

... More
IN INR

2256.6

-

-

... More
IN USD

2256.6

-

-

... More
IN JPY

2256.6

-

-

... More
Supplying and fixing in position Cement based hydraulically pressed Anti-Skid tiles (pattern design) 20 mm thick in cement mortar 1:3, 20 mm thick & pointed with same colour of cement etc., complete.

-

-

-

... More
IN INR

39.7

-

-

... More
IN USD

39.7

-

-

... More
IN JPY

39.7

-

-

... More
Flooring with Macrona Marble slabs, of size 1200 x 1800 x 20 mm free from all defects in all floors over a base layer of CM 1:3, 20 mm thick. The marble slab shall be laid over the cement mortar by applying white cement slurry in between base mortar and marble slab. The marble slabs are to be laid that there shall be in line with another joint and uniform by using marble cutting machine without any damage to the sides of corners of the marble slab. The entire area at the marble flooring so laid shall be pointed with white cement neatly including polishing with polishing stone of grade 80 for rough, grade 200 for medium and grade 360 for nice, using necessary oxalic acid etc. so as to glassy and smooth and including hire charges for polishing machine and power consumption charges etc., The Macrona marble slabs, polishing stones, oxalic acid, tin oxide etc., proposed for the work shall be shown to the Engineer and got approved by them before use in the work etc., complete.

-

-

-

... More
IN INR

72.9

-

-

... More
IN USD

72.9

-

-

... More
IN JPY

72.9

-

-

... More
Painting Work

-

-

-

... More
Painting two coats with approved cement paint over one coat of primer over cement plastered wall surface, including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

4692.9

-

-

... More
IN USD

4692.9

-

-

... More
IN JPY

4692.9

-

-

... More
Painting of white washing of two coats including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

2377

-

-

... More
IN USD

2377

-

-

... More
IN JPY

2377

-

-

... More
JOINERY WORKS

-

-

-

... More
uPVC Doors

-

-

-

... More
Providing and fixing factory made uPVC white colour casement / Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Casement door with 3D hinges made of (big series) frame 67 x 64mm & sash 67 x 110 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door up to 2.00 sqm)

-

-

-

... More
IN INR

6.72

-

-

... More
IN USD

6.72

-

-

... More
IN JPY

6.72

-

-

... More
Casement door with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm)

-

-

-

... More
IN INR

68.25

-

-

... More
IN USD

68.25

-

-

... More
IN JPY

68.25

-

-

... More
Fire Door

-

-

-

... More
Providing and fixing fire-resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermiculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge.

-

-

-

... More
IN INR

22.8

-

-

... More
IN USD

22.8

-

-

... More
IN JPY

22.8

-

-

... More
Providing and fixing 50mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermiculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10 x 4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc., consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge.

-

-

-

... More
IN INR

12.6

-

-

... More
IN USD

12.6

-

-

... More
IN JPY

12.6

-

-

... More
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
uPVC Casement (openable) type window

-

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window up to 2.50 sqm).

-

-

-

... More
IN INR

39.6

-

-

... More
IN USD

39.6

-

-

... More
IN JPY

39.6

-

-

... More
uPVC sliding window

-

-

-

... More
Providing and fixing factory made uPVC white colour sliding glazed window up to 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm up to 2.50 sqm).

-

-

-

... More
IN INR

23.4

-

-

... More
IN USD

23.4

-

-

... More
IN JPY

23.4

-

-

... More
uPVC Ventilator

-

-

-

... More
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension.

-

-

-

... More
IN INR

58.3

-

-

... More
IN USD

58.3

-

-

... More
IN JPY

58.3

-

-

... More
Rolling Shutter

-

-

-

... More
Supplying and erecting rolling shutters of 76 mm 18 gauge of galvanized steel sheet with push and pull or self-coiling type operated by pulling hook with top cover including locking arrangements and fixed in position inside or outside, etc., complete and painting with priming coat of red oxide without lock. (Payment will be made by only for the actual opening of the shutters are rolled up wherever the shutters are to be fixed).

-

-

-

... More
IN INR

213

-

-

... More
IN USD

213

-

-

... More
IN JPY

213

-

-

... More
PLUMBING FOR WATER SUPPLY & SANITARY WORKS

-

-

-

... More
Supplying CPVC pipes and specials of the following sizes including cutting threading and jointing with necessary specials including carting the materials, fixing to wall with necessary clamps and screws, making holes in roof, repacking the same with necessary brick work and plastering wherever necessary with scaffolding, etc., complete.

-

-

-

... More
20 mm dia.

-

-

-

... More
IN INR

100

-

-

... More
IN USD

100

-

-

... More
IN JPY

100

-

-

... More
Supplying and fixing wheel valve of the following sizes

-

-

-

... More
20 mm dia.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Supplying and fixing gate valve of the following sizes

-

-

-

... More
20 mm dia.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Supplying and fixing C.P. Towel rails 45cm x 20 mm

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Supplying and fixing C.P. Screw down tap of size 20 mm dia.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Supplying and fixing C.P. flush cock of size 20 mm

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Supplying and fixing chromium plated brass soap dish

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Providing and fixing 75mm dia. Nahini trap (floor trap) with brass gratings

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Supplying and fixing best mirror of size 60c m x 45 cm of 6 mm thick with plywood back including necessary fittings, etc., complete.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Providing and fixing 15 cm x 10 cm S.W. gully trap with C.I. gratings in B.J. concrete in CM 1:4:10 with silt pit diaphragm arrangements, etc., complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying and fixing flat back white glazed tipped or tongued urinals of 46.50 x 35.5 x 26.5 cm with 32 mm dia. lead wastepipe with Bell mouth opening of 75 cm long 15 mm dia. wheel valve with lead and brass connection, etc. complete.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Providing and fixing colour glazed European water closet with rose wood seating (Black) low level flushing tank with fittings, etc., complete.

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Supplying and fixing 55 cm x 40 cm colour glazed wash basin with lead and brass connections, C.P. Pillar Tap, and other fittings, etc., complete.

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Construction of inspection chambers of following sizes with earth work excavation for foundation, 23 cm thick concrete bed using 40 mm brick jelly concrete in CM 1:4:10 for foundation, brick work in CM 1:6 for chamber, plastering with CM 1:3, 12 mm thick, benching, channelling, supplying, and fixing 45 x 45 cm FRC heavy duty cover and frame, etc., complete.

-

-

-

... More
60 x 60 x 150 cm

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Providing and fixing 110mm dia. PVC pipe with pipe bend for disposal of wastewater from toilet in pumping station.

-

-

-

... More
IN INR

50

-

-

... More
IN USD

50

-

-

... More
IN JPY

50

-

-

... More
MISCELLANEOUS WORKS

-

-

-

... More
FRP Handrail & Chequered plate

-

-

-

... More
Supplying and fixing of pultruded FRP handrail of 1000 mm height with material confirming to IS 6746-1994 and ASTM standards for mechanical properties. The work shall include all the materials, anchor fasteners and accessories required to fix the handrail and all the materials should be got approved by the Engineer before fixing in position as directed.

-

-

-

... More
IN INR

368

-

-

... More
IN USD

368

-

-

... More
IN JPY

368

-

-

... More
Supplying and fixing of pultruded FRP chequered plate of 8 mm thickness of required size with material confirming to IS 6746-1994 and ASTM standards for mechanical properties. The work shall include all the materials and accessories required to fix the chequered plate and all the materials should be got approved by the Engineer before fixing in position as directed.

-

-

-

... More
IN INR

241.5

-

-

... More
IN USD

241.5

-

-

... More
IN JPY

241.5

-

-

... More
Supplying and fixing of pultruded FRP platform grating and Staircase tread of 38 mm height of required size with material confirming to IS 6746-1994 and ASTM standards for mechanical properties. The work shall include all the materials and accessories required to install, and all the materials should be got approved by the Engineer before fixing in position as directed.

-

-

-

... More
IN INR

285

-

-

... More
IN USD

285

-

-

... More
IN JPY

285

-

-

... More
Steel ladder

-

-

-

... More
Supplying and fixing of stain less steel ladder consisting of side support and footrest at every 200 mm all member of ladder made up of 18 SWG, 304 Grade Stainless Steel with stainless steel welded joints. The width of ladder is 500 mm.

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Water proofing

-

-

-

... More
Concrete with broken brick jelly 20 mm gauge in pure slacked lime over RCC roof slab in the proportion of 32:12½ (No sand to be used) well beaten with wooden beaters to the required depth of 80 mm thick and giving required slope and thickness to roof as required, etc., complete.

-

-

-

... More
IN INR

219.2

-

-

... More
IN USD

219.2

-

-

... More
IN JPY

219.2

-

-

... More
Terrace flooring with two courses of flat tiles of 15 cm x 15 cm x 12 mm using CM 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar.

-

-

-

... More
IN INR

2192

-

-

... More
IN USD

2192

-

-

... More
IN JPY

2192

-

-

... More
Providing and applying fiber reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 liter/10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per specification.

-

-

-

... More
IN INR

2192

-

-

... More
IN USD

2192

-

-

... More
IN JPY

2192

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels/subway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry:2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry:1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-10 i.e., by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete etc., as per specification. The product performance shall carry guarantee for 10 years against any leakage.

-

-

-

... More
For vertical surface two coats @ 0.70 kg per sqm.

-

-

-

... More
IN INR

762.5

-

-

... More
IN USD

762.5

-

-

... More
IN JPY

762.5

-

-

... More
For horizontal surface two coats @ 1.10 kg per sqm.

-

-

-

... More
IN INR

665.55

-

-

... More
IN USD

665.55

-

-

... More
IN JPY

665.55

-

-

... More
Construction joints of concrete - GI sheets 30cm wide and 1.6 mm thick.

-

-

-

... More
IN INR

164.7

-

-

... More
IN USD

164.7

-

-

... More
IN JPY

164.7

-

-

... More
Expansion Joint

-

-

-

... More
Providing and fixing in position 12 mm thick bitumen impregnated fiber board conforming to IS:1838, including cost of primer, sealing compound Grade-A in expansion joints.

-

-

-

... More
IN INR

100

-

-

... More
IN USD

100

-

-

... More
IN JPY

100

-

-

... More
Providing and fixing in position Stainless steel Grade 304 plate - 1.0 mm thick as per design for expansion joints.

-

-

-

... More
200mm wide

-

-

-

... More
IN INR

100

-

-

... More
IN USD

100

-

-

... More
IN JPY

100

-

-

... More
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade on concrete surface.

-

-

-

... More
Two or more coats

-

-

-

... More
IN INR

665.6

-

-

... More
IN USD

665.6

-

-

... More
IN JPY

665.6

-

-

... More
Providing and fixing 160mm dia. PVC Rainwater downfall pipe from roof to the RWH chamber for collecting the rainwater.

-

-

-

... More
IN INR

164.9

-

-

... More
IN USD

164.9

-

-

... More
IN JPY

164.9

-

-

... More
Providing and fixing FRC heavy duty cover and frame of size 90 x 90 cm including necessary masonry work and plastering, etc., complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Interconnection of Porur PH 1800 mm dia MS delivery pipe with existing 2000 mm dia MS pipe by providing, supplying and erection of 2000 x 1800 mm Tee including excavation, cutting of existing pipe, jointing, backfilling and construction thrust block, etc. complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
SCHEDULE2C CONSTRUCTION OF CHLORINATION BUILDING AT PORUR – CIVIL WORKS

-

-

-

... More
EARTH WORKS

-

-

-

... More
Earth work excavation for foundation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stony earth and earth mixed with small size boulders as per SS 20B with initial lead of 10m and lift of 2.0m etc. complete.

-

-

-

... More
All kinds of soil

-

-

-

... More
IN INR

222.2

-

-

... More
IN USD

222.2

-

-

... More
IN JPY

222.2

-

-

... More
Excavating, supplying, and filling of local earth (including royalty) by mechanical transport up to a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

-

-

-

... More
IN INR

371.2

-

-

... More
IN USD

371.2

-

-

... More
IN JPY

371.2

-

-

... More
Disposal of surplus earth

-

-

-

... More
IN INR

222.2

-

-

... More
IN USD

222.2

-

-

... More
IN JPY

222.2

-

-

... More
CONCRETE AND ALLIED WORKS

-

-

-

... More
Cement concrete 1:2:4 using crushed stone sand (M-sand) and 12mm to 20mm gauge hard broken stone jelly for plain cement concrete works including laying, ramming, curing, etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 1.5 m depth

-

-

-

... More
IN INR

27.1

-

-

... More
IN USD

27.1

-

-

... More
IN JPY

27.1

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade using SRC/OPC (43 grade) for reinforced cement concrete structural elements under controlled water cement ratio with plasticizer using 20mm and downgraded machine broken granite stone jelly excluding the cost of Centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 1.5 m depth

-

-

-

... More
IN INR

33.5

-

-

... More
IN USD

33.5

-

-

... More
IN JPY

33.5

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

47.5

-

-

... More
IN USD

47.5

-

-

... More
IN JPY

47.5

-

-

... More
4.5 - 9.0 m height

-

-

-

... More
IN INR

26.2

-

-

... More
IN USD

26.2

-

-

... More
IN JPY

26.2

-

-

... More
FORM WORK

-

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete slabs or plain surfaces including strutting for raft, wall, etc.

-

-

-

... More
Below GL

-

-

-

... More
0 - 3 m depth

-

-

-

... More
IN INR

161.9

-

-

... More
IN USD

161.9

-

-

... More
IN JPY

161.9

-

-

... More
Above GL

-

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete for plain surfaces for beams, slabs, columns, stairs & walls etc., complete.

-

-

-

... More
0 - 3.0 m height

-

-

-

... More
IN INR

135.3

-

-

... More
IN USD

135.3

-

-

... More
IN JPY

135.3

-

-

... More
3.0 - 4.0 m height

-

-

-

... More
IN INR

155.3

-

-

... More
IN USD

155.3

-

-

... More
IN JPY

155.3

-

-

... More
4.0 - 5.0 m height

-

-

-

... More
IN INR

173.3

-

-

... More
IN USD

173.3

-

-

... More
IN JPY

173.3

-

-

... More
REINFORCEMENT & STRUCTURAL STEEL WORKS

-

-

-

... More
Supplying and fabricating Thermo Mechanically Treated High Corrosion Resistance (CRS) bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008, including fixing with binding wires, assembling, and laying in position for all RCC works as follows,

-

-

-

... More
8 mm dia. rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

2054

-

-

... More
IN USD

2054

-

-

... More
IN JPY

2054

-

-

... More
10 mm - 32 mm dia. rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

11639.3

-

-

... More
IN USD

11639.3

-

-

... More
IN JPY

11639.3

-

-

... More
Structural steel work in single section / built up section, fixed with or without connecting plate including cutting, hoisting, fixing in position, and applying two coats of approved primer and two coats of approved epoxy paint all complete.

-

-

-

... More
IN INR

2021.5

-

-

... More
IN USD

2021.5

-

-

... More
IN JPY

2021.5

-

-

... More
Supplying & fixing M.S. grills for window and gate including two coats of primer with red lead etc. complete as directed.

-

-

-

... More
IN INR

80

-

-

... More
IN USD

80

-

-

... More
IN JPY

80

-

-

... More
FINISHING WORKS

-

-

-

... More
Masonry Work

-

-

-

... More
Stock brick work with II class bricks in cement mortar 1:5 (Crushed stone sand (M-sand)) for over 23cm thick wall including curing etc. complete.

-

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

58.4

-

-

... More
IN USD

58.4

-

-

... More
IN JPY

58.4

-

-

... More
Above 4.5 m height

-

-

-

... More
IN INR

7.7

-

-

... More
IN USD

7.7

-

-

... More
IN JPY

7.7

-

-

... More
Plastering Work

-

-

-

... More
Plastering (Internal) with cement mortar 1:3 (Crushed stone sand (M-sand)) for 12mm thick including curing, etc., complete.

-

-

-

... More
IN INR

284.9

-

-

... More
IN USD

284.9

-

-

... More
IN JPY

284.9

-

-

... More
Plastering (External) with cement mortar 1:4 (Crushed stone sand (M-sand)) for 20mm thick including curing, etc., complete.

-

-

-

... More
IN INR

284.9

-

-

... More
IN USD

284.9

-

-

... More
IN JPY

284.9

-

-

... More
Flooring Work

-

-

-

... More
Granolithic flooring 25 mm thick with cement concrete 1:2:4 using 3-10 mm chips and top surface rendered smooth with cement including thread lining and 25 mm dia. G.I. pipe of necessary length for water outlet curing, etc. complete.

-

-

-

... More
IN INR

173.2

-

-

... More
IN USD

173.2

-

-

... More
IN JPY

173.2

-

-

... More
Water proofing

-

-

-

... More
Providing and applying fiber reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric water proofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, in all respect etc., complete.

-

-

-

... More
IN INR

131.9

-

-

... More
IN USD

131.9

-

-

... More
IN JPY

131.9

-

-

... More
Concrete with broken brick jelly 20mm gauge in pure slacked lime over R.C.C. roof slab in the proportion of 32:12½ (No sand to be used) well beaten with wooden beaters to the required depth of 80mm thick and giving required slope and thickness to roof as required, etc., complete.

-

-

-

... More
IN INR

13.2

-

-

... More
IN USD

13.2

-

-

... More
IN JPY

13.2

-

-

... More
Terrace flooring with two course of flat tiles of 15 cm x 15 cm x 12 mm using CM 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar.

-

-

-

... More
IN INR

131.9

-

-

... More
IN USD

131.9

-

-

... More
IN JPY

131.9

-

-

... More
Painting Work

-

-

-

... More
Painting two coats with approved cement paint over one coat of primer over cement plastered wall surface, including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

569.8

-

-

... More
IN USD

569.8

-

-

... More
IN JPY

569.8

-

-

... More
Painting of white washing of two coats including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

131.9

-

-

... More
IN USD

131.9

-

-

... More
IN JPY

131.9

-

-

... More
JOINERY WORKS

-

-

-

... More
uPVC Door

-

-

-

... More
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking.

-

-

-

... More
Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm)

-

-

-

... More
IN INR

6.3

-

-

... More
IN USD

6.3

-

-

... More
IN JPY

6.3

-

-

... More
uPVC Casement (openable) type window

-

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68mm & mullion 47 x 68 mm all having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window up to 2.50 sqm).

-

-

-

... More
IN INR

6.6

-

-

... More
IN USD

6.6

-

-

... More
IN JPY

6.6

-

-

... More
uPVC fixed type window / Ventilator

-

-

-

... More
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension.

-

-

-

... More
IN INR

5.52

-

-

... More
IN USD

5.52

-

-

... More
IN JPY

5.52

-

-

... More
Rolling Shutter

-

-

-

... More
Supplying and erecting rolling shutters of 76 mm 18 gauge of galvanized steel sheet with push and pull or self-coiling type operated by pulling hook with top cover including locking arrangements and fixed in position inside or outside, etc., complete and painting with priming coat of red oxide without lock. (Payment will be made by only for the actual opening of the shutters are rolled up wherever the shutters are to be fixed)

-

-

-

... More
IN INR

14.53

-

-

... More
IN USD

14.53

-

-

... More
IN JPY

14.53

-

-

... More
MISCELLANEOUS WORKS

-

-

-

... More
Providing and fixing 160mm dia. PVC Rainwater downfall pipe from roof to the RWH chamber for collecting the rainwater.

-

-

-

... More
IN INR

36.9

-

-

... More
IN USD

36.9

-

-

... More
IN JPY

36.9

-

-

... More
Supplying and providing chain link fence with RCC posts. The RCC posts will be of 2.5 m c.c. and of 2.75 m ht. The posts will be 100 mm square at top and 150 mm square at bottom 2.15 m ht. above ground level and 0.60 m below ground level fixed in c.c. foundation in 1:4:8 of 40 mm size stone jelly used. The foundation is of size 45 x 45 x 90 cm including sand and filling of 15 cm ht. The fencing will be of chain link 75 mm size 10 gauge. The height of fence is 2.0 m after leaving 75 mm gap from ground level including fixing the fence with the posts using G.I. binding wire etc. complete.

-

-

-

... More
IN INR

18.8

-

-

... More
IN USD

18.8

-

-

... More
IN JPY

18.8

-

-

... More
Supplying and fixing barbed wire fencing with the existing R.C.C. posts. The barbed fencing is of 5 rows horizontally and 7 rows vertically. The barbed wire will be of 2 ply 12 gauge including binding the wire with the posts etc. complete as approved.

-

-

-

... More
IN INR

18.8

-

-

... More
IN USD

18.8

-

-

... More
IN JPY

18.8

-

-

... More
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in vertical & horizontal fins, individually or forming box louvers, setting in cement mortar 1:2 (1 cement:2 coarse sand), including the cost of required Centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement:1.5 coarse sand (zone-III):3 graded stone aggregate 20 mm nominal size).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
SCHEDULE:2D.CONSTRUCTION OF SECURITY BUILDING AT PERUR – CIVIL WORKS

-

-

-

... More
EARTH WORKS

-

-

-

... More
Earth work excavation for foundation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stony earth and earth mixed with small size boulders as per SS 20B with initial lead of 10 m and lift of 2.0 m etc. complete.

-

-

-

... More
All kinds of soil

-

-

-

... More
IN INR

52

-

-

... More
IN USD

52

-

-

... More
IN JPY

52

-

-

... More
Excavating, supplying, and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

-

-

-

... More
IN INR

71.3

-

-

... More
IN USD

71.3

-

-

... More
IN JPY

71.3

-

-

... More
Disposal of Surplus Earth

-

-

-

... More
IN INR

52

-

-

... More
IN USD

52

-

-

... More
IN JPY

52

-

-

... More
CONCRETE AND ALLIED WORKS

-

-

-

... More
Cement concrete 1:2:4 using crushed stone sand (M-sand) and 12 to 20mm gauge hard broken stone jelly for plain cement concrete works including laying, ramming, curing, etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 1.5 m depth

-

-

-

... More
IN INR

2.1

-

-

... More
IN USD

2.1

-

-

... More
IN JPY

2.1

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade using SRC/OPC (43 grade) for reinforced cement concrete structural elements under controlled water cement ratio with plasticizer using 20mm and downgraded machine broken granite stone jelly excluding the cost of Centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 1.5 m depth

-

-

-

... More
IN INR

4.5

-

-

... More
IN USD

4.5

-

-

... More
IN JPY

4.5

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

42.1

-

-

... More
IN USD

42.1

-

-

... More
IN JPY

42.1

-

-

... More
FORM WORK

-

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete slabs or plain surfaces including strutting for raft, wall, etc.

-

-

-

... More
Below GL

-

-

-

... More
0 - 3 m depth

-

-

-

... More
IN INR

19.5

-

-

... More
IN USD

19.5

-

-

... More
IN JPY

19.5

-

-

... More
Above GL

-

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete for plain surfaces up to 3.0 m for beams, slabs, columns, stairs & walls etc., complete.

-

-

-

... More
IN INR

66.2

-

-

... More
IN USD

66.2

-

-

... More
IN JPY

66.2

-

-

... More
REINFORCEMENT STEEL WORK

-

-

-

... More
Supplying and fabricating Thermo Mechanically Treated High Corrosion Resistance (CRS) bars manufactured by Primary steel producers / Integrated Steel Plants as per IS:1786-2008, including fixing with binding wires, assembling, and laying in position for all RCC works as follows,

-

-

-

... More
8 mm dia. rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

936.5

-

-

... More
IN USD

936.5

-

-

... More
IN JPY

936.5

-

-

... More
10 mm – 32 mm dia. rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

5306.8

-

-

... More
IN USD

5306.8

-

-

... More
IN JPY

5306.8

-

-

... More
FINISHING WORKS

-

-

-

... More
Masonry Work

-

-

-

... More
Stock brick work with II class bricks in cement mortar 1:5 (Crushed stone sand (M-sand)) for over 23 cm thick wall including curing etc. complete.

-

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

6.9

-

-

... More
IN USD

6.9

-

-

... More
IN JPY

6.9

-

-

... More
Plastering Work

-

-

-

... More
Plastering (Internal) with cement mortar 1:3 (Crushed stone sand (M-sand)) for 12 mm thick including curing, etc., complete.

-

-

-

... More
IN INR

35.1

-

-

... More
IN USD

35.1

-

-

... More
IN JPY

35.1

-

-

... More
Plastering (External) with cement mortar 1:4 (Crushed stone sand (M-sand)) for 20 mm thick including curing, etc., complete.

-

-

-

... More
IN INR

40.2

-

-

... More
IN USD

40.2

-

-

... More
IN JPY

40.2

-

-

... More
Flooring Work

-

-

-

... More
Granolithic flooring 25 mm thick with cement concrete 1:2:4 using 3-10 mm chips and top surface rendered smooth with cement including thread lining and 25 mm dia. G.I. pipe of necessary length for water outlet curing, etc. complete.

-

-

-

... More
IN INR

9

-

-

... More
IN USD

9

-

-

... More
IN JPY

9

-

-

... More
Water proofing

-

-

-

... More
Providing and applying fiber reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, in all respect etc., complete.

-

-

-

... More
IN INR

16.5

-

-

... More
IN USD

16.5

-

-

... More
IN JPY

16.5

-

-

... More
Concrete with broken brick jelly 20mm gauge in pure slacked lime over RCC roof slab in the proportion of 32:12½ (No sand to be used) well beaten with wooden beaters to the required depth of 80mm thick and giving required slope and thickness to roof as required, etc., complete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Terrace flooring with two course of flat tiles of 15 cm x 15 cm x 12 mm using CM 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar.

