Chennai Metropolitan Water Supply And Sewerage Board Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Chennai Metropolitan Water Supply And Sewerage Board - CMWSSB Tender

Civil And Construction
Eprocure
Opening Date29 Oct 2021
Closing Date8 Nov 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
500x200mm A/F Tee

1

-

-

... More
500 mm DI Fl/ Spi tail piece

1

-

-

... More
500 mm DI Fl/ Soc tail piece

1

-

-

... More
500mm MJ Collar

2

-

-

... More
200mm 90 deg A/S bend

8

-

-

... More
200mm dia DI Duck Foot Bend

1

-

-

... More
200mm dia DI D/F Pipe 1.00m

4

-

-

... More
200mm dia DI D/F Pipe 0.5m

4

-

-

... More
200 mm dia D/F 90 degree Bend

4

-

-

... More
200mm MJ Collar

9

-

-

... More
200x200 mm DI A/F tee

2

-

-

... More
200 mm DI Fl/ Spi tail piece

9

-

-

... More
200 mm DI Fl/ Soc tail piece

9

-

-

... More
200x80 mm DI S/S/F tee

2

-

-

... More
Supplying and delivery at site, conveying and fixing of CI double air valves of following sizes including loading, unloading, Transportation charges and stacking etc complete as per specifications. 80mm CI double Air valve

2

-

-

... More
Supplying , delivery at site, conveying and fixing the CI sluice valves (PN 1.0) including DI tail pieces of following sizes confirming to IS: 14846/2000 including socket and flanged tail pieces etc., loading,unloading, Transportation charges and stacking etc complete as per specifications.

-

-

-

... More
200 mm CI Sluice Valve

4

-

-

... More
Supplying , delivery at site, conveying and fixing the CI sluice valves (PN 1.0) including DI tail pieces of following sizes confirming to IS: 14846/2000 including socket and flanged tail pieces etc., loading,unloading, Transportation charges and stacking etc complete as per specifications. 80 mm CI Sluice Valve for Air Valve

2

-

-

... More
Cutting DI mains

-

-

-

... More
500mm dia

2

-

-

... More
200mm dia

46

-

-

... More
Construction of chamber for 100mm to 250mm dia.sluice valve including providing and fixing L.S. cover and frame of size 60 x 60cm for size 1.35 x 1.2 x 1.55 m

4

-

-

... More
Construction of 80mm Double Air Valve chamber for 100mm to 350mm dia.pipeline including providing and fixing FRC cover and frame of size 60 x 60cm for size 1.2 x 0.9 x 1.8

2

-

-

... More
Jointing the D.I. Double flanged pipes and specials with rubber insertion to the required specifications with M.S. bolts and nuts, complete and testing the pipes to the required pressure with water (including cost of jointing materials) etc. complete

-

-

-

... More
80mm dia

4

-

-

... More
200mm dia

18

-

-

... More
Making Rubber joints for DI pipes specials including jointing Materials.

-

-

-

... More
200mm dia

195

-

-

... More
Testing of DI pipes with hydraulic Testing equipment by filling with water (including cost of water) and Testing to recommended pressure in convenient stretches and attending the bursts if any occurred during the test, excluding the cost of pipes, including other incidental and operational charges, etc., complete for the following diametres of pipes.

-

-

-

... More
200mm dia

1200

-

-

... More
Barrication work along one side of the trench for laying the pipe line with casuarina post at 1.52m centre to centre (8 to 10 cm dia. and 1.52m height) verticals, painting the vertical posts in different colours, tieing with coir rope, fixing danger flags, danger lights, reflectors including watching during night for 1 metre.

2400

-

-

... More
Providing thrust blocks with Plain Cement Concrete in 1:3:6 with 40mm HBG for the DI pumping main including the cost of shuttering, compaction, curing etc. complete.

-

-

-

... More
200mm 90 deg A/S bend

10

-

-

... More
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304) for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output. The microprocessor based signal converter shall have a selfdiagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished.

-

-

-

... More
200mm

1

-

-

... More
Supplying and fixing of Spool piece for flow meter

1

-

-

... More
Supply and Delivery of Remote Monitoring data logger with Operating voltage of 24 VDC and with inbuilt program memory back up, RTC, Adequate number of analogue, digital inputs & outputs and with minimum - I/O spares, Interface to GSM/GPRS modem along with Panel with all internal wirings, 24V DC Power supply unit, 16 channel solid state relays, terminal blocks, MCB, Overload protectors etc. SPECIFICATION: Input Power: 24 VDC, 5 Watts Max CPu Speed: 32 MHz or better Application Program Memory: 128KB Flash minimum Data Memory: 8 K bytes SRAM 4MB Flash Flash Memory Retention: 100 years without power I/O Capacity (Expansion): 32 Inputs / outputs Display: 16 Character 2 line Backlit LCD display or better Serial Protocol: 1.Modus RTU Slave/Master 2.Remote Monitoring and Control via GSM/GPRS Network Programming Parameters: From Keyboard, Server, Smart Phone/tablet Programming Languages: LD, FBD, C, Phython, Java, GSM-GPRS Communication

1

-

-

... More
Hire charges for diesel pumpset upto 3 HP to 7.5 HPwith fuel and crew charges including transportation

185

-

-

... More
Construction of chamber for 200mm dia.Flow meter including providing room for fixing the display unit, etc., as diretcted by Engineer in charge

1

-

-

... More
Cutting asphalitc concrete road

-

-

-

... More
Non Bus Route

625

-

-

... More
Bus Route

550

-

-

... More
Connection work to existing main including cutting existing pipe, fixing branches, collars, lead jointing and bailing out water, etc., excluding excavation.

-

-

-

... More
Cutting 450mm to 300mm (18” to 12”) C.I. pipe and fixing 450mm to 50mm (18” to 2”)

1

-

-

... More
Cutting 250mm to 175mm (10" to 7") CI Pipe and fixing 250 to 50mm (10" to 2") branch

1

-

-

... More
Supply and fixing of 1HP mono blockpump set for dewatering.

1

-

-

... More
Earthing as per the ISI specification with necessary masonry work

1

-

-

... More
Supplying and fixing of 32Amps triple pole SFU with rewirable fuse units on suitable angle iron frame with earth connection only

1

-

-

... More
Wiring with 2.5 sq.mm PVC unsheathed copper single core in suitable conduit pipe for lighting with joint box and switch box with continuous earth connection by 14 SWG TC wire

1

-

-

... More
Supplying and fixing of box type 4’ 40W single fluorescent fitting complete with TW round block and tube on ceiling or wall with connection.

2

-

-

... More
Supplying and clamping of 2 core 25sq.mm. PVC LTUG cable by MS clamps on wall

50

-

-

... More
Wiring with 2.5 sq.mm. PVC unsheathed SC copper cable on suitable rigid PVC pipe for 5A 3 pin CS plug non interlocking including S&F plug pin top in TW box with continuous earth connection by 14 SWG TC wire

5

-

-

... More
Run of 2 of 2.5 sq.mm. PVC unsheathed copper SC cable in conduit pipe for mains continuous earth connection by 14 SWG TC wire

100

-

-

... More
Providing MS sheet box for fixing the display unit and electrical switches, and power control units.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.