-

-

-

... More
IN INR

16.5

-

-

... More
IN USD

16.5

-

-

... More
IN JPY

16.5

-

-

... More
Painting Work

-

-

-

... More
Painting two coats with approved cement paint over one coat of primer over cement plastered wall surface, including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

75.3

-

-

... More
IN USD

75.3

-

-

... More
IN JPY

75.3

-

-

... More
Painting of white washing of two coats including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

16.5

-

-

... More
IN USD

16.5

-

-

... More
IN JPY

16.5

-

-

... More
JOINERY WORKS

-

-

-

... More
uPVC Door

-

-

-

... More
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking.

-

-

-

... More
Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm)

-

-

-

... More
IN INR

2.52

-

-

... More
IN USD

2.52

-

-

... More
IN JPY

2.52

-

-

... More
uPVC Casement (openable) type window

-

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window up to 2.50 sqm).

-

-

-

... More
IN INR

5.76

-

-

... More
IN USD

5.76

-

-

... More
IN JPY

5.76

-

-

... More
MISCELLANEOUS WORKS

-

-

-

... More
Providing and fixing 160mm dia. PVC Rainwater downfall pipe from roof to the RWH chamber for collecting the rainwater.

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
SCHEDULE 2E. CONSTRUCTION OF SECURITY BUILDING AT PORUR – CIVIL WORKS

-

-

-

... More
EARTH WORKS

-

-

-

... More
Earth work excavation for foundation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stony earth and earth mixed with small size boulders as per SS 20B with initial lead of 10 m and lift of 2.0 m etc. Complete.

-

-

-

... More
All kinds of soil

-

-

-

... More
IN INR

52

-

-

... More
IN USD

52

-

-

... More
IN JPY

52

-

-

... More
Excavating, supplying, and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

-

-

-

... More
IN INR

71.3

-

-

... More
IN USD

71.3

-

-

... More
IN JPY

71.3

-

-

... More
Disposal of Surplus Earth

-

-

-

... More
IN INR

52

-

-

... More
IN USD

52

-

-

... More
IN JPY

52

-

-

... More
CONCRETE AND ALLIED WORKS

-

-

-

... More
Cement concrete 1:2:4 using crushed stone sand (M-sand) and 12 to 20 mm gauge hard broken stone jelly for plain cement concrete works including laying, ramming, curing, etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 1.5 m depth

-

-

-

... More
IN INR

2.1

-

-

... More
IN USD

2.1

-

-

... More
IN JPY

2.1

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade SRC/OPC (43 grade) for reinforced cement concrete structural elements under controlled water cement ratio with plasticizer using 20 mm and downgraded machine broken granite stone jelly excluding the cost of Centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 1.5 m depth

-

-

-

... More
IN INR

4.5

-

-

... More
IN USD

4.5

-

-

... More
IN JPY

4.5

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

42.1

-

-

... More
IN USD

42.1

-

-

... More
IN JPY

42.1

-

-

... More
FORM WORK

-

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete slabs or plain surfaces including strutting for raft, wall, etc.

-

-

-

... More
Below GL

-

-

-

... More
0 – 3.0 m depth

-

-

-

... More
IN INR

19.5

-

-

... More
IN USD

19.5

-

-

... More
IN JPY

19.5

-

-

... More
Above GL

-

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete for plain surfaces up to 3.0 m for beams, slabs, columns, stairs & walls etc., complete.

-

-

-

... More
IN INR

66.2

-

-

... More
IN USD

66.2

-

-

... More
IN JPY

66.2

-

-

... More
REINFORCEMENT STEEL WORK

-

-

-

... More
Supplying and fabricating Thermo Mechanically Treated High Corrosion Resistance (CRS) bars manufactured by Primary steel producers / Integrated Steel Plants as per IS:1786-2008, including fixing with binding wires, assembling, and laying in position for all RCC works as follows,

-

-

-

... More
8 mm dia. rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

936.5

-

-

... More
IN USD

936.5

-

-

... More
IN JPY

936.5

-

-

... More
10 mm - 32 mm dia. rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

5306.8

-

-

... More
IN USD

5306.8

-

-

... More
IN JPY

5306.8

-

-

... More
FINISHING WORKS

-

-

-

... More
Masonry Work

-

-

-

... More
Stock brick work with II class bricks in cement mortar 1:5 (Crushed stone sand (M-sand)) for over 23 cm thick wall including curing etc. complete.

-

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

6.9

-

-

... More
IN USD

6.9

-

-

... More
IN JPY

6.9

-

-

... More
Plastering Work

-

-

-

... More
Plastering (Internal) with cement mortar 1:3 (Crushed stone sand (M-sand)) for 12 mm thick including curing, etc., complete.

-

-

-

... More
IN INR

35.1

-

-

... More
IN USD

35.1

-

-

... More
IN JPY

35.1

-

-

... More
Plastering (External) with cement mortar 1:4 (Crushed stone sand (M-sand)) for 20 mm thick including curing, etc., complete.

-

-

-

... More
IN INR

40.2

-

-

... More
IN USD

40.2

-

-

... More
IN JPY

40.2

-

-

... More
Flooring Work

-

-

-

... More
Granolithic flooring 25 mm thick with cement concrete 1:2:4 using 3-10 mm chips and top surface rendered smooth with cement including thread lining and 25 mm dia. G.I. pipe of necessary length for water outlet curing, etc. complete.

-

-

-

... More
IN INR

9

-

-

... More
IN USD

9

-

-

... More
IN JPY

9

-

-

... More
Water proofing

-

-

-

... More
Providing and applying fiber reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, in all respect etc., complete.

-

-

-

... More
IN INR

16.5

-

-

... More
IN USD

16.5

-

-

... More
IN JPY

16.5

-

-

... More
Concrete with broken brick jelly 20 mm gauge in pure slacked lime over R.C.C. roof slab in the proportion of 32:12½ (No sand to be used) well beaten with wooden beaters to the required depth of 80 mm thick and giving required slope and thickness to roof as required, etc., complete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Terrace flooring with two course of flat tiles of 15 cm x 15 cm x 12 mm using CM 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar.

-

-

-

... More
IN INR

16.5

-

-

... More
IN USD

16.5

-

-

... More
IN JPY

16.5

-

-

... More
Painting Work

-

-

-

... More
Painting two coats with approved cement paint over one coat of primer over cement plastered wall surface, including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

75.3

-

-

... More
IN USD

75.3

-

-

... More
IN JPY

75.3

-

-

... More
Painting of white washing of two coats including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

16.5

-

-

... More
IN USD

16.5

-

-

... More
IN JPY

16.5

-

-

... More
JOINERY WORKS

-

-

-

... More
uPVC Door

-

-

-

... More
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking.

-

-

-

... More
Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm)

-

-

-

... More
IN INR

2.52

-

-

... More
IN USD

2.52

-

-

... More
IN JPY

2.52

-

-

... More
uPVC Casement (openable) type window

-

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window up to 2.50 sqm).

-

-

-

... More
IN INR

5.76

-

-

... More
IN USD

5.76

-

-

... More
IN JPY

5.76

-

-

... More
MISCELLANEOUS WORKS

-

-

-

... More
Providing and fixing 160mm dia. PVC Rainwater downfall pipe from roof to the RWH chamber for collecting the rainwater.

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
SCHEDULE 3.  CONSTRUCTION OF GROUND LEVEL RESERVOIR (GLR) AT PORUR (15 ML) – CIVIL WORKS

-

-

-

... More
EARTH WORKS

-

-

-

... More
Clearing scrub jungle

-

-

-

... More
IN INR

11500

-

-

... More
IN USD

11500

-

-

... More
IN JPY

11500

-

-

... More
Earth work excavation for foundation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stony earth and earth mixed with small size boulders as per SS 20B with initial lead of 10 m and lift of 2.0 m etc. complete.

-

-

-

... More
0 – 2 m

-

-

-

... More
IN INR

9547

-

-

... More
IN USD

9547

-

-

... More
IN JPY

9547

-

-

... More
Extra for every additional one-meter lift or part thereof over initial lift etc. complete.

-

-

-

... More
2 – 3 m

-

-

-

... More
IN INR

3605.6

-

-

... More
IN USD

3605.6

-

-

... More
IN JPY

3605.6

-

-

... More
3 – 4 m

-

-

-

... More
IN INR

1944.8

-

-

... More
IN USD

1944.8

-

-

... More
IN JPY

1944.8

-

-

... More
4 – 5 m

-

-

-

... More
IN INR

1645.7

-

-

... More
IN USD

1645.7

-

-

... More
IN JPY

1645.7

-

-

... More
5 – 6 m

-

-

-

... More
IN INR

1130.6

-

-

... More
IN USD

1130.6

-

-

... More
IN JPY

1130.6

-

-

... More
6 – 7 m

-

-

-

... More
IN INR

762.8

-

-

... More
IN USD

762.8

-

-

... More
IN JPY

762.8

-

-

... More
Driving sheet piles for one meter length of gallery each side in sandy soil.

-

-

-

... More
0 – 2 m

-

-

-

... More
IN INR

551.4

-

-

... More
IN USD

551.4

-

-

... More
IN JPY

551.4

-

-

... More
2 – 4 m

-

-

-

... More
IN INR

551.4

-

-

... More
IN USD

551.4

-

-

... More
IN JPY

551.4

-

-

... More
4 – 6 m

-

-

-

... More
IN INR

144.1

-

-

... More
IN USD

144.1

-

-

... More
IN JPY

144.1

-

-

... More
6 – 8 m

-

-

-

... More
IN INR

124.1

-

-

... More
IN USD

124.1

-

-

... More
IN JPY

124.1

-

-

... More
Removing sheet piles from one meter length of gallery each side including stacking the sheet piles properly.

-

-

-

... More
0 – 2 m

-

-

-

... More
IN INR

551.4

-

-

... More
IN USD

551.4

-

-

... More
IN JPY

551.4

-

-

... More
2 – 4 m

-

-

-

... More
IN INR

551.4

-

-

... More
IN USD

551.4

-

-

... More
IN JPY

551.4

-

-

... More
4 – 6 m

-

-

-

... More
IN INR

144.1

-

-

... More
IN USD

144.1

-

-

... More
IN JPY

144.1

-

-

... More
6 – 8 m

-

-

-

... More
IN INR

124.1

-

-

... More
IN USD

124.1

-

-

... More
IN JPY

124.1

-

-

... More
Supplying and filling crushed stone sand (M-sand) for foundations and basement including watering, consolidating, ramming, etc., complete.

-

-

-

... More
IN INR

2817

-

-

... More
IN USD

2817

-

-

... More
IN JPY

2817

-

-

... More
Excavating, supplying, and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

-

-

-

... More
IN INR

4066.5

-

-

... More
IN USD

4066.5

-

-

... More
IN JPY

4066.5

-

-

... More
Disposal of surplus earth

-

-

-

... More
IN INR

18636.5

-

-

... More
IN USD

18636.5

-

-

... More
IN JPY

18636.5

-

-

... More
CONCRETE AND ALLIED WORKS

-

-

-

... More
Cement concrete 1:2:4 using crushed stone sand (M-sand) and 12 mm to 20 mm gauge hard broken stone jelly for plain cement concrete works including laying, ramming, curing, etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
1.5 - 4.5 m depth

-

-

-

... More
IN INR

757.3

-

-

... More
IN USD

757.3

-

-

... More
IN JPY

757.3

-

-

... More
above 4.5 m depth

-

-

-

... More
IN INR

65.7

-

-

... More
IN USD

65.7

-

-

... More
IN JPY

65.7

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade using SRC/OPC (43 grade) for reinforced cement concrete structural elements under controlled water cement ratio with plasticizer using 20 mm and downgraded machine broken granite stone jelly excluding the cost of Centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification etc., complete.

-

-

-

... More
Below GL

-

-

-

... More
0 - 1.5 m depth

-

-

-

... More
IN INR

429.2

-

-

... More
IN USD

429.2

-

-

... More
IN JPY

429.2

-

-

... More
1.5 - 4.5 m depth

-

-

-

... More
IN INR

6213.1

-

-

... More
IN USD

6213.1

-

-

... More
IN JPY

6213.1

-

-

... More
above 4.5 m depth

-

-

-

... More
IN INR

645.4

-

-

... More
IN USD

645.4

-

-

... More
IN JPY

645.4

-

-

... More
Above GL

-

-

-

... More
0 - 4.5 m height

-

-

-

... More
IN INR

1559.3

-

-

... More
IN USD

1559.3

-

-

... More
IN JPY

1559.3

-

-

... More
4.5 - 9.0 m height

-

-

-

... More
IN INR

15.7

-

-

... More
IN USD

15.7

-

-

... More
IN JPY

15.7

-

-

... More
FORM WORK

-

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete slabs or plain surfaces including strutting for raft, wall, etc.

-

-

-

... More
Below GL

-

-

-

... More
0 – 3.0 m

-

-

-

... More
IN INR

1238.8

-

-

... More
IN USD

1238.8

-

-

... More
IN JPY

1238.8

-

-

... More
3.0 – 4.0 m

-

-

-

... More
IN INR

433.1

-

-

... More
IN USD

433.1

-

-

... More
IN JPY

433.1

-

-

... More
4.0 – 5.0 m

-

-

-

... More
IN INR

381.5

-

-

... More
IN USD

381.5

-

-

... More
IN JPY

381.5

-

-

... More
5.0 – 6.0 m

-

-

-

... More
IN INR

333.7

-

-

... More
IN USD

333.7

-

-

... More
IN JPY

333.7

-

-

... More
6.0 – 7.0 m

-

-

-

... More
IN INR

394.9

-

-

... More
IN USD

394.9

-

-

... More
IN JPY

394.9

-

-

... More
Above GL

-

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete for plain surfaces for beams, slabs, columns, stairs & walls.

-

-

-

... More
0 – 3.0 m

-

-

-

... More
IN INR

2275.5

-

-

... More
IN USD

2275.5

-

-

... More
IN JPY

2275.5

-

-

... More
3.0 - 4.0 m

-

-

-

... More
IN INR

119.7

-

-

... More
IN USD

119.7

-

-

... More
IN JPY

119.7

-

-

... More
4.0 - 5.0 m

-

-

-

... More
IN INR

3937.3

-

-

... More
IN USD

3937.3

-

-

... More
IN JPY

3937.3

-

-

... More
5.0 - 6.0 m

-

-

-

... More
IN INR

139.4

-

-

... More
IN USD

139.4

-

-

... More
IN JPY

139.4

-

-

... More
PILING WORKS

-

-

-

... More
Boring, providing and installation of bored cast-in-situ reinforced cement concrete piles of grade M30 using SRC/OPC (43 grade) of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical winch machine all complete, including chipping of pile head and disposal, removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).

-

-

-

... More
600 mm dia piles

-

-

-

... More
IN INR

10400

-

-

... More
IN USD

10400

-

-

... More
IN JPY

10400

-

-

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 MT and up to 100 MT Safe capacity.

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity) by Maintained load method on test pile.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Routine test (Test Load 1.5 times the Safe capacity) by Maintained load method on working pile.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Lateral load testing of single pile in accordance with IS Code of practice IS: 2911 (Part IV) for determining safe allowable lateral load on pile. Above 50 MT and up to 100 MT capacity pile.

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity)

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Routine test (Test Load 1.5 times the Safe capacity)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerized equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.

-

-

-

... More
IN INR

304

-

-

... More
IN USD

304

-

-

... More
IN JPY

304

-

-

... More
REINFORCEMENT STEEL WORK

-

-

-

... More
Supplying and fabricating Thermo Mechanically Treated High Corrosion Resistance (CRS) bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008, including fixing with binding wires, assembling, and laying in position for all RCC works as follows,

-

-

-

... More
8 mm dia. rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

232014.8

-

-

... More
IN USD

232014.8

-

-

... More
IN JPY

232014.8

-

-

... More
10 mm - 32 mm dia. rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

1314750.6

-

-

... More
IN USD

1314750.6

-

-

... More
IN JPY

1314750.6

-

-

... More
FINISHING WORKS

-

-

-

... More
Masonry Work

-

-

-

... More
Stock brick work with II class bricks in cement mortar 1:5 (Crushed stone sand (M-sand)) for over 23 cm thick wall including curing etc. complete.

-

-

-

... More
IN INR

15.6

-

-

... More
IN USD

15.6

-

-

... More
IN JPY

15.6

-

-

... More
Plastering Work

-

-

-

... More
Plastering (Internal) with cement mortar 1:3 (Crushed stone sand (M-sand)) for 12 mm thick including curing, etc., complete.

-

-

-

... More
IN INR

67.7

-

-

... More
IN USD

67.7

-

-

... More
IN JPY

67.7

-

-

... More
Plastering (External) with cement mortar 1:4 (Crushed stone sand (M-sand)) for 20 mm thick including curing, etc., complete.

-

-

-

... More
IN INR

47.7

-

-

... More
IN USD

47.7

-

-

... More
IN JPY

47.7

-

-

... More
Flooring Work

-

-

-

... More
Supplying and fixing in position Cement based hydraulically pressed Anti-Skid tiles (pattern design) 20 mm thick in cement mortar 1:3, 20mm thick & pointed with same colour of cement etc., complete.

-

-

-

... More
IN INR

42.8

-

-

... More
IN USD

42.8

-

-

... More
IN JPY

42.8

-

-

... More
Painting Work

-

-

-

... More
Finishing with food grade epoxy paint to be applied in two coats to achieve a minimum total dry film thickness of 200 microns at all locations inside the reservoir, prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.

-

-

-

... More
On Concrete work

-

-

-

... More
IN INR

5798

-

-

... More
IN USD

5798

-

-

... More
IN JPY

5798

-

-

... More
Painting two coats with approved cement paint over one coat of primer over cement plastered wall surface, ceiling including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

874.9

-

-

... More
IN USD

874.9

-

-

... More
IN JPY

874.9

-

-

... More
JOINERY WORKS

-

-

-

... More
Providing and fixing factory made uPVC white colour casement door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking.

-

-

-

... More
IN INR

4.2

-

-

... More
IN USD

4.2

-

-

... More
IN JPY

4.2

-

-

... More
Providing and fixing factory made uPVC white colour fixed ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.

-

-

-

... More
Fixed ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension.

-

-

-

... More
IN INR

8.1

-

-

... More
IN USD

8.1

-

-

... More
IN JPY

8.1

-

-

... More
MISCELLANEOUS WORKS

-

-

-

... More
FRP Handrail

-

-

-

... More
Supplying and fixing of pultruded FRP handrail of 1000 mm height with material confirming to IS 6746-1994 and ASTM standards for mechanical properties. The work shall include all the materials, anchor fasteners and accessories required to fix the handrail and all the materials should be got approved by the Engineer before fixing in position as directed.

-

-

-

... More
IN INR

233

-

-

... More
IN USD

233

-

-

... More
IN JPY

233

-

-

... More
Pre-cast louvers

-

-

-

... More
Providing, hoisting, and fixing above plinth level up to floor five level precast reinforced cement concrete in vertical & horizontal fins, individually or forming box louvers, setting in cement mortar 1:2 (1 cement:2 coarse sand), including the cost of required Centering, shuttering but excluding the cost of reinforcement, with 1:1.5:3 (1 cement:1.5 coarse sand (zone- III): 3 graded stone aggregate 20 mm nominal size).

-

-

-

... More
IN INR

4.8

-

-

... More
IN USD

4.8

-

-

... More
IN JPY

4.8

-

-

... More
Providing, hoisting, and fixing above plinth level up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1 cement:3 coarse sand), cost of required Centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement, with 1:1.5:3 (1 cement:1.5 coarse sand (zone-III):3 graded stone aggregate 20 mm nominal size).

-

-

-

... More
IN INR

2.6

-

-

... More
IN USD

2.6

-

-

... More
IN JPY

2.6

-

-

... More
Providing and fixing FRC heavy duty cover and frame of size 90 x 90 cm including necessary masonry work and plastering, etc., complete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Water Proofing

-

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels/subway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry:2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry:1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-10 i.e., by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification etc. The product performance shall carry guarantee for 10 years against any leakage.

-

-

-

... More
For vertical surface two coats @ 0.70 kg per sqm

-

-

-

... More
IN INR

2582.8

-

-

... More
IN USD

2582.8

-

-

... More
IN JPY

2582.8

-

-

... More
For horizontal surface one coat @ 1.10 kg per sqm.

-

-

-

... More
IN INR

3214.8

-

-

... More
IN USD

3214.8

-

-

... More
IN JPY

3214.8

-

-

... More
Providing and applying fiber reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect etc., complete.

-

-

-

... More
IN INR

3230.5

-

-

... More
IN USD

3230.5

-

-

... More
IN JPY

3230.5

-

-

... More
Concrete with broken brick jelly 20 mm gauge in pure slacked lime over R.C.C. roof slab in the proportion of 32:12½ (No sand to be used) well beaten with wooden beaters to the required depth of 80 mm thick and giving required slope and thickness to roof as required, etc., complete.

-

-

-

... More
IN INR

323.1

-

-

... More
IN USD

323.1

-

-

... More
IN JPY

323.1

-

-

... More
Terrace flooring with two courses of flat tiles of 15 cm x 15 cm x 12 mm using CM 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar etc., complete.

-

-

-

... More
IN INR

3230.5

-

-

... More
IN USD

3230.5

-

-

... More
IN JPY

3230.5

-

-

... More
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture, to give an even shade over concrete surface.

-

-

-

... More
Two or more coats

-

-

-

... More
IN INR

971.3

-

-

... More
IN USD

971.3

-

-

... More
IN JPY

971.3

-

-

... More
Construction joints of concrete - Construction joints of PVC water bar 150 mm wide with single bulb.

-

-

-

... More
IN INR

835.5

-

-

... More
IN USD

835.5

-

-

... More
IN JPY

835.5

-

-

... More
Steel ladder

-

-

-

... More
Supplying and fixing of stain less steel ladder consisting of side support and footrest at every 200mm all member of ladder made up of 18 SWG, 304 Grade Stainless Steel with stainless steel welded joints. The width of ladder is 500 mm.

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Supplying and fixing of 150 mm dia. FRP ventilating pipe of 2 m length each with cowl.

-

-

-

... More
IN INR

220

-

-

... More
IN USD

220

-

-

... More
IN JPY

220

-

-

... More
Providing and fixing 160 mm dia. PVC Rainwater downfall pipe from roof to the RWH chamber for collecting the rainwater.

-

-

-

... More
IN INR

72

-

-

... More
IN USD

72

-

-

... More
IN JPY

72

-

-

... More
Expansion Joint

-

-

-

... More
Providing and fixing in position 12 mm thick bitumen impregnated fiber board conforming to IS:1838, including cost of primer, sealing compound Grade-A in expansion joints.

-

-

-

... More
IN INR

100

-

-

... More
IN USD

100

-

-

... More
IN JPY

100

-

-

... More
Providing and fixing in position Stainless steel Grade 304 plate - 1.0 mm thick as per design for expansion joints.

-

-

-

... More
200 mm wide

-

-

-

... More
IN INR

100

-

-

... More
IN USD

100

-

-

... More
IN JPY

100

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS:10910, on 12 mm dia. steel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size) complete as per design.

-

-

-

... More
IN INR

47

-

-

... More
IN USD

47

-

-

... More
IN JPY

47

-

-

... More
Testing of the GLR for water tightness by retaining water for 7 days as per IS 3370 (Part 1) including cost of water, pumping water into the GLR, and bailing out of water (after testing) with necessary pumping equipments including rectifying the leak if any occurred during the test and other incidental and operational charges etc. complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
SCHEDULE 4:CONSTRUCTION OF MISCELLANEOUS WORKS AT PERUR & PORUR – CIVIL WORKS

-

-

-

... More
A.STORM WATER DRAIN WORKS

-

-

-

... More
Construction of Storm water drain as per drawing at Perur PH location including all excavation, concreting, shuttering, reinforcement steel, backfilling, etc. complete as per approval of engineer.

-

-

-

... More
IN INR

285

-

-

... More
IN USD

285

-

-

... More
IN JPY

285

-

-

... More
Construction of Storm water drain as per drawing at Porur GLR and PH location including all excavation, concreting, shuttering, reinforcement steel, backfilling, etc. complete as per approval of engineer.

-

-

-

... More
IN INR

890

-

-

... More
IN USD

890

-

-

... More
IN JPY

890

-

-

... More
Construction of Rainwater Harvesting structure including borehole at the Perur PH campus.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Construction of Rainwater Harvesting structure including borehole at the Porur PH & GLR campus.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
B. INTERNAL ROAD WORK

-

-

-

... More
Construction of internal road as per drawing and specification at Perur PH location including subgrade preparation with excavation, filling, soling and laying of WMM, all required bituminous layers with tack coat, etc. with supplying and fixing of kerb stone at both side of the road complete as per specification.

-

-

-

... More
IN INR

250

-

-

... More
IN USD

250

-

-

... More
IN JPY

250

-

-

... More
Construction of internal road as per drawing and specification at Porur GLR and PH location including subgrade preparation with excavation, filling, soling and laying of WMM, all required bituminous layers with tack coat, etc. with supplying and fixing of kerb stone at both side of the road complete as per specification.

-

-

-

... More
IN INR

370

-

-

... More
IN USD

370

-

-

... More
IN JPY

370

-

-

... More
Construction of Car park as per drawing and specification at Perur PH location including subgrade preparation with excavation, filling, soling, WMM and laying of concrete paver block, etc. with marking of parking lane complete as per approval of engineer.

-

-

-

... More
IN INR

60

-

-

... More
IN USD

60

-

-

... More
IN JPY

60

-

-

... More
C. BOUNDARY WALL WORKS AT PERUR

-

-

-

... More
Earth work excavation and depositing on bank with initial lead of 10m and lift of 2m in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stony earth and earth mixed stony earth and earth mixed with small sizes boulders and hard gravelly soil as per SS 20 B etc. complete.

-

-

-

... More
IN INR

1037

-

-

... More
IN USD

1037

-

-

... More
IN JPY

1037

-

-

... More
Cement concrete 1:2:4 using crushed stone sand (M-sand) and 12 mm to 20 mm gauge hard broken stone jelly for plain cement concrete works including laying, ramming, curing, etc., complete.

-

-

-

... More
IN INR

59

-

-

... More
IN USD

59

-

-

... More
IN JPY

59

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M30 grade using SRC/OPC (43 grade) for reinforced cement concrete structural elements under controlled water cement ratio with plasticizer using 20mm and downgraded machine broken granite stone jelly excluding the cost of Centering and shuttering and reinforcement but including compacting, curing, fixing clamps etc., as per standard specification etc., complete.

-

-

-

... More
IN INR

230.2

-

-

... More
IN USD

230.2

-

-

... More
IN JPY

230.2

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete for plain surfaces up to 3.0 m for beams, slabs, columns, footings & walls.

-

-

-

... More
IN INR

1287

-

-

... More
IN USD

1287

-

-

... More
IN JPY

1287

-

-

... More
Supplying and fabricating Thermo Mechanically Treated High Corrosion Resistance (CRS) bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008, including fixing with binding wires, assembling and laying in position for all RCC works as follows,

-

-

-

... More
8 mm dia rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

3832.5

-

-

... More
IN USD

3832.5

-

-

... More
IN JPY

3832.5

-

-

... More
10 mm -32 mm dia rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

21717.5

-

-

... More
IN USD

21717.5

-

-

... More
IN JPY

21717.5

-

-

... More
Stock brick work with II class bricks in cement mortar 1:5 (Crushed stone sand (M-sand)) for over 23 cm thick wall including curing etc. complete.

-

-

-

... More
IN INR

125

-

-

... More
IN USD

125

-

-

... More
IN JPY

125

-

-

... More
Plastering with cement mortar 1:4 (Crushed stone sand (M-sand)) for 20 mm thick including curing, etc., complete.

-

-

-

... More
IN INR

1296

-

-

... More
IN USD

1296

-

-

... More
IN JPY

1296

-

-

... More
Providing and fixing in position 12 mm thick bitumen impregnated fiber board conforming to IS:1838, including cost of primer, sealing compound Grade-A in expansion joints.

-

-

-

... More
IN INR

37

-

-

... More
IN USD

37

-

-

... More
IN JPY

37

-

-

... More
Supplying and fixing barbed wire fencing over the proposed compound wall with 'L' angle iron 50 x 50 x 6 mm & 1.45 mm posts bent to shape at 2.5m centers with 6 rows of barbed wire and also in a zig zag manner at 25cm c/c connecting all the rows with barbed wire will be of 2 ply and 12 gauge or other approved size including drilling hole in 'L' iron posts and fixing the posts in cement concrete 1:2:4 of size 15 x 15 x 45 cm etc. complete.

-

-

-

... More
IN INR

270

-

-

... More
IN USD

270

-

-

... More
IN JPY

270

-

-

... More
Coping with Cement Concrete of 50 mm thick on top of the brick wall and finished neatly including curing etc. complete as directed.

-

-

-

... More
IN INR

270

-

-

... More
IN USD

270

-

-

... More
IN JPY

270

-

-

... More
Refilling with excavated soil complying with standard specification for filling in foundations and basement.

-

-

-

... More
IN INR

841

-

-

... More
IN USD

841

-

-

... More
IN JPY

841

-

-

... More
Supplying and erection of MS sliding electric operated gate of 4.5 m length and 2 m height as per design approved by engineer including fixing letter ''METROWATER” with logo and applying two coats of primer with red lead etc. compete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying and fixing of MS wicket gate of size 1.0 m x 2.0 m as per approved design including fixing in position with hold fasts etc. with locking arrangements as approved and two coats of priming with red oxide etc. complete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Painting two coats of approved cement paint over one coat of primer on cement plastered wall surface, including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

1350

-

-

... More
IN USD

1350

-

-

... More
IN JPY

1350

-

-

... More
Painting with superior quality epoxy ready mixed paint of approved colour of two coats on steel gates, as directed by Engineer in charge.

-

-

-

... More
IN INR

44

-

-

... More
IN USD

44

-

-

... More
IN JPY

44

-

-

... More
Supply and fixing of Illuminated display boards at Perur and Porur PH entrance including the required structure, excavation, and foundation, etc., if any required complete all as per approved design.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply and fixing of electrically operated Boom barrier after the entrance gate at Perur and Porur PH entrance including the required structure, excavation, and foundation, etc., if any required complete all as per approved design.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
D. BOUNDARY WALL WORKS AT PORUR

-

-

-

... More
Earth work excavation and depositing on bank with initial lead of 10m and lift of 2 m in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stony earth and earth mixed stony earth and earth mixed with small sizes boulders and hard gravelly soil as per SS 20 B etc. complete.

-

-

-

... More
IN INR

1690

-

-

... More
IN USD

1690

-

-

... More
IN JPY

1690

-

-

... More
Cement concrete 1:2:4 using crushed stone sand (M-sand) and 12 mm to 20 mm gauge hard broken stone jelly for plain cement concrete works including laying, ramming, curing, etc., complete.

-

-

-

... More
IN INR

96

-

-

... More
IN USD

96

-

-

... More
IN JPY

96

-

-

... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade using SRC/OPC (43 grade) for reinforced cement concrete structural elements under controlled water cement ratio with plasticizer using 20mm and downgraded machine broken granite stone jelly excluding the cost of Centering and shuttering and reinforcement but including compacting, curing, fixing clamps etc., as per standard specification etc., complete.

-

-

-

... More
IN INR

245

-

-

... More
IN USD

245

-

-

... More
IN JPY

245

-

-

... More
Providing form work with Centering for soffits of Reinforced Cement Concrete for plain surfaces up to 3.0 m for beams, slabs, columns, footings & walls.

-

-

-

... More
IN INR

1612

-

-

... More
IN USD

1612

-

-

... More
IN JPY

1612

-

-

... More
Supplying and fabricating Thermo Mechanically Treated High Corrosion Resistance (CRS) bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008, including fixing with binding wires, assembling and laying in position for all RCC works as follows,

-

-

-

... More
8 mm dia rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

4636.5

-

-

... More
IN USD

4636.5

-

-

... More
IN JPY

4636.5

-

-

... More
10 mm -32 mm dia rod (Fe-500D Grade with CRS material)

-

-

-

... More
IN INR

26273.5

-

-

... More
IN USD

26273.5

-

-

... More
IN JPY

26273.5

-

-

... More
Stock brick work with II class bricks in cement mortar 1:5 (Crushed stone sand (M-sand)) for over 23 cm thick wall including curing etc. complete.

-

-

-

... More
IN INR

202

-

-

... More
IN USD

202

-

-

... More
IN JPY

202

-

-

... More
Plastering with cement mortar 1:4 (Crushed stone sand (M-sand)) for 20 mm thick including curing, etc., complete.

-

-

-

... More
IN INR

2112

-

-

... More
IN USD

2112

-

-

... More
IN JPY

2112

-

-

... More
Providing and fixing in position 12 mm thick bitumen impregnated fiber board conforming to IS:1838, including cost of primer, sealing compound Grade-A in expansion joints.

-

-

-

... More
IN INR

60

-

-

... More
IN USD

60

-

-

... More
IN JPY

60

-

-

... More
Supplying and fixing barbed wire fencing over the proposed compound wall with 'L' angle iron 50 x 50 x 6 mm & 1.45 mm posts bent to shape at 2.5m centers with 6 rows of barbed wire and also in a zig zag manner at 25cm c/c connecting all the rows with barbed wire will be of 2 ply and 12 gauge or other approved size including drilling hole in 'L' iron posts and fixing the posts in cement concrete 1:2:4 of size 15 x 15 x 45 cm etc. complete.

-

-

-

... More
IN INR

440

-

-

... More
IN USD

440

-

-

... More
IN JPY

440

-

-

... More
Coping with Cement Concrete of 50 mm thick on top of the brick wall and finished neatly including curing etc. complete as directed.

-

-

-

... More
IN INR

440

-

-

... More
IN USD

440

-

-

... More
IN JPY

440

-

-

... More
Refilling with excavated soil complying with standard specification for filling in foundations and basement.

-

-

-

... More
IN INR

1421

-

-

... More
IN USD

1421

-

-

... More
IN JPY

1421

-

-

... More
Supplying and erection of MS sliding electric operated gate of 4.5 m length and 2 m height as per design approved by engineer including fixing letter ''METROWATER” with logo and applying two coats of primer with red lead etc. compete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying and fixing of MS wicket gate of size 1.0 m x 2.0 m as per approved design including fixing in position with hold fasts etc. with locking arrangements as approved and two coats of priming with red oxide etc. complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Painting two coats of approved cement paint over one coat of primer on cement plastered wall surface, including cleaning preparing the surface and curing, etc., complete.

-

-

-

... More
IN INR

2112

-

-

... More
IN USD

2112

-

-

... More
IN JPY

2112

-

-

... More
Painting with superior quality epoxy ready mixed paint of approved colour of two coats on steel gates, as directed by Engineer in charge.

-

-

-

... More
IN INR

22

-

-

... More
IN USD

22

-

-

... More
IN JPY

22

-

-

... More
Supply and fixing of Illuminated display boards at Porur PH entrance including the required structure, excavation, and foundation, etc., if any required complete all as per approved design.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply and fixing of electrically operated Boom barrier after the entrance gate at Porur PH entrance including the required structure, excavation, and foundation, etc., if any required complete all as per approved design.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
E. GREEN BELT AND LANDSCAPPING WORKS AT PORUR AND PERUR

-

-

-

... More
Preparing and making greenbelt and landscaping works inside the GLR & Pump House campus other than structures and road areas at Porur and Perur by planting approved plants and grass turf as per drawing and instruction of Engineer.

-

-

-

... More
IN INR

4800

-

-

... More
IN USD

4800

-

-

... More
IN JPY

4800

-

-

... More
SCHEDULE 5:SUPPLY AND INSTALLATION OF ELECTRICAL, MECHANICAL, INSTRUMENTATION CONTROL AND AUTOMATION WORKS AT PERUR

-

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted HT panel with Copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as digital voltmeters, digital ammeters with selector switches, Multi-Function Meters, phase indicating LED lamps, necessary interlocks as required etc., complete with incidental civil & mechanical works and comprising of following majorly and other items in complete as per drawing & specifications; (Capacity of Panel: 11kV, 1250A with 2 I/C, 1 B/C & 10 O/G +2 Bus PT + 2 Line PT) a) 11kV, 1250A, 40 kA Vacuum Circuit Breaker Indoor type with CT and high-speed tripping relay. (For I/C & B/C, 3 Nos.) b) 11 KV, 630 A, 40 kA HT Indoor Single Panel Vacuum Circuit Breaker with CT complete as per specification (for Main Pumps, Aux. Transformers & spares, 10 Nos.) c) Motor & Feeder Protection Relays (CT Operated) Providing, installing numerical type motor or feeder protection relays for providing protection as per drawing e.g., REM 601 or similar (For I/Cs, B/C & O/Gs feeders, 13 Nos.) d) Multi Functions Meters – Flush type for Panel Board LED type, CT/PT, Voltage, Current, Frequency, Kilowatt, Kilo Volt Ampere, KVAR, KVAH, Run Hours, unbalance (V, A), Phase angles, TH–s – Class 1 With RS 485 Port (12 Nos.) e) Cabinet–Type Class 1 and 2 Combined Model SPD to arrest surges and over voltages in the power line due to lightening switching action etc. they must be installed in parallel to the power circuit. (12 Nos.) f) Annunciator windows/Panel, flush mounting type (2I/C+10O/G+1B/C) Other items in complete as per drawing & specifications.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning with complete Termination & Jointing with Indoor HT Termination Kits of various sizes of Aluminium conductor, XLPE, 11kV armoured cable complete erected on trays or underground to be excavated at a depth of 1 m putting 6” layer of sand and covering the cable with brick, sand and route markers and refilling the earth to make good as directed.

-

-

-

... More
a.From 11kV Outgoing feeders at CP1 to 11kV Main Incomers at CP2

-

-

-

... More
Aluminium conductor, XLPE, 11kV, 3Core x 400 sq.mm armoured cable

-

-

-

... More
IN INR

600

-

-

... More
IN USD

600

-

-

... More
IN JPY

600

-

-

... More
Indoor Termination Kit for 11kV XLPE Screened 3 Core x 400 sq.mm cable

-

-

-

... More
IN INR

14

-

-

... More
IN USD

14

-

-

... More
IN JPY

14

-

-

... More
b.From 11kV Outgoing Feeder to Auxiliary transformers.

-

-

-

... More
Aluminium conductor, XLPE, 11kV, 3Core x 300 sq.mm armoured cable.

-

-

-

... More
IN INR

100

-

-

... More
IN USD

100

-

-

... More
IN JPY

100

-

-

... More
Indoor Termination Kit for 11kV XLPE Screened 3 Core x 300 sq.mm cable.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
(i)From 11 kV VCB Panel to MV VFD Panel

-

-

-

... More
(ii) From 11kV MV VFD Panel to HT Main Pump-motor

-

-

-

... More
Aluminium conductor, XLPE, 11kV, 3Core x 240 sq.mm armoured cable.

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
Indoor Termination Kit for 11kV XLPE Screened 3 Core x 240 sq.mm cable.

-

-

-

... More
IN INR

24

-

-

... More
IN USD

24

-

-

... More
IN JPY

24

-

-

... More
Supply, delivery, Installation, Testing & Commissioning of floor mounted type 11 kV Variable Frequency Drive (MV VFD) panel suitable for the MV motor offered for operation in AC three Phase 50 Hz (+/-5%), 11 kV (+/-10%). The drive shall be Multi Pulse Multi Cell Architecture with dry type integrated Isolation/ Input/ Converter Transformer having minimum 7% impedance with suitable no. of pulses. Drive shall be of modular design to provide easy and fast maintenance. For 2 quadrant operation Drive shall have adequate configuration to meet IEEE 519 & IEC61000 standards. VFD should provide constant p.f. 0.95 Inductive (from 30% to 100% speed) without any additional reactor or capacitor. VFD shall inherently protect motor from high dv/dt stress, overcurrent protection at every load and all other motor protections. The MV VFD Panel shall be with IP42 enclosure with integrated forced air-cooling system. Overall Drive efficiency including transformer and other accessories shall be minimum 95% at 75% to 100% continuous loading. Necessary controls including LCD/ LED display, ammeters, voltmeters, switches, LED indicating lamps, selector switches and Start/ Stop push buttons etc. having inter-operability with PLC-SCADA system and all accessories in complete. MV VFD Panel for 11 kV, 1200 kW, MV motors with all motor protections, CTs and other accessories. All items in complete shall be as per drawing & specifications

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supplying, delivery, Installation, Testing & Commissioning of dust and vermin proof local Push Button station fabricated in FRP sheet enclosure with hinged door erected near the Main pump set for Switching the pump set “ON" and "OFF" with 1 No. "ON", 1 No. "OFF" and 1 No. Emergency "EM" push buttons ("EM" push button shall be Mushroom type lockable in "OFF" position), with LED type panel board indicating lamps with required colour suitable for 220V, AC 50 Hz mounted on an angle or ISMC frame support at a convenient height for operating the push buttons and above the local MFL with provision for earthing including incidental civil/ mechanical works etc., complete.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of 3 phase auxiliary transformer, 11/0.433 kV, 50 Hz., 400 kVA, oil immersed and naturally cooled indoor/ outdoor type, copper wound transformer, Dyn11 delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40°C by thermometer in oil and 45°C by the resistance in winding at full load rating, with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, with standard accessories complete with test certificate with losses below 1150 Watts at 50% load, 3300 Watts at 100% load as per IS:1180 2014 energy efficiency level latest amendment-4 energy efficiency level - 2 (earlier efficiency level-3), with necessary permissions of Electrical Inspector.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Delivery, Installation, testing and commissioning of 62.5 kVA Diesel Generating Set with suitable alternator (brushless) output continuous rating, 3Phase, 415V, 50Hz, 0.8 PF AC totally enclosed, acoustic enclosure, air cooled multi cylinder diesel engine developing suitable BHP at 1500rpm with standard accessories, self-excited, self-regulated screen protected alternator with static excitation system running at 1500rpm as IS-4722 with voltage regulation +/- 5%. DG set to be TNPCB norms and CPCB-II Compliant, Residential silencer with exhaust pipe arrangements (insulated with glass wool inside the building) up to outside of room above roof level, standard control panel consisting of ammeter with CT's and selector switch, voltmeter with selectors switch MCCB, energy meter, earth fault relay, indicating lamps, fuses, and required 1.1kV grade XLPE/ PVC armoured aluminium cable from alternator to alternator control panel, 12/24V battery, battery leads, battery charger etc. Coupling with guard, Fuel tank (8 hours capacity) common rigid MS channel Base frame, antivibration mounting pad etc. complete. AMF Panel: Microprocessor based AMF panel suitable for 62.5 kVA capacity of 3 phase 415V, 50Hz AC with all standard features, safeties etc. as per specification.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing and Commissioning of 415V (Low Voltage) Switchgear with necessary accessories with complete.

-

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V LV PMCC panel (800A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as CTs, voltmeters, ammeters with selector switches, Multi-Function meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following majorly and other items in complete as per drawing & specifications; I/C: 800 A, 4 Pole 50 kA, Microprocessor based, EDO Breaker (2 Nos.) B/C: 800 A, 4 Pole 50 kA, Microprocessor based, EDO Breaker (1 No.) O/G: 400A MCCB (TPN) (2 Nos.) O/G: 125A MCCB (TPN) (10 Nos.) O/G: 63A MCCB (TPN) (10 nos.) O/G: DOL starter unit Up to 5 HP confirming to IS 13947 and IEC609471 with a 32A MPCB in each and all other accessories in complete (6 Nos.) Multi Functions Meters (MFM) - Flush type, LED type display for required parameters- Class 1 With RS 485 Port (2 Nos. for I/Cs)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor/ wall mounted 415V Motorized Operated Valves DB (125A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as CTs, voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following majorly and other items in complete as per drawing & specifications; I/C-125A MCCB (TPN) O/G:16A MPCB with ON/OFF/TRIP Indication Lamps with all other accessories in complete (20 Nos.) Multi Functions Meters - Flush type for Panel Board LED type, With RS 485 Port (1 No.)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V Ventilation DB-1 (63A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following and as per drawing and specifications; I/C-63A MCCB (TPN) O/G:16A MPCB with ON/OFF/TRIP Indication Lamps with all other accessories in complete (26 Nos.) Multi Functions Meter - Flush type with all required parameters & features (1 No.)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V Ventilation DB- 2 & 3 (63A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following and as per drawing and specifications; I/C-63A MCCB (TPN) O/G:16A MPCB with ON/OFF/TRIP Indication Lamps with all other accessories in complete (22 Nos. for each) Multi Functions Meter - Flush type with all required parameters & features (1 No. for each)

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V Main Lighting DB (125A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following and as per drawing and specifications; I/C-125A MCCB (TPN) + RCCB (30 mA) (2 Nos.) O/G: 32A MCCB (TPN) (8 Nos) Multi Functions Meter - Flush type with all required parameters & features (2 Nos.)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V ACDB-1 & 2 (160A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required etc., complete with incidental civil & mechanical works and comprising of following and other items as per drawing and specifications; I/C-160A MCCB (TPN) (1 No.) O/G: 63A MCCB (TPN) (6 Nos) O/G: 32A MCCB (TPN) (7 Nos) Multi Functions Meter - Flush type with all required parameters & features (1 No.)

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Delivery, Installation, testing and commissioning of 415V Auto Power Factor Correction (APFC) Panel consists of power capacitor banks for power factor improvement, APFC relay suitable to operate on 415V, 3Ph,50Hz A/C supply, with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as CTs, voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, etc., complete with incidental civil & mechanical works and comprising of following and as per drawing and specifications; Capacity : 160 kVAR each with 8 to 12 stages (a) I/C-400A MCCB (TPN), 1 No. (b) Mixed Die Electric Capacitor with TNEB Test Certificate with accessories (c) 6 to 14 stage - sensitivity up to 50 milli Amp microprocessor based intelligent power factor correction relay, self analysing auto c/k setting according to targeted power factor setting, the relay shall have overload protection, no volt release etc.including Banking Conform to IS 2834. (d) Multi Functions Meter - Flush type Other items in complete as per drawing & specifications.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Lighting Distribution Board (For all indoor areas) - Industrial Type TPMCB DB with IP 54 Protection 8 Ways 3 Phase DB, Per Phase Isolation (PPI) suitable for Lighting with One (1) No. FP, 32 A MCB + Three No. (3) DP 40 A RCCB (30mA sensitivity) for each phase incoming and for outgoings as follows: (i) 16 A SP MCBs (C-Curve) - 12 Nos. (ii) 16 A TPN MCBs (C-Curve) - 4Nos.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
SITC of 110V DC battery bank including MS/Teakwood battery stand, interconnect wiring, distribution board etc. as required complete in all respect of rating:

-

-

-

... More
110V DC, 120 AH Ni-Cd Battery Bank with Maintenance free battery cell bank & connecting wires, stand in complete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
110V DC, 60A Automatic Thyristor control charger (with float cum boost battery charger) with all accessories like switches, measuring instruments, selector switches, LED Indications, Voltmeter, Ammeter etc. complete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
DC Distribution Board with all accessories like switches, measuring instruments, selector switches, LED Indications, Voltmeter, Ammeter etc. complete. I/C-125A MCCB (TPN), 2 Nos. O/G: 32A MCCB (TPN), 7 Nos. Other items in complete as per drawing & specifications.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning with complete Termination & Jointing of Aluminium conductor, XLPE/ PVC, 1.1kV armoured cable complete installed in approved trench/ on trays/ or underground as directed.

-

-

-

... More
1.1kV, Aluminium conductor, XLPE / PVC insulated & armoured Power cable.

-

-

-

... More
4C x 16 Sq.mm (for Inst. SCADA, EOT Crane, Street Lighting DB, Indoor Lighting DBs, Receptacles)

-

-

-

... More
IN INR

1000

-

-

... More
IN USD

1000

-

-

... More
IN JPY

1000

-

-

... More
3.5C x 35 Sq.mm (for Battery Charger Panel, DCDB, Ventilation DB-1, 2)

-

-

-

... More
IN INR

600

-

-

... More
IN USD

600

-

-

... More
IN JPY

600

-

-

... More
3.5C x 70 Sq.mm (for MOV DBs, Ventilation DBs & MLDB Panel)

-

-

-

... More
IN INR

600

-

-

... More
IN USD

600

-

-

... More
IN JPY

600

-

-

... More
3.5C x 120 Sq.mm (for APFC & ACDB Panels)

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
3.5C x 300 Sq.mm (from Transformer to PCC)

-

-

-

... More
IN INR

600

-

-

... More
IN USD

600

-

-

... More
IN JPY

600

-

-

... More
3C x 16 Sq.mm (Motors from 5.5kW to 15 kW)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
1.1kV Copper Power & Control Cables with Cables, Termination kits, glands, lugs, straight thru joints etc. with all required accessories. All complete works.

-

-

-

... More
3C x 4 sq.mm, Cu. Conductor (for MOVs)

-

-

-

... More
IN INR

1000

-

-

... More
IN USD

1000

-

-

... More
IN JPY

1000

-

-

... More
10C x 2.5 sq mm, Cu. Conductor (Transformer to PMCC, PMCC to APFC panel, Trf. To MV panel etc.) (unarmoured)

-

-

-

... More
IN INR

400

-

-

... More
IN USD

400

-

-

... More
IN JPY

400

-

-

... More
12 core x 2.5 sq.mm, Cu. Conductor (from VCB motor feeder to MV VFD Panel) (unarmoured)

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
4C x 2.5 sq mm, Cu. Conductor (For LPBS- 2 Runs, Street light poles JB)

-

-

-

... More
IN INR

800

-

-

... More
IN USD

800

-

-

... More
IN JPY

800

-

-

... More
3 core x 2.5 sq.mm, Cu. Conductor (For Axial Fans, Street lights)

-

-

-

... More
IN INR

1500

-

-

... More
IN USD

1500

-

-

... More
IN JPY

1500

-

-

... More
3 core x 2.5 sq.mm, Cu. Conductor (DCDB to 11kV Switchgear etc.)

-

-

-

... More
IN INR

200

-

-

... More
IN USD

200

-

-

... More
IN JPY

200

-

-

... More
Supply, Installation, Testing & Commissioning of following sizes of FRP ladder type cable trays with rungs at span of 250 mm including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling/wall with suspenders etc., complete as per the specifications given in employers requirement.

-

-

-

... More
600 mm x 100 mm x 3 mm (for Power Cables)

-

-

-

... More
IN INR

400

-

-

... More
IN USD

400

-

-

... More
IN JPY

400

-

-

... More
450 mm x 100 mm x 3 mm (for Power Cables)

-

-

-

... More
IN INR

400

-

-

... More
IN USD

400

-

-

... More
IN JPY

400

-

-

... More
Supply, Installation, Testing and Commissioning of FRP perforated cable trays with cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc. complete and the tray should be fitted on the wall / Ceiling etc. complete as per the specifications;

-

-

-

... More
450 mm x 75 mm x 3 mm (for Power Cables)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
300 mm x 75 mm x 3 mm (for Power/ Control Cables)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
150 mm x 75 mm x 3 mm (for Control Cables)

-

-

-

... More
IN INR

400

-

-

... More
IN USD

400

-

-

... More
IN JPY

400

-

-

... More
RCC Hume pipe, 1 m long, 200 mm dia with collars for Road crossings for Cable & Earth Strip crossing.

-

-

-

... More
IN INR

30

-

-

... More
IN USD

30

-

-

... More
IN JPY

30

-

-

... More
Supply, Installation, Testing and Commissioning of Lighting System with following major equipment, items as per scope, specification and drawings.

-

-

-

... More
Supply of Lighting Luminaires

-

-

-

... More
SITC of 95W LED High Bay Luminaire with high power LED made of pressure diecast aluminium housing with powder coated, Supply Input voltage 120 – 270 V AC, P.F 0.90, high power LED’s having efficacy 130 lumines/watt, System efficacy 100 lm/W and junction temperature 70°C, with Ingress protection IP66, IK05, Driver surge protection 4KV, In house additional Surge protection ≥ 5KV with wide/ Narrow beam optics, THD 10% at 110 Volts AC, driver efficiency 90%, CCT: 3000 K – 5700 K, minimum CRI 70, The LEDs shall be of SMD type (not COB type). The luminaire supplier shall submit the LM79 and LM80 report of the luminaire from the approved NABL accredited laboratory, etc., complete. (For Pump House Low area).

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
SITC of 150W LED High Bay Luminaire with high power LED made of pressure diecast aluminium housing with powder coated, Supply Input voltage 120 – 270 V AC, P.F 0.90, high power LED’s having efficacy 130 lumines/watt, System efficacy 100 lm/W and junction temperature 70°C, with Ingress protection IP66, IK05, Driver surge protection 4KV, In house additional Surge protection ≥ 5KV with wide/ Narrow beam optics, THD 10% at 110 Volts AC, driver efficiency 90%, CCT: 3000 K – 5700 K, minimum CRI 70, The LEDs shall be of SMD type (not COB type). The luminaire supplier shall submit the LM79 and LM80 report of the luminaire from the approved NABL accredited laboratory, etc., complete. (For Pump House High area).

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
SITC of IP20 surface round LED downlighter compatible with system wattage 12W-18W and luminaire lumens not less than 1200 lumens. The system efficacy shall be 100 lm/W. The housing shall be PC engineered with diffused optics with polycarbonate diffuser for better distribution of light. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of 150 lm/W, Colour Temperature-6500K or Higher with LED binning as per ANSI Bin C78.377A, 120 Deg LED Beam Angle, CRI 80, Life of LED as per L70 30000 burning hours, Ambient temp - 0 to 50 Deg C, Driver efficiency 85%, THD 15%, Power factor 0.95, Inbuilt Surge protection in CM ≥ 2.0KV, LED Driver with Voltage range 150-270V AC and Safety Extra Low Voltage Safe level 60V DC as per IEC standard, Electrical Safety with Class 1 Insulation. Driver shall be potted driver with three terminals of P, L, E and both driver and luminaire shall be BIS compliance.(For Toilets other indoor rooms)

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
SITC of 4’ LED batten with wattage 34W and System Efficacy & System lumens of ≥ 117 lm/W 4000 lm respectively. The type of LED shall be SMD type mounted on MCPCB which is mechanically fixed (no glue pasting) with CCT of 6500 K and CRI 80. The housing material shall be aluminium rugged for industrial use. The life of batten shall be 50000 hours at L70. The LED shall be of SDCM 5. The IP rating of the luminaire shall be IP40. The ambient temperature shall be 0-45 deg C. The luminaire optical element shall be UV protected polycarbonate. The luminaire shall be operable from 140 – 270V AC with PF 0.9 and THD 10%. The driver shall be encapsulated type and placed within the luminaire. The driver shall be with in-built surge protection of 4kV. Drivers shall be flicker free and complies to IEEE P1789 standard; ripple 5%. The efficiency of driver shall be 90%. The luminaire shall be BIS approved and carry “R” number. EMI/EMC Compliance. (For Electrical Room, Control Room, Storeroom, Transformer rooms, DG room, AC room, office room etc.)

-

-

-

... More
IN INR

110

-

-

... More
IN USD

110

-

-

... More
IN JPY

110

-

-

... More
SITC of IP65, IK08 4’ LED luminaire with special application luminaire shall be designed to provide undisrupted lighting for dusty and humid indoor application. The luminaire shall be with all-weather extruded aluminium housing and highly efficient electronics with LED system to offer long useful life even in adverse application and environmental conditions. The luminaire shall be with Co-extruded polycarbonate housing and mounded end caps. The system wattage shall be 36W with system lumens of 4400 lumens and system efficacy of 120 lm/W. LED make: that satisfies IEC 62471 Photobiological/RoHS Standards with and LED Efficacy of 150 lm/W, Colour Temperature-6500 K or Higher with LED binning as per ANSI Bin C78.377A, 120 Deg LED Beam Angle, CRI 80, Life of LED as per L70 50000 burning hours, Ambient temp - 0 to 50 Deg C, Driver efficiency 85%, THD 10%, Power factor 0.95, Inbuilt Surge protection in CM 4KV, Constant Current – Constant Voltage LED Driver with APFC Construction, high voltage cutoff & auto restart @ 320V, phase to phase 440V protection up to 8hrs, LED Driver Voltage range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard, Electrical Safety with Class 1 Insulation. (For Battery Room etc.)

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Pole Mounted Hybrid Solar Street lights (with all accessories)

-

-

-

... More
Supply of all-in-one integrated LED hybrid solar streetlight consists of solar photovoltaic module, battery, battery management system, control electronics, LED driver, microwave sensor, Auto changeover switch, Inter-connecting cables and pole mounting piece integrated into the luminaire as a single unit. Solar streetlight with IP65 ingress protection having a system wattage of 60-70W with 8500 lumens (140 lm/W) with 100Wp high efficiency monocrystalline solar panel, highly efficient MPPT based charge controller and 12.8 V, 42 Ah Lithium Ferro Phosphate (LiFePO4) battery with proper battery management system. LED lumen efficacy shall be at least 170 lm/W and LED driver should have 90% efficiency. Typical correlated colour temperature should be 5700 K with CRI 70. It should have microwave sensor-based movement detection and dim level adjustment to effectively extend the working time. AIO should be onsite configurable via a handheld remote. The luminaire should be housed in IK 08 impact resistance certified aluminium with polycarbonate lens cover. The luminaire shall have a specially designed adjustable pole mounting piece for optimal light distribution.

-

-

-

... More
IN INR

14

-

-

... More
IN USD

14

-

-

... More
IN JPY

14

-

-

... More
SITC of 48W LED Peripheral light Luminaire made of pressure diecast aluminium body with powder coated, having protective toughened glass, Supply Input voltage 120 – 270 V AC, P.F 0.90, high power LED’s having efficacy 120 lumines / watt, System efficacy 95 lm/W and junction temperature 70°C, with Ingress protection IP65, Driver surge protection 4KV, external Surge protection ≥ 5KV with optics distribution Type II medium, THD 10% at 110 Volts AC, driver efficiency 90%, CCT: 3000 K – 5700 K, minimum CRI 70, etc., complete.

-

-

-

... More
IN INR

24

-

-

... More
IN USD

24

-

-

... More
IN JPY

24

-

-

... More
SITC of 32 Amps Receptacle on separate board with 32A TPN MCB etc. of approved make in suitable sheet enclosure, including earthing as per specification, including accessories all complete works.

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
SITC of LED Emergency Light fixture with 1 no. 1 feet (30 cm) single tube 9/11 W with M.F. SLA rechargeable battery with 3 hrs. of back up.

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Fixing Charges of Fittings

-

-

-

... More
Fixing all types & all capacities LED fittings Indoor on the wall / ceiling / rafters / gridders using 23 / 0.76" twin twisted PVC insulated wires.

-

-

-

... More
IN INR

184

-

-

... More
IN USD

184

-

-

... More
IN JPY

184

-

-

... More
Supply & fixing of 50 mm dia. FRP Pipe bracket up to 1.5 meters long for fixing LED street light fittings (peripheral) of all capacities on rail / RCC / Wall, using suitable clamps, bolts, nuts and wiring etc. complete. (Peripheral lights)

-

-

-

... More
IN INR

24

-

-

... More
IN USD

24

-

-

... More
IN JPY

24

-

-

... More
Supply & erection of FRP Tubular Pole 8 m free standing single arm bracket, continuously structured pole with FRP base plate of suitable size as per IS & IEC standards with specifications mentioned in the employer’s requirement. The pole should be Fiberglass Reinforced Plastic/ polymer.

-

-

-

... More
IN INR

14

-

-

... More
IN USD

14

-

-

... More
IN JPY

14

-

-

... More
SITC of Automatic Street Light Control Panel with Optical Micro Sensor, Low voltage / High voltage trip and reset, operating voltage 1–0 - 280V AC, 50 HZ with suitable SMC enclosure of IP 54 protection, MCBs and contactor suitable to control the load of 5 kW of single-phase load with necessary clamping arrangements.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
SITC capacitor type 1200 mm high breeze ceiling fan with regulator (on switchboard) ceiling fan complete with down rod blades, shackle canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply, conforming to IS: 374-1979 and with double ball bearing system.

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Circuit & Point Wiring for Switchboard, lighting, fan circuits & sockets in complete.

-

-

-

... More
Primary Point (Circuit Wiring from Indoor lighting LDBs to Switchboards & Power Sockets Circuit maximum 10 meters in length).

-

-

-

... More
Circuit wiring for lighting panel/ distribution board to modular switch box with 4 sq.mm PVC insulated Cu conductor cable of approved make in surface or concealed rigid PVC conduit of suitable size, including paint etc. as required as per specification, including switch, ceiling rose, PVC flush box etc. all complete works.

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
Point wiring for 3 pin/ 5 pin 20Amps Socket outlet points on separate board 4 sq.mm PVC insulated Cu conductor cable, 20A switch etc. of approved make in suitable size of the PVC conduit including earth continuity conductor in surface or concealed wiring system as per specification, including switch and socket, all complete works.

-

-

-

... More
IN INR

15

-

-

... More
IN USD

15

-

-

... More
IN JPY

15

-

-

... More
Secondary Point (from primary tapping point to Light, fan and plug points)

-

-

-

... More
Wiring with 2.5 sq.mm PVC unsheathed copper single core in suitable PVC conduit pipe for lighting with joint box and switch box with continuous earth connection by 14 SWG TC wire. (1 No.)

-

-

-

... More
Run of 2 of 2.5 sq.mm PVC unsheathed copper SC cable in PVC conduit pipe for mains continuous earth connection by 14 SWG TC wire (3 Nos.)

-

-

-

... More
Short point (not exceeding 3m)

-

-

-

... More
IN INR

150

-

-

... More
IN USD

150

-

-

... More
IN JPY

150

-

-

... More
Medium point above 3m and up to 6m

-

-

-

... More
IN INR

170

-

-

... More
IN USD

170

-

-

... More
IN JPY

170

-

-

... More
Long point above 6m and up to 10m

-

-

-

... More
IN INR

170

-

-

... More
IN USD

170

-

-

... More
IN JPY

170

-

-

... More
Plug, Sockets in Modular Enclosure without MCBs

-

-

-

... More
6/10A Single Phase

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
20A Single Phase

-

-

-

... More
IN INR

15

-

-

... More
IN USD

15

-

-

... More
IN JPY

15

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Earthing systems with necessary masonry works in complete.

-

-

-

... More
Earth electrode for grounding of transformers & DG sets Neutral using copper Plate Earthing connected to 40 mm dia 3 meter long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of suitable size with a cast iron cover. The electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts as per IS:3043.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Earth Electrode for grounding of all Equipment and machines etc. using 40 mm dia 3 meter long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of suitable size and cast-iron cover. The electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. 25 kgs. of carbon-based environment friendly backfill compound and suitable clamp.

-

-

-

... More
IN INR

30

-

-

... More
IN USD

30

-

-

... More
IN JPY

30

-

-

... More
Supplying, Installation, Testing, Commissioning and running of GI and Copper strips earthing conductor for grounding connections, using necessary fixing materials as required, laying between earth pit and equipment.

-

-

-

... More
50 x 6 mm Copper Flat (Transformer & DG Neutral)

-

-

-

... More
IN INR

250

-

-

... More
IN USD

250

-

-

... More
IN JPY

250

-

-

... More
50 x 10 mm GI (PCC, Aux Xmer, DG Set, Switchgears etc.)

-

-

-

... More
IN INR

1000

-

-

... More
IN USD

1000

-

-

... More
IN JPY

1000

-

-

... More
50 x 6 mm GI (MCC Panels, Main Motors etc.)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
25 x 6 mm GI (Cable Trays, LDBs, MLDB etc.)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
25 x 3 mm GI (Valve DBs, Fan DBs, Street Lighting etc.)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
Supplying, Installation, Testing, Commissioning and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas, spacers etc.

-

-

-

... More
8 SWG (Receptacles)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
6 SWG (Small Motors)

-

-

-

... More
IN INR

800

-

-

... More
IN USD

800

-

-

... More
IN JPY

800

-

-

... More
Supply, Installation, Testing & Commissioning (SITC) of External Lightning Protection System with all accessories in complete.

-

-

-

... More
SITC of Vertical Air Terminals: Supply & Installation of air termination rod of 3 m length of material AlMgSi of diameter 16/10 mm crimped on both the ends (Tapered Type). The rod shall be mounted with stone and all fixing accessories, and Stainless-steel Folded clamp to connect metal parts with the 8 mm Aluminium conductor to meet the requirement of IS/I–C - 62305-3. Vertical air terminal is selected as per Angle of Protection method conforming to IS/IEC 62305-3 & NBC-2016. Test Parameter: Mechanical Load Test for individual aluminium alloy rods - 120 to 280 N/mm², Salt Spray Test-No sign of corrosion, Tested as per IEC 62561-1 & 2.

-

-

-

... More
IN INR

8

-

-

... More
IN USD

8

-

-

... More
IN JPY

8

-

-

... More
SITC of Air Termination System: Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination system. Cross sectional area of conductor should be min. 50 mm². Conductor is tested for Lightning Impulse current of 100 kA for 10/350 μs, Electrical, Resistivity, Tensile strength & Corrosion test as per IEC 62561-2. Parapet conductor holder for fixing on the Parapet wall for clamping 8 mm dia Aluminium alloy round conductor. Terrace conductor holder shall be considered in the flat surface. Folded clamps/ Metal roof holder considered for Metal sheets for clamping min. 8 mm dia Aluminium alloy round Conductor. Stainless steel cross connector for connecting minimum 8 mm aluminium conductor at cross/Tee junction. Expansion Piece with connector to compensate the expansion and contraction of Solid Round Al. conductor during temperature variations. Folded clamps consider to bond the metal parts. All the Lightning Protection components are tested as per IEC 62561-1&2.

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
SITC and run of min. 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in Down conductor system. Cross sectional area of conductor should be 50 mm². Conductor is tested for Lightning Impulse current of 100 kA for 10/350 μs, Electrical Resistivity, Tensile strength & Corrosion test as per IEC 62561-2. Parapet conductor holder for fixing on the Side wall for clamping 8 mm dia Aluminium alloy round Conductor in RCC building. Lightning counter is required in the building, and it will record number of lightning Strike in the building with date and time. All the Lightning Protection components are tested as per IEC 62561-1& 2.

-

-

-

... More
IN INR

100

-

-

... More
IN USD

100

-

-

... More
IN JPY

100

-

-

... More
SITC of Stainless-Steel Test Joint/ Link with enclosure to interconnect between min. 8 mm Al. round conductor to 10 mm copper bonded round conductor. used to disconnect the earth termination system to enable measurement of resistance. Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1.

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
SITC of maintenance free Supply of non-corrosive 10 mm dia Copper bonded round conductor used for Earth termination in the soil and concrete and it is tested for short circuit test, Electrical resistivity, Tensile strength. Conductor holder is fixed on the Side wall of the building. All the Lightning Protection components are tested as per IEC 62561-1& 2.

-

-

-

... More
IN INR

60

-

-

... More
IN USD

60

-

-

... More
IN JPY

60

-

-

... More
Supply of UL listed Copper bonded rod of 254 microns coating thickness and 3.048 m length can be used as Earthing. The diameter of the rod shall be 14.2mm. Earth rod clamp of required size should be made up of stainless steel. Earth enhancement compound of 25 kg producing low resistance below 1 Ω m of an earth termination system. Material of the earthing enhancing compound shall be chemically inert to subsoil. It shall not pollute the environment. The compound shall be tested and certified as per IEC 62561-7. Earth Chamber Should have an outer dimension of 290 mm x 290 mm x 153 mm made of GFP material. Flush Mounted, removable and lockable cover of the earth pit should be able to withstand 60 kN. Lightning Protection components are tested as per IEC 62561-1 & 2.

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
Supply, Installation, Testing and commissioning of safety procedures for Electrical Equipments as per scope, specification and drawings for following items.

-

-

-

... More
2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS.

-

-

-

... More
IN INR

40

-

-

... More
IN USD

40

-

-

... More
IN JPY

40

-

-

... More
Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
Hand Gloves 11KV Grade

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
First Aid Box complete with all First Aid Medicines.

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Shock Treatment Chart fixed in glass frame

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Danger Board as required by the Electrical Authorities. (Medium Voltage)

-

-

-

... More
IN INR

30

-

-

... More
IN USD

30

-

-

... More
IN JPY

30

-

-

... More
Danger Board as required by the Electrical Authorities. (High Voltage)

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Teak Wood Ladder- 5 m Height

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Earth Discharge Rod (3 Nos. RYB)

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Earthing Truck for 11 kV VCB Panel (cable Side)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Earthing Truck for 11 kV VCB Panel (Bus Side)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Tools & Plant Machineries

-

-

-

... More
Live Line Tester- Connector Screwdriver 901 Taparia Make or equivalent

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Digital Multimeter CE Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Digital Tong Tester CE Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Electrical Air Blower

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Digital Tachometer

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Hand Crimpling Too ”8"

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
DE Spanner set 6 to 32 Jhalani Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Rings spanner set 6 to 32 Jhalani Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Hacksaw Frame with Blade

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
15” Screw Spanner Taparia Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Lever Type Grease Gun

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
200mm Cutting Plier Taparia Make or equivalent

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
200mm Screwdriver 825 Taparia Make or equivalent

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
300mm Screwdriver 829 Taparia Make or equivalent

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
800 gm Ball Pane Hammer with Handle Taparia Make

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
6” Chain wrench best India make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
8” Chain Wrench Best India Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Connector Screwdriver 901 Taparia Make

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
400mm Screwdriver 930 Taparia Make

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
12” Bearing Puller

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
12” Screw Spanner

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Crowbar 5”

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
1” Cold Chisel

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Pipe Wrench 24” Jhalani Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Pipe Wrench 14” Jhalani Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Flat rough File Scissors Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Flat smooth File Scissors Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Round File Rough Scissors

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Round File Smooth Scissors Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Half Round File Rough Scissors Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Half Round File Smooth Scissors Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Mechanical Equipment (Pump with piping and valves)

-

-

-

... More
Supply, Installation, Testing and Commissioning of Single stage, Double Suction, Horizontal Split Case Centrifugal Pumps confirming to IS: 5120 and IS: 9137 Pumps of 4167 cum/hr. capacity at 77.80 M head including all losses, maximum 1000 RPM (syn) with corocoat coating inside the casing for increase pump life & efficiency, complete with all accessories such as Base frame, flexible Coupling, Mating flanges, AISI SS 316 Bolts, gaskets.

-

-

-

... More
1. Shut off head: Min 120% of the specified head. 2.The pumps including working pumps and standby pumps shall be automatically operated in sequence such that no pump shall run continuously for longer duration. This shall be achieved through a control system.

-

-

-

... More
3. The duty condition of the pump should be to the left of the best efficiency point and closer to best efficiency point.

-

-

-

... More
4. Minimum guaranteed efficiency of horizontal split case pumps shall be 88% without negative tolerance.

-

-

-

... More
5. The pump is required to work at an altitude of Mean Sea Level and at a maximum ambient temperature of 50 degree Centigrade.

-

-

-

... More
6. Four working pumps in parallel combination should be able to deliver minimum of 400 MLD at the rated head.

-

-

-

... More
7. Contractor to carry out sump model study & CFD analysis of pump.

-

-

-

... More
Casing: SG Iron IS 1865 Gr. 500/7/GGG50 or 400/15/GGG40.

-

-

-

... More
Impeller: Stainless Steel: ASTM A 743 CF8M Shaft: Stainless Steel: BS 970 Gr. 431 S29/ASTM A 276 Gr.431.

-

-

-

... More
Casing Rings: Stainless Steel : ASTM A743 CA15 Impeller Ring: Stainless Steel : ASTM A743 CA15 Shaft Sleeve: Stainless Steel : ASTM A743 CA15 (Minimum hardness = 400 BHN) Mechanical Seal: Silicon Carbide v/s Silicon Carbide or Tungsten Carbide v/s Tungsten Carbide Note:1. Corocoat coating inside the casing to be provided for increase pump life & efficiency.

-

-

-

... More
2. There shall be difference of 50 BHN hardness between Casing and Impeller rings.

-

-

-

... More
Fasteners, Anchors bolts, Foundation Bolts etc. both in wet and dry areas: Stainless Steel: 316, - Base Plate: MS with epoxy coated. Bearing Life: One Lakh working hours (L10), Pump shall be Painted with Food Grade Epoxy inside and Outside the Pump casing and it should be 250 Microns, High quality corocoat or equivalent coating to be provided in casing an impeller for long term corrosion protection and efficiency improvements.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Installation, Testing, Commissioning of VFD Compatible, Horizontal Foot Mounted Squirrel Cage Induction motor minimum 1200 Kw, 1000 rpm (syn), Efficiency 95% (minimum), compatible for pumps of item no (18).

-

-

-

... More
Specific requirements for motors: Operating condition:

-

-

-

... More
(i) Induction motor shall be TEFC/ CACA type suitable for continuous operation and operating on 3 Ph, 50 Hz. 11kV supply.

-

-

-

... More
(ii) The motor is required to work at an altitude of 10 m above MSL and at a maximum ambient temperature of 50 degree centigrade.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Installation, lowering, laying & Jointing, testing, commissioning of Spirally/Longitudinal welded MS pipes (Fe-410 grade) conforming to IS 3589-2001, perfect linking, welding of joints and Flange Joints to correct position including cost and conveyance of pipes and materials with all lead and lifts, cost of all labour and giving satisfactory hydraulic test as per IS 3589 - 2001 for test pressure and working pressure both at factory and site etc., complete as per detailed specifications with Internal food grade epoxy coating 406 microns of approved make & External food grade epoxy coating 406 microns/Coal Tar Enamel Coating & Wrapping of 4 mm thick, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. The Rates are including rubber insertion or any equivalent to the required specifications with MS Bolts and nuts for Flange Joints complete (Contractor will make his own arrangement for procuring water for testing).

-

-

-

... More
1829 mm with 16 mm thk for flowmeter bypass arrangement

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
1829 mm with 16 mm thk on Common Delivery header

-

-

-

... More
IN INR

60

-

-

... More
IN USD

60

-

-

... More
IN JPY

60

-

-

... More
1829 mm with 16 mm thk on Inlet of GLR

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
1626 mm with 14 mm thk on Common Suction header

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
MS Blind flange for 1600 mm diameter pipe

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Epoxy Coated MS Puddle Flange for 1800 mm diameter MS pipe

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Epoxy Coated MS Puddle Flange for 1600 mm diameter MS pipe

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Epoxy Coated MS Puddle Flange for 900 mm diameter MS pipe

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
914 mm with 10 mm thk on individual Suction side of each pump

-

-

-

... More
IN INR

90

-

-

... More
IN USD

90

-

-

... More
IN JPY

90

-

-

... More
813 mm with 18 mm thk on individual delivery side of each pump

-

-

-

... More
IN INR

90

-

-

... More
IN USD

90

-

-

... More
IN JPY

90

-

-

... More
323.9 mm with 7 mm thk on (Scour Valve)

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
323 mm with 7 mm thick for installing on Pressure Release Valve and Air Release Valve line at 1800 mm NB common header.

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Supply, Installation, rolling, lowering, laying & Jointing, testing, commissioning of MS specials confirming to IS 1916/ 7322: 1985 with latest amendments.

-

-

-

... More
IN INR

200

-

-

... More
IN USD

200

-

-

... More
IN JPY

200

-

-

... More
Supply, Installation, Testing, Commissioning of Ductile Iron Electrically operated Long Body, Double Flanged, Double eccentric Resilient seated Butterfly valve confirming to BS EN 593/BS 5155/IS 13095 MOC: Body & Disc: DI IS 1865 Gr.500/7/GGG50/40, Shaft: Stainless Steel - ASTM A 276 Gr. 431, Seal Retaining Ring: Stainless Steel - ASTM A 743 CF8M, Body Seat Face: ASTM A 743 CF8M / Nickel welded with mating/companion flanges with suitable bypass SS piping & valve arrangement. inside food grade Epoxy powder coating, minimum 250 microns.

-

-

-

... More
1800 mm PN 16 at Common Delivery Header

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
1600 mm PN 10 at Common Suction Header

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
1800 mm PN 16 for flowmeter bypass arrangement (Manual valve)

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Supply, Installation, Testing, Commissioning of Ductile Iron, Rising spindle, electrically operated, metal seated, Sluice valves as per BS 5163-89/IS 14846-2000/DIN 3202 F4 or its latest amendment. Body, Bonnet & Wedge in Ductile Iron IS 1865 Gr.500/7/GGG50/GGG40, Body & Wedge Rings in Bronze/ SS304, Spindle in SS 431/420, Fasteners in SS316 with mating/companion flanges inside food grade Epoxy powder coating, minimum 250 microns.

-

-

-

... More
900 mm PN 10 on Pump Suction Line

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
800 mm PN 16 on Pump Discharge Line

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Installation, Testing, Commissioning of Ductile Iron, Rising spindle, metal seated, Sluice valves as per BS 5163-89/IS 14846-2000/DIN 3202 F4 or its latest amendment. Body, Bonnet & Wedge in Ductile Iron IS 1865 Gr.500/7/GGG50/GGG40, Body & Wedge Rings in Bronze/ SS304, Spindle in SS 431/420, Fasteners in SS316 with mating/companion flanges inside food grade Epoxy powder coating, minimum 250 microns.

-

-

-

... More
300 mm PN 16 on Common header for Scour valve arrangement

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
200 mm PN 16 on Common header for Pressure relief valve isolation arrangement

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
300 mm PN 16 for Bypass of 1800 mm Butterfly Valve on Common Discharge Header

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
300 mm PN 16 for Bypass of Butterfly Valve on 1600 mm Common Suction Header

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
200 mm PN 16 on Common header for Kinetic Air relief valve isolation arrangement

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
100 mm PN 16 manual sluice valves for Bypass of 900 mm on individual pump suction line

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
80 mm PN 16 manual sluice valves for Bypass of each 800 mm discharge line sluice valve

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, installation, testing & Commissioning of Ductile Iron Double flanged Dual plate check valve conforming to API 594 with latest amendments as detailed below of following diameters and types and conveying to work site, loading, unloading, stacking etc. complete with all lead and lift with inside food grade Epoxy powder coating, minimum 250 microns.

-

-

-

... More
1800 mm PN 16 on Common Delivery Header

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Installation, testing & Commissioning of Ductile Iron D/F Tilting disc Swing Check Valves Slanted seated with maximum swing. Body and Disc of ductile cast iron GGG-40/SG-400/15 or GGG-50/SG-500/7, Shaft of stainless steel - SS: 316, Shaft bearing of zinc free bronze, Body Seat Face & Disc Face with SS304/ Integral nickel-chromium overlay welding and micro finished with mating/companion flanges with inside food grade Epoxy powder coating, minimum 250 microns.

-

-

-

... More
800 mm PN 16 on Individual Pump delivery line

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, installation, testing & Commissioning of SS 304 Expansion Bellows of Flange Ends with necessary mating flanges, bolts & Gaskets for Dismantling purpose with inside food grade Epoxy powder coating, minimum 250 microns.

-

-

-

... More
1800 mm PN 16 at Common Delivery Header

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
1800 mm PN 16 for flowmeter bypass arrangement

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
1600 mm PN 10 at Common Suction Header

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
900 mm PN 10 on individual Suction side of each pump

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
800 mm PN 16 on individual Discharge side of each pump

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, installation, testing & Commissioning of Surge anticipating Relief valves against power failure surges or pressure waves caused by velocity changes, quick opening relief easily adjustable pressure setting with mating/companion flanges with inside food grade Epoxy powder coating, minimum 250 microns.

-

-

-

... More
200 mm PN 16 on Common header for Surge Protection air cushion valve.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, installation, testing & Commissioning of Tamper proof DI single chamber air release valves with pressure range from PN 1.0 to 2.5 with body and cover made of Ductile Iron of Grade GGG 40 or equivalent grade conforming to IS 1865 with Food Grade Epoxy Powder coating (EP-P) inside and for outside of colour blue RAL 5005.

-

-

-

... More
200 mm PN 16 both on Common header for Air release valve arrangement.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, installation, testing & Commissioning of MS fabricated supports & chequered plates for pipeline, Ladder & platforms for valve and pump operation & maintenance and other Equipments.

-

-

-

... More
IN INR

200

-

-

... More
IN USD

200

-

-

... More
IN JPY

200

-

-

... More
Air Conditioning & Ventilation system

-

-

-

... More
Supply, Installation, testing & Commissioning of Heavy-Duty Ventilation Fans with bracket blades and Bird cowl arrangement Group "A" Required dia and sweep with 1440 RPM 415V or 230V, 50Hz, AC supply to provide suitable Air changes per hour for different Areas.

-

-

-

... More
Heavy Duty Ventilation Fan 1.5 kW

-

-

-

... More
IN INR

22

-

-

... More
IN USD

22

-

-

... More
IN JPY

22

-

-

... More
Heavy Duty Ventilation Fan 0.75 kW

-

-

-

... More
IN INR

22

-

-

... More
IN USD

22

-

-

... More
IN JPY

22

-

-

... More
Heavy Duty Ventilation Fan 0.37 kW

-

-

-

... More
IN INR

16

-

-

... More
IN USD

16

-

-

... More
IN JPY

16

-

-

... More
Heavy Duty Ventilation Fan 0.25 kW

-

-

-

... More
IN INR

14

-

-

... More
IN USD

14

-

-

... More
IN JPY

14

-

-

... More
Heavy Duty Ventilation Fan 0.12 kW

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Supply, installation, testing & Commissioning of Split Air Conditioner (1.5 Ton BEE 5- Star Rating Inverter type) (2W+1S)

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Energy Efficient Air Conditioning System for cooling of VFD panels minimum capacity 80 TR (Central AC / Chiller / Package / VRF) with ducting and all accessories.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
EOT CRANE

-

-

-

... More
Supply, installation, testing & Commissioning of 15.0 T capacity Double Girder type fully electrically operated EOT crane suitable for handling pumps, motors, valves, pipes etc. with electrically operated hoist class II duty geared travelling trolley with min long travel 52 meter, span 10 meter, lift 10 meter complete with long travel rail track (40 mm sq. bar) moving or cross girder, all three motions electrically operated by suitable rating motor IP 54, control panel & down pendant control block, brake, safety device, cable from motor to starter panel & other required accessories & tested to 50% overload etc. comp. as per site requirement.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Dewatering System & Sump drainage arrangement

-

-

-

... More
Supply, installation, testing & Commissioning of submersible centrifugal sewage non-clog pumps, vertical spindle type pump, wear resistance with submersible motor for the various duty conditions as stated in the annexure. Pump shall be capable of handling min 100 mm solid size with sewage specific gravity of up to 1.05.

-

-

-

... More
Discharge Up to 20 m3/hour @ 15 m head

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Installation, Testing, Commissioning of Ductile Iron, Rising spindle, metal seated, Sluice valves as per BS 5163-89/IS 14846-2000/DIN 3202 F4 or its latest amendment. Body, Bonnet & Wedge in Ductile Iron IS 1865 Gr.500/7/GGG50/GGG40, Body & Wedge Rings in Bronze/ SS304, Spindle in SS 431/420, Fasteners in SS316 with mating/companion flanges.

-

-

-

... More
100 mm dia for delivery Isolation Valve PN 10 (Individual Delivery Side of pumps and Common header of Pumps)

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Installation, Testing, Commissioning of Ductile Iron, D/F Slanted seat Swing Check Valve. Body of ductile cast iron of Grade GGG-40 or equivalent grade and disc of ductile cast iron GGG-40 or equivalent grade with mating/companion flanges.

-

-

-

... More
100 mm dia for delivery Isolation Valve PN 10 (Individual Delivery Side of pumps)

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying, of 100 mm PN 10 of DI flanged pipe confirming to IS 8329:2000 with latest amendments with Cement Mortar Lining (CML) with Portland Slag Cement as per IS 455:1989 and Metallic Zinc Coating.

-

-

-

... More
IN INR

40

-

-

... More
IN USD

40

-

-

... More
IN JPY

40

-

-

... More
Supply, Installation, Testing, Commissioning and fixing of DI specials with ISI mark confirming to IS 9523 / 2000 suitable for jointing 100mm to 600 mm dia. DI pipe coated with rust prevention coatings of DI K12 Fittings & Dismantling joints (Note: In respect of flanged and spigot, flanged and socketed type specials, the rate applicable for flanged type specials is allowed.)

-

-

-

... More
100mm - 200 mm dia.

-

-

-

... More
IN INR

1000

-

-

... More
IN USD

1000

-

-

... More
IN JPY

1000

-

-

... More
Service water Pump set Arrangement

-

-

-

... More
Supply, Installation, Testing, Commissioning of Centrifugal Monobloc Pump set 350 LPM, 20 Meter Head conforming to IS 9079 operating at 2900 RPM with Bronze impeller pump casing: Cast Iron IS 210 FG Gr.260, Impeller: Bronze IS 318 LTB2, Shaft: SS 410.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Installation, Testing, Commissioning, and fixing in position 50 mm G.M GATE VALVES AS PER IS BS 5154.

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Supply, Installation, Testing, Commissioning, and fixing in position 50 mm nominal bore non-return valve.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying, Laying, jointing, testing, and commissioning of GI pipes conforming to IS 1239:1990 with latest amendments including fixing collars, elbows, tees, gland cocks and other fittings (Including cost of specials). Contractor will make his own arrangements for procuring water for testing.

-

-

-

... More
50 mm dia GI pipe (Medium) as per IS 1239/PART I/2004

-

-

-

... More
IN INR

80

-

-

... More
IN USD

80

-

-

... More
IN JPY

80

-

-

... More
50 mm dia Elbow

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
50 mm dia Tee

-

-

-

... More
IN INR

5

-

-

... More
IN USD

5

-

-

... More
IN JPY

5

-

-

... More
50 mm dia Nipple

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
50 mm dia Socket

-

-

-

... More
IN INR

8

-

-

... More
IN USD

8

-

-

... More
IN JPY

8

-

-

... More
50 mm dia Union

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Firefighting equipment

-

-

-

... More
Supply and installation of 5 KG capacity ISI marked dry chemical powder fire extinguisher with initial charges with wall mounting bracket, ready for use (TS 2678).

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Supply and Installation of one set of buckets (3 nos.) with round bottom made of GI sheets24 SWG 9 liter. capacity painted inside white and outside red with a word 'FIRE' on the face of the bucket along with stand to hang the buckets.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply of first aid chart and shock treatment chart with lamination complete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying of wooden first aid box complete

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply of rechargeable Emergency Lamp (600 mm fluorescent lamp)

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying of SS 316 Bolts, nuts and Washers for all the Flange joints for all above listed locations.

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
Supplying of Champion gaskets (Rubber Insertions) for all the Flange joints for all above listed locations (3 Ply RI Sheet).

-

-

-

... More
IN INR

200

-

-

... More
IN USD

200

-

-

... More
IN JPY

200

-

-

... More
ICA Works (Refer General & Particular ICA specifications for scope of works)

-

-

-

... More
Supplying, Installing, commissioning & testing of Ultrasonic Level Indicating Transmitter (IP 65 Enclosure) with indicators& alarms (0- 10 m) on top of CWR at compartment-1 & 2 and Interfacing with PLC based SCADA control system including all required Mounting accessories.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Additional LED Display for Digital Level Indication for local display signal looped with above ultrasonic level transmitter.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying, Installing, commissioning & testing Conductivity type Level Switch (IP 65 Enclosure) High Level & Low-Level sensing with 2-point contact) on top of CWR at compartment-1 & 2 with necessary instrumentation cabling, glands with suitable stub and flange and bolting arrangement for hook-up, as applicable and necessary and also Interfacing with PLC based SCADA control system.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying, Installing, commissioning & testing of Electromagnetic Flow Indicating Transmitter (full bore type- Measuring Range: 0-25000 m3/h) IP 68 Enclosures and 0.1% accuracy with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, inner lining material suitable for potable water (Minimum PTFE or above) and (electrode as minimum Hastelloy C or above), Outer body material suitable for Marine environment (minimum as SS 316), earthing rings (minimum as SS 316) as applicable and necessary. (Meter Size-1200 mm) at common discharge delivery line and also Interfacing with PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Pump Performance (PPMS) Monitoring (IP 65 Enclosure) with required sensors, accessories, wiring and communication to PLC based SCADA system to measure temperature, vibration etc. for each pump set (covering all pumps), pump performance analysis, management & implementation etc.,

-

-

-

... More
Vibration sensor with Transmitter (IP 65 Enclosure) (for each Motor Casing & Pump Casing (DE/NDE)), 2 no. for each pumping unit.

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
Temperature sensor with RTD/Temperature transmitter (IP 65 Enclosure) for pump, 2 nos. for each pump as required.

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
Temperature sensor with RTD/Temperature transmitter (IP 65 Enclosure) for motor (for each motor provided one for DE, NDE, U, V, W winding temperature).

-

-

-

... More
IN INR

30

-

-

... More
IN USD

30

-

-

... More
IN JPY

30

-

-

... More
Axial Displacement sensor (IP 65 Enclosure) one for each pump.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supplying, Installing, commissioning & testing of Pressure Indicating Transmitter range as 0-25 bar (IP 65 Enclosure) at Pumps common discharge line with necessary instrumentation cabling, wetting parts with minimum Hastelloy C, glands and nipple, fittings, conduit with suitable stub and flange, bolting arrangement for hook-up, as applicable and also Interfacing with PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Pressure Switch (IP 65 Enclosure) (0-25 bar) at each delivery line of Pump with necessary instrumentation cabling, wetting parts with minimum Hastelloy C, glands and nipple, fittings, conduit with suitable stub and snubbers, flange and bolting arrangement for hook-up, as applicable and necessary also Interfacing with PLC based SCADA control system.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Pressure Gauge: Supplying, Installing, commissioning & testing of glycerin filled stainless steel pressure gauge (IP 65 Enclosure) of 150 mm Dia. suitable for the pump sets with nipple, snubber for vibration resistance, wetting parts with minimum Hastelloy C, and necessary length of SS tubing suitable for mounting on the suction side of each pump, including 15 NB isolating valve for maintenance etc., complete with all lead and lifts etc., as applicable and necessary. Bourdon type Pressure gauge (0-16 bar) at each Pumps suction line.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Pressure Gauge: Supplying, Installing, commissioning & testing of glycerin filled stainless steel pressure gauge (IP 65 Enclosure) of 150 mm Dia. suitable for the pump sets with nipple, snubber for vibration resistance, wetting parts with minimum Hastelloy C and necessary length of SS tubing suitable for mounting on the delivery side of each pump, including 15 NB isolating valve for maintenance etc., complete with all lead and lifts etc., as applicable, and necessary. Bourdon type Pressure gauge (0-25 bar).

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Pressure Gauge: Supplying, Installing, commissioning & testing of glycerin filled stainless steel pressure gauge (IP 65 Enclosure) of 150 mm Dia. suitable for the pump sets with nipple, snubber for vibration resistance, wetting parts with minimum Hastelloy C and necessary length of SS tubing suitable for mounting on the Common delivery pipeline of pump station, including 15 NB isolating valve for maintenance etc., complete with all lead and lifts etc., as applicable, and necessary. Bourdon type Pressure gauge (0-25 bar) at Pumps common discharge line.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Online Residual Chlorine Analyzer (IP 65 Enclosure) (Make: Hach / E&H / Emerson / Krohe) proposed at pumps common discharge pipeline, Measuring Range: 0-5 ppm with necessary instrumentation cabling, glands and conduit, calibration reagents, (Including installation, Flow Control module, Isolation valves, drain line (vacuum breaker) etc.,) and integration with plant PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Turbidity Analyzer (IP 65 Enclosure) (Make: Hach / E&H / Emerson / Krohe) proposed at pumps common discharge pipeline, Measuring Range: 0-10 NTU with necessary instrumentation cabling, glands and conduit, calibration reagents, (Including installation accessories of Piping, Flow Control module, Isolation valves, drain line (vacuum breaker) etc.,) and integration with plant PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Online Conductivity Analyzer (IP 65 Enclosure) (Make: Hach / E&H / Emerson / Krohe) proposed at pumps common discharge pipeline, Measuring Range: 0-1000 Micro Siemens with necessary instrumentation cabling, glands and conduit, calibration reagents, (Including installation accessories of Piping, Flow Control module, Isolation valves, drain line (vacuum breaker) etc.) and integration with plant PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Online pH/Temperature Analyzer (IP 65 Enclosure) (Make: Hach / E&H / Emerson / Krohe) proposed at pumps common discharge pipeline, Measuring Range: 0-14 with necessary instrumentation cabling, glands and conduit, calibration reagents, (Including installation accessories of Piping, Flow Control module, Isolation valves, drain line (vacuum breaker) etc.) and integration with plant PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Field instruments IP-65 enclosures for outdoor field instrumentation and Junction boxes with IP-65 enclosures as per site condition requirements and all other Installation miscellaneous, accessories such as Cable Conduits, L-sections, GI Pole Supports, Clamps, Nuts & Bolts etc.,

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Instrumentation, control and Automation earthing system (earthing bar, grounding cable, protection system) & Surge protection Devices for the instruments.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, installation, Testing and commissioning of online UPS system (minimum 5 KVA) with Panel (IP 65 Enclosure) Isolation Transformer confirms to IS 16242 (Part-I): 2014 and IEC 60240-1: 2008 with IGBT technology pure sine wave output, double conversion with auto and manual static bypass switch single phase input / Single phase output with battery cell bank (include panel) for complete ICA equipment inclusive of all communication equipment, pump conditioning monitoring, sensors, field instrumentation and Automation/control system i.e. for PLC Control panel, SCADA control workstation/server, power sockets with minimum 4 hours backup on full load. (Reputed Make Only) including Supply installation Testing and commissioning of Automatic transfer switch (ATS) as redundant for power supply source (Reputed Make Only).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, laying, installation, termination & testing of Instrument & power supply cables, glands, sleeves, TB, lugs, conduits, L-sections, GI Pole Supports, Clamps, Nuts & Bolts etc. with proper ventilation panel (include filters) and all accessories complete. (Also specify Running Meter cost additional during execution).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, installation, Testing and commissioning of Cable tray 150 mm size. (Also specify Running Meter cost additional during execution).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Automation System (Refer General & Particular ICA specifications for scope of works)

-

-

-

... More
Supplying, Installing, commissioning & testing of PLC based Control System with option of local control panel HMI screen: It comprises of a dedicated standalone backplane slots embedded with Redundant power supply, CPU Controller systems (Hot and Redundant) protected in an internal wiring PLC control panel (IP 55 Enclosures) having IO Module, a minimum quantities of IO channels which shall be DI:176, DO:82, AI:100, AO:8 and Control Panel shall have the following accessories as minimum like Potential Free Contacts, communication modules (for third party devices data integration to controller), Redundant power supply unit for SMPS systems, Emergency stop push buttons, Ack/reset Push buttons, Lightening Protection Units (LPUs)/Isolators for each Analog Input, 3 nos. of 24-window Alarm Annunciators, Industrial type Ethernet switch (Redundant) with communication link (Redundant) and the same will be configured with Local Area Network (LAN) system) as redundant loops, RTU/RIO units & interface module, Terminal Blocks, LIU units, Panel air ventilation (Filters) and all other panel accessories as required. (Reputed Makes Only).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Latest model (Hardware/software) Laptop (Programming/diagnostics system) with original license key software’s of Operating System, M.S Office included with application and installed software (Intel core processor-I7, 16 GB RAM DDR5, 1 TB HDD, 14" HD screen, HD camera, Graphics card size based on application (OS/PLC/SCADA) requirements), warranty, bag.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
PLC programming application software, SCADA Graphics, control and other Designing application software with all accessories complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
SCADA Control Workstations: SCADA Operator workstations (OWS) and Engineering Control Server Workstation (EWS).

-

-

-

... More
Supplying, Installing, commissioning & testing of Engineering Control Server Workstation Tower type (EWS) integrated redundant SCADA server system (SCADA is on dual redundant server). EWS Hardware Specifications: Minimum Intel Xeon Core Processor W series (3.6 GHz, or the fastest at the time of supply), compatible below items 16 GB DDR5 RAM, 2 nos. 1TB+ HDD, 10K RPM (SATA/SAS) - OS / Application / SQL DB and Transaction Logs RAID 5 series, NC364T PCI express Quad port gigabit Server Adapter 750 W CS HE power supply kit Graphics Adapter – 2 X DVI-I Redundant Ethernet min. 100 Mbps Network interface card Windows Server 2012 x 64 Standard/Data Centre SQL Express (Included) 32" LED Monitor, SATA DVDRW, Keyboard, Mouse, 2 Nos. of Front Ports USB 2.0 & 2 Nos. of Rear Ports with USB 3.0, Card Reader, Num of PCI-E*16 slots: 1, No. of PCI-E*1 slot: 2 HDMI out, Audio Port: Headphone Output Microphone, other default items as per model. Makes: - (DELL / HP) Note: All the hardware and software shall be provided with product license, latest version and with upgradable options for future expansions.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
OWS (SCADA Operator Workstation) Hardware Specifications : Intel Core i7 (3.5GHz) Processor or advanced processor suitable for workstation,16 GB DDR5, 1TB HD 7200 RPM, 32" LED Monitor, Dedicated Graphics Card 2GB, DVD RW, Key Board, Mouse, 2 Nos. of Front Ports USB 2.0 & 2 Nos. of Rear Ports with USB 3.0, Card Reader, Num of PCI-E*16 slots: 1, No. of PCI-E*1 slot: 2 HDMI out, Audio Port: Headphone Output Microphone, other default items as per model. Makes: - DELL / HP) Note: All the hardware and software shall be provided with latest version and with upgradable options for future expansions.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
OWS & EWS software: Latest Windows OS compatible for control system application software, Latest MS OFFICE, and other applicable pre-installed software as per standard supply. Note: All the software shall be provided with latest version and with upgradable options.

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Supplying, Installing, commissioning & testing of SCADA Server application (Real time/Historian) Software with license for SCADA EWS/Server stations (2 nos.). Supplying, Installing, commissioning & testing of SCADA application (Real time/Historian) Software with license for SCADA Operation workstation (1 no.).

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Computerized Maintenance Management System (CM MS): Hardware and Software specifications.

-

-

-

... More
CMMS Hardware Specifications Tower type: Minimum Intel Xeon Core Processor E series (3.6 GHz, or the fastest at the time of supply), compatible below items. 16 GB DDR5 RAM, 2 nos. 500GB+ HDD, 10K RPM (SATA/SAS) - OS / Application / SQL DB and Transaction Logs RAID 1, NC364T PCI express Quad port gigabit Server Adapter 750 W CS HE power supply kit Graphics Adapter – 2 X DVI-I Redundant Ethernet min. 100 Mbps Network interface card Windows Server 2012 x 64 Standard/Data Centre SQL Express (Included) 24" LED Monitor, SATA DVDRW, Keyboard, Mouse, 2 Nos. of Front Ports USB 2.0 & 2 Nos. of Rear Ports with USB 3.0, Card Reader, Num of PCI-E*16 slots: 1, No. of PCI-E*1 slot: 2 HDMI out, Audio Port: Headphone Output Microphone, other default items as per model. Makes: - (DELL / HP) Note 1: All the hardware and software shall be provided with the latest version and with upgradable options for future expansions. Note 2: The CP2 contractor shall install this system either at Perur or Porur location pumping station control room based on their Master control office.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Latest Operating system compatible for CMMS application system, CMMS application software, Latest MS office & server/SQL software and other pre-installed software as per standard supply. Note: All the software shall be provided with product license, latest version and with upgradable options.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of MIS Application software with related accessories software.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Fiber Optics cable patch card (as required quantity) and Ethernet, Fiber Optics cable with armoured cable (Also specify Running Meter cost additional during execution).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Online & offline Laser Jet All-in One-Color Printer (Reputed Make Only) with all accessories complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of minimum LED screen 55" with HDMI/VGA switch with all accessories complete and interface with the plant SCADA Control system to view the operational GUI.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Communication Interface and Cybersecurity Equipment

-

-

-

... More
Supplying, Installing, commissioning & testing of Industrial Managed Modem/Router/Switch (Redundant device configuration) (Reputed Make).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Firewall Device, web server and others if any (Reputed Make).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Wireless Communication System (GSM / GPRS Wireless Gateway is to be configured with control system) minimum 5G network or advanced version during execution and any additional equipment for interfacing/exchanging data with CMWSSB control center room, CP1 and CP3 package contractor, Remote access etc. with all accessories complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Monitoring Requirements

-

-

-

... More
Supplying, Installing, commissioning & testing of Control desk station in control room as per IEC standard with suitable ergonomic furniture (OWS/EWS/CMMS Concole-4 Nos. and 4 Nos. of Chair). i.e., SCADA control System industrial consoles for housing the complete (Operator/workstation/server) system with all accessories complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Fire Detection and Alarm system at Perur pumping station control room. Fire Alarm Panel including controller, IO and interface modules Detectors/sensor Autonomy UPS backup Power supply module others if any

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Access control system Following item as minimum Card Reader Door locks Door contact switch exit push buttons Access cards Access control device Power supply module Alarm and communication unit and others if any

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of public addressing system based at Perur Pumping station control room with autonomy UPS backup includes loudspeakers (quantity depends on floor level and priority station) and with their respective power supply units. Microphone units, alarm units Telephone system (for internal and external networks)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, installing, commissioning & testing of CCTV IR waterproof camera (IP 65 Enclosures for outdoor) suitable for up to 100 ft. with IR Dome camera, control keyboard, DVR, Hard Disk, cables, UPT trans receivers, autonomy UPS for backup etc. (Close Circuit Television System to be installed at Perur pumping station facility to cover all areas within CP2 package facilities).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, installing, commissioning & testing of CCTV server station loaded with CCTV software latest Windows operating system and application software, 32" LED monitors connected via LAN network to SCADA servers. Minimum 1TB hard drive.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Walkie/Talkie instrument for internal communication required during testing, commissioning and Operation & Maintenance including its accessories charger, power chord etc. Minimum quantity as 4 nos.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Other items

-

-

-

... More
Critical spares as required for Commissioning and pumping station startup

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Tools items Tester Screw drivers set Digital Multimeter Clamp On Meter Spanners sets Hart communicator Milliampere source meter Voltage converter compact air blowers/vacuum cleaner special application software’s Jumpers, etc. And others if items as required during execution or testing

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Other expenses like monthly or periodic billing in terms from Internet service provider related for external communication to be included.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
SCHEDULE 6:SUPPLY AND INSTALLATION OF ELECTRICAL, MECHANICAL, INSTRUMENTATION CONTROL AND AUTOMATION WORKS AT PORUR

-

-

-

... More
11 kV Switchgears

-

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted standard 11 KV RMG panel including Loop in, Loop out Load break switches (LBS) and earth switches interlocking. Panel shall be consisting of required quantities of the following accessories with necessary provision for EB metering, 2 Nos. LBS, 1 No. VCB, interconnections between busbars, switches and trunking box, measuring instruments with selector switches, LED Indicators, Meters, Surge Arrestor, PTs with 0.2 Class, Metering CTs with 0.2 Class and Protection CTs with 5P20 Class and necessary interlocks as required etc., complete with incidental civil & mechanical works and comprising of above mentioned items majorly and other items standard TNEB specifications; (Minimum Capacity of RMG Panel: 11kV, 630A, 26.25 KA with 2 I/C LBS + 1 O/G VCB + PTs + CTs etc.) (The contractor has to procure this item only if TNEB/ TANGEDCO is not providing during power supply connection)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted ICOG Isolation VCB HT panel consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as digital voltmeters, digital ammeters with selector switches, Multi-Function Meter, phase indicating LED lamps, necessary interlocks as required etc., complete with incidental civil & mechanical works and comprising of following majorly and other items in complete as per drawing & specifications; (Capacity of Panel: 11kV, 630A with 1 I/C cum O/G +1 Line PT) a) 11 KV, 26.25 KA, 630 A, HT Indoor Single Panel Vacuum Circuit Breaker complete as per specification (1no.) b) Providing, installing triple pole over current and earth fault relay (REJ 601), 3 O/C and 1 E/F with high set over current setting, -50% to -200% of 5 Amp. Earth fault setting, 10% to 40 % of 5 Amp (Numerical Relays) (1no.) c) Providing, installing in panel single element high speed Master trip relay with mechanical flag and hand reset contacts (1 no.) d) Supplying multifunction meter digital three line back light LED type display of voltage, current, frequency power, power factor kVA, kWH, kVAR suitable for 3 Phase 4 wire LT network with IP 54 degree of protection and completely wired as required (3 nos.) e) Annunciator panel with suitable no. of windows (1 no) f) Cabinet Type Class 1 and 2 Combined Model SPD to arrest surges and over voltages in the power line due to lightning switching action etc. they must be installed in parallel to the power circuit (1no). Other items in complete as per drawing & specifications.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted HT panel with Copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as digital voltmeters, digital ammeters with selector switches, Multi-Function Meters, phase indicating LED lamps, necessary interlocks as required etc., complete with incidental civil & mechanical works and comprising of following majorly and other items in complete as per drawing & specifications; (Capacity of Panel: 11kV, 630A with 2 I/C, 1 B/C & 10 O/G +2 Bus PT + 2 Line PT) a) 11kV, 630A, 26.25 kA Vacuum Circuit Breaker Indoor type with CT and high-speed tripping relay. (For I/C & B/C, 3 Nos.) b) 11KV, 630A, 26.25 kA HT Indoor Single Panel Vacuum Circuit Breaker with CT complete as per specification (for Main Pumps, Aux. Transformers & spares, 10 Nos.) c) Motor & Feeder Protection Relays (CT Operated) Providing, installing numerical type motor or feeder protection relays for providing protection as per drawing e.g., REM 601 or similar (For I/Cs, B/C & O/Gs feeders, 13 Nos.) d) Multi Functions Meters - Flush type for Panel Board LED type, CT/PT, Voltage, Current, Frequency, Kilowatt, Kilo Volt Ampere, KVAR, KVAH, Run Hours, unbalance (V, A), Phase angles, TH–s - Class 1 With RS 485 Port (12 Nos.) e) Cabinet–Type Class 1 and 2 Combined Model SPD to arrest surges and over voltages in the power line due to lightening switching action etc. they must be installed in parallel to the power circuit. (12 Nos.) e) Cabinet–Type Class 1 and 2 Combined Model SPD to arrest surges and over voltages in the power line due to lightening switching action etc. they must be installed in parallel to the power circuit. (12 Nos.) f) Annunciator windows/Panel, flush mounting type (2I/C+10O/G+1B/C) Other items in complete as per drawing & specifications

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of 11 kV DG Set with NGR, AMF Panel and necessary accessories with complete. a).DG Set: 1500 kVA Diesel Generating Set with alternator of 1500 kVA minimum output continuous rating 3Phase, 11 kV, 50Hz, 0.8 PF AC totally enclosed air cooled multi cylinder diesel engine developing suitable BHP at 1500rpm with standard accessories, self-excited, self-regulated screen protected alternator with static excitation system running at 1500rpm as IS-4722 with voltage regulation +/- 5%. DG set to be TNPCB norms and CPCB-II Compliant, Residential silencer with exhaust pipe arrangements (insulated with glass wool inside the building) up to outside of room above roof level, standard GCB panel consisting of MFM energy meter withCT's and selector switch, voltmeter with selectors switch VCB, Generator Protection Relay, indicating lamps, fuses, and required 11kV grade XLPE armoured aluminium cable from alternator to GCB panel, battery bank, battery charger etc. External Fuel tank with all accessories (990 litre capacity). Both the engine & alternator direct coupled on a common fabricated steel base frame & mounted on anti-vibrating pads with VCB panel, C&R control panel & NGR/ NIS Panel comprising of switchgear, meters, indicators, relays, batteries & with necessary stack extension. b) AMF Panel: Microprocessor based AMF panel suitable for 1500 kVA capacity of 3 phase 11kV, 50Hz AC with all standard features, safeties etc. as per required specification.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning with complete Termination & Jointing with Indoor HT Termination Kits of various sizes of Aluminium conductor, XLPE, 11 kV armoured cable complete erected on trays or underground to be excavated at a depth of 1 m putting 6" layer of sand and covering the cable with brick, sand and route markers and refilling the earth to make good as directed of Cable from,

-

-

-

... More
• 11kV Metering/ RMG Unit to 11kV ICOG Isolation Panel in HT room • 11kV ICOG Isolation Panel to 11kV Main Switchgear Panel's Incomer-2&3 • 11kV DG Set to 11kV Main Switchgear Panel's Incomer-1 • 11kV Main Switchgear Panel's Outgoings to Auxiliary Transformer-1&2

-

-

-

... More
Aluminium conductor, XLPE, 11 kV, 3Core x 300 sq.mm armoured cable.

-

-

-

... More
IN INR

350

-

-

... More
IN USD

350

-

-

... More
IN JPY

350

-

-

... More
Indoor Termination Kit for 11 kV XLPE Screened 3 Core x 300 sq.mm cable.

-

-

-

... More
IN INR

16

-

-

... More
IN USD

16

-

-

... More
IN JPY

16

-

-

... More
11kV Main Switchgear Panel's Motor Feeder Outgoings to MV VFD Panels

-

-

-

... More
Aluminium conductor, XLPE, 11kV, 3Core x 150 sq.mm armoured cable

-

-

-

... More
IN INR

200

-

-

... More
IN USD

200

-

-

... More
IN JPY

200

-

-

... More
Indoor Termination Kit for 11kV XLPE Screened 3Core x 150 sq.mm cable

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning with complete Termination & Jointing with Indoor HT Termination Kits of various sizes of Aluminium conductor, XLPE, 3.3kV armoured cable complete erected on trench and trays to make good as directed.

-

-

-

... More
Aluminium conductor, XLPE, 3.3kV, 3Core x 150 sq.mm (From MV VFD Panel to Main Pump Motor)

-

-

-

... More
IN INR

200

-

-

... More
IN USD

200

-

-

... More
IN JPY

200

-

-

... More
3.3 kV Indoor Termination Kits and accessories 150 sq.mm.

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
Supply, delivery, Installation, Testing & Commissioning of floor mounted type 11/3.3 kV Variable Frequency Drive (MV VFD) panel suitable for the MV motor offered for operation in AC three Phase 50 Hz (+/-5%), 3.3 kV (+/-10%). The drive shall be Multi Pulse Multi Cell Architecture with dry type integrated Isolation/ Input/ Converter Transformer having minimum 6% impedance with suitable no. of pulses. Drive shall be of modular design to provide easy and fast maintenance. For 2 quadrant operation Drive shall have adequate configuration to meet IEEE 519 & IEC61000 standards. VFD should provide constant p.f. 0.95 Inductive (from 30% to 100% speed) without any additional reactor or capacitor. VFD shall inherently protect motor from high dv/dt stress, overcurrent protection at every load and all other motor protections. The MV VFD Panel shall be with IP42 enclosure with integrated forced air-cooling system. Overall Drive efficiency including transformer and other accessories shall be minimum 95% at 75% to 100% continuous loading. Necessary controls including LCD/ LED display, ammeters, voltmeters, switches, LED indicating lamps, selector switches and Start/ Stop push buttons etc. having inter-operability with PLC-SCADA system and all accessories in complete. MV VFD Panel for 3.3 kV, 350 kW, MV motors with all motor protections, CTs and other accessories. All items in complete shall be as per drawing & specifications.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supplying, delivery, Installation, Testing & Commissioning of dust and vermin proof local Push Button station fabricated in FRP sheet enclosure with hinged door erected near the Main pump set for Switching the pump set "ON" and "OFF" with 1 No. "ON", 1 No. "OFF" and 1 No. Emergency "EM" push buttons ("EM" push button shall be Mushroom type lockable in "OFF" position), with LED type panel board indicating lamps with required colour suitable for 220V, AC 50 Hz mounted on an angle or ISMC frame support at a convenient height for operating the push buttons and above the local MFL with provision for earthing including incidental civil/ mechanical works etc., complete.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Aux. Transformers of Outdoor type, Copper wound 11/0.433kV, 315 kVA, Transformer continuously rated for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45ºC by thermometer in oil and 50ºC by the resistance in winding after continuous run at full load rating, the transformer should have oil immersed winding having vector group Dyn11, HT side connected in Delta and LT side connected in Star with neutral brought out connected to provided separate earthing. The transformer shall have power terminal arrangement, bushing / cable end box on HT side and cable end box on LT side. 2 Nos. channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. The transformer should have following standard fittings. The OCTC should be suitable for minimum 50 operations per day. Transformer shall be of latest manufacturing standards as per amended IS specifications and losses below 955 Watts at 50% load, 2750 Watts at 100% load as per IS:1180 - 2014 energy efficiency level latest amendment-4 energy efficiency level – 2 (earlier efficiency level-3) and Off Load Tap Changer -10% to +5% in steps of 2.5% with marshalling box.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Erection, Testing and Commissioning of 415V Aux. DG Set with AMF Panel and necessary accessories with complete.

-

-

-

... More
a) DG Set: 75kVA Diesel Generating Set with alternator of 75kVA output continuous rating 3Phase, 415V, 50Hz, 0.8 PF AC totally enclosed air cooled multi cylinder diesel engine developing suitable BHP at 1500rpm with standard accessories, self-excited, self-regulated screen protected alternator with static excitation system running at 1500rpm as IS-4722 with voltage regulation +/- 5%. Both the engine & alternator direct coupled on a common fabricated steel base frame & mounted on anti-vibrating pads with standard control panel comprising of switchgear, meters, indicators, relays, batteries & with necessary stack extension. b) AMF Panel: Microprocessor based AMF panel suitable for 75kVA capacity of 3 phase 415V, 50Hz AC with all standard features, safeties etc. as per specification.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing and Commissioning of 415V (Low Voltage) Switchgear with necessary accessories with complete.

-

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V LV PMCC panel (800A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as CTs, voltmeters, ammeters with selector switches, Multi-Function meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following majorly and other items in complete as per drawing & specifications; I/C: 800 A, 4 Pole 50 kA, Microprocessor based, EDO Breaker (2 Nos.) B/C: 800 A, 4 Pole 50 kA, Microprocessor based, EDO Breaker (1 No.) O/G: 400A MCCB (TPN) (2 Nos.) O/G: 125A MCCB (TPN) (7 Nos.) O/G: 63A MCCB (TPN) (9 Nos.) O/G: 32A MCCB (TPN) (2 Nos.) O/G: DOL starter unit up to 5 HP confirming to IS 13947 and IEC609471 with a 32A MPCB, LPBS in each and all other accessories in complete (6 Nos.) Multi Functions Meters (MFM) – Flush type, LED type display for required parameters- Class 1 With RS 485 Port (2 Nos. for I/Cs). Other items in complete as per drawing & specifications.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor/ wall mounted 415V Motorized Operated Valves DB (125A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as CTs, voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following majorly and other items in complete as per drawing & specifications; I/C-125A MCCB (TPN) O/G: 16A MPCB with ON/OFF/TRIP Indication Lamps with all other accessories in complete (20 Nos.) Multi Functions Meters – Flush type for Panel Board LED type, With RS 485 Port (1 No.)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V Ventilation DB-1 (63A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following and as per drawing and specifications; I/C- 63A MCCB (TPN) (1 No.) O/G: 16A MPCB with ON/OFF/TRIP Indication Lamps with all other accessories in complete (18 Nos.) Multi Functions Meter – Flush type with all required parameters & features (1 No.)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V Ventilation DB-2 (63A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following and as per drawing and specifications; I/C- 63A MCCB (TPN) (1 No.) O/G: 16A MPCB with ON/OFF/TRIP Indication Lamps with all other accessories in complete (24 Nos.) Multi Functions Meter – Flush type with all required parameters & features (1 No.)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V Ventilation DB-3 (63A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required ,etc., complete with incidental civil & mechanical works and comprising of following and as per drawing and specifications; I/C- 63A MCCB (TPN) (1 No.) O/G: 16A MPCB with ON/OFF/TRIP Indication Lamps with all other accessories in complete (18 Nos.) Multi Functions Meter – Flush type with all required parameters & features (1 No.)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V Main Lighting DB (125A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following and as per drawing and specifications; I/C-125A MCCB (TPN) + RCCB (30 mA) (1 No.) O/G: 32A MCCB (TPN) (6 Nos.) O/G: 63A MCCB (TPN) (2 Nos.) Multi Functions Meter – Flush type with all required parameters & features (1 No.)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor mounted 415V ACDB-1 & 2 (125A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required etc., complete with incidental civil & mechanical works and comprising of following and other items as per drawing and specifications; I/C-125A MCCB (TPN) (1 No.) O/G: 32A MCCB (TPN) (10 Nos) Multi Functions Meter – Flush type with all required parameters & features (1 No.)

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Delivery, Installation, testing and commissioning of 415V Auto Power Factor Correction (APFC) Panel consists of power capacitor banks for power factor improvement, APFC relay suitable to operate on 415V, 3Ph, 50Hz A/C supply, with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as CTs, voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, etc., complete with incidental civil & mechanical works and comprising of following and as per drawing and specifications; Capacity: 140 kVAR each with 8 to 12 stages (a) I/C- 400A MCCB (TPN), 1 No. (b) Mixed Die Electric Capacitor with TNEB Test Certificate with accessories including Banking Conform to IS 2834. (c) 6 to 14 stage - sensitivity up to 50 milli Amp microprocessor based intelligent power factor correction relay, self analysing auto c/k setting according to targeted power factor setting, the relay shall have overload protection, no volt release etc. (d) Multi Functions Met–r - Flush type. Other items in complete as per drawing & specifications.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Delivery, Installation, testing and commissioning of floor/ wall mounted 415V Motorized Operated Valves DB (125A) with copper bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as CTs, voltmeters, ammeters with selector switches, energy meter, LED indicating lamps, necessary inter locks as required, etc., complete with incidental civil & mechanical works and comprising of following majorly and other items in complete as per drawing & specifications; I/C-125A MCCB (TPN) + RCCB (30 mA) (1 No.) O/G: 32A MCCB (TPN) (6 Nos.) O/G: 63A MCCB (TPN) (2 Nos.) Multi Functions Meters – Flush type for Panel Board LED type, With RS 485 Port (1 No.)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Lighting Distribution Board (For all indoor areas) - Industrial Type TPMCB DB with IP 54 Protection 8 Ways 3 Phase DB, Per Phase Isolation (PPI) suitable for Lighting with One (1) No. FP, 32 A MCB + Three No. (3) DP 40 A RCCB (30mA sensitivity) for each phase incoming and for outgoings as follows: (i) 16 A SP MCBs (C-Curve) - 12 Nos. (ii) 16 A TPN MCBs (C-Curve) - 4Nos.

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
SITC of 110V DC battery bank including MS/Teakwood battery stand, interconnect wiring, distribution board etc. as required complete in all respect of rating:

-

-

-

... More
110V DC, 120 AH Ni-Cd Battery Bank with Maintenance free battery cell bank & connecting wires, stand in complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
110V DC, 60A Automatic Thyristor control charger (with float cum boost battery charger) with all accessories like switches, measuring instruments, selector switches, LED Indications, Voltmeter, Ammeter etc. complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
DC Distribution Board with all accessories like switches, measuring instruments, selector switches, LED Indications, Voltmeter, Ammeter etc. complete. I/C-125A MCCB (TPN), 2 Nos. O/G: 32A MCCB (TPN), 3 Nos. O/G: 16A MCB (DP), 12 Nos. Other items in complete as per drawing & specifications.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning with complete Termination & Jointing of Aluminium conductor, XLPE/ PVC, 1.1kV armoured cable complete installed in approved trench/ on trays/ or underground as directed.

-

-

-

... More
1.1 kV, Aluminium conductor, XLPE / PVC insulated & armoured Power cable.

-

-

-

... More
3.5C X 240 Sq.mm (from Transformers, DG set to Incomers in PMCC)

-

-

-

... More
IN INR

350

-

-

... More
IN USD

350

-

-

... More
IN JPY

350

-

-

... More
3.5C X 120 Sq.mm (For APFC Panels)

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
3.5C X 70 Sq.mm (For MLDB, ACBDs, Chlorination and MOV DBs)

-

-

-

... More
IN INR

400

-

-

... More
IN USD

400

-

-

... More
IN JPY

400

-

-

... More
3.5C X 35 Sq.mm (For Ventilation DBs, Battery Charger, DCDB, Inst. SCADA and Street Light DBs)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
4C X 16 Sq.mm (For Indoor LDBs)

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
3C x 4 Sq.mm (Motors up to 5.5kW) copper conductor

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
3C x 6 Sq.mm (Motors from 7.5kW to 9.3 kW) copper conductor

-

-

-

... More
IN INR

350

-

-

... More
IN USD

350

-

-

... More
IN JPY

350

-

-

... More
3C x 16 Sq.mm (For Dewatering Pumps and Service Water Pumps)

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
4C x 10 Sq.mm (For All EOT Cranes, Receptacles)

-

-

-

... More
IN INR

800

-

-

... More
IN USD

800

-

-

... More
IN JPY

800

-

-

... More
1.1kV Copper Power & Control Cables with Cables, Termination kits, glands, lugs, straight thru joints etc. with all required accessories. All complete works.

-

-

-

... More
10C X 2.5 sq mm, Cu. Conductor (Transformer to PMCC, PMCC to APFC panel, Trf. To MV panel etc.)

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
12C x 2.5 sq.mm, Cu. Conductor (from VCB motor feeder to MV VFD Panel) (unarmoured)

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
4C X 2.5 sq mm, Cu. Conductor (For LPBS- 2 Runs, Street Light Poles JB)

-

-

-

... More
IN INR

1500

-

-

... More
IN USD

1500

-

-

... More
IN JPY

1500

-

-

... More
3C X 1.5 sq.mm, Cu. Conductor (For Axial Fans, JB to Street lights)

-

-

-

... More
IN INR

1000

-

-

... More
IN USD

1000

-

-

... More
IN JPY

1000

-

-

... More
3C X 4 sq.mm, Cu. Conductor (for MOVs)

-

-

-

... More
IN INR

1000

-

-

... More
IN USD

1000

-

-

... More
IN JPY

1000

-

-

... More
3 core x 2.5 sq.mm, Cu. Conductor (For Big Axial Fans)

-

-

-

... More
IN INR

1000

-

-

... More
IN USD

1000

-

-

... More
IN JPY

1000

-

-

... More
3Core x 2.5 Sq.mm, Cu. Conductor (DCDB to HT Switchgears etc.)

-

-

-

... More
IN INR

200

-

-

... More
IN USD

200

-

-

... More
IN JPY

200

-

-

... More
Supply, Installation, Testing & Commissioning of following sizes of FRP ladder type cable trays with rungs at span of 250 mm including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling/wall with suspenders etc., complete as per the specifications given in employers requirement.

-

-

-

... More
600 mm x 100 mm x 3 mm (for Power Cables)

-

-

-

... More
IN INR

400

-

-

... More
IN USD

400

-

-

... More
IN JPY

400

-

-

... More
450 mm x 100 mm x 3 mm (for Power Cables)

-

-

-

... More
IN INR

400

-

-

... More
IN USD

400

-

-

... More
IN JPY

400

-

-

... More
Supply, Installation, Testing and Commissioning of FRP perforated cable trays with cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc. complete and the tray should be fitted on the wall / Ceiling etc. complete as per the specifications;

-

-

-

... More
450 mm x 75 mm x 3 mm (for Power Cables)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
300 mm x 75 mm x 3 mm (for Power/ Control Cables)

-

-

-

... More
IN INR

400

-

-

... More
IN USD

400

-

-

... More
IN JPY

400

-

-

... More
150 mm x 75 mm x 3 mm (for Control Cables)

-

-

-

... More
IN INR

400

-

-

... More
IN USD

400

-

-

... More
IN JPY

400

-

-

... More
RCC Hume pipe, 1 m long, 200 mm dia with collars for Road crossings for Cable & Earth Strip crossing.

-

-

-

... More
IN INR

30

-

-

... More
IN USD

30

-

-

... More
IN JPY

30

-

-

... More
Supply, Installation, Testing and Commissioning of Lighting System with following major equipment, items as per scope, specification, and drawings.

-

-

-

... More
Supply of Lighting Luminaires

-

-

-

... More
SITC of 95W LED High Bay Luminaire with high power LED made of pressure diecast aluminium housing with powder coated, Supply Input voltage 120 - 270 V AC, P.F 0.90, high power LED's having efficacy 130 lumines/watt, System efficacy 100lm/W and junction temperature 70°C, with Ingress protection IP66, IK05, Driver surge protection 4KV, In house additional Surge protection ≥ 5KV with wide/ Narrow beam optics, THD10% at 110 Volts AC, driver efficiency 90%, CCT: 3000K - 5700K, minimum CRI70, The LEDs shall be of SMD type (not COB type). The luminaire supplier shall submit the LM79 and LM80 report of the luminaire from the approved NABL accredited laboratory, etc., complete. (For Pump House Low area).

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
SITC of 150W LED High Bay Luminaire with high power LED made of pressure diecast aluminium housing with powder coated, Supply Input voltage 120 - 270 V AC, P.F 0.90, high power LED's having efficacy 130 lumines/watt, System efficacy 100 lm/W and junction temperature 70°C, with Ingress protection IP66, IK05, Driver surge protection 4KV, In house additional Surge protection ≥ 5KV with wide/ Narrow beam optics, THD 10% at 110 Volts AC, driver efficiency 90%, CCT: 3000 K – 5700 K, minimum CRI 70, The LEDs shall be of SMD type (not COB type). The luminaire supplier shall submit the LM79 and LM80 report of the luminaire from the approved NABL accredited laboratory, etc., complete. (For Pump House High area).

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
SITC of IP20 surface round LED downlighter compatible with system wattage12W-18W and luminaire lumens not less than 1200 lumens. The system efficacy shall be 100 lm/W. The housing shall be PC engineered with diffused optics with polycarbonate diffuser for better distribution of light. LED make that satisfies IEC62471 Photobiological / RoHS Standards with and LED Efficacy of 150 lm/W, Colour Temperature – 6500 K or Higher with LED binning as per ANSI Bin C78.377A, 120 Deg LED Beam Angle, CRI 80, Life of LED as per L70 30000 burning hours, Ambient temp - 0 to 50 Deg C, Driver efficiency 85%, THD 15%, Power factor 0.95, Inbuilt Surge protection in CM ≥ 2.0KV, LED Driver with Voltage range 150-270V AC and Safety Extra Low Voltage Safe level 60V DC as per IEC standard, Electrical Safety with Class 1 Insulation. Driver shall be potted driver with three terminals of P, L, E and both driver and luminaire shall be BIS compliance. (For Toilets other indoor rooms)

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
SITC of 4' LED batten with wattage 34W and System Efficacy & System lumens of ≥ 117 lm / W 4000 lm respectively. The type of LED shall be SMD type mounted on MCPCB which is mechanically fixed (no glue pasting) with CCT of 6500 K and CRI 80. The housing material shall be aluminium rugged for industrial use. The life of batten shall be 50000 hours at L70. The LED shall be of SDCM 5. The IP rating of the luminaire shall be IP40. The ambient temperature shall be 0-45 deg C. The luminaire optical element shall be UV protected polycarbonate. The luminaire shall be operable from 140 - 270V AC with PF 0.9 and THD 10%. The driver shall be encapsulated type and placed within the luminaire. The driver shall be with in-built surge protection of 4kV. Drivers shall be flicker free and complies to IEEE P1789 standard; ripple 5%. The efficiency of driver shall be 90%. The luminaire shall be BIS approved and carry “R” number. EMI/EMC Compliance. (For Electrical Room, AC room, Control Room, Storeroom, Transformer rooms, DG room, office room etc.)

-

-

-

... More
IN INR

150

-

-

... More
IN USD

150

-

-

... More
IN JPY

150

-

-

... More
SITC of IP65, IK08 4' LED luminaire with special application luminaire shall be designed to provide undisrupted lighting for dusty and humid indoor application. The luminaire shall be with all-weather extruded aluminium housing and highly efficient electronics with LED system to offer long useful life even in adverse application and environmental conditions. The luminaire shall be with Co-extruded polycarbonate housing and mounded end caps. The system wattage shall be 36W with system lumens of 4400 lumens and system efficacy of 120 lm/W. LED make: that satisfies IEC 62471 Photobiological/RoHS Standards with and LED Efficacy of 150 lm/W, Colour Temperature – 6500 K or Higher with LED binning as per ANSI Bin C78.377A, 120 Deg LED Beam Angle, CRI 80, Life of LED as per L70 50000 burning hours, Ambient temp-0 to 50 Deg C, Driver efficiency 85%, THD 10%, Power factor 0.95, Inbuilt Surge protection in CM 4KV, Constant Current - Constant Voltage LED Driver with APFC Construction, high voltage cutoff & auto restart @ 320V, phase to phase 440V protection up to 8hrs, LED Driver Voltage range 150-270V AC and Safety Extra Low Voltage Safe level 60V DC as per IEC standard, Electrical Safety with Class 1 Insulation. (For Battery Room etc.)

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Pole Mounted Hybrid Solar Street lights (with all accessories) Supply of all-in-one integrated LED hybrid solar streetlight consists of solar photovoltaic module, battery, battery management system, control electronics, LED driver, microwave sensor, Auto changeover switch, Inter-connecting cables and pole mounting piece integrated into the luminaire as a single unit. Solar streetlight with IP65 ingress protection having a system wattage of 60-70W with 8500 lumens (140 lm/W) with 100Wp high efficiency monocrystalline solar panel, highly efficient MPPT based charge controller and 12.8 V, 42 Ah Lithium Ferro Phosphate (LiFePO4) battery with proper battery management system. LED lumen efficacy shall be at least 170 lm/W and LED driver should have 90% efficiency. Typical correlated colour temperature should be 5700 K with CRI 70. It should have microwave sensor-based movement detection and dim level adjustment to effectively extend the working time. AIO should be onsite configurable via a handheld remote. The luminaire should be housed in IK 08 impact resistance certified aluminium with polycarbonate lens cover. The luminaire shall have a specially designed adjustable pole mounting piece for optimal light distribution.

-

-

-

... More
IN INR

25

-

-

... More
IN USD

25

-

-

... More
IN JPY

25

-

-

... More
SITC of 48W LED Peripheral light Luminaire made of pressure diecast aluminium body with powder coated, having protective toughened glass, Supply Input voltage 120 - 270 V AC, P.F 0.90, high power LED's having efficacy 120 lumines/watt, System efficacy 95 lm/W and junction temperature 70°C, with Ingress protection IP65, Driver surge protection 4KV, external Surge protection ≥ 5KV with optics distribution Type II medium, THD 10% at 110 Volts AC, driver efficiency 90%, CCT: 3000 K – 5700 K, minimum CRI 70, etc., complete.

-

-

-

... More
IN INR

40

-

-

... More
IN USD

40

-

-

... More
IN JPY

40

-

-

... More
SITC of 32Amps Receptacle on separate board with 32A TPN MCB etc. of approved make in suitable sheet enclosure, including earthing as per specification, including accessories all complete works.

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
SITC of LED Emergency Light fixture with 1 no. 1 feet (30 cm) single tube 9/11 W with M.F. SLA rechargeable battery with 3 hrs. of back up.

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
Fixing Charges of Fittings

-

-

-

... More
Fixing all types & all capacities LED fittings Indoor on the wall /ceiling/rafters/gridders using 23 / 0.76" twin twisted PVC insulated wires.

-

-

-

... More
IN INR

234

-

-

... More
IN USD

234

-

-

... More
IN JPY

234

-

-

... More
Supply & fixing of 50mm dia. FRP Pipe bracket up to 1.5 m long for fixing LED street light fittings (peripheral) of all capacities on rail/RCC/Wall, using suitable clamps, bolts, nuts and wiring etc. complete. (Peripheral lights)

-

-

-

... More
IN INR

40

-

-

... More
IN USD

40

-

-

... More
IN JPY

40

-

-

... More
Supply & erection of FRP Tubular Pole 8 m free standing single arm bracket, continuously structured pole with FRP base plate of suitable size as per IS & IEC standards with specifications mentioned in the employer’s requirement. The pole should be Fiberglass Reinforced Plastic/ polymer.

-

-

-

... More
IN INR

25

-

-

... More
IN USD

25

-

-

... More
IN JPY

25

-

-

... More
SITC of Automatic Street Light Control Panel with Optical Micro Sensor, Low voltage / High voltage trip and reset, operating voltage 150 - 280V AC, 50 HZ with suitable SMC enclosure of IP 54 protection, MCBs and contactor suitable to control the load of 5kW of single-phase load with necessary clamping arrangements.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
SITC capacitor type 1200mm high breeze ceiling fan with regulator (on switch board) ceiling fan complete with down rod blades, shackle canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply, conforming to IS: 374-1979 and with double ball bearing system.

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Circuit & Point Wiring for Switchboard, lighting, fan circuits & sockets in complete.

-

-

-

... More
Primary Point (Circuit Wiring from Indoor lighting LDBs to Switchboards & Power Sockets Circuit maximum 10 meters in length)

-

-

-

... More
Circuit wiring for lighting panel/ distribution board to modular switch box with 4 sq.mm PVC insulated Cu conductor cable of approved make in surface or concealed rigid PVC conduit of suitable size, including paint etc. as required as per specification, including switch, ceiling rose, PVC flush box etc., all complete works.

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
Point wiring for 3 pin/ 5 pin 20Amps Socket outlet point on separate board 4 sq.mm PVC insulated Cu conductor cable, 20A switch etc. of approved make in suitable size of the PVC conduit including earth continuity conductor in surface or concealed wiring system as per specification, including switch and socket all complete works.

-

-

-

... More
IN INR

15

-

-

... More
IN USD

15

-

-

... More
IN JPY

15

-

-

... More
Secondary Point (from primary tapping point to Light, fan and plug points) Wiring with 2.5 sq.mm PVC unsheathed copper single core in suitable PVC conduit pipe for lighting with joint box and switch box with continuous earth connection by 14 SWG TC wire. (1 No.) Run of 2 of 2.5 sq.mm PVC unsheathed copper SC cable in PVC conduit pipe for mains continuous earth connection by 14 SWG TC wire (3 Nos.)

-

-

-

... More
Short point (not exceeding 3m)

-

-

-

... More
IN INR

150

-

-

... More
IN USD

150

-

-

... More
IN JPY

150

-

-

... More
Medium point above 3m and up to 6m

-

-

-

... More
IN INR

170

-

-

... More
IN USD

170

-

-

... More
IN JPY

170

-

-

... More
Long point above 6m and up to 10m

-

-

-

... More
IN INR

170

-

-

... More
IN USD

170

-

-

... More
IN JPY

170

-

-

... More
Plug, Sockets in Modular Enclosure without MCBs

-

-

-

... More
6/10A Single Phase

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
20A Single Phase

-

-

-

... More
IN INR

15

-

-

... More
IN USD

15

-

-

... More
IN JPY

15

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Earthing systems with necessary masonry works in complete.

-

-

-

... More
Earth electrode for grounding of transformers & DG sets Neutral using copper Plate Earthing connected to 40 mm dia 3 meter long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of suitable size with a cast iron cover. The electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts as per IS:3043.

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
Earth Electrode for grounding of all Equipment and machines etc. using 40 mm dia 3 meter long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of suitable size and cast-iron cover. The electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. 25 kgs. of carbon-based environment friendly backfill compound and suitable clamp.

-

-

-

... More
IN INR

30

-

-

... More
IN USD

30

-

-

... More
IN JPY

30

-

-

... More
Supplying, Installation, Testing, Commissioning and running of GI and Copper strips earthing conductor for grounding connections, using necessary fixing materials as required, laying between earth pit and equipment.

-

-

-

... More
50 x 6 mm Copper Flat (Aux Trf. & DG neutral etc.)

-

-

-

... More
IN INR

250

-

-

... More
IN USD

250

-

-

... More
IN JPY

250

-

-

... More
50 x 10 mm GI (PCC, MCC Panels, Main Motors, Main Grid etc.)

-

-

-

... More
IN INR

1000

-

-

... More
IN USD

1000

-

-

... More
IN JPY

1000

-

-

... More
50 x 6 mm GI (MCC Panels, Main Motors etc.)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
25 x 6 mm GI (Cable Trays, LDBs, MLDB etc.)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
25 x 3 mm GI (Valve DBs, Fan DBs, Street Lighting etc.)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
Supplying, Installation, Testing, Commissioning and running of GI wire for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas, spacers etc.

-

-

-

... More
8 SWG (Receptacles)

-

-

-

... More
IN INR

500

-

-

... More
IN USD

500

-

-

... More
IN JPY

500

-

-

... More
6 SWG (Small Motors)

-

-

-

... More
IN INR

800

-

-

... More
IN USD

800

-

-

... More
IN JPY

800

-

-

... More
Supply, Installation, Testing & Commissioning (SITC) of External Lightning Protection System with all accessories in complete.

-

-

-

... More
SITC of Vertical Air Terminals: Supply & Installation of air termination rod of 3m length of material AlMgSi of diameter ø 16/10 mm crimped on both the ends (Tapered Type). The rod shall be mounted with stone and all fixing accessories, and Stainless-steel Folded clamp to connect metal parts with the 8mm Aluminium conductor to meet the requirement of IS/–EC - 62305-3. Vertical air terminal is selected as per Angle of Protection method conforming to IS/IEC 62305-3 & NBC-2016. Test Parameter: Mechanical Load Test for individual aluminium alloy rods - 120 to 280 N/mm², Salt Spray Test-No sign of corrosion, Tested as per IEC 62561-1&2.

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
SITC of Air Termination System: Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination system. Cross sectional area of conductor should be min. 50 mm². Conductor is tested for Lightning Impulse current of 100 kA for 10/350 μs, Electrical, Resistivity, Tensile strength & Corrosion test as per IEC 62561-2. Parapet conductor holder for fixing on the Parapet wall for clamping 8 mm dia Aluminium alloy round conductor. Terrace conductor holder shall be considered in the flat surface. Folded clamps/ Metal roof holder considered for Metal sheets for clamping min. 8 mm dia Aluminium alloy round Conductor. Stainless steel cross connector for connecting minimum 8 mm aluminium conductor at cross/Tee junction. Expansion Piece with connector to compensate the expansion and contraction of Solid Round Al. conductor during temperature variations. Folded clamp consider to bond the metal parts. All the Lightning Protection components are tested as per IEC 62561-1&2.

-

-

-

... More
IN INR

400

-

-

... More
IN USD

400

-

-

... More
IN JPY

400

-

-

... More
SITC and run of min. 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in Down conductor system. Cross sectional area of conductor should be 50 mm². Conductor is tested for Lightning Impulse current of 100 kA for 10/350 μs, Electrical Resistivity, Tensile strength & Corrosion test as per IEC 62561-2. Parapet conductor holder for fixing on the Side wall for clamping 8 mm dia Aluminium alloy round Conductor in RCC building. Lightning counter is required in the building, and it will record number of lightning Strike in the building with date and time. All the Lightning Protection components are tested as per IEC 62561-1& 2.

-

-

-

... More
IN INR

120

-

-

... More
IN USD

120

-

-

... More
IN JPY

120

-

-

... More
SITC of Stainless-Steel Test Joint/ Link with enclosure to interconnect between min. 8 mm Al. round conductor to 10 mm copper bonded round conductor used to disconnect the earth termination system to enable measurement of resistance. Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1.

-

-

-

... More
IN INR

15

-

-

... More
IN USD

15

-

-

... More
IN JPY

15

-

-

... More
SITC of maintenance free Supply of non-corrosive 10 mm dia Copper bonded round conductor used for Earth termination in the soil and concrete and it is tested for short circuit test, Electrical resistivity, Tensile strength. Conductor holder is fixed on the Side wall of the building. All the Lightning Protection components are tested as per IEC 62561-1& 2.

-

-

-

... More
IN INR

65

-

-

... More
IN USD

65

-

-

... More
IN JPY

65

-

-

... More
Supply of UL listed Copper bonded rod of 254 microns coating thickness and 3.048 m length can be used as Earthing. The diameter of the rod shall be 14.2mm. Earth rod clamp of required size should be made up of stainless steel. Earth enhancement compound of 25kg producing low resistance below 1 Ω m of an earth termination system. Material of the earthing enhancing compound shall be chemically inert to subsoil. It shall not pollute the environment. The compound shall be tested and certified as per IEC 62561-7. Earth Chamber Should have an outer dimension of 290 mm x 290 mm x 153 mm made of GFP material. Flush Mounted, removable, and lockable cover of the earth pit should be able to withstand 60 kN. Lightning Protection components are tested as per IEC 62561-1 & 2.

-

-

-

... More
IN INR

15

-

-

... More
IN USD

15

-

-

... More
IN JPY

15

-

-

... More
Supply, Installation, Testing and commissioning of safety procedures for Electrical Equipments as per scope, specification and drawings for following items,

-

-

-

... More
2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS

-

-

-

... More
IN INR

50

-

-

... More
IN USD

50

-

-

... More
IN JPY

50

-

-

... More
Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms

-

-

-

... More
IN INR

25

-

-

... More
IN USD

25

-

-

... More
IN JPY

25

-

-

... More
Hand Gloves 11KV Grade

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
First Aid Box complete with all First Aid Medicines.

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Shock Treatment Chart fixed in glass frame

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Danger Board as required by the Electrical Authorities. (Medium Voltage)

-

-

-

... More
IN INR

30

-

-

... More
IN USD

30

-

-

... More
IN JPY

30

-

-

... More
Danger Board as required by the Electrical Authorities. (High Voltage)

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Teak Wood Ladder- 5 m Height

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Earth Discharge Rod (3 Nos. RYB)

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Earthing Truck for 11 kV VCB Panel (Cable Side)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Earthing Truck for 11 kV VCB Panel (Bus Side)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Tools & Plant Machineries

-

-

-

... More
Live Line Tester- Connector Screwdriver 901 Taparia Make or equivalent

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Digital Multimeter CE Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Digital Tong Tester CE Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Electrical Air Blower

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Digital Tachometer

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Hand Crimpling Tool 8"

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
DE Spanner set 6 to 32 Jhalani Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Rings spanner set 6 to 32 Jhalani Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Hacksaw Frame with Blade

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
15” Screw Spanner Taparia Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Lever Type Grease Gun

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
200mm Cutting Plier Taparia Make or equivalent

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
200mm Screwdriver 825 Taparia Make or equivalent

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
300mm Screwdriver 829 Taparia Make or equivalent

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
800 gm Ball Pane Hammer with Handle Taparia Make

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
6” Chain wrench best India make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
8” Chain Wrench Best India Make or equivalent

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Connector Screwdriver 901 Taparia Make

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
400mm Screwdriver 930 Taparia Make

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
12” Bearing Puller

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
12” Screw Spanner

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Crowbar 5”

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
1” Cold Chisel

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Pipe Wrench 24” Jhalani Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Pipe Wrench 14” Jhalani Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Flat rough File Scissors Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Flat smooth File Scissors Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Round File Rough Scissors

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Round File Smooth Scissors Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Half Round File Rough Scissors Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12” Half Round File Smooth Scissors Make

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Mechanical Equipment (Pump with piping and valves)

-

-

-

... More
Supply, Installation, Testing and Commissioning of Single stage, Double Suction, Horizontal Split Case Centrifugal Pumps confirming to IS: 5120 and IS: 9137 Pumps of 3645 cum/hr. capacity at 25 M head including all losses, maximum 1000 RPM (syn) with Corocoat/equivalent coating inside the casing to be provided for increase pump life & efficiency, complete with all accessories such as Base frame, flexible Coupling, Mating flanges with necessary Bolts and gaskets.

-

-

-

... More
1. Shut off head: Min 120% of the specified head. 2.The pumps including working pumps and standby pumps shall be automatically operated in sequence such that no pump shall run continuously for longer duration. This shall be achieved through a control system.

-

-

-

... More
3. The duty condition of the pump should be to the left of the best efficiency point and closer to best efficiency point.

-

-

-

... More
4. Minimum guaranteed efficiency of horizontal split case pumps shall be 88% without negative tolerance. 5. The pump is required to work at an altitude of Mean Sea Level and at a maximum ambient temperature of 50 degree Centigrade.

-

-

-

... More
6. Four working pumps in parallel combination should be able to deliver minimum of 350 MLD at the rated head.

-

-

-

... More
7. Contractor to carry out sump model study & CFD analysis of the pump.

-

-

-

... More
Casing: SG Iron IS 1865 Gr. 500/7/GGG50 or 400/15/GGG40

-

-

-

... More
Impeller: Stainless Steel: ASTM A 743 CF8M Shaft: Stainless Steel: BS 970 Gr. 431 S29/ASTM A 276 Gr.431

-

-

-

... More
Casing Rings: Stainless Steel: ASTM A743 CA15 Impeller Ring: Stainless Steel: ASTM A743 CA15 Shaft Sleeve: Stainless Steel: ASTM A743 CA15 (Minimum hardness = 400 BHN) Mechanical Seal: Silicon Carbide v/s Silicon Carbide or Tungsten Carbide v/s Tungsten Carbide Note: There shall be difference of 50 BHN hardness between Casing and Impeller rings. Fasteners, Anchors bolts, Foundation Bolts etc. both in wet and dry areas: Stainless Steel: 316, - Base Plate: MS with epoxy coated. Bearing Life: One Lakh working hours (L10), Corocoat coating inside the casing to be provided for increase pump life & efficiency, Pump shall be Painted with Food Grade Epoxy inside and Outside the Pump casing and it should be 250 Microns. High quality corocoat or equivalent coating to be provided in casing an impeller for long term corrosion protection and efficiency improvements.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of VFD Compatible, Horizontal Foot Mounted Squirrel Cage Induction Motor minimum 350 kW, 1000 rpm (syn), Efficiency 95% (minimum), compatible for pumps of item no. (21)

-

-

-

... More
Specific requirements for motors: Operating condition:

-

-

-

... More
(i) Induction motor shall be TEFC/CACA type suitable for continuous operation and operating on 3 Ph, 50 Hz. 3.3kV supply.

-

-

-

... More
(ii) The motor is required to work at an altitude of 10 m above MSL and at a maximum ambient temperature of 50 degree centigrade.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Installation, lowering, laying & Jointing, testing, commissioning of Spirally/Longitudinal welded MS pipes (Fe-410 grade) conforming to IS 3589-2001, perfect linking, welding of joints and Flange Joints to correct position including cost and conveyance of pipes and materials with all lead and lifts, cost of all labour and giving satisfactory hydraulic test as per IS 3589 - 2001 for test pressure and working pressure both at factory and site etc., complete as per detailed specifications with Internal food grade epoxy coating 406 microns of approved make & External food grade epoxy coating 406 microns/Coal Tar Enamel Coating & Wrapping of 4 mm thk, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. The Rates are including rubber insertion or any equivalent to the required specifications with MS Bolts and nuts for Flange Joints complete (Contractor will make his own arrangement for procuring water for testing).

-

-

-

... More
1829 mm with 16 mm thk for flowmeter bypass arrangement

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
1829 mm with 16 mm thk on Common Delivery header

-

-

-

... More
IN INR

100

-

-

... More
IN USD

100

-

-

... More
IN JPY

100

-

-

... More
1829 mm with 16 mm thk Inlet of GLR

-

-

-

... More
IN INR

150

-

-

... More
IN USD

150

-

-

... More
IN JPY

150

-

-

... More
MS Blind flange of 1800 mm diameter for inlet of GLR to New Booster PS

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
1626 mm with 14 mm on Common Suction header

-

-

-

... More
IN INR

16

-

-

... More
IN USD

16

-

-

... More
IN JPY

16

-

-

... More
MS Blind flange for 1600 mm diameter pipe

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Epoxy Coated MS Puddle Flange for 1800 mm diameter MS pipe

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Epoxy Coated MS Puddle Flange for 1600 mm diameter MS pipe

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Epoxy Coated MS Puddle Flange for 900 mm diameter MS pipe

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
1016 mm with 8.8mm thick for OVERFLOW pipe at UGT of PORUR WDS

-

-

-

... More
IN INR

29

-

-

... More
IN USD

29

-

-

... More
IN JPY

29

-

-

... More
914 mm with 10 mm thk on individual Suction side of each pump

-

-

-

... More
IN INR

90

-

-

... More
IN USD

90

-

-

... More
IN JPY

90

-

-

... More
813 mm with 10 mm thk on individual delivery side of each pump

-

-

-

... More
IN INR

90

-

-

... More
IN USD

90

-

-

... More
IN JPY

90

-

-

... More
323.9 mm with 7 mm thk on (Scour Valve)

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
323.9 mm with 7 mm thick for installing on Pressure Release Valve and Air Release Valve line at 1800 mm NB common header.

-

-

-

... More
IN INR

20

-

-

... More
IN USD

20

-

-

... More
IN JPY

20

-

-

... More
Supply, Installation, rolling, lowering, laying & Jointing, testing, commissioning of MS specials confirming to IS 1916/ 7322: 1985 with latest amendments.

-

-

-

... More
IN INR

200

-

-

... More
IN USD

200

-

-

... More
IN JPY

200

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Long Body, Double Flanged, Double eccentric Resilient seated Butterfly valve with counter flanges confirming to BS EN 593/BS 5155/IS 13095 MOC: Body & Disc, Flange : DI IS 1865 Gr.500/7/GGG50/40, Shaft: Stainless Steel - ASTM A 276 Gr. 431, Seal Retaining Ring : Stainless Steel - ASTM A 743 CF8M, Body Seat Face : ASTM A 743 CF8M / Nickel welded with Electrically operated microprocessor based integral starter type actuator having manual override with all indications, switches, controls and accessories in complete with suitable bypass SS 316 piping & valve arrangement. All fasteners shall be AISI SS 316.

-

-

-

... More
1800 mm PN 10 at Inlet of GLR

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
1800 mm PN 16 at Common Delivery Header

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
1600 mm PN 10 at Common Suction Header

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of DI Rising spindle metal seated sluice valves as per BS 5163-89/IS 14846-2000/DIN 3202 F4 or its latest amendment. Body, Bonnet & Wedge in DI IS 1865 Gr.500/7/GGG50/GGG40, Body & Wedge Rings in Bronze/ SS304, Spindle in SS 431/420, Fasteners in SS316 with Electrically operated microprocessor based integral starter type actuator having manual override with all indications, switches, controls and accessories in complete with including inside food grade Epoxy powder coating minimum 250 micron.

-

-

-

... More
900 mm PN 10 on Pump Suction Header

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
800 mm PN 16 on Pump Discharge Header

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Ductile Iron, Rising spindle, metal seated, Sluice valves as per BS 5163-89/IS 14846-2000/DIN 3202 F4 or its latest amendment. Body, Bonnet & Wedge in Ductile Iron IS 1865 Gr.500/7/GGG50/GGG40, Body & Wedge Rings in Bronze/ SS304, Spindle in SS 431/420, Fasteners in SS316 with Electrically operated microprocessor based integral starter type actuator having manual override with all indications, switches, controls and accessories in complete with including inside food grade Epoxy powder coating minimum 250 micron.

-

-

-

... More
300 mm PN 16 on Common header for Scour valve arrangement

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
200 mm PN 16 on Common header for Pressure relief valve isolation arrangement

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
300 mm PN 16 for Bypass of 1800 mm Butterfly Valve on Common Discharge Header

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
300 mm PN 16 for Bypass of Butterfly Valve on 1600 mm Common Suction Header

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
200 mm PN 16 on Common header for Kinetic Air relief valve isolation arrangement

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
100 mm PN 16 manual Sluice Valve for Bypass of 900 mm on Individual Pump suction line

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
80 mm PN 16 manual sluice valve for Bypass of each 800 mm discharge line sluice Valve

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Ductile Iron Double flanged Dual plate check valve conforming to API 594 with latest amendments as detailed below of following diameters and types and conveying to work site, loading, unloading, stacking etc. complete with counter flanges as per BS 5163-89/IS 14846-2000/DIN 3202 F4 or its latest amendment. with including inside food grade Epoxy powder coating minimum 250 micron.

-

-

-

... More
1800 mm PN 16 at Common Header of Pumps

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Ductile Iron D/F Tilting disc Swing Check Valves Slanted seated with maximum swing. Body and Disc of ductile cast iron GGG-40/SG-400/15 or GGG-50/SG-500/7, Shaft of stainless steel - SS: 316, Shaft bearing of zinc free bronze, Body Seat Face & Disc Face with SS304/ Integral nickel-chromium overlay welding and micro finished with including inside food grade Epoxy powder coating minimum 250 micron.

-

-

-

... More
800 mm PN 16 at Discharge Header of Pumps

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of SS 304 Expansion Bellows of Flange Ends with necessary mating flanges, bolts & Gaskets for Dismantling purpose with including inside food grade Epoxy powder coating minimum 250 micron.

-

-

-

... More
1800 mm PN 10 at Inlet of GLR

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
1800 mm PN 16 at Common Delivery Header

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
1800 mm PN 10 for flowmeter bypass arrangement

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
1800 mm PN 10 for Inlet of GLR to New Booster PS

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
1600 mm PN 10 at Common Suction Header

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
900 mm PN 10 on individual Suction side of each pump

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
800 mm PN 16 on individual Discharge side of each pump

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Surge anticipating Relief valves against power failure surges or pressure waves caused by velocity changes, quick opening relief easily adjustable pressure setting flanges as per BS 5163-89/IS 14846-2000/DIN 3202 F4 or its latest amendment.

-

-

-

... More
200 mm PN 16 on Common header for Pressure relief valve arrangement.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Tamper proof DI single chamber air release valves with pressure range from PN 1.0 to 2.5 with body and cover made of Ductile Iron of Grade GGG 40 or equivalent grade conforming to IS 1865 with Food Grade Epoxy Powder coating (EP-P) inside and for outside of colour blue RAL 5005.

-

-

-

... More
200 mm PN 16 both on Common header for Air release valve arrangement

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of MS fabricated supports & chequered plates for pipeline, Ladder & platforms for valve and pump operation & maintenance and other Equipments.

-

-

-

... More
IN INR

200

-

-

... More
IN USD

200

-

-

... More
IN JPY

200

-

-

... More
Air Conditioning & Ventilation system

-

-

-

... More
Supply, Installation, testing & Commissioning of Heavy-Duty Ventilation Fans with bracket blades and Bird cowl arrangement Group "A" Required dia and sweep with 1440 RPM 415V or 230V, 50Hz, AC supply to provide suitable Air changes per hour for different Areas.

-

-

-

... More
Heavy Duty Ventilation Fan 1.5 kW

-

-

-

... More
IN INR

18

-

-

... More
IN USD

18

-

-

... More
IN JPY

18

-

-

... More
Heavy Duty Ventilation Fan 1.1 kW

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
Heavy Duty Ventilation Fan 0.75 kW

-

-

-

... More
IN INR

18

-

-

... More
IN USD

18

-

-

... More
IN JPY

18

-

-

... More
Heavy Duty Ventilation Fan 0.37 kW

-

-

-

... More
IN INR

14

-

-

... More
IN USD

14

-

-

... More
IN JPY

14

-

-

... More
Heavy Duty Ventilation Fan 0.25 kW

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Heavy Duty Ventilation Fan 0.12 kW

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Forced Ventilation system for Chlorination Building in case of leakage of Chlorine as per specification.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Erecting, Testing, commissioning of Split Air Conditioner (1.5 Ton BEE 5- Star Rating Inverter type) (2W+1S)

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Energy Efficient Air Conditioning System for cooling of VFD panels minimum capacity 32 TR (Central AC/Chiller/Package/VRF) with ducting and all accessories.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
EOT CRANE

-

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of 7.5 Ton Double Girder type fully electrically operated EOT crane with electrically operated hoist class II duty geared travelling trolley with min long travel 38 meter, span 11.30 meter, lift 10 meter complete with long travel rail track (40 mm sq. bar) moving or cross girder, all three motions electrically operated by suitable rating motor IP 54, control panel & down pendant control block, brake, safety device, cable from motor to starter panel & other required accessories & tested to 50% overload etc. comp. as per site requirement.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of 15 T capacity Double Girder type fully electrically operated EOT crane with electrically operated hoist class II duty geared travelling trolley with 7 (seven) m lift complete with long travel rail track (50 mm sq. bar) moving or cross girder, all three motions electrically operated by suitable rating motor IP 54, control panel & down pendant control block, brake, safety device, cable from motor to starter panel & other required accessories & tested to 50% overload etc. complete as per site requirement.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Dewatering System & Sump drainage arrangement

-

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of submersible centrifugal sewage non-clog pumps, vertical spindle type pump, wear resistance with submersible motor for the various duty conditions as stated in the specification. Pump shall be capable of handling min 100 mm solid size with sewage specific gravity of up to 1.05.

-

-

-

... More
Discharge up to 20 m3/hour @ 15 m head

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of DI D/F Gate (sluice) valves (Soft Seated) resilient seated soft sealing gate valves (sluice valves) with body bonnet of ductile cast iron of grade GGG40 or equivalent grade, with pressure rating PN 10/16.

-

-

-

... More
100 mm dia for delivery Isolation Valve PN 10 (Individual Delivery Side of pumps and Common header of Pumps).

-

-

-

... More
IN INR

4

-

-

... More
IN USD

4

-

-

... More
IN JPY

4

-

-

... More
Manufacture, Supply and Delivery of DI D/F Slanted seat Swing Check Valve. Body of ductile cast iron of Grade GGG-40 or equivalent grade and disc of ductile cast iron GGG-40 or equivalent grade.

-

-

-

... More
100 mm dia for delivery Isolation Valve PN 10 (Individual Delivery Side of pumps)

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of 100 mm P.N 10 of DI flanged pipe confirming to IS 8329:2000 with latest amendments with Cement Mortar Lining (CML) with Portland Slag Cement as per IS 455:1989 and Metallic Zinc Coating.

-

-

-

... More
IN INR

40

-

-

... More
IN USD

40

-

-

... More
IN JPY

40

-

-

... More
Service water Pump set Arrangement

-

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of Centrifugal Monobloc Pump set 350 LPM, 20 METER HEAD conforming to IS 9079 operating at 2900 RPM with CI impeller pump casing: Cast Iron IS 210 FG Gr.260, Impeller: Bronze IS 318 LTB2, Shaft: SS 410.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Providing and fixing in position 50 MM G.M GATE VALVES AS PER IS BS 5154.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Providing and fixing in position 50 mm nominal bore non-return valve.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying, Laying, jointing, testing and commissioning of GI pipes conforming to IS 1239:1990 with latest amendments including fixing collars, elbows, tees, gland cocks and other fittings.

-

-

-

... More
50 mm dia GI pipe (MEDIUM) AS PER IS 1239/PART I/2004

-

-

-

... More
IN INR

80

-

-

... More
IN USD

80

-

-

... More
IN JPY

80

-

-

... More
50 mm dia Elbow

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
50 mm dia Tee

-

-

-

... More
IN INR

5

-

-

... More
IN USD

5

-

-

... More
IN JPY

5

-

-

... More
50 mm dia Nipple

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
50 mm dia Socket

-

-

-

... More
IN INR

8

-

-

... More
IN USD

8

-

-

... More
IN JPY

8

-

-

... More
50 mm dia Union

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Firefighting equipment

-

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of 5KG capacity ISI marked dry chemical powder fire extinguisher with initial charges with wall mounting bracket, ready for use (TS 2678).

-

-

-

... More
IN INR

10

-

-

... More
IN USD

10

-

-

... More
IN JPY

10

-

-

... More
Supply one set of buckets (3 nos.) with round bottom made of GI sheets 24 SWG, 9 liter capacity painted inside white and outside red with a word ‘FIRE' on the face of the bucket along with stand to hang the buckets.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply of first aid chart and shock treatment chart with lamination complete.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying of wooden first aid box (Complete)

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supply of Rechargeable Emergency Lamp (600 mm LED lamp)

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying of AISI SS 316 Bolts, nuts and Washers for all the Flange joints for all above listed locations.

-

-

-

... More
IN INR

300

-

-

... More
IN USD

300

-

-

... More
IN JPY

300

-

-

... More
Supplying of Champion gaskets (Rubber Insertions) for all the Flange joints for all above listed locations (3 Ply RI Sheet)

-

-

-

... More
IN INR

200

-

-

... More
IN USD

200

-

-

... More
IN JPY

200

-

-

... More
Supply, Delivery, Installation, Testing & Commissioning of 30 kg/hr. automatic gas Chlorination system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
ICA Works (Refer General & Particular ICA specifications for scope of works)

-

-

-

... More
Supplying, Installing, commissioning & testing of Ultrasonic Level Indicating Transmitter with indicators & alarms (0- 10 m) on top of CWR at compartment-1 & 2, necessary IP 65 Enclosures and Interfacing with PLC based SCADA control system including all required Mounting accessories.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Additional LED Display for Digital Level Indication for local display signal looped with above ultrasonic level transmitter necessary IP 65 Enclosures.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying, Installing, commissioning & testing Conductivity type Level Switch High Level & Low-Level sensing with 4-point contact on top of GLR at compartment-1 & 2 with necessary IP 65 Enclosures, instrumentation cabling, glands with suitable stub and flange and bolting arrangement for hook-up, as applicable and necessary and also Interfacing with PLC based SCADA control system.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Providing and fixing gauge with iron sheet or Enamelled gauge plate of 3 mm to 4 mm thick, 0.23 m width copper floats indicators and flexible nylon wires, painting figures with approved enamel paint etc. with all lead and lifts, complete for: (Enamelled Gauge plate).

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
Supplying, Installing, commissioning & testing of Electromagnetic Flow Indicating Transmitter (full bore type- Measuring Range: 0-25000 m3/h) IP 68 Enclosures and 0.1 % accuracy with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, inner lining material suitable for potable water (minimum SS316), Outer body material suitable for Marine environment (minimum as SS316), earthing rings (minimum SS316) as applicable and necessary. (Meter Size-1200 mm) at common discharge delivery line and also Interfacing with PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Pump Performance (PPMS) Monitoring (IP 65 Enclosure) with required sensors, accessories, wiring and communication to PLC based SCADA system to measure temperature, vibration etc. for each pump set (covering all pumps), pump performance analysis, management & implementation etc.,

-

-

-

... More
Vibration sensor with Transmitter (IP 65 Enclosure) (for each Motor Casing & Pump Casing (DE/NDE)), 2 no. for each pumping unit.

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
Temperature sensor with RTD/Temperature transmitter (IP 65 Enclosure) for pump, 2 no. for each pump as required.

-

-

-

... More
IN INR

12

-

-

... More
IN USD

12

-

-

... More
IN JPY

12

-

-

... More
Temperature sensor with RTD/Temperature transmitter (IP 65 Enclosure) for motor (for each motor provided one for DE, NDE, U, V, W winding temperature).

-

-

-

... More
IN INR

30

-

-

... More
IN USD

30

-

-

... More
IN JPY

30

-

-

... More
Axial Displacement sensor (IP 65 Enclosure) one for each pump.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Supplying, Installing, commissioning & testing of Pressure Indicating Transmitter range as 0-16 bar (IP 65 Enclosures) at Pumps common discharge line with necessary instrumentation cabling, glands and nipple, fittings, conduit with suitable stub and flange, bolting arrangement for hook-up, as applicable, wetting parts with minimum Hastelloy C and also Interfacing with PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Pressure Switch (IP 65 Enclosures) (Measuring range 0-16 bar) at each delivery line of Pump with wetting parts with minimum Hastelloy C, necessary instrumentation cabling, glands and nipple, fittings, conduit with suitable stub and snubbers, flange and bolting arrangement for hook-up, as applicable and necessary also Interfacing with PLC based SCADA control system.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Pressure Gauge: Supplying, Installing, commissioning & testing of glycerin filled stainless steel pressure gauge (IP 65 Enclosures) of 150 mm Dia. suitable for the pump sets with nipple, snubber for vibration resistance, wetting parts with minimum Hastelloy C and necessary length of SS tubing suitable for mounting on the suction side of each pump, including 15 NB isolating valve for maintenance etc., complete with all lead and lifts etc., as applicable, and necessary. Bourdon type Pressure gauge (0-16 bar) at each Pumps suction line.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Pressure Gauge: Supplying, Installing, commissioning & testing of glycerin filled stainless steel pressure gauge (IP 65 Enclosures) of 150 mm Dia. suitable for the pump sets with nipple, snubber for vibration resistance, wetting parts with minimum Hastelloy C and necessary length of SS tubing suitable for mounting on the delivery side of each pump, including 15 NB isolating valve for maintenance etc., complete with all lead and lifts etc., as applicable, and necessary. Bourdon type Pressure gauge (0-16 bar) at each delivery line of Pump.

-

-

-

... More
IN INR

6

-

-

... More
IN USD

6

-

-

... More
IN JPY

6

-

-

... More
Pressure Gauge: Supplying, Installing, commissioning & testing of glycerin filled stainless steel pressure gauge (IP 65 Enclosures) of 150 mm Dia. suitable for the pump sets with nipple, snubber for vibration resistance, wetting parts with minimum Hastelloy C and necessary length of SS tubing suitable for mounting on the Common delivery pipeline of pump station, including 15 NB isolating valve for maintenance etc., complete with all lead and lifts etc., as applicable, and necessary. Bourdon type Pressure gauge (0-16 bar) at Pumps common discharge line.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Online Residual Chlorine Analyzer (Make: Hach/E&H/ Emerson /Krohe) proposed at pumps common discharge pipeline, Measuring Range:0-5 ppm (IP 65 Enclosures) with necessary instrumentation cabling, glands and conduit, calibration reagents, (Including installation accessories of Piping, Flow Control module, Isolation valves, drain line (vacuum breaker) etc.) and integration with plant PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Turbidity Analyzer (Make: Hach/E&H/ Emerson /Krohe) proposed at pumps common discharge pipeline, Measuring Range: :0-10 NTU (IP 65 Enclosures) with necessary instrumentation cabling, glands and conduit, calibration reagents, (Including installation accessories of Piping, Flow Control module, Isolation valves, drain line (vacuum breaker) etc.) and integration with plant PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Online Conductivity Analyzer (Make: Hach/E&H/ Emerson /Krohe) proposed at pumps common discharge pipeline, Measuring Range: 0-1000 Micro Siemens (IP 65 Enclosures) with necessary instrumentation cabling, glands and conduit, calibration reagents, (Including installation accessories of Piping, Flow Control module, Isolation valves, drain line (vacuum breaker) etc.) and integration with plant PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Online pH/Temperature Analyzer (Make: Hach/E&H/ Emerson /Krohe) proposed at pumps common discharge pipeline, Measuring Range: 0-14 (IP 65 Enclosures) with necessary instrumentation cabling, glands and conduit, calibration reagents, (Including installation accessories of Piping, Flow Control module, Isolation valves, drain line (vacuum breaker) etc.) and integration with plant PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Field instruments IP-65 enclosures for outdoor field instrumentation and Junction boxes with IP-65 enclosures as per site condition requirements and all other Installation of miscellaneous accessories such as Cable Conduits, L-sections, GI Pole Supports, Clamps, Nuts & Bolts etc.,

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Instrumentation, control and Automation earthing system (earthing bar, grounding cable, protection system) & Surge protection Devices for the instruments.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, installation, Testing and commissioning of online UPS system (minimum 5 KVA) with Isolation Transformer confirms to IS 16242 (Part-I): 2014 and IEC 60240-1: 2008 with IGBT technology pure sine wave output, double conversion with auto and manual static bypass switch single phase input / Single phase output with battery cell bank (include panel) (IP 55 Enclosures) for complete ICA equipment inclusive of all communication equipment, pump conditioning monitoring, sensors, field instrumentation and Automation / control system i.e. for PLC Control panel, SCADA control workstation / server, power sockets with minimum 4 hours backup on full load (Reputed Make Only) with Supply installation Testing and commissioning of Automatic transfer switch (ATS) as redundant for power supply source (Reputed Make Only).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, laying, installation, termination & testing of Instrument & power supply cables, glands, sleeves, TB, lugs, conduits, L-sections, GI Pole Supports, Clamps, Nuts & Bolts etc. with proper ventilation panel (include filters) and all accessories complete. (Also specify Running Meter cost additional during execution).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, laying, installation, termination & testing of FRP Cable tray 150 mm size (Also specify Running Meter cost additional during execution).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supply, installation, Testing and commissioning of Chlorine Gas leak detector with sensor element (IP 65 Enclosures) at Chlorinator Room 2 nos. and 1 no. at Toner Room Interfacing with PLC based SCADA control system special alarm Indicator and automated control operation of ventilation and exhaust system in case of emergency.

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Pressure Gauge: Supplying, Installing, commissioning & testing of glycerin filled stainless steel pressure gauge (IP 65 Enclosures) of 150 mm Dia. suitable for the pump sets with nipple, snubber for vibration resistance, wetting parts with minimum Hastelloy C and necessary length of tubing suitable for mounting on the Chlorine Common delivery pipeline of Chlorinator Dosing output, including 15 NB isolating valve with drain valve for maintenance etc., complete with all lead and lifts etc., as applicable, and necessary. Bourdon type Pressure gauge (range as 0-5 bar).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Electromagnetic Flow Indicating Transmitter (full bore type- Measuring Range: 0-60 kg/hr.) IP 65 Enclosures and 0.2 % accuracy with flange Ends, rates shall be inclusive of mating flanges with necessary fasteners and gaskets, inner lining material suitable for chlorine chemical (wetting parts with PTFE or above) and (electrode as minimum Hastelloy C or above), Outer body material suitable for Marine environment (minimum as SS316 or above), earthing rings as applicable and necessary. (Meter Size-65 DN) at common discharge delivery line and also Interfacing with PLC based SCADA control system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Pulsation Damper and pressure reducer valve with complete accessories suitable for chlorine system.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Automation System (Refer General & Particular ICA specifications for scope of works)

-

-

-

... More
Supplying, Installing, commissioning & testing of PLC based Control System with option of local control panel HMI screen. It comprises of a dedicated standalone backplane slots embedded with Redundant power supply, CPU Controller systems (Hot and Redundant) protected in an internal wiring PLC control panel having IO Module, a minimum quantities of IO channels which shall be DI:176, DO:82, AI:100, AO:8 and Control Panel shall have the following accessories as minimum like Potential Free Contacts, communication modules (for third party devices data integration to controller), Redundant power supply unit for SMPS systems, Emergency stop push buttons, Ack / reset Push buttons, Lightening Protection Units (LPUs) / Isolators for each Analog Input, 3 nos. of 24-window Alarm Annunciators, Industrial type Ethernet switch (Redundant) with communication link (Redundant) and the same will be configured with Local Area Network (LAN) system) as redundant loops, RTU / RIO units & interface module, Terminal Blocks, LIU units, Panel air ventilation (Filters) and all other panel accessories as required. (IP 55 Enclosures Panel) (Reputed Makes Only).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Latest model (Hardware/software) Laptop (Programming/diagnostics system) with original license key software’s of Operating System, M.S Office included with application and installed software (Intel core processor-I7, 16 GB RAM DDR5, 1 TB HDD, 14" HD screen, HD camera, Graphics card size based on application (OS/PLC/SCADA) requirements), warranty, bag.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
PLC programming application software, SCADA Graphics, control and other Designing application software with all accessories complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
SCADA Control Workstations: SCADA Operator workstations (OWS) and Engineering Control Server Workstation (EWS).

-

-

-

... More
Supplying, Installing, commissioning & testing of Engineering Control Server Workstation Tower type (EWS) integrated redundant SCADA server system (SCADA is on dual redundant server). EWS Hardware Specifications: Minimum Intel Xeon Core Processor W series (3.6 GHz, or the fastest at the time of supply), compatible below items 16 GB DDR5 RAM, 2 nos. 1TB+ HDD, 10K RPM (SATA/SAS) - OS / Application / SQL DB and Transaction Logs RAID 5 series, NC364T PCI express Quad port gigabit Server Adapter 750 W CS HE power supply kit Graphics Adapter – 2 X DVI-I Redundant Ethernet min. 100 Mbps Network interface card Windows Server 2012 x 64 Standard/Data Centre SQL Express (Included) 32" LED Monitor, SATA DVDRW, Keyboard, Mouse, 2 Nos. of Front Ports USB 2.0 & 2 Nos. of Rear Ports with USB 3.0, Card Reader, Num of PCI-E*16 slots: 1, No. of PCI-E*1 slot: 2 HDMI out, Audio Port: Headphone Output Microphone, other default items as per model. Makes: - (DELL / HP) Note: All the hardware and software shall be provided with product license, latest version and with upgradable options for future expansions.

-

-

-

... More
IN INR

2

-

-

... More
IN USD

2

-

-

... More
IN JPY

2

-

-

... More
OWS (SCADA Operator Workstation) Hardware Specifications : Intel Core i7 (3.5GHz) Processor or advanced processor suitable for workstation,16 GB DDR5, 1TB HD 7200 RPM, 32" LED Monitor, Dedicated Graphics Card 2GB, DVD RW, Key Board, Mouse, 2 Nos. of Front Ports USB 2.0 & 2 Nos. of Rear Ports with USB 3.0, Card Reader, Num of PCI-E*16 slots: 1, No. of PCI-E*1 slot: 2 HDMI out, Audio Port: Headphone Output Microphone, other default items as per model. Makes: - DELL / HP) Note: All the hardware and software shall be provided with latest version and with upgradable options for future expansions.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
OWS & EWS software: Latest Windows OS compatible for control system application software, Latest MS OFFICE, and other applicable pre-installed software as per standard supply. Note: All the software shall be provided with latest version and with upgradable options.

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Supplying, Installing, commissioning & testing of SCADA Server application (Real time/Historian) Software with license for SCADA EWS/Server stations (2 nos.). Supplying, Installing, commissioning & testing of SCADA application (Real time/Historian) Software with license for SCADA Operation workstation (1 no.).

-

-

-

... More
IN INR

3

-

-

... More
IN USD

3

-

-

... More
IN JPY

3

-

-

... More
Fiber Optics cable patch card (as required quantity) and Ethernet, Fiber Optics cable with armoured cable (Also specify Running Meter cost additional during execution).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Online & offline Laser Jet All-in One-Color Printer (Reputed Make Only) with all accessories complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of minimum LED screen 55" with HDMI/VGA switch with all accessories complete and interface with the plant SCADA Control system to view the operational GUI.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Communication Interface and Cybersecurity Equipment

-

-

-

... More
Supplying, Installing, commissioning & testing of Industrial Managed Modem/Router/Switch (Redundant device configuration) (Reputed Make).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Firewall Device, web server and others if any (Reputed Make).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Wireless Communication System (GSM / GPRS Wireless Gateway is to be configured with control system) minimum 5G network or advanced version during execution and any additional equipment for interfacing/exchanging data with CMWSSB control center room, CP1 and CP3 package contractor, Remote access etc. with all accessories complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Monitoring Requirements

-

-

-

... More
Supplying, Installing, commissioning & testing of Control desk station in control room as per IEC standard with suitable ergonomic furniture (OWS/EWS/CMMS Concole-4 Nos. and 4 Nos. of Chair). i.e., SCADA control System industrial consoles for housing the complete (Operator/workstation/server) system with all accessories complete.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Fire Detection and Alarm system at Porur pumping station control room. Fire Alarm Panel including controller, IO and interface modules Detectors/sensor Autonomy UPS backup Power supply module others if any

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of Access control system Following item as minimum Card Reader Door locks Door contact switch exit push buttons Access cards Access control device Power supply module Alarm and communication unit and others if any

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, Installing, commissioning & testing of public addressing system based at Porur Pumping station control room with autonomy UPS backup includes loudspeakers (quantity depends on floor level and priority station) and with their respective power supply units. Microphone units, alarm units Telephone system (for internal and external networks)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, installing, commissioning & testing of CCTV IR waterproof camera (IP 65 Enclosures for outdoor) suitable for up to 100 ft. with IR Dome camera, control keyboard, DVR, Hard Disk, cables, UPT trans receivers, autonomy UPS for backup etc. (Close Circuit Television System to be installed at Porur pumping station and reservoir facility to cover all areas within CP2 package facilities).

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Supplying, installing, commissioning & testing of CCTV server station loaded with CCTV application software, latest Windows operating system; 32" LED monitors connected via LAN network to SCADA servers. Minimum 1TB hard drive.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Walkie/Talkie instrument for internal communication required during testing, commissioning and Operation & Maintenance including its accessories charger, power chord etc. Minimum quantity as 4 nos.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Other items

-

-

-

... More
Critical spares as required for Commissioning and pumping station startup

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Tools items Tester Screw drivers set Digital Multimeter Clamp On Meter Spanners sets Hart communicator Milliampere source meter Voltage converter compact air blowers/vacuum cleaner special application software’s Jumpers, etc. And others if items as required during execution or testing

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Other expenses like monthly or periodic billing in terms from Internet service provider related for external communication to be included.

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
SCHEDULE 7.OPERATION & MAINTENANCE FOR TWENTY YEARS

-

-

-

... More
1st Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
2nd Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
3rd Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
4th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
5th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
6th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
7th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
8th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
9th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
10th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
11th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
12th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
13th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
14th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
15th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
16th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
17th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
18th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
19th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
20th Year O&M Price

-

-

-

... More
Fixed Cost per Year (Manpower, Administrative cost, Routine Maintenance and any other fixed cost)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Variable Cost per Year (Chemical, Lubricants, Consumables, Spare parts, Repairs, etc., for maintenance)

-

-

-

... More
IN INR

1

-

-

... More
IN USD

1

-

-

... More
IN JPY

1

-

-

... More
Subtotal excluding GST

1

-

-

... More
GST @18%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.